| 1 | ROOM-1 (6 ft × 10 ft × 10 ft ht = 1.829 m × 3.048 m × 3.048 m) |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering — All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)[Foundation bed / levelling course — 230 mm wide × 450 mm depth] |
| 4 | Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources).[At plinth level — 230 mm wide, over full width of wall] |
| 5 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in :Cement mortar 1:4 (1 cement : 4 coarse sand)[230 mm thick wall in foundation & plinth — height 0.45 m] |
| 6 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)[230 mm thick wall above plinth — net qty after 10% deduction for openings as per IS:1200] |
| 7 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).[RCC lintels / plinth band / roof band — 150 mm × 150 mm section] |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).[RCC roof slab — 125 mm thick] |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform [Soffit area of RCC roof slab] |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers[Soffit area of RCC lintels/bands = perimeter × width 0.15 m] |
| 11 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level :Thermo-Mechanically Treated bars of grade Fe-500D or more[Slab @ 80 kg/cum + lintels/bands @ 100 kg/cum — approx] |
| 12 | 12 mm cement plaster of mix :1:6 (1 cement : 6 coarse sand)[On internal faces of brick walls in superstructure — net area after 10% deduction for door/window openings as per IS:1200 Part-XII] |
| 13 | 15 mm cement plaster on rough side of single or half brick wall of mix :1:4 (1 cement : 4 coarse sand)[On external faces of brick walls in superstructure — net area after 10% deduction for door/window openings as per IS:1200 Part-XII] |
| 14 | 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand)[On soffit of RCC roof slab — ceiling plaster] |
| 15 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering — All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)[75 mm thick PCC base below floor finish] |
| 16 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete.Size of tile 600 × 600 mm |
| 17 | Providing and fixing flush door shutters (non-decorative type), solid core type conforming to IS:2202 (Part-I) with frame of 1st class hard/semi-hard wood, both faces covered with commercial plywood 4 mm thick bonded with phenol formaldehyde synthetic resin (BWP grade), including all hardware fittings viz. 3 pairs M.S. butt hinges bright finished, 1 no. mortice latch with lever handles, 1 no. tower bolt, rubber door stopper etc., all complete.[Size : 900 mm × 2100 mm — 1 No. per room] |
| 18 | Providing and fixing M.S. (mild steel) window frames of standard rolled steel sections as per IS:1038 with lugs fixed to masonry, including priming coat with red oxide zinc chromate primer conforming to IS:2074, with 4 mm thick plain sheet glass conforming to IS:2835 fixed with putty and glazing beads, including all hardware fittings viz. 1 no. central latch, 1 no. tower bolt, hold fasts etc., complete.[Size : 900 mm × 1200 mm — 2 Nos. per room] |
| 19 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content :With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre[One coat on all new plastered wall and ceiling surfaces before finish paint] |
| 20 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats[On all internal plastered wall and ceiling surfaces — new work] |
| 21 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)[On all external plastered wall surfaces — new work] |
| 22 | ROOM-2 (6 ft × 4 ft × 10 ft ht = 1.829 m × 1.219 m × 3.048 m) |
| 23 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 24 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering — All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)[Foundation bed / levelling course — 230 mm wide × 450 mm depth] |
| 25 | Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources).[At plinth level — 230 mm wide, over full width of wall] |
| 26 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in :Cement mortar 1:4 (1 cement : 4 coarse sand)[230 mm thick wall in foundation & plinth — height 0.45 m] |
| 27 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)[230 mm thick wall above plinth — net qty after 10% deduction for openings as per IS:1200] |
| 28 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).[RCC lintels / plinth band / roof band — 150 mm × 150 mm section] |
| 29 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).[RCC roof slab — 125 mm thick] |
| 30 | Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform [Soffit area of RCC roof slab] |
| 31 | Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers[Soffit area of RCC lintels/bands = perimeter × width 0.15 m] |
| 32 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level :Thermo-Mechanically Treated bars of grade Fe-500D or more[Slab @ 80 kg/cum + lintels/bands @ 100 kg/cum — approx] |
| 33 | 12 mm cement plaster of mix :1:6 (1 cement : 6 coarse sand)[On internal faces of brick walls in superstructure — net area after 10% deduction for door/window openings as per IS:1200 Part-XII] |
| 34 | 15 mm cement plaster on rough side of single or half brick wall of mix :1:4 (1 cement : 4 coarse sand)[On external faces of brick walls in superstructure — net area after 10% deduction for door/window openings as per IS:1200 Part-XII] |
| 35 | 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand)[On soffit of RCC roof slab — ceiling plaster] |
| 36 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering — All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)[75 mm thick PCC base below floor finish] |
| 37 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete.Size of tile 600 × 600 mm |
| 38 | Providing and fixing flush door shutters (non-decorative type), solid core type conforming to IS:2202 (Part-I) with frame of 1st class hard/semi-hard wood, both faces covered with commercial plywood 4 mm thick bonded with phenol formaldehyde synthetic resin (BWP grade), including all hardware fittings viz. 3 pairs M.S. butt hinges bright finished, 1 no. mortice latch with lever handles, 1 no. tower bolt, rubber door stopper etc., all complete.[Size : 900 mm × 2100 mm — 1 No. per room] |
| 39 | Providing and fixing M.S. (mild steel) window frames of standard rolled steel sections as per IS:1038 with lugs fixed to masonry, including priming coat with red oxide zinc chromate primer conforming to IS:2074, with 4 mm thick plain sheet glass conforming to IS:2835 fixed with putty and glazing beads, including all hardware fittings viz. 1 no. central latch, 1 no. tower bolt, hold fasts etc., complete.[Size : 900 mm × 1200 mm — 2 Nos. per room] |
| 40 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content :With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre[One coat on all new plastered wall and ceiling surfaces before finish paint] |
| 41 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats[On all internal plastered wall and ceiling surfaces — new work] |
| 42 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)[On all external plastered wall surfaces — new work] |
| 43 | Contigency for unseen work @ 3% |
| 44 | GST @ 18% Please Enable Macros to View BoQ information |