| 1 | Supplying Installation Testing and Commissioning of 5/6MP IP IR Dome Camera having equivalent or superior specifications and features which are as follows: 5 MP IP IR Motorized Vandal Dome Camera Key Features Motorized Lens 2.8-12mm Up to 2880x1620@30fps H.265+/H.265/H.264 Min. illumination Color : 0.01 lux @ F1.2 (AGC on)/0.004lux @ F1.6 Smart IR, IR Range: Up to 30M Triple-Stream (Main/Sub/Third) SD Card Slot up to 256GB VCA Support Alarm: 1 input / 1 output Audio:1 input (RCA)/ 1 output (RCA) Metal, IP67,IK10 Video Imaging Device 1/2.7\\" Effective Pixels 5MP 2880(H)x1620(V) Scanning System Progressive CMOS Min. Illumination Color 0.01 lux @ F1.2 (AGC on)/0.004lux @ F1.6(AGC ON) ; B/W 0 lux @ IR ON Lens Type Focal Length (Zoom Ratio) 2.8-12mm Max. Aperture Ratio F No. 1.8 (W) ~ 3.3(T) Angular Field of View Horizontal: 107-34°, Vertical: 55-19°, Diagonal: 134-38° Min. Object Distance 0.2M~INF Lens Type Motorized(Ø14) Operational IR Viewable Length Up to 30m Camera Title On/Off Day & Night IR cut filter with auto switch(Day/Night/Auto/Image/Schedule) Backlight Compensation Off/On (5 Zone) Wide Dynamic Range True WDR Digital Noise Reduction 3D DNR Motion Detection Off/On (8 Level) Privacy Masking Off/On (4 Zone, Rectangle) Gain Control Auto White Balance Auto/Manual Electronic Shutter Speed 1/5 ~ 1/20000s On-Board Storage Micro SD slot, up to 256GB Alarm 1 input, 1 output Audio 1 input (RCA), 1 output (RCA) Hardware Reset Yes Smart Feature \\"Face Detection ,Human Detection, Perimeter Intrusion Detection(PID) , Cross Counting(CC),Stationary Object Detection(SOD), Heat Map(HM),Crowd Density Detection(CD) \\" Network Ethernet RJ45(10/100BASE-T) Video Compression Format H.265+/H.265/H.264 Resolution \\"Main stream@30fps 5MP(2880x1620),4MP(2560x1440) 3MP(2304x1296), 1080P (1920x1080) 720P(1280x720) Sub steam@30fps 720P(1280x720),VGA(640x480),QVGA(320x240) Third stream@30fps VGA(640x480), QVGA(320x240)\\" Video Quality Adjustment 256Kbps ~ 8/16Mbps Bitrate control method CBR/VBR Streaming Capability Triple-Stream(Main/Sub/Third) Protocol TCP/IP, HTTP, HTTPS, DHCP, RTP/RTSP, SMTP, NTP, UPnP, SNMP, SFTP Web browser \\"IE10/11 Safari V12.1 above Firefox V.52 above Google chrome V.57 above Edge V.79 above\\" Security IP address filter; complicated password; Authenticated username and password Streaming Method Unicast/Multicast Application Programming Interface ONVIF( Profile S/G/T/M) Environmental Operating Conditions -30~+60°C/less than ≤ 95% RH Ingress Protection IP67, IK10 Electrical Input Voltage / Current D12V/POE(IEEE802.3af) Power Consumption(IR OFF) 3W-4W Power Consumption(IR ON) 5W-7W Certification CE, FCC, RoHS, ISO 9001, BIS-ER, STQC etc. complete in all respect. |
| 2 | 5MP/6MP |
| 3 | Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having minimum specifications and features etc. or higher as mentioned belowFeatures Up to 32 channel input 4 SATA interfaces, up to 12TB (Enterprise-Class) Throughput: 320Mbps(incoming)/320Mbps(Outgoing) H.265+/H.265/H.264 Video Formats Connectable to the third party network cameras Supports live view, storage and playback of the connected camera at up to 12MP resolution 2×RJ45 self-adaptive 10/100/1000 Mbps network interfaces 2 HDMI Port, USB3.0*1, USB2.0*2 Support Supports intelligent analytics such as facial recognition, human detection, Vehicle detection, License plate recognition, perimeter intrusion, and line crossing statistics Alarm Input/out: 16in /1out Video Resolution 12 MP/8 MP/5 MP/4 MP/3 MP/1080p/720p Incoming Bandwidth 320M Outgoing Bandwidth 320M Performance Recording Resolution 12 MP/8 MP/5 MP/4 MP/3 MP/1080p/720p Recording Compression \\"Audio: G.711a,G.711u Video : H.264/H.265、H.264+/H.265+\\" Speed \\"12MP:30fps 8MP:120fps 4MP:240fps 2MP:480fps \\" Playback \\"1080P:480fps Max 16CH \\" Network WEB \\"IE10/11 Safari V12.1 above Firefox V.52 above Google chrome V.57 above Edge V.79 above\\" Protocols TCP/IP, DHCP, IPv4, IPv6, DNS, DDNS, NTP, RTSP, SADP, SMTP, SNMP, UPnP, HTTP, HTTPS API Onvif (profile S/G/T) Interface VGA 1(1024*768, 1280*720, 1280*1024, 1440*900, 1920*1080 ) HDMI 1(1024*768,1280*720,1280*1024,1440*900,1920*1080,2560*1440(2K),3840*2160(4K)) \\"1(1024*768, 1280*720, 1280*1024, 1440*900, 1920*1080 /EDID) Async out\\" Ethernet 2 RJ45 100/1000 Base-T USB \\"USB2.0*1(front) USB3.0*1+USB2.0*1(rear)\\" Audio 1 in / 1 out E-sata 1 HDD 4 ,each up to 12TB RS485 1 Alarm Input/out 16 in /1 out General Raid Raid0 & Raid1 OSD Language English Dimension (WxDxH) 378*326*66mm Weight 2300g Input Voltage/Current 12V/5A Power consumption (excluding hard disk) 8W Operating Temperature/Humidity \\"Temperature :-10°C~+50°C (14°F ~ 122°F) Humidity : Less than 90%RH\\" FCC YES CE YES etc as required at site. |
| 4 | 32 Channel Network Video Recorder (NVR) |
| 5 | Hard Disk DriveSupplying, Installation, Testing and Commissioning following capacity Surveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. |
| 6 | 8TB (Terabytes) |
| 7 | Supplying, installation, Testing and commissioning of following capacity 24 port Layer 3 Network Switch having features and specifications etc. as mentioned here under: At least 20 X RJ-45 Gigabit Ethernet Ports and additional 4 combo 10/100/1000 base-t/SFP Ports with additional 4 SFP+ ports non-blocking architecture by having Switching capacity of min. 128Gbps and packet forwarding rate of 95Mpps or higher, 16K MAC table. Console Port, USB port, Internal AC Power supply with operating temperature of 0 to +50 0C. Stacking port with stacking support of minimum 8 units per stack. 48K Mac address, 9K or more Jumbo frame, ERPS with enabling ring to converge in less than 50 ms from node or link failure, Static routing, Static, 6to4, ISATAP and GRE, IPv6 Neighbor Discovery (ND), BGP, ISIS, MPLS, VRRP v2, OSPFv2/v3, PBR, Route Redistribution, RIPv1/v2/ng, IP Helper all L3 Protocols should support from day 1 for both IPv6 and IPv4, 802.1x, Port security , Radius C TACACS+ authentication C accounting, DAD, DAI, DoS attack prevention, SSH, Guest VLAN, IP Access List, MAC Access List. Multicast: VLAN, PIM-SM, PIMDM, PIM- SDM, PIM-SMv6, DVMRP v3 and MSDP, IGMP C MLD Snooping, Flow mirroring, IGMP C MLD Snooping Ǫuerier, Per-VLAN IGMP C MLD Snooping. SNMP, Dual configurations, Multiple images, RMON, LLDP/LLDP-MED, sFlow, DHCP/BOOTP Client, IPv4/IPv6, Syslog server, Debug command, 802.3ah Ethernet Link OAM, 802.1ag Connectivity Fault, Y.1731 OAM, 802.1Ǫbb Priority- based Flow Control (PFC), Dying Gasp, Cable Diagnostics , 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required. |
| 8 | Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel. 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. |
| 9 | Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. |
| 10 | 9 U Rack |
| 11 | Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color, Use for 24- 26 AWG stranded wires etc. complete as required. |
| 12 | Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force: 11.5Kg etc. complete as required. |
| 13 | 1 Run of cable |
| 14 | Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. |
| 15 | Copper Patch Cords of length 1m (3ft) |
| 16 | Supplying and fixing Patch Cord of Optical Fiber Multi Mode or Single Mode LC to LC Fiber Duplex having high precision ceramic ferrule with good concentricity, Fiber corning single mode G652D, Cable Type 2mm with Mechanical specification Apex Offset < 50 µm, Fiber Height + 100 nm, End-face radius of Curvature 7mm < R < 0.2 db, Working ambient Temperature – 5 0C to +50 0C, Storage Temperature – 10 0C to +50 0C, Length -- 2meter, Type -- LC-LC Duplex etc complete as required. |
| 17 | LED DisplaySupplying, Installation, Testing and Commissioning of following size LED display (LED monitor) industrial grade with 3840x2160 resolution or better, USB playback, bluetooth and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits or better, Video wall mode should be available, contrast ratio: 1200:1, OPS slot, viewing angle (H/V): 170°/ 170°, response time less than 12ms, Display control shall be on monitor screen and programmable with remote (remote shall be supplied with system), Key Board, Optical Mouse, etc. as required. |
| 18 | 42 inch or large |
| 19 | Supplying, Installation, Testing and commissioning of small form-Pluggable (SFP) for Network Switches. Must be hot Pluggable, RoHS Complaint, etc. complete as required. |
| 20 | 1G SFP Single Mode/Multi Mode |
| 21 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 22 | 25 mm |
| 23 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 24 | 3 x 2.5 sq. mm |
| 25 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box includingconnections but excluding modular plate etc. as required. |
| 26 | 5/6 A switch |
| 27 | 3 pin 5/6 A socket outlet |
| 28 | Supplying and fixing following size/ modules, GI/PVC box along with modular base & cover plate for modular switches in recess etc. as required. |
| 29 | 6 Module (200mmX75mm) |
| 30 | SITC of HDMI cable 2.1 with Ethernet of following size having, 8k@60Hz, 4k@120Hz UHD Resolution, 48 GBPS Transmission Ultra High Speed, male to male, compatible with LED display as required at site upto the entire satisfaction of Engineer Incharge. |
| 31 | 5 mtr |
| 32 | 10 mtr |
| 33 | Online UPS - Input supply: Single Phase, Output Supply: Single Phase.Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion (ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 lagging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 0C, Relative humidity 0-95% non-condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA, Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/ RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accessories are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc. |
| 34 | 2 KVA |
| 35 | Installation testing and commissioning of existing 5MP IP Dome camera in complete respect as required at site. |
| 36 | Installation testing and commissioning of existing 16 channel Network Video Recorder (NVR) in complete respect as required at site. |
| 37 | Installation of existing 9U rack complete in all respect as required at site. Please Enable Macros to View BoQ information |