| 1 | EXCAVATION AND EARTH WORKSurface excavation not exceeding 30cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and as directed. |
| 2 | Material and labour 25 mm sand cushioning for interlocking tiles including well rammed and consolidation complete all as specified and as directed. |
| 3 | Removal of bushes, grass including roots, earth, mud and debris over roof top of building material from roof top surface and cleaning the effected surface neatly and disposal of rubbish out of the premises/ MD land including cleaning of spouts/ rain water pipe ( at two/three storey building) complete all as specified and as directed.Note: Surface area of roof slab for the affected area shall be measured. |
| 4 | Grubbing up tree trunk upto root girth exc. 5 cm & not exc. 30 cm including cutting of trunk portion protruding over wall surface/roof surface/terrace of building height up to 10.0 mtr. The rate also Include necessary scaffolding and necessary safety measure if required and making good the surface in cement mortar (1:3) and applying one coat of anti growth of vegetation chemical as per manufacturer's instruction and removal of unserviceable material out side MD land and cleaning site complete all as specified and directed |
| 5 | CONCRETE WORKMaterial and labour lean concrete type E-2 (1:5:10) using 40mm grade stone aggregate as in sunken portion complete all as specified and directed |
| 6 | Material and labour plain cement concrete (1:2:4) type B-0 using 12.5 mm graded stone aggregate as in padding on roof laid in required slope, complete all as specified and directed |
| 7 | Material and labour plain cement concrete B-0 type (1:2:4) using 12.5 mm graded crushed stone aggregate as in copings, bed plates, benching and the like finished fair & even, including necessary form work complete all as specified and directed.NOTES :-(i) PCC shall be laid in slope and thickness shall be average (minimum average thickness 25 mm or as per site requirement for maintaining the slope to drain out rain water as directed.(ii) No hand mixing shall be allowed, mixing shall be done at ground floor and mixed materials deposited on roof by manually/mechanically to achieve the proper strength and workmanship. |
| 8 | Material and labour for PCC (1:4:8) type D-2 (40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed |
| 9 | Material and labour for Reinforced cement concrete (Nominal mix) 1:2:4 type B1 (using 20mm graded crushed stone aggregate) as in chajjas, facia etc shelves and the like, at any height, complete all as specified and directed |
| 10 | Material and labour for providing water proofing treatment of sunken portion of WCs, bathroom etc. by applying cement slurry mixed with Acrylic based polymer modified cementitious composite compound coating of make as approval in Technical Instruction 5/2003 by adding: (a) 15mm thick plaster (1:4) cement sand mortar with integral water proofing compound 2% by weight of cement on floor and wall / beam , finishing the surface even and smooth without using extra cement. The surface shall then be cured and allowed to dry. Note: Water proofing compound shall be measured and paid separately. (b) First layer of slurry of cement @0.5 kg/sqm mixed with Acrylic based polymer modified cementitious composite compound @ 0.25 kg/sqm. This layer will be allowed to air cure for 4 hrs. (c) Second layer of slurry of cement @0.25 kg/sqm mixed with Acrylic based polymer modified cementitious composite compound @ 0.15 kg/sqm. This layer will be allowed to air cure for 4 hrs followed with water curing for 48 hrs. complete all as specified and directed by Engineer-in-charge.(d) Ponding test to be carried out for minimum 24 hrs before filling of sunken slab. |
| 11 | Material and labour for providing and laying integral water proofing adhesive of avg 2-3mm thick as per steps given below:- (a) RCC/Concrete/ Plastered Surfaces of roof shall be cleaned of all dirt, foreign articles. (b) Filling of all voids/cracks with poly plastic fibre adhesive and laying of fibre mesh (45gm) over defective surface and applying 2 coats as repair over defective surface with plastic fibre coating adhesive, wall bind of european paints and chemicals of approved equivalent. (c) Application of Poly Plastic fibre adhesive over full surface of roof/concrete surface with fibre mesh including 450 mm height over vertical surface/walls/parapet. (d) Use of White cement in each layer of treatment shall be strictly as per manufacturer's instructions. Note:- Contractor will be required to submit a valid MOU. In addition to this Authorised Applicator of above mentioned adhesive manufacturer shall have valid authorization letter from manufacturer issued not earlier than 60 days from the start date of this work. |
| 12 | Supply only liquid water proofing compound complete all as specified and as directed |
| 13 | Material and labour for repair of structurally distressed RCC members including scaffolding for suitable working platform as in column, beams, chajjas and roof projections in following stages:- (i) Removing all disintegrated and loose concrete upto 50mm thickness and cleaning the rust from exposed reinforcement, removing rusted scales by chipping and cleaning by wire brushes with minimum clear air gap of 20mm all around the reinforced steel. (ii) Treating the exposed reinforced steel including removing debris away from site to a designated point pre-defined by local administrator or at a distance exc 1.5 KM but not exc 2.5KM with rust removal chemical followed by epoxy zinc rich primer.(iii) treating the exposed old RCC surface with epoxy bonding agent for bonding between old/new concrete surface. (iv) Replacement of old steel reinforcement whose dia remains less than 50% due to rust with new steel coated with epoxy zinc rich primer in same position binding with black wire/ welding. (Payment of steel reinforcement shall be made against relevant item). (v) Material and providing polymer modified reinstatement mortar of thickness up to 50 mm in layers not exe 25mm thick over vertical or overhead surface of RCC members complete as per manufacturer's instruction (vi) Curing the reinstated surface with water for minimum 7 days. |
| 14 | BRICK WORKMaterial and labour for cutting holes into or through brick walls built in cement mortar or cement lime mortar having superficial area not exceed 150 Sqcm each. making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 complete all as specified and directed |
| 15 | Material and labour for cutting chases, pinning in , making good to facings where required and pointing in cement mortar 1:3 to ends, cills , sunshades shelves etc and cutting chases for concealed water tubing etc, and making good cutting of exc 10 cm but not exceeding 20 cm girth in brick walls making good complete all as specified and directed. |
| 16 | Material and labour for cutting holes through brick wall built in cement mortar, for inserting holdfasts, depth of embedded portion of holdfasts exceeding half brick thick but not exceeding one brick thick and making good the dismantled portion with PCC type B-0, (1:2:4) and cement mortar (1:3) to match the disturbed surface with existing finish, complete all as specified and directed. |
| 17 | FORMWORK Material and labour for use and waste of formwork to chullah hoods, chajjas, facia, troughs and similar, items in cluding edges, including stagging and scaffolding up to 10 mtr heights, complete all as specified and as directed. |
| 18 | JOINERY WORKTaking down chowkats or frames with shutters (without taking off shutters from the frames) exe 1.5 Sqm but n exc 4.00 sqm each complete all as specified and as directed. |
| 19 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) area not exe 1.5 Sqm each complete all as specified and directed. |
| 20 | Taking down shutter of any size and refixing in the same position complete all as specified and directed. |
| 21 | Material and labour for factory made single extruded WPC (wood polymer composite) solid door/ window/ ceosetory windows & other frames/ chowkhat of size 45x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice huck/ wheat huck ) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire resistant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed. Note: For item no. 21.00 to 24.00(i) WPC solid door/ window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. (ii) Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made |
| 22 | Material and labour for Factory made single extruded WPC (wood polymer composite) solid door/ window/ ceosetory windows & other frames/ chowkhat of size 50x100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice huck/ wheat huck ) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire resistant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed. |
| 23 | Material and labour for factory made single extruded WPC (wood polymer composite) solid plain flush shutter of 30 mm size comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice huck/ wheat huck ) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire resistant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and as directed. |
| 24 | Material and labour for Factory made single extruded WPC (wood polymer composite) solid plain flush shutter of 35 mm size comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice huck/ wheat huck ) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire resistant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and as directed Note: MS hold fast/lugs or SS dash fasteners shall be paid for separately. |
| 25 | Material and labour for providing and fixing factory made uPVC white colour sliding window three track area not exceeding 2.00sqm each made of extruded profiles with wall thickness of 2.3mm ( + – 0.2mm). Window profile with hollow section with multi chamber, frame (88mm x 52mm),sliding sash (42mm x 67mm). sliding mesh sash (42mm x 57mm) sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 + – 0.2mm thick galvanized steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100mm long fasteners. Hardware Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories complete all as specified and as directed.Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. |
| 26 | BUILDERS HARDWARE WORKSupply and fix in repair tubular towel rail of brass chromium plated 20mm dia, D type, 60cm long between flanges complete all as specified and as directed |
| 27 | Supply and fixed in repair continuous (Piano) hinges, mild steel, bright finish or electrogalvanized, width of flaps when open 30mm complete all as specified and directed. |
| 28 | Supply and fix Mild steel pressed handles, oval type, stove enamelled black 125 mm size fixed complete all as specified and directed. |
| 29 | Supply and fix 125 mm size hasp and staple safety type aluminium anodized complete all as specified and directed. |
| 30 | Supply and fix in repairs 300 mm SS sliding door bolts, plate type stove enamelled black, with bright, bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts four on bolt plate and two on staple plate fixed in repair complete all as specified and directed. |
| 31 | Supply and fix 200 mm long aluminium anodized barrel tower bolts of extruded section and fixed, complete all as specified and directed. |
| 32 | Supply and fix 150 mm aluminium handles cast type anodised, complete all as specified and directed. |
| 33 | Supply and fix But hinges 100 mm size, mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed. |
| 34 | Supply and fix 300 mm mild steel ordinary rat tail rod pattern springs, including roller & roller plate complete all as specified directed. |
| 35 | Supply and fix floor door stopper of Aluminium alloy body anodised with hard drawn steel spring 150mm size fixed in floor complete all as specified directed. |
| 36 | Supply and fix in repair 25 mm dia SS curtain rod powder coated including taking down existing curtain rod / pelmet Including all fittings and fixtures and making good complete all as specified directed. |
| 37 | Supply and fix Aluminium powder coated door seal strip with glass wolves fixed with steel screws at bottom rail of external door complete all as specified directed. |
| 38 | STEEL, IRON AND ALUMINIUM WORKSupply and fix framed work such as grills, gratings, etc. with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290. Gde-E-165 including welding of any thick complete all as specified and as directed |
| 39 | Supply and fix Mild steel TMT bars 10 mm dia and over cut to length and bent to shape as required, including cranking , bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.90 mm dia complete, all as specified and as directed. |
| 40 | ROOF COVERING WORKSupply and fix in repairs 18/19 mm thick Block board grade II quality interior grade commercial type with out decorative face including supplying & fixing 18 mm wide edge tape of same texture to all exposed edges complete all as specified and directed. |
| 41 | CEILING AND LINING WORKMaterial and labour for RCC M-25 design mix as in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses including all necessary work complete, all as specified and as directed. |
| 42 | FLOOR FINISHES AND PAVING WORKS Material and labour for 25 mm thick cement concrete (1:2:4) type B-0 using 12.5 mm graded stone aggregates as in flooring laid in slope complete all as specified and directed. |
| 43 | Material and labour for 40 mm thick, PCC (1:2:4) type B-1 using 20 mm graded stone aggregates as in flooring finished/plinth protection even & smooth with using extra cement complete all as specified and directed. |
| 44 | Material and labour for 28 mm Wide Plastic dividing strips, 1.5mm thick, inserted in position, conform to design complete all as specified and directed. |
| 45 | Material and labour for rubberised machine pressed pre polished precast concrete interlocking paver block any shape, size , desired colour and pattern conforming to IS 15658-2006 of 80 mm thickness M-40 grade with grey cement and pigment , complete all as specified and directed. |
| 46 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing) removing rubbish off the premises complete all as specified and as directed. |
| 47 | Material and labour for coloured glazed ceramic tiles 300 x 450 mm & 7-8 mm thick on vertical surfaces of colour pattern as approved and as per manufacturer's catalogue such as in skirting, dado's etc. set and jointed in cement slurry over and including 10 mm thick bedding layer/backing coat in Cement Mortar 1:4 complete and painted in white or coloured cement to match complete all as specified and as directed.NOTE :- Skirting shall be provided to match with colour and size of floor tiles provided in rooms and other locations. |
| 48 | Material and labour for coloured non skid ceramic tiles 7 to 8 mm thick of colour pattern as approved and as per manufacturer's catalogue (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floor etc. over 15mm thick screed bed with Cement Mortar 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.NOTE :- This item shall not be measured for the flooring in sunken portion of toilet, bath and kitchen. |
| 49 | Material and labour for non skid ceramic tiles 10mm thick (Square/ rectangular) area of each tile not exceeding 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles complete all as specified and directed. |
| 50 | Roughening the surfaces of old concrete roof surfaces & sides by picking, brushing with wire brush, sweeping clean and washing down with water to remove dust etc., brushing neat cement slurry with 3.0 kg of cement per Sqm over cleaned roof surfaces complete all as specified and directed |
| 51 | Material and labour for 18-20 mm thick granite (of any type) work (table rubbed and polished) in platforms/stair case/ countertop including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including rounding off/curving the edges of granite stone & polishing including demolition of tile of any description or thickness and including screed bed 15mm thick in cement mortar 1:6 complete all as specified and directed, |
| 52 | Material and labour for machine cut cudappah stone 20 mm to 25 mm thick over and including 20 mm thick cement screed bed in CM 1:6 laid and jointed in grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and as directed. |
| 53 | Material and labour for kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.NOTES :- (i) The exposed edges of treads shall be provided in full moulding and with three line grooves in each tread as directed.(ii) The treads and risers shall be provided with single piece kota stone. |
| 54 | PLASTERING WORKTaking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with etc. and removal of demolished material out of residential area complete all as specified and as directed. |
| 55 | Material and labour for 15 mm thick cement plaster in Cement Mortar 1:6 on brick surface finished even and smooth without using extra cement including in patches complete all as specified and as directed. |
| 56 | Material and labour for 10 mm thick cement plaster in Cement Mortar 1:3 as in ceiling finished even and smooth without using extra cement including in patches complete all as specified and as directed. |
| 57 | Material and labour for 15 mm thick cement plaster in Cement Mortar 1:4 on brick surface finished even and smooth without using extra cement including in patches complete all as specified and as directed. |
| 58 | Supply and fix GI wire netting 0.90mm dia and 12mm mesh lathing to RCC Beam/Column- Bk Wall junction including all laps, cutting and waste and taking down old U/s wire mesh of any description complete all as specified and as directed |
| 59 | Material and labour for 10 mm thick cement plaster in Cement Mortar 1:4 as in dado/wall tiles complete all as specified and as directed. |
| 60 | Material and labour for screed bed or bedding layer of mortar 15 mm thick for laying floor finished in Cement Mortar 1:6 complete all as specified and as directed. |
| 61 | WHITE WASHING, COLOUR WASHING AND DISTEMPERING WORKMaterial and labour for preparing new plastered surface on wall and applying two coats of oil bound distemper over a coat of one coat of priming plastered and other surfaces with alkali-resistant priming paint laid over 3mm thick putty finish complete all as specified and directed. |
| 62 | Material and labour for preparing new plastered surface on ceiling and applying two coats of oil bound distemper over a coat of one coat of priming plastered and other surfaces with alkali-resistant priming paint laid complete all as specified and directed. |
| 63 | Material and labour for complete removal of existing surface treatment by mechanical grinder so that underneath plaster surface is exposed from old brick/concrete surfaces on walls and applying two coats of oil bound distemper aid over 3mm thick putty finish complete all as specified and directed. |
| 64 | Material and labour for preparation of old plastered surface of ceiling and applying two coat of oil bound distemper complete all as specified and as directed. |
| 65 | Material and labour for preparing new plastered surface of walls and applying two coats of Cement Based Paint over a coat of one coat of priming plastered and other surfaces with alkali-resistant priming paint laid complete all as specified and as directed . |
| 66 | Material and labour for preparing old plastered surface of walls and applying two coats of Cement Based Paint over a coat of one coat of priming plastered and other surfaces with alkali-resistant priming paint laid complete all as specified and as directed. |
| 67 | Material and labour for preparing old/new plastered surface of wall and applying two coats of Weather Proof Paint/ Exterior emulsion paint for Blue Colour on facia of chajja over a coat of one coat of priming plastered and other surfaces with alkali-resistant priming paint laid complete all as specified and as directed. |
| 68 | GLAZING WORKSupply and fix toughened glass fix in window with rubber bedding in squares exc. 0.5 Sqm in each pane, thickness in 6 mm complete all as specified and as directed. |
| 69 | Supply and fix toughened glass fix in window with rubber bedding in squares not exc. 0.5 Sqm in each pane, thickness in 6 mm complete all as specified and as directed. |
| 70 | PAINTING WORKMaterial and labour for preparation of new steel and iron surfaces of any description, over 10 cm in width or girth and applying 2 coats of synthetic enamel paint over one coat of red oxide primer complete, all as specified and as directed. |
| 71 | Material and labour for preparation of old steel or iron surfaces of any description, over 10 cm in width or girth and applying one coats of synthetic enamel paint complete, all as specified and as directed. |
| 72 | WATER SUPPLY, PLUMBING AND SANITARY APPLIANCES WORKMaterial and labour for 40mm dia medium grade GI pipe as in spouts /short length including holes in embedded sunken portion complete all as specified and directed. |
| 73 | Supply and fix in repair 100 mm cast iron soil waste and vent pipe in any length with or without ears jointed with cement mortar (1:3) fixed to wall , laid in trenches or in floors, complete all as specified and directed. |
| 74 | Supply and fix in repair 75 mm cast iron soil waste and vent pipe in any length with or without ears jointed with cement mortar (1:3) fixed to wall , laid in trenches or in floors, complete all as specified and directed. |
| 75 | Supply and fix 100 mm cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) including taking down existing pipe complete all as specified and directed. |
| 76 | Supply and fixing 100 mm dia centrifugally cast CI branch piece (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branch complete all as specified and directed. |
| 77 | Material and labour for 75 mm dia centrifugally cast iron floor trap/nahani trap with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B1 using 20 mm graded crushed stone aggregate complete all as specified and directed. NOTE :- Trap shall be sealed properly with the existing pipe and got tested by filling with water. |
| 78 | Supply and fixing PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints, fixed to walls with MS clamps complete all as specified and as directed. |
| 79 | All as per item No 78 above but 75mm dia. |
| 80 | Supply and fixing PVC (SWR) bend 110 mm dia complete all as specified and directed. |
| 81 | All as per item No 80 above but 75mm dia. |
| 82 | Supply and fixing 75 mm dia centrifugally cast CI branch piece (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branch complete all as specified and directed. |
| 83 | Taking down steel tubing of 15 mm bore and connections from walls and ceilings or laid in floors including cleaning for refixing in same position (walls/ceilings/floors etc.) complete all as specified and directed. |
| 84 | All as per item No 83 above but 20mm bore of pipes. |
| 85 | Supply and fixing galvanized iron tubes 15 mm bore medium grade with all fittings and fixtures such as bends, elbows, tees, short pieces, back nuts, connectors, diminishing pieces, caps, pegs and clamps, union etc. laid in walls/floors/ceilings as in concealed work including cutting chases in wall and making good surface complete all as specified and directed. |
| 86 | All as per item No 85 above but 20mm bore . |
| 87 | Supply and fix in repairs 15mm bore angle/stop valves fancy brass chromium plated, screwed down, high pressure with crutch or butterfly handles screwed both ends for iron pipes complete all as specified and directed. |
| 88 | Supply & fix in repairs 15 mm bore Bib taps, long shank chromium plated cast copper alloy with fancy type crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified and directed. |
| 89 | Supply & fix in repairs 15mm bore fancy type Bib taps short body , cast copper alloy, with capstan head, chromium plated, screwed down high pressure and fly nuts screwed for iron pipes and fixed complete all as specified and directed. |
| 90 | Supply and fixing in repair cast copper alloy CP angle valve stop cock with flange suitable for 15 mm bore pipe screwed at both ends, high pressure with capstan heads complete all as specified and directed. |
| 91 | Supply and fix in repairs 15mm bore fancy type pillar taps, cast copper alloy, with capstan head, chromium plated, screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipes and fixed complete all as specified and directed. |
| 92 | Supply and fixing in repairs 20 mm dia Gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 93 | Supply and fix in repair PVC connection 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed. |
| 94 | Supply and fix in repair PVC waste pipe 32 mm bore with 80cm long flexible for WHB complete all as specified and directed. |
| 95 | Supply and fix in repair PVC waste pipe 40 mm bore with 80cm long flexible for sink complete all as specified and directed. |
| 96 | Supply and fix in repair waste coupling of PTMT (half or full threaded) 32 mm bore (minimum weight 45 gms) complete all as specified and directed. |
| 97 | Supply and fix in repair waste coupling of PTMT (half or full threaded) 40 mm bore (minimum weight 60 gms) for steel sink complete all specified and as directed. |
| 98 | Supply and fixing in repairs 600 x 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 99 | Supply and fixing in repair tubular towel rail, 20 mm dia, D type, 60 cm long between flanges of brass chromium plated fixed with and including CP brass screws in cleats (minimum weight 90 gms) complete all as specified and directed. |
| 100 | Supply and fixing in repairs CP brass shower rose of size 125 mm square/circular as approved, swivel type with CP extension rod 15 mm dia and 200 mm long suitable for 15 mm bore pipe complete all as specified and directed. |
| 101 | Supply and fixing in repairs 10 litres capacity PVC valveless symphonic action type flushing cistern high/low level white complete with inlet, ball valve, float and handle including brackets and telescopic down flush pipes and jointing with WC complete all as specified and directed. |
| 102 | Supply and fixing in repairs Vitreous China wash hand basin, white,flat back size 550mmx400mm including fixing cantilever 02 Nos brackets of angle 30mmx30mm thickness 4mm, 500mm long with PCC 1:2:4 type B0 in wall complete all as specified and directed. |
| 103 | Supply & fix in repair kitchen sink with drainage board made of stainless steel 1.0 mm thick in kitchen with plug , washer and waste including bedding layer in CM (1:6) in wall as with fixing cantilever bracket and connecting union to pipes over all size 915x460 mm bowl size 410x330x160 mm including taking out unserviceable kitchen sink complete all as specified and directed. |
| 104 | Supply and fixing in repairs stainless steel plate rack SS 304 grade of size 31\\" x 24\\" x 10\\" (or above) with using stainless steel sheet of 0.63 mm thickness, provided with brass screw including necessary fittings, nuts/bolts complete all as specified and as directed. NOTE :- The plate rack shall be of 1st quality and weight and composition of SS shall be as per relevant IS. |
| 105 | Supply and fixing in repairs 500 litre capacity rotational moulded polythene water storage tank (cylindrical vertical with closed top) three layered hoisted and fixed in position complete including dismantling existing water tank & removing to store complete all as specified and directed. |
| 106 | Supply and fixing Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of 20 mm bore (minimum weight 210 gms) and fixed complete all as specified and directed. |
| 107 | Material and labour for disconnecting of PVC tank of capacity 500 Ltrs & upto 1000 Ltrs for cleaning complete all as specified and directed :-a) Dewatering & removing all settled silt, scale & dust from inside of tanks using coconut brush manually and applying bleaching powder and allowed to rest for 1 hour.b) Cleaning & rinsing the tank using fresh water to wash out complete and allowed to dry for 30 mins.c) Writing letters of 7 cm height using synthetic enamel paint (white colour) to mention date of cleaning incl rubbing out old letters written over the tankd) Refixing the tank in same position or raised/lower height after cleaning or water proofing treatment (as may necessary) complete all as directed.Note : - Water proofing treatment, PCC bench, below the tank if required to be repaired, shall be measured and paid separately under relevant items. |
| 108 | ELECTRIFICATION WORKTaking down carefully (copper/aluminum) unserviceable point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point ,socket point or power point including fixture and fitting such as switches , ceiling roses, pendants , regulators , sockets , light fitting etc. removing material to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making good the disturbed surfaces of wall/floor or ceiling to match with existing surface and finishing the surfaces with distemper/white washing/colour washing as per existing complete all as specified and directed. . |
| 109 | Taking down carefully by submain wiring/service connection of any complete all as specified and as directed. |
| 110 | Taking down carefully DB box of any sizes & capacity complete all as specified and directed. |
| 111 | Material and labour for concealed Point wiring with 1.5 Sqmm (nominal area) single core PVC insulated unsheathed (FRLSH) cable, multi-stranded, copper conductor, in universal colour code with & including suitable size of rigid non-metallic UPVC conduit (not less then 20mm dia medium grade) and its all accessories complete concealed in wall / roof including cutting & chases and modular flush metal boxes 0.8 mm thick suitable for modular fittings including modular outer cover plate with inner mounting frame as per site requirement for mounting modular switches, sockets etc for one light/fan/call bell point controlled by one switch including earth wire of PVC insulated (FRLSH) copper conductor multistranded of 1.5 Sqmm size in green colour including making good disturbed surface (i.e plastering ,one coat of putty and two coats of Old Bound Distemper paint with matching existing surface), complete all as specified and as directed. |
| 112 | All as per item no 111.00 above but for One light/fan point controlled by one switch. |
| 113 | All as per item no 111.00 above but for One 3 pin socket outlet 5 Amp on same board. |
| 114 | All as per item no 111.00 above but for One light point controlled by 2, two switches. |
| 115 | All as per item no 111.00 above but for One bell point controlled by one switch. |
| 116 | All as per item no 111.00 above but 2.5 Sqmm copper conductor cable and 2.5 sqmm PVC insulated standard copper conductor complete FRLS cable as continuous earth wire all as specified for One 3 pin socket outlet 15 Amp on independent board. |
| 117 | Material and labour for sub main wiring with two single core PVC insulated unsheathed stranded copper conductor FRLS cable 6 Sqmm and including UPVC conduit with all fittings medium grade ISI Marked and PVC insulated FRLS copper conductor cable of size 6 sq mm as earth wire, connected to common earth dolly and all metal part/main switch making good disturbed surface (i.e plastering ,one coat of putty and two coats of old bound distemper paint with matching existing surface) complete all as specified and as directed.NOTE :- Two runs of single core PVC insulated standard copper conductor and one run of earth wire shall be measured as one unit. |
| 118 | Material and labour for sub main wiring with two single core PVC insulated unsheathed stranded copper conductor FRLS cable 4 Sqmm and including UPVC conduit with all fittings medium grade ISI Marked and PVC insulated FRLS copper conductor cable of size 4 sq mm as earth wire, connected to common earth dolly and all metal part/main switch making good disturbed surface (i.e plastering ,one coat of putti and two coats of old bound distemper paint with matching existing surface) complete all as specified and as directed.NOTE :- Two runs of single core PVC insulated standard copper conductor and one run of earth wire shall be measured as one unit. |
| 119 | Supply and fix in replacement of modular switch, 1 module single pole one way 6 Amp complete all as specified and as directed. |
| 120 | Supply and fix in replacement of modular switch, 1 module single pole one way 16 Amp complete all as specified and as directed. |
| 121 | Supply and fix in replacement of modular switch, 1 module single pole two way 6 Amp complete all as specified and as directed. |
| 122 | Supply and fix in replacement of modular bell push, 1 module single pole one way 6 Amp complete all as specified and as directed. |
| 123 | Supply and fix in replacement of socket outlet 3 pin 6 amp multipurpose, modular type, 2 module, 240 volt complete all as specified and as directed. |
| 124 | Supply and fix in replacement of socket outlet 3 pin 6/16 amp multipurpose, modular type, 2 module 240 volt complete all as specified and as directed. |
| 125 | Supply and fix in replacement of sheet metal including single pole and neutral with 02 pin and earth plug and socket complete with 01 single pole 20 Amps 240 volts, MCB including necessary fixing arrangement and all incoming and outgoing electric connections , complete all as specified and as directed. |
| 126 | Supply and fix in replacement of Ceiling rose surface Bakelite 65 x 50 mm 2/3 terminals complete all as specified and as directed. |
| 127 | Supply and fix in replacement of Bell ding dong, Type AC 230 volts, 50Hz, Single Phase , complete all as specified and as directed. |
| 128 | Supply and fixing in repairs MCB SPN 40 Amps, 240 volts, 10 KA, 'C' series with short circuit indication type complete all as specified and as directed. |
| 129 | Supply and fixing in repairs MCB SP 6 to 32 Amps, 240 volts, 10 KA, 'C' series with short circuit indication type complete all as specified and as directed. |
| 130 | Supply and fixing in repairs sheet metal enclosure DB SPN with 100 Amps IP 43 rated bus bars, 8 way, 240 volts for independent mounting complete all as specified and as directed. |
| 131 | Supply and fixing in replacement of wall mounted fittings with ABS housing and clear polycarbonate cover including retrofit LED bulb 09 watt conforming to city-1/city-2 including making connection with flexible copper 3 core cable 0.5 Sqmm from connector/ ceiling rose to fitting complete all as specified and directed. |
| 132 | Supply and fixing in replacement of LED batten four feet ,1200 mm length , polycarbonate body , 20 Watt,100 Lumen/watt , total Lumen 2000 , cool day light fixed on wall including cord cable 0.50 Sqmm 2 core upto 300 mm length complete all as specified and directed. |
| 133 | Supply and fixing in replacement of LED batten Two feet ,600 mm length , polycarbonate body ,10 Watt ,100 Lumen/watt ,total Lumen 1000 , cool day light fixed on wall including cord cable 0.25 Sqmm 2 core upto 300 mm length complete all as specified and as directed. |
| 134 | Supply and fixing in replacement of LED Bulk head Luminaire made of pressure die cast aluminium hosing with protected diffuser 10 watt system wattage , colour temp 6500K, Lumen efficacy 100 lumen/watt, total Lumens output 1000, PF >0.9 complete all as specified and directed. |
| 135 | Supply and fixing in replacement of LED batten one feet ,300 mm length ,polycarbonate body ,5 Watt,100 Lumen/watt , total Lumen 500 , cool day light fixed on wall including cord cable 0.25 Sqmm 2 core upto 300 mm length complete all as specified and as directed. |
| 136 | Supply and fixing in replacement of LED building security light fitting 30W powder coated, pressure die cast aluminium body and polycarbonate cover with individual LED lense having colour temperature 6500 +/- 500, PF >0.90 having system efficiency 2400 lumen with all accessories such as connection, nut and bolt etc, complete all as specified and directed. |
| 137 | Supply and fixing exhaust fan 250 mm sweep made of sturdy engineering plastic complete with louvres shutters, voltage 230 volts, 50 Hz, RPM 1200, copper winding with all accessories including hanging in position and connecting with 3 core of size 0.50 Sqmm copper conductor PVC insulated and PVC sheathed round cable from ceiling rose to fan complete all as specified and as directed. |
| 138 | Disconnecting all existing electric supply and taking down carefully ceiling/fan of any make and sweep, dismantling blades, carrying out minor repairs at site for functioning of fan, scraping down old paint, rust, dirt, grease etc. cleaning and preparation of motors and blades surfaces and spray painting with two coats of approved synthetic enamel paint and hanging /refixing in position complete all as specified and as directed |
| 139 | Material and labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI wire 4.0mm dia as earth lead by means of bolts, nuts, washers and check nuts of galvanized steel, protected by and including GI pipe 15 mm bore, light grade and connected to main switch/MCB DB box point/LP test point as directed and including cement concrete pit 1:2:4 type B0 using 12.5 mm graded crushed stone aggregate with cast iron/mild steel frame embedded in the concrete enclosure finished flushed & CI cover 10 mm thick of size (300 mm x 300 mm CI) having locking arrangement hinged to CI frame all as shown in electrical plate No 3 of MES Schedule Part I and as directed including painting the external surface of chamber & cover with synthetic enamel paint in different colour as directed and writing earth results & date of test carried out with white paint on black painted background, wire mesh, funnel 20 mm bore GI pipe light grade for watering adequate quantity of charcoal and common salt in alternate layer of 15 cm thick all around the electrode including necessary & earth work in any type of soil complete testing on completion complete all as specified and as directed.NOTES :-(i) Filling the pit with black cotton soil brought at site.(ii) Quantity of GI wire and protection pipe beyond 7.5 m length shall be measured separately.(iii) Testing on completion and submitting report to Engineer-in-Charge. |
| 140 | DEMOLITION AND DISMANTLING WORKDemolition of lime concrete / lean concrete /Brick bats etc. from sunken slab portion exc. 15cm thick but above ground floors, complete all as specified and directed by Engineer-in-charge including removal of demolished material from MD land where complete all as specified and directed |
| 141 | Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 142 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. complete all as specified and as directed. |
| 143 | Dismantling bricks tiles/cement tiles or terracing tiles single layer on roofs and including removing the waste materials to a distance of 500 meters, complete all as specified and as directed. |
| 144 | Demolition of mud phuska on roofs any thickness including mud plastering (whether full thickness removed or only a part thereof) and removal off the existing premises, complete all as specified and as directed. |
| 145 | Demolition of RCC roofs, floors (other than ground floors), beams staircases, landing, chajjas, and similar suspended work at any height complete all as specified and as directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail