| 1 | Dismantling plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof covering complete all as specified and as directed. . |
| 2 | S & F for Pre- painted galvanlume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 3 | S & F for Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 4 | Dismantling timber scantling 40 Sqcm and over in section in any position in unframed work complete all as specified and as directed. |
| 5 | M & L second class soft wood in scantling clean swan complete all as specified and as directed. |
| 6 | Dismantling wall and ceiling board (fibre, pulp, insulation, etc.) or insulation board /slab/blankets, any thickness, including cover fillets complete all as specified and directed. |
| 7 | M & L Plain fillets of exc. 3 & n exc. 6 Sqcm, square rectangular or triangular in section, clean swan, secured nails complete all as specified and as directed. |
| 8 | M&L plywood grade BWR type BB, 12 mm thick fixed with nails to timber frame work in ceiling complete all as specified and as directed. |
| 9 | M&L plywood grade BWR type BB, 6 mm thick fixed with nails to timber frame work in wall complete all as specified and as directed. |
| 10 | M&L for Preparation of newly un treated surfaces and applying two coat of synthetic enamel paint over a coat of pink primer on wooden surfaces of any description not other wise described over 10 cm width or grith etc complete all as specified and as directed. |
| 11 | Dismantling of boarding of any description fitted in any position with nails complete all as specified and as directed. |
| 12 | S&F 20mm thick 2nd class softwood boarding, planed one side, with butt joints and fixed with nails in facia eaves boarding complete all as specified and as directed. |
| 13 | M&L 2nd class softwood weather boarding clean sawn, plain 20mm thick or feather edged 15mm to 20mm thick and fixed with 30mm laps complete all as specified and as directed. |
| 14 | Taking down chowkat with shutters exc.1.5 Sqm but n exc.4 Sqm (w/o taking off shutters from chowkhat) complete all as specified and as directed. |
| 15 | Taking down chowkat with shutters n. exc.1.5Sqm (w/o taking off shutters from chowkhat) complete all as specified and as directed. |
| 16 | S & F 2nd class soft wood plain solid straight chowkats and frames wrought framed, rebated on the solid complete all as specified and as directed. |
| 17 | S &F for Plain, framed, panelled shutters second class soft wood 35 mm thick (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and as directed. |
| 18 | S & F Glazed and skeleton shutters, second class soft wood 30 mm thick open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and as directed. |
| 19 | Hacking out old broken glass (any thickness, size quality of description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed. |
| 20 | S&F 03 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq.m in each pane complete all as specified and as directed. |
| 21 | S&F 100 mm long butt hinges extruded aluminium anodised complete all as specified and as directed. |
| 22 | S&F 75 mm size mild steel butt hinges medium weight complete all as specified and as directed. |
| 23 | S&F 150mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and as directed. |
| 24 | S&F 100 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and as directed. |
| 25 | S&F aluminium anodised alloy handles fabricated type 150mm size of handle complete all as specified and as directed. |
| 26 | S&F 100 mm long aluminium handles cast type anodised complete all as specified and as directed. |
| 27 | S&F 300mm long aluminium alloy, anodised sliding door bolt, with hasp and staple (bolt type) cast or extruded section and fixing bolts of extruded section complete all as specified and as directed. |
| 28 | Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 29 | M & L for Cement concrete D-2 1:4:8 Type 20 mm graded aggregate, 75 mm thick as in sub base over rammed earth complete all as specified and as directed. |
| 30 | M & L for Cement concrete B-1, 1:2:4 Type 20 mm graded aggregate, 25 mm thick as in sub base over rammed earth complete all as specified and as directed. |
| 31 | M&L for Vitrified Ceramic tiles light shade approved quality10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors and skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement including 15 thick screed mortar in CM 1:6 all as specified and directed |
| 32 | M&L Chequered cement concrete tiles (200x200x25mm) thick with grey cement and no pigment, set jointed & pointed in neat cement slurry in floors over 15 mm thick screed bed of 1:4 cement mortar complete all as specified and as directed. |
| 33 | Demolition of Brick/stone masonary, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stonework and precast concrete articles complete all as specified and directed. |
| 34 | M&L for walling of random rubble, uncoursed, well bonded, beaded and solidly hearted in CM 1:4 complete all as specified and directed. |
| 35 | M&L for rendering 15mm thick on fair faces of stone masonry surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed. |
| 36 | M & L for Plain cement concrete 1:2:4 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 37 | M&L for 50mm thick Granolithic cement concrete (1:1:2) floor topping treated with three dressing of sodium silicate finished fair surface complete all as specified and as directed. |
| 38 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed. |
| 39 | M&L for Polythene film, black, 50micron laid in floors complete all as specified and as directed. |
| 40 | M & L for 10 mm thick rendering in Cement Mortar 1:4 on any faces of brick or concrete surfaces of walls & finishing the surface even and smooth without using extra cement including taking down cement or cement lime plaster on brick or stone walls, complete all as specified and directed. |
| 41 | M&L for preparation of old plastered surfaces of wall and applying two coats of Flame Proof Fire Resistant Magazine Paint on Cement Plaster Concrete Surface complete all as specified and as directed. |
| 42 | M&L for preparation old/New surface Finishing walls with Acrylic Smooth exterior paint of required shade: New work/old work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and as directed. |
| 43 | M&L for chipping out existing substrate internal / External wall surfaces including (RCC beam, Slab & Columns etc) of existing cleaning / washing the surface with water thoroughly then apply diluted cement modified grout (diluted latex 1:6) on roughened and Cleaned Surfaces to Sealing the porosity/and minor Cracks in existing surfaces including (RCC wall, beam, Slabs etc) at any height complete all as specified and as directed. (Note:-(i) Application and Consumption of ''Diluted Latex'' shall be as per Manufacturer's instruction). (ii) Work shall be carried Out only through authorised applicators of approved manufacturers and guarantee for no leakage and Seepage in that treated surfaces shall be submitted for ten years by the contractor and 5% amount of work done of water proofing compound shall be retained in FB/RAR ) |
| 44 | M&L for cement concrete (1:2:4) M-30 type B-1 using 20 mm graded crushed stone aggregate as in surface channels and drains and benching including finishing the top of benching even and smooth using extra cement complete all as specified and as directed. |
| 45 | S&F For Aluminium dividing strips, 1.5mm thick & 50 mm Wide complete all as specified and as directed. |
| 46 | M&L for earth work in excavation all Kind of soil by mechanical means (Hydraulic excavator) means over areas of excavated earth lead upto 50 m and lift upto 4.5m, as directed (exceeding 30 cm in depth, 4.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m complete all as specified and as directed. |
| 47 | M&L for forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick, watering ramming/ rolling and finishing to required size, shape etc n exc 4.5m high from base complete all as specified and as directed. |
| 48 | M&L for brick work with sub class 'B' brick straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and as directed. |
| 49 | M & L for two coat of flame Proof Fire Resistant Magazine Paint on Steel Surfaces old surfaces of any description over 10 cm in width or girth complete all as specified and as directed. |
| 50 | Surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting out in any type of soil |
| 51 | Excavation in trenches n. exc 1.5m in depth and 1.5m in width and getting out in hard' dense soil complete all as specified and directed. |
| 52 | M & L for RCC pipes laid in trenches and jointed complete with collars of bore 200mm NP2 pipes complete all as specified and directed. |
| 53 | M & L for concrete bed 1:4:8 type D2 using 40mm graded stone aggregate to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for bore 200mm pipes complete all as specified and directed. |
| 54 | S&F 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors / fixed to walls complete all as specified and directed. |
| 55 | S&F PVC (SWR) bends any radius, 110mm bore, fitted with oval access door complete all as specified and directed. |
| 56 | S&F 110mm bore PVC (SWR) junction, single (single T) equal or unequal with door access complete all as specified and directed. |
| 57 | M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and as directed. |
| 58 | M & L for PCC 1:3:6 C-1 using 20mm graded stone aggregate as in coping including necessary formwork complete all as specified and directed. |
| 59 | M & L for rendering 15mm in two layers thick in CM 1:4 on block wall concrete surfaces finished even and smooth without using extra cement with mixing of water proofing compound as per manufacturers instructions complete all as specified and directed. |
| 60 | Supply only integral water proofing compound |
| 61 | M&L for PCC 1:2:4, type B-1, using 20mm graded aggregate as in precast cover slabs complete all as specified and directed. |
| 62 | M & L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 63 | M & L for cement concrete 1:3:6 C2 using 40mm graded stone aggregate as in surface channels and drains complete all as specified and directed. |
| 64 | M&L for PVC (SWR) vent cowl 75mm dia complete all as specified and directed. |
| 65 | M&L for construction of 30 users septic tank complete all as specified and shown on drawing No. CESZ-TD-/2015 sheet No 1/3 & 2/3 dated 22 Feb 2015 (Revised dt 21 Mar 2015) and specified in particular specifications. |
| 66 | M&L for construction of Soakage well, of size 3.00 m dia at bottom and 3 m effective depth complete all as specified and shown on drawing No. CESZ-TD-/2015 sheet No 1/3 & 3/3 dated 22 Feb 2015 (Revised dt 21 Mar 2015) and specified in particular specifications. |
| 67 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in hard/dense soil complete all as specified and directed. |
| 68 | M&L for point wiring in replacement for one light point/fan point controlled by one switch with 1.5 sqmm PVC FRLSH insulated un-sheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC FRLSH insulated un-sheathed copper conductor single core multi stranded flexible cable (green colour) as earth lead in and including cable 1100 volts grade including casing and capping/conduit (ISI marked) including sunk cast iron/pressed steel terminal boxes, junction boxes, other boxes made from thick sheet of suitable sizes for mounting of switches, sockets, fan regulators, light fittings etc. covered with plastic laminated sheet or PVC gang box 2 to 8 way as per site requirement fitted in surface mount or concealed including cutting chases to wall making good the disturbed surfaces to match with the existing specification including taking down old one, complete all as specified and directed. |
| 69 | All as per item No 68 herein before but wiring with 1.5 sqmm copper wire (FR-LS-H) and 1.5 sqmm earth wire for socket outlet 3 pin 5 amps on same board, with taking down complete all as specified and directed. |
| 70 | All as per item No 68 herein before but wiring with 1.5 sqmm copper wire (FR-LS-H) and 1.5 sqmm earth wire for socket outlet 3 pin 5 amps on independent board with taking down complete all as specified and directed |
| 71 | All as per item No 68 herein before but wiring with 2.5 sqmm copper wire (FR-LS-H) and 2.5 sqmm earth wire for socket outlet 6 pin 15 amps on independent board with taking down complete all as specified and directed. |
| 72 | S&F of switch piano flush button single pole, one way 5 amps complete all as specified and directed. |
| 73 | S & F switch socket combination 2 in 1,5A, flush type complete all as specified and directed. |
| 74 | S & F switch socket combination 5 pin 16A, flush type complete all as specified and directed. |
| 75 | S&F of distribution board single pole & neutral with 200 Amps rated bus bar for single door IP-42 DB's, made out of sheet steel enclosure, recessed type, factory made powder coated 4 way -240 volts suitable for housing MCB's and isolator's complete in all fixing material/accessories etc complete all as specified and directed. |
| 76 | S&F of distribution board single pole & neutral with 200 Amps rated bus bar for single door IP-42 DB's, made out of sheet steel enclosure, recessed type, factory made powder coated 8 way -240 volts suitable for housing MCB's and isolator's complete in all fixing material/accessories etc complete all as specified and directed. |
| 77 | S&F MCB's single pole 240 volts 6 to 32Amps 10 KA 'C' curve series complete all as specified and directed. |
| 78 | S & F of MCB SPN, 240 volt, 63 Amp capacity, 10 KA, 'C' curve complete all as specified and directed. |
| 79 | M & L Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings complete all as specified and directed. |
| 80 | Supply and fix LED Bulb 9 Watt complete all as specified and directed. |
| 81 | Supply and fixing with replacement of LED lights fitting 1x 16W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, with taking down old one complete all as specified and directed. |
| 82 | Supply and fix ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body complete all as specified and directed. |
| 83 | S&F 09W/10W Bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 84 | M&L for earthing complete with galvanised steel earth plate electrode 60x60cmx6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge lead of the plate not less than 1.5 mtr below normal ground level, connected galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed. |
| 85 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sqmm nominal cross section in service connections with taking down complete all as specified and directed. |
| 86 | S&F Voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 100 KVA complete all as specified and directed. |
| 87 | Earthing complete with galvanised steel earth plate electrode (600x600x6)mm thick buried vertically in ground 3 meter below normal ground level with top edge of the plate, not less than 2.25 metre below normal ground level connected to GI strip of size 32x6mm by means of bolts, nuts and washers protected by GI tubing light grade 40 mm dia upto Test point 20 mm dia watering pipe with funnel & wire mesh, PCC pit in PCC 1:2:4 using 20 mm graded stone aggregate chamber 40 mm thick RCC cover slab (1:2:4) type B-1 using 20 mm graded stone aggregates complete all as specified and shown in electrical plate No 3 of SSR Part-I including earth work in any type of soil, removal of surplus soil and providing charcoal dust & salt layers all around the earth plate upto 15 cm complete all as specified and directed. (note: Upto 7.5 Mtr length of pipe of 40 mm dia and GI strip shall be deemed to be included in unit rate quoted by tenderer GI pipe and GI strip beyond 7.5 mtr or test point will be measured separately under respective item. |
| 88 | Supply, Laying , jointing and testing LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes and aluminium lugs for connection complete all as specified and directed of 70 Sqmm 4 core complete all as specified and directed. Please Enable Macros to View BoQ information |