| 1 | Demolition of wall and ceiling boards (fibre, pulp, gypsum, POP, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets and metal frame work complete all as specified and directed. |
| 2 | S&F Solid PVC wall lining consisting of 5mm thick any colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame, PVC strip etc fixing as wall panelling up to ceiling level all included as per specification SSR part-I, complete all as specified. |
| 3 | S&F 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on wall to make PVC frame, complete all as specified and directed. |
| 4 | S&F powder coated GI snap grid frame work of size 605mm x 605mm for false ceiling complete with accessories all as specified and shown in MES SSR Part-II, complete all as specified and directed. |
| 5 | S&F Gl frame work for seamless ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx. 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed. |
| 6 | S&F hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. |
| 7 | M&L for 4 mm thick asbestos fibre cement building board, cut to size and fixed in grid frame work ceiling as panels, complete all as specified and directed. |
| 8 | M&L for Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions including two oats of interior acrylic distemper/oil bound distemper over a coat of putty filling on gap ceiling surfaces complete all as specified and directed. |
| 9 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 10 | S&F galvanised corrugated mild steel sheeting 0.63mm thick with two corrugations side lap fixed with galvanised mild steel L / J type hook including washer etc as in roofs, walls, gates cladding of hanger / BPs with grade of zinc coating 275 etc. complete all as specified and directed. |
| 11 | S&F Galvanised corrugated mild steel sheeting (Except sheeting any thickness) with two corrugations side lap fixed with galvanised mild steel L / J type hook including washer etc as in roofs, walls, gates cladding of hanger / BPs complete all as specified and directed. |
| 12 | S&F plain, galvanised, mild steel sheeting 0.63mm thick, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275, complete all as specified and directed. |
| 13 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc. complete all as specified and directed. |
| 14 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet (Except sheeting any thickness) as in roof covering/cladding to wall, fixed with self tapping screws etc. complete all as specified and directed. |
| 15 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 16 | Dismantling of Asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings complete all as specified and directed. |
| 17 | S&F 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc. fixed with galvanised mild steel L / J type hook or cranked hook bolts including washer etc complete all as specified and directed. |
| 18 | S&F 6mm thick asbestos cement, corrugated or semi-corrugated sheets (Except sheeting any thickness) in roofs, walls etc. fixed with galvanised mild steel L / J type hook or cranked hook bolts including washer etc complete all as specified and directed. |
| 19 | S&F asbestos cement two piece adjustable plain wing ridge 6mm thick serrated ridge for corrugated or semi corrugated sheets .fixed with galvanised mild steel L / J type hook or cranked hook bolts including washer etc complete all as specified and directed. |
| 20 | Excavating in post holes in soft /loose soil (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed. |
| 21 | M & L for Cement concrete 1:3:6 type C2 using 40 mm graded stone aggregates in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed. |
| 22 | M&L for 50 mm thick Cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in floor, complete all as specified and directed. |
| 23 | M&L for 75 mm thick Plain Cement Concrete 1:2:4 type B-2 using 20mm graded crushed stone aggregate as in flooring / hard standing etc. complete all as specified and directed. |
| 24 | M&L for Two coats of synthetic enamel paint over new steel & iron surfaces of any description, not otherwise described, over 10 cm in width or girth, over a coat of red oxide primer including preparation of new surfaces , for height not exceeding 8.50 metre complete all as specified and directed. |
| 25 | S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 26 | S & F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts. posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 27 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified and directed. |
| 28 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 29 | M & L for Granite (of any type) slabs 12 to 15 mm thick machine cut, bedded and jointed with grey cement slurry as in flooring, cooking shelves etc. and pointed with white cement with admixture of pigment to match the shade granite stone including grinding and polishing over and including 15mm thick screed bed in Cement Mortar 1:4 in floors etc complete all as specified and directed. |
| 30 | M & L for 12 to 15 mm thick Granite (of any type) tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including 10 mm thick (average thickness) cement mortar (1:3) and jointed with grey cement slurry mixed with pigment to match the shade of the slab complete all as specified and directed. |
| 31 | M & L for First quality, Vitrified Ceramic(Double Charged) tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. over including white or coloured cement to match the shade of tile laid over and including 10mm thick rendering in cement mortar (1:4) including necessary cutting as per site requirement , set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade, complete all as specified and directed. |
| 32 | M & L for First quality, vitrified ceramic(Double Charged) coloured tiles 9-10mm thick, of size exceeding 0.42 sqm but not exceeding 1.00 sqm, on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 10mm thick rendering in cement mortar (1:4) including necessary cutting as per site requirement, complete all as specified and directed. |
| 33 | Demolition of cement concrete in ground floors and pavings n exc 15cm thickness (below or above ground level) and removing demolished material from site to a distance exceeding 1.50 Km and not exceeding 5 Km and depositing where directed by Engineer-in-Charge. |
| 34 | M & L for 75mm thick plain cement concrete 1:4:8 type D2, using 40mm graded stone aggregate as in sub base complete all as specified and directed. |
| 35 | M & L for 25mm thick plain cement concrete 1:2:4 type B1, using 20mm graded stone aggregate as in sub base complete all as specified and directed. |
| 36 | M&L for 60mm thick Machine pressed precast interlocking (M-35) cement concrete tiles (Coloured) of approved design & pattern laid over and including Fine sand filling under floor in layers not exceeding 25cm each layer including watering and well ramming as per site requirement complete all as specified and directed. |
| 37 | M&L for 80mm thick Machine pressed precast interlocking (M-40) cement concrete tiles (Coloured) of approved design & pattern laid over and including Fine sand filling under floor in layers not exceeding 25cm each layer including watering and well ramming as per site requirement complete all as specified and directed. Please Enable Macros to View BoQ information |
| 38 | M&L for 80mm thick Machine pressed precast interlocking (M-40) cement concrete tiles (Coloured) of approved design & pattern laid over and including Fine sand filling under floor in layers not exceeding 25cm each layer including watering and well ramming as per site requirement complete all as specified and directed. Please Enable Macros to View BoQ information |