| 1 | Dismantling AC sheet (Corrugated, Semi Corrugated etc) as in roofs etc including ridges complete all as specified. |
| 2 | S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 3 | S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 4 | M & L for roughening the surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and directed. |
| 5 | S & F vitrified tiles dark shade digital tiles/(double charged), 10mm thick (square/ rectanglar) polished, exceeding 0.42 sqm of each tiles not exceeding 1.00 sqm, in floors etc laid over and including 15mm thick screed bed 1:6, set and jointed in neat cement slurry and pointed in white/coloured cement to match complete all as specified. |
| 6 | Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thick (Below or above ground level) complete all as specified and directed. |
| 7 | M & L for 75 mm thick cement concrete 1:3:6 type C-2, using 40 mm graded stone aggregate as in plinth protection laid to slop of 1:12, finished surface even and fair without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 6 mm wide joints through out the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and directed. |
| 8 | M & L for providing plain cement concrete, type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges with and including necessary form work as required complete all as specified and directed. |
| 9 | Demolition of reinforced cement concrete in any position and any description including cutting of reinforcement bars to facilitate demolition complete all as specified and directed. |
| 10 | M&L for reinforced cement concrete 1:11/2:3 (Nominal mix) using 20 mm graded aggregates as in lintel & Chajja supported on walls mixed with liquid water proofing compound (Liquid water proofing compound to be measured paid separately) complete all as specified and directed. |
| 11 | M & L for mild steel TMT bars 6 to 8 mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 12 | M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 13 | M & L for use and waste of form work to chullah hoods, chajjas, troughs and similar items including edges in rough finished surface of concrete complete all as specified and directed. |
| 14 | Dismantling of timber scantling 40 Sqcm and over in section, in any position as in unframed or framed work complete all as specified and directed. |
| 15 | S & F of rolled mild steel sections as in roof trusses (framed), trussed, purlins, crane gantry, rails, fastening, heavy bracket framing (Beam, tee, angle, channel or flat section), including distance pieces, cleats etc. confirming to Fe – 410 – S including cutting, welding etc. complete all as specified and directed. |
| 16 | M & L for preparation of new or previously untreated steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 17 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness including cover filltets complete all as specified and directed. |
| 18 | M & L for fixing of E-board of size 600 x 600 x 4mm thick white prelaminated self embosed reinforced desigener ceiling board/tiles at any height laid on Hot dipped Galvanised imposed grid with 24mm wide T-section exposed flanges which shall be powder coated white. The frame work will comprise of main runner made from 0.33mm thick GS sheet and of size 24x32x3000mm and spaced at 1200mm centers securely fixed to the structural soffits by approved hangers at 1200mm maximum centers and inlcuding Hangers of GI wire 4mm dia shall be fixed by rawl plugs, level and justers and screws etc complete all as specified and directed. |
| 19 | Taking down chawkhat frame with shutter (without taking out shutter from the frame) exc 1.50 Sqm but n. exc 4 sqm each and removing from site complete all as specified and directed. |
| 20 | M & L for providing and fixing powder coated aluminium partly glazesd and partly paneled door shutter side hung type using 1.50mm thick standered door section having size of styles, top rails 83x44mm where as bottom rails will be made up of 100x44mm including necessary joining cleats glazing clips, rubber packing, anodized aluminium snap beading screws, anodized aluminium fittings such as 100mm long 3 No. aluminium hinges B-21 ,type 01 No. aluminium tower bolt 200mm long and one no mortise lock 100mm size 4 levers (vertical type) and 01 No 300mm size long aluminium sliding bolt and 02 No fancey type fiber glass 150mm dia circular handle shall be provided to each door and glazing of top panel shall be made of 5.50 thick sheet glass and pannelling shall be provided with 12mm thick exterior grade pre laiminated partical board with both side choice lamination complete as specified and directed. |
| 21 | S&F powder coated alumium glazed window shutter sliding type using 1.30 mm thick aluminium open three track section having size of style & top rails 83x44mm, bottom rils 100x44mm including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading screws, anodised aluminium fittings complete and glazing shall be done by using 5mm thick plain sheet glass and stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm complete as specified and directed. |
| 22 | S & F powder coated aluminium Grill (anodised transparent of dyed to required shade according to IS-1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the exiting window frame with CP brass/stainless steel screws @200 mm centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as per requirement and direction of Enginer-in-charge. |
| 23 | S & F of collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed. |
| 24 | S & F of 1.25 mm thick pressed steel frame of size 105 X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates etc complete all as specified and directed. |
| 25 | S & F Factory made 30 mm thick 100% solid WPC (Wood Polymer Composite) solid both side prelam 14 micron Flush door shutter wit 10mm deep CNC moulding design of required size comprising of virgin PVC resin of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately) |
| 26 | S&F 300 mm long Stainless steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed. |
| 27 | S&F for 200 mm long Stainles steel barrel tower bolts, stove enamelled black, with bright bolt and fixed of extruded section and fixed complete all as specified and directed. |
| 28 | S&F 125 mm size Stainless steel handles fabricated type extruded section ,ISI marked complete all as specified and directed. |
| 29 | S&F Butt hinges 125 mm stainless steel hinges medium weight and fixed complete all as specified and directed. |
| 30 | Demolition of brick work or stone / boulder masonry including all quoins, arches, pillars, etc. built in cement mortar or cement lime mortar complete all as specified and directed. |
| 31 | M & L for brick work with sub class ‘B’ old size bricks straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:4 complete all as specified and directed. |
| 32 | Taking down cement or cement lime plaster including tiles if exists, from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. including removing of rubbish off the premises complete all as specified and directed. |
| 33 | M & L for 15 mm thick rendering on fair faces of brick work or concrete surfaces with cement mortar 1:4 finished even and fair complete all as specified and directed. |
| 34 | M & L for 15 mm thick rendering on other than fair faces of brick work or stone masonry surfaces with cement mortar 1:6 finished even and fair complete all as specified and directed. |
| 35 | M & L for preparation of newly plastered surfaces and applying two coat of oil emulsion distemper (OBD) over 2 mm wall care putty on wall of approved shade/tint all as specified & as directed. |
| 36 | M & L for preparing newly plastered or previously untreated wall surfaces and applying two coats of cement base paint over one coat of primer complete all as specified and directed. |
| 37 | Taking down carefully surface aluminium or copper point wiring (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, regulators, sockets etc and making good disturbed surfaces even and smooth using CM 1:3 including white/colour wash to match the existing surface complete all as specified and directed. |
| 38 | M & L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm and earth continuity conductor with 1.5 sqmm using colour code drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 25 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken modular GI metal boxes 1.0 mm thick with 3 mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified for the following:- One light point controlled by one switch. |
| 39 | All as per item No 38 as above but one socket outlet 6 A controlled by one switch on indepdendent board. |
| 40 | All as per item No 38 as above but one socket outlet 6 A controlled by one switch on the same board with other switches. |
| 41 | M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 2.5 sqmm and earth continuity conductor 2.5 sqmm colour coded drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 25 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of thickness not less than 1.0 mm with 3 mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified |
| 42 | Supply and fix switch piano flush type, 06 Amp, single pole, one way, 230 Volt complete all. |
| 43 | Supply and fix socket outlet 2 in 1, 5 pin, 06 Amp, flush type, 230 volt complete all. |
| 44 | Supply and fix switch socket combination outlet 2 in 1, 3 pin, 06 Amp and 16 Amp flush type, universal, 230 volt, four hole complete all. |
| 45 | S & F in repairs of LED surface mounted batten 20 watt, powder coated die cast/ extruded aluminium Body (Thickness ≥ 1.20 mm) or CRCA sheet body (Thickness ≥ .50 mm) and System lumen efficacy 120 lm/Watt output and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50 Hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5%), life time (LED electrical circuitary), of minimum 50000 burning hours with 70% of initial Lumen maintained till life ends, CCT 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and fixture shall be of relevant BIS standard and trade mark certificate and Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing complete in all respect including connections with suitable size FRLS, PVC insulated copper conductor cable complete all as specified and directed.Note:- Heat sink of aluminum housing should be such that LED junction temperature shall not rise above 90°C. |
| 46 | Supply and fixing round shape 12 Watt 220V, AC recessed type with high efficency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 47 | S&F in repair LED security light fixture 35 watt powder coated pressure die cast aluminum body with driver Input voltage: 140-270 Volt AC, 50 Hz, operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency > 85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >80, System lumen efficacy ≥105 <120 lm/Watt output, under voltage and over voltage protection, EMIEMC as per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the requirement, life time (LED & electrical circuitry) of minimum 50000 burning hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and fixture shall be of relevant BIS standard complete in all respect including connections with suitable size FRLS, PVC insulated copper conductor cable complete all as specified and directed.Note:- Heat sink of aluminum housing should be such that LED junction temperature shall not rise above 90°C. |
| 48 | Supply and fix ceiling rose, 6 Amp, 250 volt, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25 mm size complete all as specified & directed. |
| 49 | Supply and fix in repairs 4 way TPN DB with 415 Amps rated bus bar 240Volt, Double door type complete all as specified & directed. |
| 50 | S & F in repairs TPN miniature circuit breaker (MCB) 'C' curve of 440V, 10kA 40-100 Amp current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 51 | Supply and fixing MCB SP 6-32 Amps240 V, C- curve, 50 Hz, breking capacity-10 kA . complete all. |
| 52 | Material and labour for earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete all as specified and directed. |
| 53 | Supply, laying and testing cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size cross sectional area 25 sqmm 4 core complete all as specified and directed. |
| 54 | Excavation in trenches soft/loose soil not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of pipes/cables etc getting out and bottom surface to required gradient complete. |
| 55 | M & L Returning filling in including spreading leveling watering and well ramming in layers each not exceeding 25 cm thickness complete. |
| 56 | M & L Removal of surplus spoil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete. |
| 57 | Supplying, filling in trenches, spreading, leveling sand cushioning 8 cm below cable and 15 cm above the cable for under ground cable complete all as specified & directed. i.e 18 cm punned down thick shall be considerd for mesurement) |
| 58 | M & L Old size sub class 'B' bricks,laid flat in trenches over the cable with length of brick perpendicular to the direction of the cable adjacent/abutting each other complete. Please Enable Macros to View BoQ information |