| 1 | Dismantling single layer Mangalore pattern or similar tiles in roofing including ridge tiles complete all as specified and directed.Notes: All works under this BOQ will be executed for buildings of height up to four storeys. Contractor shall make all necessary proper scaffolding arrangements and safety measures for labours at site. |
| 2 | M&L for roof tiles, Mangalore pattern, interlocking at side joints, laid dry complete all as specified and directed. |
| 3 | All as per Sl No. 2 here-in-before, but except tiles complete all as specified and directed.Note: Serviceable tiles obtained from item No. 1.00 here-in-before will be reused under this item. |
| 4 | M&L for ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in cement mortar 1:6 complete all as specified and directed. |
| 5 | All as per Sl No. 4 here-in-before, but except tiles complete all as specified and directed.Note: Serviceable tiles obtained from item No. 1.00 here-in-before will be reused under this item. |
| 6 | Demolition of cement concrete (unreinforced) in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed. |
| 7 | M&L for providing, cement concrete type B-0, 1:2:4 using 12.5 mm graded stone aggregate in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed. |
| 8 | Dismantling wooden fillets for roof tiles battens, rails, posts, rafters, purlins etc. under 40 sq.cm in section (unframed work) complete all as specified and directed. |
| 9 | M&L for second class hardwood plain fillets (sectional area exceeding 13 sq.cm and not exceeding 25 sq.cm), square, rectangular or triangular in section, clean sawn, secured with nails or brads complete all as specified and directed. |
| 10 | All as per Sl No. 9 here-in-before, but except fillets complete all as specified and directed.Note: Serviceable fillets obtained from item No. 8.00 here-in-before will be reused under this item. |
| 11 | Dismantling timber scantlings 40 sq. cm and over in section, unframed work, in any position complete all as specified and directed. |
| 12 | M&L for second class hardwood in scantlings, clean sawn complete all as specified and directed. |
| 13 | All as per Sl No. 12 here-in-before, but except scantlings complete all as specified and directed.Note: Serviceable scantlings obtained from item No. 11.00 here-in-before will be reused under this item. |
| 14 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed. |
| 15 | M&L for 4 mm thickness non-asbestos fibre cement building boards (decorative type) fixed or laid/ inserted to timber/ GI/ Aluminium framework with screws complete all as specified and directed. |
| 16 | Fixing only in repairs 4 mm thickness non-asbestos fibre cement building boards (decorative type) fixed or laid/ inserted to timber/ GI/ Aluminium framework with screws complete all as specified and directed.Note: Serviceable boards obtained from item No. 14.00 here-in-before will be reused under this item. |
| 17 | S&F anodised aluminium snap grid frame work (size of grid 605x605 mm) with 35x25x1.5 mm main tee and 25x25x1.4 mm cross tee and wall angle for false ceiling complete all as specified and directed. |
| 18 | S&F hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. |
| 19 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 20 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed. |
| 21 | Dismantling Asbestos cement (corrugated, semi corrugated, etc.) sheets in roof covering complete all as specified and directed. |
| 22 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self-tapping screws/ J-hooks complete all as specified and directed. |
| 23 | S&F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self-tapping screws/ J-hooks complete all as specified and directed. |
| 24 | Demolition of brick work/ PCC block/ stone wall masonry built in cement mortar and removing the debris/ rubbish to a distance not exceeding 50 mtr complete all as specified and directed. |
| 25 | M&L for pre-cast cement concrete block masonry type C1, 1:3:6 using 20mm graded stone aggregate with solid blocks exceeding 10 cm in width and setting in CM 1:4 complete all as specified and directed. |
| 26 | M&L for roughening surfaces of old concrete floor by picking old damaged tar felt/ water proof membrane any type, sweeping clean and washing down with water to remove dust, etc complete all as specified and directed. |
| 27 | M&L for 40 mm thick, PCC 1:2:4, Type B-0, using 12.5mm graded stone aggregate over RCC roof as levelling course complete all as specified and directed. |
| 28 | M&L for rendering 10 mm thick cement plaster on fair faces of brick work/ concrete surfaces in cement mortar 1:3, mixed with water proofing compound @ 3% by the weight of cement, finished even and smooth without using extra cement complete all as specified and directed.Note: Water proofing compound shall be measured and paid separately. |
| 29 | Material and labour for water proofing treatment over RCC slab by applying oil bound bitumen primer @ 0.27 Lit/Sqm. Provide and lay 4 mm thick APP modified membrane not less than 4.5 Kg/Sqm ,reinforced with non woven polyester matt weighing not less than 160 gm/Sqm having softening point not less than 140 degree centigrade, tearing strength of 180 N , a static puncture resistance of 180, keeping minimum 10 cm side overlap and 15 cm end overlap and apply by torch application over a coat of blown grade hot bitumen grade VG-10 conforming to IS 702 heated to a working temperature of 180 centigrade and applied @ 1.2 kg/Sqm of the surface area and finishing the top surface with solar reflective bituminous aluminium paint @ 0.1 Kg/Sqm including taking down existing cement mortar plaster complete all as specified and directed by Engr- In- Charge. Note:-(a) 10 years guarantee certificate to be submitted by the contractor (b) Water proofing treatment will be done by manufacturer of APP membrane or through their authorised specialised agency/applicator which will further have to rectification of any defect if incurred at a later stage, otherwise no payment shall be made to the contractor if water proofing treatment is executed otherwise. |
| 30 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed. |
| 31 | M&L for rendering in two layers 10mm thick with cement mortar (1:6) and 5 mm thick with cement mortar (1:4), finishing coat mixed with water proofing compound @ 3% by the weight of cement on fair faces of brick work in external surfaces of wall complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately. |
| 32 | M&L for rendering 5 mm thick cement plaster on fair faces of brick work/concrete surfaces (in ceiling/ facia) in cement mortar 1:3, finished even and smooth without using extra cement complete all as specified and directed. |
| 33 | M&L for rendering 10 mm thick cement plaster on fair faces of brick work/concrete surfaces in cement mortar 1:6, finished even and smooth without using extra cement complete all as specified and directed. |
| 34 | Supply only integral water proofing compound. |
| 35 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 36 | M&L for preparation of newly plastered wall surfaces and applying 2mm thick wall care putty and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed. |
| 37 | M&L for preparation of newly plastered ceiling surfaces and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed. |
| 38 | S&F 160mm bore PVC (SWR) pipes single socketed, including bend/ joint etc. all fittings, in any length with rubber ring joints laid in trenches or in floors or fixed to walls including taking down old damaged cast iron pipes/ PVC pipes (including all fittings), burning out joints etc to facilitate dismantling old serviceable fittings/ pipes laid in trenches, floors or fixed to walls, including necessary earth work, demolition of PCC/ brick work and making good to match with existing surfaces, including necessary scaffolding complete all as specified and directed. |
| 39 | Cutting/ cleaning small trees, saplings, shrubs and under growth complete roots from brick walls, chajjas etc including taking out complete roots from inside walls/ chajjas and making good surfaces in cement concrete 1:2:4 type B1 or in cement mortar (1:4) to match the existing surfaces complete all as specified and directed. |
| 40 | Disconnecting existing water tanks exc 250 Ltr and n.exc 500 Ltr capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position after cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. complete all as specified and directed. |
| 41 | M&L for clearing vegetation/ shrubs along with all the debris of leaf from roofs, sunshades, etc and making surface clean as per the site requirement/ condition complete all as specified and directed. |
| 42 | Demolition of cement concrete (unreinforced) including tiles and screed bed of any description in any position not otherwise specially provided for complete all as specified and directed. |
| 43 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off the premises complete all as specified and as directed. |
| 44 | Demolition Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed |
| 45 | M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite laid over and including 20mm thick screed bed in CM 1:6 complete all as specified and directed |
| 46 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed |
| 47 | M&L for 25 mm thick, PCC 1:2:4, Type B-0, using 12.5mm graded stone aggregate as in sub-base for flooring/ levelling coarse, sunken floor etc. complete all as specified and directed. |
| 48 | M&L for 15 mm thick screed bed in cement mortar 1:4 for lying floor finishes (upto four storey buildings) complete all as specified and directed. |
| 49 | M&L for rendering 10 mm thick cement plaster in cement mortar 1:3 as backing coat for fixing wall finishes over stone masonry or other than fair faces of brick work/ PCC solid block masonry/ concrete (upto four storey building) complete all as specified and directed. |
| 50 | M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 51 | M&L for glazed ceramic coloured tiles 450x 300x 7mm thick on vertical surfaces set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed. |
| 52 | M&L for non - skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 53 | All as per item ser No 52 here-in-before but as in vertical surface (dado/Skirting) to match the shade of floor tiles laid complete all as specified and directed. |
| 54 | M&L for vitrified ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm and not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the existing complete all as specified and directed. |
| 55 | M&L for vitrified ceramic light shade tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm and not exceeding 0.42 sqm, on vertical surfaces such as skirting, dado and risers to steps etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the existing complete all as specified and directed. |
| 56 | M&L for 75mm thick cement concrete type C2, 1:3:6 using 40 mm graded stone aggregate as in plinth protection, hard standing, etc. finishing surface even and smooth without using extra cement complete all as specified and directed. |
| 57 | Taking down shutters of any description exceeding 1 sqm and not exceeding 2 sqm each and refixing the same opening after necessary easing and adjusting complete all as specified and as directed. |
| 58 | S&F in repairs vitreous China wash down closet pan of size 540 x 375 x 415mm 'P' or 'S' trap (Pedestal pattern) white (excluding fixing bolts, flushing cistern and flush pipe), including plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 59 | S&F in repairs vitreous China squatting pan, 'Orissa' pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) complete all as specified and directed. |
| 60 | S&F in repairs PVC valve less, syphonic action type, flushing cistern 10 litres capacity, low level, white, with inlet, ball valve, float and handle including brackets for support, and connection to pipes and fixing in chain and pull or lever with PVC connections 20mm size with PTMT nuts of length 600mm complete all as specified and directed. |
| 61 | S&F in repairs health faucet, brass, chromium plated including flexible PVC pipe with steel lining of 1 mtr long, chromium plated, with push button suitable for 15mm pipe complete all as specified and directed. |
| 62 | S&F in repairs stop valves 15 mm bore dia, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 63 | S&F in repairs stop valves 15 mm bore dia, cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type), screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 64 | S&F in repairs looking mirror, size 600mmx450mm, bevelled edge, selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 65 | S&F in repairs PVC connections 15mm size with 02 Nos brass check nuts with washer of length 600mm complete all as specified and directed. |
| 66 | S&F in repairs Vitreous China wash basin, white, flat back, size 630x450mm including cutting for and pinning in ends of brackets or erecting stand and connected fittings including PVC connections 15/20mm size with PTMT nuts of length 600mm complete all as specified and directed. |
| 67 | M&L for 32 mm dia. waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed including taking down old existing waste fittings complete all as specified and directed. |
| 68 | S&F in repairs pillar taps of size 15mm bore dia, cast copper alloy with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly-nuts screwed for iron pipe complete all as specified and directed. |
| 69 | S&F in repairs bib tap of size 15mm bore dia, cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 70 | Demolition and breaking up drain pipes of dia 150mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar including necessary bend, T and other accessories complete all as specified and directed. |
| 71 | S& F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors including necessary clamps etc complete all as specified and directed |
| 72 | S& F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors including necessary clamps etc complete all as specified and directed |
| 73 | S&F 100mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised, type B-21 complete all as specified and directed. |
| 74 | S&F PVC (SWR) floor trap, outlet 75 mm dia, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 75 | Taking down 20mm steel/CPVC tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed |
| 76 | Cutting chases in concrete block walls, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc, and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed. |
| 77 | Supplying and laying of CPVC pipes 20mm dia outer bore SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all asspecified. |
| 78 | S&F in repairs shower rose, brass, chromium plated 125mm size with or without swivel joints, fixed to steel pipe or union complete all as specified and directed. |
| 79 | S&F in repairs brass, chromium plated tubular towel rail, 20 mm dia, D type 60 cm long between flanges complete all as specified and directed. Please Enable Macros to View BoQ information |