Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | GATEEarth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 Sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 3 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. |
| 4 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : for slabs |
| 5 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : for the lighter beams i.e. having spans upto 6 m. |
| 6 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : R.C.C. Raft foundation and footing with approved stone ballast. (Using 1:1.5:3 Mix concrete) |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 8 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 9 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1 :6 ( 1 cement : 6 coarse sand) |
| 10 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S.clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin- charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. |
| 11 | Centring and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete. |
| 12 | Centring and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 13 | Centring and shuttering including strutting, propping etc. and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts |
| 14 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :Red sand stone - exposed face fine dressed with roughbacking.50 mm thick |
| 15 | Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in wallswherever required. |
| 16 | Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases. |
| 17 | carving work |
| 18 | Mild steel or iron work of heavy sizes and sections such as holding down bolts, hold fast tierods, gratings etc. (when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. |
| 19 | Painting or varnishing work in small areas or new wood work with one coat upto one square metre of ready mixed priming paint and one coat of approed superior quality ready mixed paint or varnish including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. Paint to be used should fonfirm the ISI no. 103-1950 (M.S. works). |
| 20 | YATRI SHEDEarth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil0.00 to 1.50 Mtr. |
| 21 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 22 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 23 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 24 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 25 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement:2 coarse sand) to match the existing floor. With Chlorpyriphos/ Linadane E.C. 20% with 1% concentration. |
| 26 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 27 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). for slabs (Using 1:1.5:3 Mix concrete). |
| 28 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). for the lighter beams i.e. having spans upto 6 m. |
| 29 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).R.C.C. Raft foundation and footing with approved stone ballast. (Using 1:1.5:3 Mix concrete) |
| 30 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 31 | Centring and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete. |
| 32 | Centring and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 33 | Centring and shuttering including strutting, propping etc. and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts |
| 34 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 35 | Painting on D.P.C. with two coats of airblown bitumen 85/50 or 85/25 @ 1.7 kg/sqm approx. including cost of fuel if any. |
| 36 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 37 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) |
| 38 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 39 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand). |
| 40 | 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand) |
| 41 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) |
| 42 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 43 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade. (FLOORING) |
| 44 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade. (skirting) |
| 45 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite work |
| 46 | 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1 :5 (1 cement : 5 coarse sand), including pointing with cement mortar 1 :2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone. |
| 47 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth |
| 48 | Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces : Two coat |
| 49 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)(Outer surface) |
| 50 | Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces : Two coat |
| 51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 52 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 53 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin- charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. |
| 54 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :Red sand stone - exposed face fine dressed with roughbacking.50 mm thick |
| 55 | Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in wallswherever required. |
| 56 | Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases. |
| 57 | carving work |
| 58 | PLUMBINGProviding and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board610x510 mm bowl depth 200 mm |
| 59 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 60 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Semi rigid pipe 40mm dia |
| 61 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes.110mm diameter |
| 62 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.110mm |
| 63 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110mm |
| 64 | Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore |
| 65 | Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 15mm nominal bore |
| 66 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 67 | ELECTRICALWiring point for Light with 1.5sq. mm. FR PVC insulated multistrand single core copper cable in PVC conduit with 1.5 sq.mm. FR PVC-insulated multistrand Copper conductor cable as earth wire drawn in side the conduit. Add for light/fans with moduler type switch. |
| 68 | Wiring point for two ways light point with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in Surface/Recessed medium class PVC conduit 2 way modular switch modular plate suitable G.I. Box and earthing the point with 1.5 seq mm FRLS PVC insulated Copper conductor Single core cable etc. as required. |
| 69 | Wiring point for Fan with 1.5sq. mm. FR PVC insulated multistrand single core copper cable in PVC conduit with 1.5 sq. mm. FR PVC-insulated multistrand Copper conductor cable as earth wire drawn in side the conduit. Add for light/fans with moduler type switch. |
| 70 | Wiring point for Plug with 1.5sq. mm. FR PVC insulated multistrand single core copper cable in PVC conduit with 5 sq. mm. FR PVC insulated multistrand Copper conductor cable as earth wire drawn in side the conduit. Add for light/fans with moduler type switch and socket. |
| 71 | Wiring point for Exhaust fan with 1.5sq. mm. FR PVC insulated multistrand single core copper cable in PVC conduit with 1.5 sq. mm. FR PVC-insulated multistrand Copper conductor cable as earth wire drawn in side the conduit. Add for light/fans with moduler type switch. |
| 72 | Supply fixing & concealing of PVC conduit in the wall including cutting of brick laying of conduit & fixing it with MS hooks & then plastering.with cement, sand,mortar finished to the level,with matching colour wash including cost of proper thrading of Size 25 mm dia 16SWG (2 mm)thick |
| 73 | S/F of power plug modular type with 15 Amp./250 volts switch & socket etc. |
| 74 | Supplying and fixing TV antenna socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 75 | Supply & wiring of submains with 2 nos.1.5 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia Medium Class PVC conduit partly concealed in wall and partly laid in slab along with the reinforcement b 2x1.5+1x1.5 |
| 76 | Supply & wiring of submains with 2 nos.2.5 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia Medium Class PVC conduit partly concealed in wall and partly laid in slabalong with the reinforcement bef |
| 77 | Supply & wiring of submains with 2 nos.4 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia Medium Class PVC Conduit partly concealed in wall and partly laid in slab along with the reinforcement befo |
| 78 | Supply & wiring of submains with 4 nos. 6 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 32 mm dia Medium Class PVC conduit partly concealed in wall and partly laid in slab along with the reinforcement bef |
| 79 | Supply & wiring of submains with 4 nos.10 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 40 mm dia Medium class PVC conduit partly concealed in wall and partly laid in slab along with the reinforcement bef |
| 80 | Supply & fixing and making connection of 40 amp. 4P 30 mA ELCB/ RCCB of Din Rail mounting in complete in all respect as per direction and satisfaction to the Engineer in Charge. |
| 81 | Supply & fixing and making connection of 63 amp. 4P 30 mA ELCB/ RCCB of Din Rail mounting in complete in all respect as per direction and satisfaction to the Engineer in Charge. |
| 82 | Supply & fixing of Batton/Angle holder including making connection etc. as required. |
| 83 | Supply and fixing of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect.2420 system lumens, 110 Im/W, PF>0.95, THD<10%, CRI>80, sheet Thickness 0.8 mm, Tube with aluminium heat with 5 year warrantee. |
| 84 | Supply and fixing of water tight oblong 10 Watt LED bulk head luminaire having die cast housing with driver set confirming to IP 65 and above Protection.Complete in all respect. 1100 system lumens, 110 Im/W, PF>0.95 with 5 year warrantee. |
| 85 | Supply and fixing of 3 watt to 6 watt LED Decorative mirror light (spot light) fitting Confirming to IP 65 and above protection Complete in all respect.330-660 system lumens 1101m/W, PF>0.95, THD<20% at full load , with 5 year warrantee |
| 86 | Supply of ceilling fans with fan motor of A.C Permanent insulation, capacitor rating conforming BEE 5 Star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated voltage 220/240 volts,50 Hz, 1-Ph AC the fan assemble shouldBEE 5 Star rated-1200 mm sweep |
| 87 | Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surfsize 150 sq mm x 3-1/2core |
| 88 | Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earth size 150 sq mm x 3-1/2core |
| 89 | Supply and fixing of plain or pin type copper tin plated cable socket (lug) to cable leads for pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable size 150 sq mm |
| 90 | Supply and burying earth electrode for lighting conductor of 600mm x 600mm x 3mm Copper plate vertically with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe for watering funnel, 30cm square C.I. frame with hinged cover mason |
| 91 | Supply and fixing of horizontal air termination (roof conductor) of 25mm x 5mm copper strip, on G.I. clamps on surface complete in all respects as approved by Engineer-in-charge. |
| 92 | Supply and fixing of vertical air termination final rod comprising of 300mm long x 25mm dia. Copper rod with one pointed prong and 100mm dia x 3 mm thick base plate etc. complete in all respect. AS Per DSR |
| 93 | Supply and laying of 32 mm x 6 mm copper strip from earth electrode directly in the ground as required complete in all respects. |
| 94 | Supply and fixing of testing joint of copper strip 32mm x 6mm and 150mm long with tinned of brass bolts and nut etc. complete in all respect. |
| 95 | Supply and fixing of 240 volts C Curve 6-32 amp SP miniature circuit breaker (10 K A ) in existing MCB, DB complete with connections as required. |
| 96 | Supply and fixing of 240 volts C Curve 40 amp 4P miniature circuit breaker (10 K A ) in existing MCB, DB complete with connections as required. |
| 97 | Supply and fixing of 240 volts C Curve 63 amp 4P miniature circuit breaker (10 K A ) in existing MCB, DB complete with connections as required. |
| 98 | Supply and fixing of flush/surface mounting 4 ways TPN distribution boards (Legrand Lexic) without MCB with additional metal door complete in all respects. As directed by engineer incharge. 4 WAY |
| 99 | Supply and fixing of flush/surface mounting 8 ways TPN distribution boards (Legrand Lexic) without MCB with additional metal door complete in all respects. As directed by engineer incharge. |
| 100 | Supply & Fixing of MCB blanking plate for DB. |
| 101 | Supply and Fixing of Danger Board fabricated from 10 gauge M.S. Sheet as per I.E. Rules |
| 102 | Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects. |
| 103 | Erection and testing of exhaust fan on the existing hole with suitable size rag bolt nut & washer etc. complete in all respects. |
| 104 | Supply and fixing of 16 gauge MS drum duly painted including making hole in the wall for exhaust fan and finshing propely complete in all respect. |
| 105 | Supply and Fixing of shock treatment chart.prescribed as per I.E. Rules.duly framed with glass and supported from back with hard board or shoft board with supply of all material ,labour,T&P for proper completion of work. |
| 106 | Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules |
| 107 | Supply and fixing of power plug with 20A/250V flush type Moduler switch and 5 Pin 20A/250V flush type universal Moduler socket in suitable Conceled MS Box including supply of all material, labour,T&P etc.required for proper completion of work. |
| 108 | Supply and fixing of 240 volts 63amp DP miniature circuit breaker (10 K A ) in with sheet steel encloser box, complete with connections as required.(for Air conditioning/Main incoming.) |
| 109 | S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid i |
| 110 | Supply fixing of electronic fan regulator (Modular) 120-280 V. ISI marked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work. TWO MODULE |
| 111 | Supplying and drawing Co axial T V cable, RG-6 grade, 0.7 mm solid copper conductor, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/PVC conduit as required. |
| 112 | Supply and fixing following module G.I box along with moduler base with cover plate :1 or 2 Module (75mmX75mm) |
| 113 | Supply and fixing following module G.I box along with moduler base with cover plate :3 Module (100mmX75mm) |
| 114 | Supply and fixing following module G.I box along with moduler base with cover plate :4 Module (125mmX75mm) |
| 115 | Supply and fixing following module G.I box along with moduler base with cover plate :6 Module (200mmX75mm) |
| 116 | Supply and fixing following module G.I box along with moduler base with cover plate :8 Module (125mmX125mm) |
| 117 | Supply and fixing following module G.I box along with moduler base with cover plate :12 Module (200mmX150mm) |
| 118 | Supply & Fixing of Moduler switch blanking plate for Moduler switch board. |
| 119 | TOILET BLOCKEarth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil0.00 to 1.50 Mtr. |
| 120 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 121 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 122 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 123 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement:2 coarse sand) to match the existing floor. With Chlorpyriphos/ Linadane E.C. 20% with 1% concentration. |
| 124 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 125 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). for slabs (Using 1:1.5:3 Mix concrete). |
| 126 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).for the lighter beams i.e. having spans upto 6 m. |
| 127 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).R.C.C. Raft foundation and footing with approved stone ballast. (Using 1:1.5:3 Mix concrete) |
| 128 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 129 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 130 | Painting on D.P.C. with two coats of airblown bitumen 85/50 or 85/25 @ 1.7 kg/sqm approx. including cost of fuel if any. |
| 131 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 132 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) |
| 133 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 134 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand). |
| 135 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 136 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade. (FLOORING) |
| 137 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade. (skirting) |
| 138 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite work |
| 139 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. (FLOORING) |
| 140 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth |
| 141 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (Both side laminated)35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Single leaf. |
| 142 | Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturer's specification and irection of Engineer-in-charge. |
| 143 | Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces : Two coat |
| 144 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)(Outer surface) |
| 145 | Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces : Two coat |
| 146 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 147 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. |
| 148 | Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . |
| 149 | Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete300 mm x 10mm |
| 150 | Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete250 mm x 10mm |
| 151 | Providing and fixing stainless steel handles with screws etc. complete (a) 125 mm |
| 152 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4 mm thick |
| 153 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin- charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. |
| 154 | PLUMBINGProviding and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever requiredfor European type W.C. pan with white plastic seat and lid. |
| 155 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap. |
| 156 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:Range of three urinal basins with 10 litre white P.V.C. automatic flushing cistern Parryware/ Hindware Seabird/ Orient (Coral) |
| 157 | Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth.Granite Stone of approved shade |
| 158 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 159 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Semi rigid pipe 32mm dia |
| 160 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 161 | Providing & fixing soil, waste and vent pipes. 100mm dia centrifugally cast iron S & S pipe. |
| 162 | Providing & fixing soil, waste and vent pipes. 75mm dia centrifugally cast iron S & S pipe. |
| 163 | Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size). Including cost of cutting holes & making good the walls etc. for 100mm dia pipe. |
| 164 | Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size). Including cost of cutting holes & making good the walls etc.for 75mm dia pipe. |
| 165 | Providing and fixing plain cast iron S & S sanitary bend. 100mm |
| 166 | Providing and fixing plain cast iron S & S sanitary bend.75mm |
| 167 | Providing and fixing centrifugaly cast iron single equal plain junction of required degree.100x100x100mm |
| 168 | Providing and fixing centrifugaly cast iron single equal plain junction of required degree.75x75x75mm |
| 169 | Providing and fixing terminal guard : Sand cast iron S&S as per IS - 3989100 mm |
| 170 | Providing & fixing cast iron coller.100mm dia. |
| 171 | Providing & fixing cast iron coller.75mm dia. |
| 172 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters.100mm |
| 173 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters.75mm |
| 174 | Providing & fixing cast iron trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. 100mm inlet & 75mm outlet. |
| 175 | Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) fornew work100 mm diameter pipe |
| 176 | Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms |
| 177 | Providing & fixing PTMT towl rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm. long towl rail length of 645 mm. width 78 mm. and effective height of 88 mm, weighing not less than 190 gms. |
| 178 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes.110mm diameter |
| 179 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.110mm |
| 180 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110mm |
| 181 | Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. (internal work) Exposed on wall25mm dia nominal bore (medium duty) |
| 182 | Concealed pipe including painting with anticorrosive bitumatic paint, cutting chases and making good the wall.15mm dia nominal bore |
| 183 | Concealed pipe including painting with anticorrosive bitumatic paint, cutting chases and making good the wall.20mm dia nominal bore |
| 184 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work 15mm dia nominal bore |
| 185 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work20mm dia nominal bore |
| 186 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work25mm dia nominal bore (medium duty) |
| 187 | Providing and fixing gun metal gate valve with wheel of approved quality.25mm dia nominal bore |
| 188 | Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions.15mm nominal bore |
| 189 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work15 mm dia nominal bore |
| 190 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work20 mm dia nominal bore |
| 191 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work25 mm dia nominal bore |
| 192 | Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality.15mm dia nominal bore. |
| 193 | Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality.20mm dia nominal bore. |
| 194 | Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality.25mm dia nominal bore. |
| 195 | Providing and fixing G.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work)15mm dia nominal bore. |
| 196 | Providing and fixing G.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work) 20mm dia nominal bore. |
| 197 | Providing and fixing G.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work)25mm dia nominal bore. |
| 198 | Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 15mm nominal bore |
| 199 | Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15mm nominal bore |
| 200 | Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 893115mm nominal bore |
| 201 | Providing and fixing PTMT grating of approved quality and colour Circular type100 mm nominal dia |
| 202 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 203 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m.Pipes 80mm to 300mm diameter. |
| 204 | Providing, laying and joining glazed stone ware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.100mm diameter |
| 205 | Providing, laying and joining glazed stone ware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.150mm diameter |
| 206 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. 100mm diameter S.W. Pipe |
| 207 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design.150mm diameter S.W. Pipe |
| 208 | Providing and fixing square mouth S.W. Gully trap grade 'A' complete with C.I. grating brick masonry chamber with F.P.S. bricks of class designation 75 and water tight C.I. cover with frame of 300 x 300mm. size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design.150 x 100 mm. size P type |
| 209 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. comp150 mm dia rcc pipe |
| 210 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. comp250 mm dia rcc pipe |
| 211 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80 cm & 45 cm deep including C.I. cover with frame (light duty) total wt. of cover & frame to be not less than 38 Kg (wt. of cover 23 Kg & wt. of frame 15 Kg. |
| 212 | Extra for depth of man hole size 90x80 cm |
| 213 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x120 cm & 90 cm deep including C.I. cover with frame (medium duty) total wt. of cover & frame to be not less than 116 Kg (wt. of cover 58 Kg & wt. of frame 58 Kg. |
| 214 | Extra for depth of man hole size 90x120 cm |
| 215 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar |
| 216 | ELECTRICALWiring point for Light with 1.5sq. mm. FR PVC insulated multistrand single core copper cable in PVC conduit with 1.5 sq.mm. FR PVC-insulated multistrand Copper conductor cable as earth wire drawn in side the conduit. Add for light/fans with moduler type switch. |
| 217 | Wiring point for Plug with 1.5sq. mm. FR PVC insulated multistrand single core copper cable in PVC conduit with 5 sq. mm. FR PVC insulated multistrand Copper conductor cable as earth wire drawn in side the conduit. Add for light/fans with moduler type switch and socket. |
| 218 | Wiring point for Exhaust fan with 1.5sq. mm. FR PVC insulated multistrand single core copper cable in PVC conduit with 1.5 sq. mm. FR PVC-insulated multistrand Copper conductor cable as earth wire drawn in side the conduit. Add for light/fans with moduler type switch. |
| 219 | Supply fixing & concealing of PVC conduit in the wall including cutting of brick laying of conduit & fixing it with MS hooks & then plastering.with cement, sand,mortar finished to the level,with matching colour wash including cost of proper thrading of Size 25 mm dia 16SWG (2 mm)thick |
| 220 | S/F of power plug modular type with 15 Amp./250 volts switch & socket etc. |
| 221 | Supplying and fixing TV antenna socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 222 | Supply & wiring of submains with 2 nos.1.5 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia Medium Class PVC conduit partly concealed in wall and partly laid in slab along with the reinforcement b |
| 223 | Supply & wiring of submains with 2 nos.2.5 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia Medium Class PVC conduit partly concealed in wall and partly laid in slabalong with the reinforcement bef |
| 224 | Supply & wiring of submains with 2 nos.4 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia Medium Class PVC Conduit partly concealed in wall and partly laid in slab along with the reinforcement befo |
| 225 | Supply & fixing and making connection of 40 amp. 4P 30 mA ELCB/ RCCB of Din Rail mounting in complete in all respect as per direction and satisfaction to the Engineer in Charge. |
| 226 | Supply & fixing and making connection of 63 amp. 4P 30 mA ELCB/ RCCB of Din Rail mounting in complete in all respect as per direction and satisfaction to the Engineer in Charge. |
| 227 | Supply & fixing of Batton/Angle holder including making connection etc. as required. |
| 228 | Supply and fixing of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect. 2420 system lumens, 110 Im/W, PF>0.95, THD<10%, CRI>80, sheet Thickness 0.8 mm, Tube with aluminium heat with 5 year warrantee. |
| 229 | Supply and fixing of 240 volts C Curve 6-32 amp SP miniature circuit breaker (10 K A ) in existing MCB, DB complete with connections as required. |
| 230 | Supply and fixing of 240 volts C Curve 40 amp 4P miniature circuit breaker (10 K A ) in existing MCB, DB complete with connections as required. |
| 231 | Supply and fixing of 240 volts C Curve 63 amp 4P miniature circuit breaker (10 K A ) in existing MCB, DB complete with connections as required. |
| 232 | Supply and fixing of flush/surface mounting 4 ways TPN distribution boards (Legrand Lexic) without MCB with additional metal door complete in all respects. As directed by engineer incharge. CAT A |
| 233 | Supply & Fixing of MCB blanking plate for DB. |
| 234 | Supply and Fixing of Danger Board fabricated from 10 gauge M.S. Sheet as per I.E. Rules |
| 235 | Erection and testing of exhaust fan on the existing hole with suitable size rag bolt nut & washer etc. complete in all respects. |
| 236 | Supply and fixing of 16 gauge MS drum duly painted including making hole in the wall for exhaust fan and finshing propely complete in all respect. |
| 237 | Supply and Fixing of shock treatment chart.prescribed as per I.E. Rules.duly framed with glass and supported from back with hard board or shoft board with supply of all material ,labour,T&P for proper completion of work. |
| 238 | Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules |
| 239 | Supply and fixing of power plug with 20A/250V flush type Moduler switch and 5 Pin 20A/250V flush type universal Moduler socket in suitable Conceled MS Box including supply of all material, labour,T&P etc.required for proper completion of work. |
| 240 | Supply and fixing of 240 volts 63amp DP miniature circuit breaker (10 K A ) in with sheet steel encloser box, complete with connections as required.(for Air conditioning/Main incoming.) |
| 241 | Supply and fixing following module G.I box along with moduler base with cover plate :1 or 2 Module (75mmX75mm) |
| 242 | Supply and fixing following module G.I box along with moduler base with cover plate :3 Module (100mmX75mm) |
| 243 | Supply and fixing following module G.I box along with moduler base with cover plate :4 Module (125mmX75mm) |
| 244 | Supply and fixing following module G.I box along with moduler base with cover plate :6 Module (200mmX75mm) |
| 245 | Supply and fixing following module G.I box along with moduler base with cover plate :8 Module (125mmX125mm) |
| 246 | Supply & Fixing of Moduler switch blanking plate for Moduler switch board. |
| 247 | BEAUTIFICATION OF TEMPLEExcavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. |
| 248 | Filling of carted earth. |
| 249 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) |
| 250 | First Class brick work in 1:6 cement and coarse sand of 1.25 F.M. mortar in foundation and plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. (1:6 cement & coarse sand) |
| 251 | Painting on DPC with two coats of air blown bitumen 85/50 or 85/25 @ 1.7 kg/sqm. Approx including cost of fuel if any. |
| 252 | First Class brick work in 1:6 cement and coarse sand in super-structure above plinth level up to floor two level ( up to two storeys ) including necessary cutting and moulding of brick work as required and also including honeycombed brick work in thickness of wall more than 12cms. (1:4 cement : coarse sand) |
| 253 | 15 mm thick plinth plaster [1 cement : 4 coarse sand] |
| 254 | 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand |
| 255 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :Red sand stone - exposed face fine dressed with rough backing.30 mm thick |
| 256 | Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. |
| 257 | Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases. |
| 258 | EXTERNAL PLUMBINGProviding and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require a) White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tappillar tap. |
| 259 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Semi rigid pipe 32mm dia |
| 260 | Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade |
| 261 | Providing & fixing soil, waste and vent pipes.75mm dia centrifugally cast iron S & S pipe. |
| 262 | Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size). Including cost of cutting holes & making good the walls etc.for 75mm dia pipe. |
| 263 | Providing & fixing cast iron coller.75mm dia. |
| 264 | Providing and fixing plain cast iron S & S sanitary bend.75mm |
| 265 | Providing and fixing centrifugaly cast iron single equal plain junction of required degree.75x75x75mm |
| 266 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes.110mm diameter |
| 267 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.110mm |
| 268 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110mm |
| 269 | Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. (internal work) Exposed on wall25mm dia nominal bore (medium duty) |
| 270 | Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. (internal work) Exposed on wall 32mm dia nominal bore (medium duty) |
| 271 | Concealed pipe including painting with anticorrosive bitumatic paint, cutting chases and making good the wall.15mm dia nominal bore |
| 272 | Concealed pipe including painting with anticorrosive bitumatic paint, cutting chases and making good the wall.20mm dia nominal bore |
| 273 | Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality. 15mm dia nominal bore. |
| 274 | Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality.20mm dia nominal bore. |
| 275 | Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality.25mm dia nominal bore. |
| 276 | Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality.32mm dia nominal bore. |
| 277 | Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions.15mm nominal bore |
| 278 | Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15mm nominal bore |
| 279 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 280 | Providing and fixing square mouth S.W. Gully trap grade 'A' complete with C.I. grating brick masonry chamber with F.P.S. bricks of class designation 75 and water tight C.I. cover with frame of 300 x 300mm. size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design.150 x 100 mm. size P type |
| 281 | R.O. Machine system water cooler |
| 282 | SUBMERSIBLE WITH BOARINGDrilling of 200 mm dia bore hole. |
| 283 | Supply of 125 mm dia MS pipe as per IS1239 |
| 284 | Supply of 125 mm dia slotted MS pipe |
| 285 | Supply and fixing of nylon jali around the slotted pipes complete as required. |
| 286 | Providing and packing of coarse sand / pea gravel around the pipe. |
| 287 | Transport of boring tools other required equipements and installation at site. |
| 288 | Supply of submersible pump of make KSB 2.0 HP with control panel, support wire etc. complete. |
| 289 | Providing 3 core PVC insulated submersible cable. (from pump panel to submersible pump) |
| 290 | Providing and fixing 65 mm dia. G.I. pipe complete with fittings and clamps including cutting and making good the wall etc. (from submersible pump to ground level) |
| 291 | Providing and fixing 65 mm dia. brass gate valve with CI wheel of approved quality. |
| 292 | Lowering of 125 mm dia MS pipe in bore hole including cutting, jointing etc complete. |
| 293 | Supply and fixing of tube well accessories i.e. well cap, clips, clamps, etc. to complete the job in all respect. |
| 294 | Fixing, testing and commissioning for erection and lowering of submersible pump, 65 mm dia GI column pipe, 3 core submersible copper cable upto the control panel, supporting clamps, cable clips, pressure gauge, connection line and all other accessories required for the proper completion of the work. |
| 295 | Testing and development of tube well. |
| 296 | FOOTPATH WITH STAMP FLOORINGEarth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil. |
| 297 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size) including supply of all materials,Labour and T & P etc. required for proper completion of the work and curing complete also including cost of formwork in foundation and floors. |
| 298 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana I Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate I retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: |
| 299 | ACI Textured/High Performance Stamped Concrete Applying and finishing the top surface of concrete in accordance with the following procedure:Sprinkling of ACI color hardener at the rate of 3.33 kg/sq.m.Floating the surface using different types of floaters.Application of release agent at the rate of 0.118 kg/sq.m.Stamping the concrete using stamping tools.Cleaning the surface with water.Application of acrylic-based sealer at the rate of 0.38 liters/sq.m for final finishing. |
| 300 | Material RCC concrete with mild steelFinish Smooth finish with a polished or painted surface Dimensions (Approx.) Length: 4 ft (1220 mm)Width: 1.5 ft (450 mm)Height: 1.5 ft (450 mm)Support Design Ornamental column-style pedestals with floral/scroll motifTop Slab Thickness 2 to 3 inches (50–75 mm)Logo/Engraving \\"UAT UESTOS\\" engraved or printed on the surfaceInstallation Base Cement-tiled pavement or garden tilesUsage Outdoor park/garden/public spaces |
| 301 | EXTERNAL ELECTRIFICATIONSupply & fixing of steel tubular pole 9 Metre long designated 410 SP 32 in 1:3:6 cement concrete foundation including excavation backfilling etc. complete in all respect. |
| 302 | Supply & fixing of steel tubular pole 9 Metre long designated 410 SP 32 in 1:3:6 cement concrete foundation including excavation backfilling etc. complete in all respect. |
| 303 | Havells All in One Solar Street Light (LHSTAKU7CBAF015)Solar Street Light (LED based) consist of white LED luminaire (LED + Driver) rating as per configuration along with Solar PV modules and LiFePo4 battery of given capacity, necessary control electronics, interconnecting wires / cables, module mounting structures, etc. to operate from dusk to dawnSpecification: .Power output of PV Module: ≥ 75 Wp at 16.4 ±0.2 Volt at STC Battery capacity: ≥ 12.8 V (nominal), 30 Ah at STC (1 day autonomy) Type of LED (Light source): 40Watt White LED type Ingress protection: IP65 or better Indicators on the system: Provided with 2 LED indicators: a green light to indicate charging in progress and a red LED to indicate deep discharge condition of the battery. The green LED glow only when the battery is actually being charged. Nominal bore size of tube / Thickness of tube: 65 mm / 4.5mm Height of pole (in m): 6 Battery box: Battery included in the luminaire enclosure, with water proof (IP65 or better) and corrosion resistant For more detail please refer attached quote. |
| 304 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 Watt. Confirming to IP 66 and above Protection complete in all respect. |
| 305 | Supply & Fixing Pipe Bracket with Clamp suitable for Fixing of 75/90 Watt LED Street Light Complete as per Direction of Engineer in Charge |
| 306 | Supply and laying of 16 sq. mm 4 core aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade over head.as directed by the Engineer-Incharge, complete in all respect .The armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 307 | Supply and fixing 40 A TPN capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch, metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect as per direction of the Engineer in charge. |
| 308 | Supply and laying of 16 sq. mm.plain or pin type aluminium in plated cable socket with end to end cable pieces, insulating with tape and making connection with pole & panel board as per direction of the Engineer-in-charge. |
| 309 | Supply & erection of stay set at least 3.5 Metres away from the pole complete with galvanised 19 mm dia x1.80 Metre long stay rod, 30 cm x 30 cm x 6.3 mm anchor plate, thimble stay clamps, stay insulator, 19 mm x 600 double screw tightening, 7/4.00 mm G.I. stay wire etc. in 1:3:6 cement concrete complete in all respect. |
| 310 | Aluminium White Outdoor Led Bollard Light, Mounting Type: Surface, B22 |
| 311 | 15w high beam narrow highlighter |
| 312 | 3w Aluminium LED In Ground Uplighter, For Outdoor, Voltage: 210V |
| 313 | 24 W Facade Light Designs, For Outdoor |
| 314 | SIGNAGEEarth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 Sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. |
| 315 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 316 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. |
| 317 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). Lintel |
| 318 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).Raft foundation and footing with approved stone ballast. (Using 1:1.5:3 Mix concrete) |
| 319 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 320 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 321 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 322 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :Red sand stone - exposed face fine dressed with rough backing.30 mm thick |
| 323 | Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. |
| 324 | Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases. |
| 325 | Stone writing |
| 326 | Horticulture & Landscape WorksEarth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. |
| 327 | Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment) |
| 328 | Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 4.75 mm |
| 329 | Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). |
| 330 | Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge |
| 331 | Filling mixture of earth and sludge or manure in the desired proportion in trenches, flooding with water and leveling (cost of supplying earth and sludge or manure and mixing excluded). |
| 332 | Anti termite treatment by digging holes 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration and as per direction of officer-in-charge |
| 333 | Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water) Trees PlantFor Trees/Plants |
| 334 | Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water) Trees PlantHedges Plant/ Ground cover |
| 335 | Supply and stacking of Delonix regia (Gulmohar) plant of height 150-165 cm. in big polybag of size 25 cm as per direction of the officer -in-charge. |
| 336 | Supply and stacking of Cassia fistula (Amaltash) plant of height 120-135 cm. in big polybag of size 25 cm as per direction of the officer -in-charge. |
| 337 | Supply and stacking of Azadirachta indica (Neem) plant of height 120-130 cm. in big polybag of size 25 cm as per direction of the officer -in-charge. |
| 338 | Providing and stacking of Phyllanthus emblica (Amla) of height 150-165 cm. in Big HDPE Bagas per direction of the officer-in-charge.Detail of cost each plant 10319 Phyllanthus emblica (Amla) height 150-165 cm. in Big HDPE Bag |
| 339 | Providing and stacking of Pongamia glabra (Papri) of height 120-135 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge. Pongamia glabra (Papri) height 120-135 cm. in big poly bag size 25 cm |
| 340 | Providing and stacking of Plumeria alba of height 120-135 cm. with 2-3 branches in bags of size 30 cm as per direction of the officer-in-charge. Detail of cost each plant 10324 Plumeria alba height 120-135 cm. with 2-3 branches in bags size 30 cm |
| 341 | Providing and stacking of Tabernaemontana coronaria (Chandni single) of height 90-105 cm.,bushy in big size HDPE bag as per direction of theofficer-in-charge. |
| 342 | Providing and Stacking of Tulsi of ht. 30cm with multi branches in Poly bag of size 20 cm. as per direction of the officer-in-chargeDetails of cost each plant :10498 Tulsi of ht. 30cm with multi branches in Poly bag of size 20 cm. |
| 343 | Providing and stacking of Cestrum nocturnum (Raat ki Rani) of height 60-75 cm. with 4-5 branches in bag of size 25 cm as per direction of the officer-in-charge.Cestrum nocturnum (Raat ki Rani) of height 6075 cm. with 4-5 branches in bag of size 25 cm |
| 344 | Providing and stacking of Nerium oleander (kaner) of height 45-60 cm. with 3-4 branches in poly bags of size 20 cm as per direction of the officer-in-charge.Nerium oleander (Kaner) of height 45-60 cm. with 3-4 branches in poly bags of size 20 cm |
| 345 | Providing and stacking Jasmine grandiflorum (chameli) of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. .Jasmine grandiflorum (chameli) of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots. |
| 346 | P/F of Dustbin |
| 347 | P/F of Mural Wall |
| 348 | G.S.T Extra as per applicable Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail