| 1 | ITEM NO: 1 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means |
| 2 | ITEM NO: 2 Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling. ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means (SSR Item No: 21.06) (PWD-CIVIL SSR) Item Spec: (Bd.A.2 Page One Number 259) |
| 3 | ITEM NO: 3Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) (Non SCADA Iterm) |
| 4 | ITEM NO: 4 Providing and laying in situ /Ready Mix cement concrete M-20 of trap/granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) (Non SCADA Item) |
| 5 | ITEM NO: 5 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)(Concrete Non Scada) |
| 6 | ITEM NO: 6 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping. compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based C with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sarid VSI Grade) (Non SCADA Item) |
| 7 | ITEM NO: 7 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) (Non SCADA Item) |
| 8 | ITEM NO: 8 Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/quartzite/granite/gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block). (Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) (Non SCADA Item) (SSR Item No: 26.25) (PWD-CIVIL SSR) Item Spec: (Bd. F. 13 Page One Number 305 /I.S. 456 (2000) |
| 9 | ITEM NO: 9 Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)(Concrete Non Scada) |
| 10 | ITEM NO: 10 Providing and fixing in position TMTFE 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations. slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 11 | ITEM NO: 11 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually, striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete |
| 12 | ITEM NO: 12 Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete. (SSR Item No: 21.36) (PWD-CIVIL SSR) Item Spec: (Bd.A.10 Page One Number 262) |
| 13 | ITEM NO: 13 Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. (SSR Item No: 21.37) (PWD-CIVIL SSR) Item Spec: (Bd.A.11 Page One Number 263) |
| 14 | ITEM NO: 14 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete (SSR Item No: 27.05) (PWD-CIVIL SSR) Item Spec: (Bd.G.5 Page One Number 315) |
| 15 | ITEM NO:15 Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete (SSR Item No: 32.02) (PWD-CIVIL SSR) Item Spec: (Bd.L.1 Page One Number 367) |
| 16 | ITEM NO: 16 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. (SSR Item No: 32.04) (PWD-CIVIL SSR) Item Spec: (Bd. L.2 |
| 17 | ITEM NO: 17 Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete. (SSR Item No: 32.15) (PWD-CIVIL SSR) Item Spec: (Bd. L.10. |
| 18 | ITEM NO: 18 Providing and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to 1.5. 65241983 having 6 mm dia, bars 3 Nos. And stirrups @250 mm c/c and fixing in wall with 6 Nos of hold fast of 12 mm dia bars 500 mm long including primer and oil painting etc, complete) frame size 60 mm x 100 mm. |
| 19 | ITEM NO: 19 Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border/messages/symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge (SSR Item No: 6.36) (PWD-CIVIL SSR) Item Spec: (MORTH 801 |
| 20 | ITEM NO: 1 BASIC TEST OF AGGREGATE. 2)Sieve Analysis. (SSR Item No: 99.03) (PWD-CIVIL SSR) Item Spec: (1 |
| 21 | ITEM NO: 2 CONCRETE. 1)Compressive Strength OF C.C. Cube (Set of 3 cubes). |
| 22 | ITEM NO: 3 BRICKS. 1)Water Absorption (Set of 5 Bricks), Compressive Strength(Set of 5 Bricks), Efflorescence (Set of 5 Bricks) (SSR Item No: 99.13) (PWD-CIVIL SSR) Item Spec: () |
| 23 | ITEM NO: 4 MORTOR. 1) Compressive Strength. (Set of 3 Cubes) (SSR Item No: 99.27) (PWD-CIVIL SSR) Item Spec: () |
| 24 | ITEM NO: 5 SOIL/MURUM. 1)Sieve Analysis (SSR Item No: 99.29) (PWD-CIVIL SSR) Item Spec: () |
| 25 | ITEM NO: 6 STEEL BAR TESTING.1) Upto 16 mm (Set of 3 Bars) (SSR Item No: 99.72) (PWD-CIVIL SSR) Item Spec: () |
| 26 | ITEM NO: 1 Royalty For Natural Sand - Screened (for plaster work only) |
| 27 | ITEM NO: 2 Royalty For Soft Murum Please Enable Macros to View BoQ information |