| 1 | Dismantling of bricks (laid flat or on edge) or brick tiles bedded and pointed in cement mortar as in floors / slabs, channels, kerbs, aprons etc complete all as specified and directed. |
| 2 | Taking down cement or cement lime plaster including tiles if exists, from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. including removing of rubbish off the premises complete all as specified and directed.. |
| 3 | M & L for 15 mm thick rendering on fair faces of walls of brick work or concrete surfaces with cement mortar 1:4 finished even and fair complete all as specified and directed. |
| 4 | M & L for preparing newly plastered or previously untreated wall surfaces and applying two coats of cement base paint over one coat of primer complete all as specified and directed. |
| 5 | M & L for preparation of plastered surfaces and applying two coat of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, over a coat of 2mm thick putty and primer of required shade and colour complete, as per manufacturer's specification complete all as specified and directed |
| 6 | M & L for preparation of plastered surfaces and finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm complete all as specified and directed |
| 7 | M & L for providing plain cement concrete, type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges with and including necessary form work as required complete all as specified and directed. |
| 8 | M & L for rendering 10mm thick on fair faces of concrete surfaces in cement mortar 1:4, mixed with liquid water proofing compound finished even and smooth without using extra cement complete all as specified and directed.Note : Liquid water proofing compound to be measured paid separately |
| 9 | Supply only Liquid water proofing compound complete all as spesified and directed. |
| 10 | M&L for application of high perfomance hybride polyurea elastomeric water proofing coating cold applied, liquid membrane at 1.5 kg/Sqm with an elongation minimum of 500+100% by airless spray machine and tensile strength of minimum 11-13 N/mm2 as per ASTM D2370, crack bridging ability minimum of 3 to 4 mm as per ASTM C1305 , Shore Hardness of minimum 70+5 as per ASTM D2240 complete as per directed by Engr-In-Charge. The System shall also include final base preparation including cleaning of the plaster surface etc and applying epoxy primer as approved makes in two coats at a coverage of 1 kg/Sqm, etc as per manufacturer specification, complete all as specified and directed.Note:- The work petaining to water proofing treatment shall be executed for authorized applicator through manufacture of wich the materials is proposed to be used by the contrator and approved by Garrision Engingeer. |
| 11 | Dismantling AC sheet (Corrugated, Semi Corrugated etc) as in roofs etc including ridges complete all as specified. |
| 12 | S&F of pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in room covering/cladding to wall, including ridge cover fixed with self tapping screws etc all as specifed. |
| 13 | S&F of pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in room covering/cladding to wall, including ridge cover fixed with self tapping screws etc all as specifed. |
| 14 | Dismantling wrought iron or mild steel work of any description complete all as specified and directed. |
| 15 | S&F mild steel rolled/tubular sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters , fixed with angle cleats or other connecting plates etc. conforming to Grade Fe 410W(Gde E-265 quality `B’ all as specified and directed. |
| 16 | M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of zinc chrome primer complete all as specified and directed |
| 17 | S&F 110mm bore PVC (SWR) pipe single socketed in any length with rubber rings joints laid in trenches or wall incl clamp all as specified and directed. |
| 18 | S&F 110mm bore PVC (SWR) bends, any radius. |
| 19 | S & F of 500 Litre capacity triple layared rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of specifications as per MES Schedule 2009, Part – I and hoisted, fixed in position incl dismantiling of old unservicable water tank of any capacity complete all as specified and directed. |
| 20 | S & F of 1000 Litre capacity triple layared rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of specifications as per MES Schedule 2009, Part – I and hoisted, fixed in position incl dismantiling of old unservicable water tank of any capacity complete all as specified and directed. |
| 21 | S&F in repairs 20 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod and high density Plastic ball Screwed for iron pipe and fixed (Minimum weight -210 gms complete all as specified and directed. |
| 22 | Disconnecting existing tank exc. 500 Litre but not exc. 1000 Litre capacity, setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position (cleaning, repairing etc. to be measured separately) complete all as specified and directed. |
| 23 | S & F of 15 mm bore steel water tubing medium grade galvanised with and including all fittings and fixed to walls and ceilings or laid under floors including taking up or down 15mm bore steel water tubing and connection complete all as specified and directed. |
| 24 | S & F of 20 mm bore steel water tubing medium grade galvanised with and including all fittings and fixed to walls and ceilings or laid under floors including taking up or down 20mm bore steel water tubing and connection complete all as specified and directed. Please Enable Macros to View BoQ information |