| 1 | Sch 'A' Part-I B/R Portion:-Demolition of brick work or stone/ boulder masonry built in cement mortar or cement lime mortar including all quions, wall, arches, pillars, man-holes, drain etc complete all as specified and directed. |
| 2 | M&L for burnt clay brick work with sub-class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 complete all as specified and directed. |
| 3 | Taking down cement plaster of any description and thickness on walls/ceilings etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 4 | M&L for rendering 15mm thick in CM 1:4 mixed with liquid water proofing compound on fair faces of brick work ,concrete surface of wall, fin, facia, chajjas, parapet and similar article finished surface even and smooth without using extra cement complete all as specified and directed. |
| 5 | M&L for rendering 10mm thick in CM 1:6 mixed with liquid water proofing compound on other than fair faces of brick work ,concrete surface of wall, fin, facia, chajjas, parapet and similar article finished surface even and smooth without using extra cement complete all as specified and directed. |
| 6 | M&L for 5 mm thick rendering on brick work or concrete surfaces in CM 1:3 as in ceiling of roof slab ,fin, facia, culvert, chajjas, parapet and similar article etc finishing surfaces even and smooth without using extra cement complete all as specified and directed. |
| 7 | M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. |
| 8 | M&L for preparation of Old plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. |
| 9 | M&L for preparation of newly plastered surfaces of wall and applying two coats of Cement Base Paint over and including one coat of alkali resistant priming paint complete all as specified and directed. |
| 10 | M&L for preparation of new plastered surfaces and alkali resistance priming paint for priming to distempering and applying two coats of distemper oil emulssion, white or tinted, inculdind applying minimum 1.5 mm thick white cement based wall care putty on wall surfaces & making smooth surface complete all as specified. |
| 11 | M&L for complete removal of existing treatment surface of wall and applying two coats of Cement Base Paint without any brush marks on the surface in any colour & matching with existing work over and including a coat of alkali resistant primer (as per manufacturer’s recommendations) including necessary scaffolding any height if required at site including cleaning of drops, splashes and leaving premise clean and tidy complete all as specified and as directed. |
| 12 | M&L for complete removal of existing treatment of old plastered or unplastered or old decorated wall surface (internal) by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying two coat of distemper oil emulsion in any tint on wall surface (internal surface) without any brush marks & matching with existing work including necessary scaffolding up to four storeys bldgs height if required at site including cleaning of drops, splashes and leaving premise clean and tidy complete all as specified and as directed. |
| 13 | M&L for 10mm thick cement plaster in cement mortar 1:3 concrete surface finished even and smooth as on roof mixed with with WPC as per manufacturer's instruction complete all as specified & directed.(WPC measured & paid separetaly) |
| 14 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for , rubbish off the premises complete all as specified and directed |
| 15 | M&L for PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) padding as roof , surface finished even and smooth without using extra cement complete all as specified and directed. |
| 16 | Supply only liquid water proofing compound |
| 17 | M&L for cleaning and preparation of existing Non acceessible/accessible roof surface of any description upto ht of double storey bldg properly by washing and drying, removing all loose material, dirt and foreign particles incl fungus /algae/overgrowth of plants if any completely.identify the cracks over terrace and around the rain water spouts and the same should be grouted with 1:3 CM and make the terrace completly smooth as per slop.The application shall include base preparation with application of primer coat and then apply first coat of cold liquid Membrane STP Tarfelt LM or equivalent make having elongation not less then 200% conforming to ASTM-C-412 & having crack bridging ability of 3.00 to 4.00 mm confirming to ASTM-C-836 with tensile strength ranges to 8 -12 N/sqmm and confirming to ASTM-C-412 with no diluation of water.. Apply 2nd coat similar to first coat after 12 Hrs in opposite direction of first coat by Brush or Roller.. Applying two coats of U V Resistant Elastomeric Exterior Axcrylic Weather resistant water proof coating of Shalicryl-215 or equivalent approved make. Note:- Application of water proofing treatment will be done by Authorised Applicator only. |
| 18 | Demolition of cement concrete or lime concrete (unreinforced) in ground floors and Paving not exc 15 cm thick (below or above ground level ) and removing the debris outside from defence land complete all as specified and directed . |
| 19 | M&L for 75mm thick plain Cement concrete 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) as in plinth protection, apron, path and paving finished even and fair complete all as specified and directed. |
| 20 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed. |
| 21 | M&L for 25 mm thick cement concrete 1:2:4 type B-0 using 12.5 mm graded crushed stone aggregate as in sub base all as specified and directed. |
| 22 | M&L for joint free Non - skid Ceramic Coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including Dismantling of tile, 15mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 23 | All as per srl item No 22.00 above but as in vertical/skirting surface etc over and including 10mm thick rough cement plaster to receive tiles in CM 1:4 complete all as specified and directed. |
| 24 | M&L for Glazed ceramic tiles in vertical/dado surface 450mmx300mmx7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over & including Dismantling of tile ,10mm thick rough cement plaster to receive tiles in CM 1:4 complete all as specified and directed. |
| 25 | M&L for machine cut kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete over screed bed or bedding layer 20 mm thick in cement mortar 1:4, complete all as specified and as directed.Note :- Rate included for all cutting ,waste including machine cutting to make it square or rectangular,cutting and polishing by machine & size of kota stone shall not be less than 550 mmx550mm . |
| 26 | M&L for machine cut kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar laid over backing coat 10mm thick in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and as directed.Note :- Rate included for all cutting ,waste including machine cutting to make it square or rectangular,cutting and polishing by machine & size of kota stone shall not be less than 550 mmx550mm . |
| 27 | Demolition of RCC of any description slab , shelves , chajjas, water tank ,chullah hoods etc and in any position including cutting reinforced as required complete all as specified and directed. |
| 28 | M&L for RCC, M-20 using 20 mm graded aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 29 | M&L for form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick horizontal or sloping for rough finished surfaces of concrete complete all as specified and directed. |
| 30 | M&L for Mild steel TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and directed. |
| 31 | M&L for preparation of newly steel and iron surface of any description width or girth exc 10 cm and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed complete all as specified and directed. |
| 32 | Taking down chowkhats or frames exc 1.50 and n.exc 4 Sqm each (without talking off shutters from the frame) complete all as specified and directed. |
| 33 | Taking down chowkat or frames with shutters (without taking off shutters from the frames) area not exc1.5 Sqm each and removing from site complete all as specified and directed. |
| 34 | S&F pressed steel frames 105 x 60 x1.25 mm with one or more rebates including necessary fixing lugs/hold fast duly tarred with bitumen and sanding with sharp clean sand, hinges, lock strike plate including one shop coat of primer complete all as spd and directed |
| 35 | S&F factory made Pressed steel frame of size 125x60x1.25mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete and back filling of hollow portion of frame including fixing of hold fast with plain cement concrete type B-0, 1:2:4 using 12.5 mm graded crushed stone aggregate complete all as spd and directed |
| 36 | S&F factory made 35mm thick of 2nd class hard wood Glazed and skeleton door shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain ,chamfered or rounded. fitted with cut and mitered beads for securing glass ,etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats, kiln seasoned, chemically pressure treated complete all as specified and directed. |
| 37 | S&F Factory made 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 38 | S&F Steel window/ventilator factory made, made out of mild steel box type and shutter suitable for double shutter i.e. Glazed and gauged shutter. Glazed shutter made out of hollow' section with sash bar and gauged shutter made out of hollow section without sash bar including hinges, tower bolt, handle, grill 10 mm sq bar including two coat of synthetic enamel paint over one coat of red oxide primer, tarred hold fasts, PCC bed blocks for fixing hold fast, including plain/figured glass 3mm thick and stainless steel wire cloth 0.36mm nominal dia of wire & average width of aperture 1.18mm & fixed with stainless steel wire staples`etc complete all as per details shown in drawing No CEPZ/C-TD/032/13 sheet No 1/2 & 2/2 including taking down existing spoiled and unserviceable windows/ventilators of any type ( wooden/steel) complete all as specified and directed |
| 39 | S&F 250mm long Aluminum alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminum alloy and fixed complete all as specified and directed. |
| 40 | S&F 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate complete including welding to steel frames as required at site complete all as specified and directed. |
| 41 | S&F 200mm long aluminum, anodised, barrel tower bolts of extruded section and fixed, complete all as specified and directed. |
| 42 | S&F 140mm long Floor door stopper of aluminum alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified . |
| 43 | S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples or using metal nut and bolts complete all as specified . |
| 44 | Taking up or down 15mm bore, steel tubing and connection including cleaning for refixing or removal from site complete all as specified and directed. |
| 45 | All as per srl item No 44.00 above but 20mm bore Steel water tubing complete all as specified and directed. |
| 46 | S&F 15mm bore Steel water tubing 'medium grade', galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 47 | All as per srl item No 46.00 above but 20mm bore Steel water tubing |
| 48 | Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, shelves, lintels, etc, and cutting chases for concealed water tubing or conduit wiring, etc and making good, cutting not exceeding 10cm girth complete all as specified and directed. |
| 49 | Taking down eaves gutter and rain water pipe any size any pattern ,PVC/ AC pipe including all fittings ,Internal dia of pipe in 75/110mm complete all as specified . |
| 50 | S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 51 | S&F PVC (SWR) pipes 75 mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 52 | S&F PVC (SWR) bends ISI marked any radius 75mm dia complete all as spd and directed. |
| 53 | S&F PVC (SWR) bends ISI marked any radius 110mm dia complete all as spd and directed. |
| 54 | S&F Rotational moulded polyethylene water storage tanks of 1000 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including dismantling of old PVC/RCC water tanks complete all as specified and directed. |
| 55 | S&F in repair for 600mmx1500mm beveled edge mirror of selected quality glass not less than 5.5 mm thick with edges rounded or beveled , mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 56 | S&F in repair 25mm outer dia stainless steel bright finished ,fancy type decorative drapery rod (Curtain Rod) of thickness 20 gauge with ends caps in (pair) fixed to wall with screws ,PVC gully including all necessary fixing arrangements, brackets etc complete all as specified and directed. |
| 57 | S&F in repair 15mm bore dia fancy type, chromium plated angular valves /stop valves, cast copper alloy, screwed down, high pressure ,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed (minimum weight 575 grams) complete all as specified and directed. |
| 58 | S&F in repair for 15 mm bore chromium plated fancy type Bib taps, cast copper alloy with crutch or above butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed (minimum weight 575 grams) complete all as specified and directed. |
| 59 | S&F in repair for gun-metal, globe or gate valves 20mm bore, with iron wheel head, screwed both end for iron pipe complete all as specified and as directed. |
| 60 | M&L for preparation of newly wooden Surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 61 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof covering, all as specified. |
| 62 | S&F pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping all as specified and directed. |
| 63 | S&F pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified. |
| 64 | Dismantling of timber scantlings 40 sq cm and over in sec in any position in unframed work. |
| 65 | M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. |
| 66 | Dismantling boarding, any description, fixed in any position with nails all as specified and directed. |
| 67 | S&F false ceiling with fibre cement designer tiles ivory painted (high pressure steam cured) of 4mm thickness (as per IS:14862) of size 595 x 595 mm and any one of the design (occeanic, lake & hill, cascade or electra) in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms, both side inclusive) consisting of main 'T' runnerwith suitably spaceed joints to get required length, and 15x32 mm made of 0.30 mm sheet, and cross 'T' at 600 mm c/c to form a grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main 'T' runners to be suspended from ceiling using GI soffit cleats fixed to exising rafter, purlin, etc with galvanised butterfly level clips, spaced at 1200 mm c/c along main T, bottom exposed width of 15 mm of all T-sections shall be centra black pre-painted with polyester paint, and havng a load bearing capacity of 12Kg/sqm, and refixed all existing electric wiring and fixture all complete at all heights as per direction of Engineer-in-Charge |
| 68 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as specified and directed. |
| 69 | M&L for 100mm thick Cement concrete type B-1, 1:2:4 (20mm graded crushed stone aggregate) in sub base all as specified and directed. |
| 70 | M&L for 50mm thick Sand filling under floors or in foundations including watering and consolidation all as specified and directed. |
| 71 | M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with Gray cement and Pigment and 100mm thick sand Cushion all as specified and directed. |
| 72 | M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors over 25 mm thick PCC as in sub base, Screed bed or bedding layer of mortar 15 mm thick CM 1:4 for laying floor finishes complete all as specified and directed. |
| 73 | M&L for Providing precast cement concrete type B0 1:2:4 (12.5mm graded aggragate) louvres and jallies, 25mm thick (measured solid) set in Cement mortar 1:4, including all mould- ings, frame work and also Including demolition of Old UNSV RCC jali of any size and shape all as specified and directed. |
| 74 | Sch 'A' Part-I E/M Portion:-Taking down old unserviceable copper/aluminium point wiring (light, fan, socket , power socket and bulk head fittings) on surface wiring on wooden batten/casings & caping complete, including fixture and fittings such as switches, ceiling roses,pendents holder, regulators and sockets by unscrewing carefully from boards etc and making good disturbed surfaces of walls, as per existing finishes complete all as spd and directed. |
| 75 | M&L for point wiring for one light/one fan controlled by one switch with 1.5 Sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H 1100 volte grade cable, with and including PVC rigid concealed conduit (ISI marked) with all fittings including sheet steel/CI terminal box of adequate size including 1.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable as earth continuity conductor connected to comman earth dolly, complete all as specified and directed.Note:- 1. connection of cable with MCBs/switch sockets shall be done through proper size copper /brass thimbles.2. Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit is not feasible. 3. Proper colour coud will be used for wiring as per the electrical rule and as directed. |
| 76 | All as per Srl item No 75 here-in-before but for 5 pin 5 amps socket outlet on the independent board controlled by one switch SP, one way 5 Amp, 240 Volts. complete all as specified and directed. |
| 77 | All as per Srl item No 75 here-in-before but for 5 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed. |
| 78 | M&L for point wiring with 2.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable with in and including PVC concealed conduit heavy duty with all fittings including anodise pressed steel sunken box with bakelite laminated sheet ISI marked suitable for 5 pin 15 amps socket outlet ,including 2.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable as earth continuity conductor connected to comman earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface finishing the surface to match with the existingsurface complete all as specified and directed. |
| 79 | M&L for point wiring with 4 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable with in and including PVC concealed conduit heavy duty with all fittings including anodise pressed steel sunken box with bakelite laminated sheet ISI marked suitable for 5 pin 15 amps socket outlet ,including 4 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable as earth continuity conductor connected to comman earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface finishing the surface to match with the existingsurface complete all as specified and directed. |
| 80 | S&F switch piano flush type one way 5 amps SP 240 volts complete all as specified and directed. |
| 81 | S&F switch piano flush type one way 15 amps SP 240 volts complete all as specified and directed. |
| 82 | S&F socket outlet 2 in 1, 3 pin 5 amps flush type 240 volts complete all as specified and directed. |
| 83 | S&F socket outlet 2 in 1, 3 pin, 5 and 15 amps flush type 230 volts complete all as specified and directed. |
| 84 | S&F lamp holder/batton holder/angle holder insulated body with bakelite back plate suitable for fittings complete all as specified and directed. |
| 85 | S&F ceiling rose 65 x 50mm three terminals complete all as specified and directed. |
| 86 | S&F ceiling fan regulator electronic socket type 5 stage speed variation ISI marked complete all as specified and directed. |
| 87 | S&F in replacement sleek LED mirror light fitting 2 feet long 1x10 W including inbuilt ind driver complete with all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of suitable size complete all as required at site or directed. |
| 88 | S&F energy saving surface mounted LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. |
| 89 | S&F LED bulb, B22 type ,14 watt, white complete all as specified and directed. |
| 90 | S&F sleek LED Batten light fitting, 1x20 W including LED tube 4 feet long of same make having ballast , bipin holder, connector block etc. complete with all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of suitable size complete all as required at site or directed. |
| 91 | Taking down carefully ceiling fan from the hook including dismantling the blades and minor repair such as replacement of locking pin, reel insulators, bolts, nuts etc and painting one coat of synthetic enamel paint of existing colour including rehanging the same at existing position after cleaning, greasing and connecting up with PVC insulated copper flexible wire of suitable size from ceiling rose to connector of fan complete all as specified and directed by Engr-in-Charge . |
| 92 | M&L for providing/ cutting the round/ square hole of required size in wall finishing the distrubed surfaces as per existing finishes complete all as spd and S&F PVC type AC ventilating fans Single phase, 230 volts 450 mm Fan (1400 RPM) complete and supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated copper cable suitable size from ceiling rose to exhaust fan motor and writting MES No. with black synthetic enamel paint 2.0 cm high complete all as spd and directed by Engr-in-charge. |
| 93 | Supply, fixing & testing ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and connecting with flexible copper conductor of suitable size, 3 core and including writing of MES No with black paint complete all as specified and as directed. |
| 94 | S&F in repair sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases in wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed. |
| 95 | S&F in repair MCB SP 240 volts any rating from 6 to 40 amps, 'B' cruve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed. |
| 96 | S&F in repair MCB SPN 240 volts any rating from 6 to 40 amps, 'B' cruve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed. |
| 97 | Supply and installation of the electric water storage heater of ABS body type, 25 ltr capacity with rated power 2KW, 5 star rated, vertical type, thermally insulated mild steel tank with glass line coating inside the tank alongwith glass lined incoloy heating element with anti corrosive magnesium anode, NRV, thermostat, indicators and temperature adjustable knob including steel braided flexible connection for pipe of size 15mm bore with GI hexagonal adopters/nuts on both sides for inlet (cold water supply) & outlet (hot water supply) and including provision of wall mounting arrangements and mounting on wall with suitable size of anchor bolts with complete connection of water including testing after installation complete all as specified and as directed. |
| 98 | S&F in replacement sub Main Wiring with two PVC insulated unsheathed multistrand FRLS-H flexible copper conductor cable of size 2x6 sqmm and one PVC insulated multistrand unsheathed FRLS flexible copper conductor cable of size 6 sqmm (green colour) as earthing lead connecting to main earthing dolly drawn in and including non metallic PVC concealed conduit 20mm dia complete and making good to disturbed surface complete of wall/floor with cement mortar and finishes to match the existing surface complete all as specified and directed. |
| 99 | S&F in replacement of existing unsv sheet metal enclosure with sheet metal enclosure MCB distribution board single pole and neutral with a two pin and earth plug and socket 20 amps 240 volts, complete with one single pole MCB of 20 amps 'C' curve complete all as specified and directed . |
| 100 | S&F in repair bldg secuirty light fitting energy saving high efficiency LED street light fitting 35 Watts, 5700 K, IP 66, having pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, prismatic polycarbonate cover complete including GI bracket of size 25 mm dia bent to shape having length not less than 0.9 mtr fixing with clamp etc and making connections using suitable size copper cable from ceilling rose/ PVC connector to light fittings or as directed by Engr-in-chrage. |
| 101 | S&F in replacement of old unsv sheet metal enclosures distribution boards, double door three phase 415 volts 4 ways vertical TPN DB for comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed and comprising of the following (a) MCCB FOUR POLE 63 AMPS AC 415 VOLTS 16 KA=01 NO as incoming . ( (i) MCCB and DB should be of same make. (ii) The DB shall be flush fixed ,and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost.(iii)connection of theMCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble -properly crimped.(iv) all the vacant holes of the DB shall be provided with blank plates of appropriate size. (v) double continuous earth wire shall be provided for each three phase DB from earthing mains dolly. |
| 102 | M&L for earthing complete with galvanised steel earth plate electrode , 600 x600 x 6mm thick burried directly in the ground (earth pit not less than 2.25 mtr deep below ground level)with top edge of the plate not less than 1.5mtr below ground level connected to galvanised iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point , GI tubing 15 mm bore light grade protection pipe , GI watering pipe 20mm bore light grade with funnel and wire mesh , charcoal ,salt packed around the earth plate and precast PCC 1:2:4 (Nominal mix ) reinforced with XPM having weight not less than 4 kg /sqm including suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover including earth work in any type of soil , removal of surplus soil to a distance n.exc 50m and connecting , testing on completion complete all as shown on electric plate No 05 of SSR -2009 Part I and connecting to existing earth test point complete all as specified and directed or including testing on completion.(Note: Excavation and earth work is deemed to be included in the rates quoted). |
| 103 | Supply, laying and testing in replacement LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 25 sq. mm 3.5 core complete all as specified |
| 104 | Supply, laying and testing in replacement LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 16 sq. mm 2 core complete all as specified |
| 105 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil for laying of cable ,pole foundation,stay,laying of pipe etc complete all as specified and directed. |
| 106 | Returning filling in, including spreading ,leveling ,watering and well ramming in layers not exc 25 cm complete all as specified. |
| 107 | Removing excavated soil to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 108 | M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified (Note:-Punned thickness shall be measured and paid) |
| 109 | M&L for brick covering equal to length of bricks as mechanical protection to cable with well burnet sub class ‘B’ bricks laid as directed by the Engr-in-Charge. |
| 110 | S&F GI tubing light grade 50 mm bore for cable protection laid in trenches in road crossing or fixed to wall/Pole including fittings /clamp complete all as specified and directed. |
| 111 | Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 70,663.00 and any other reduction if any from quoted amount. Please Enable Macros to View BoQ information |