| 1 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated copper conductor cable (FR) in pvc conduit (medium gauge) recessesd in slab/wall complete with 6/10 amps modular type switch, cover plate, GI box including necessary connection etc as required. |
| 2 | Wiring for 2 way controlling light point with 3 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc conduit (medium gauge) recessesd in slab/wall complete with 6/10 amps modular type 2 way switch, cover plate, GI box including connection etc as required:- |
| 3 | Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on modular concealed switch board with cover plate, earthing the 3rd pin etc. as required:- |
| 4 | Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on modular concealed switch board with cover plate, earthing the 3rd pin etc. as required:- |
| 5 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in pvc conduit (medium gauge) recessesd in slab/wall etc. as required. |
| 6 | 2 X 1.5 + 1 x 1.5 sq mm:- |
| 7 | 2 X 2.5 + 1 x 1.5 sq mm:- |
| 8 | 2 X 4 + 1 x 1.5 sq mm:- |
| 9 | 4 X 4 + 2 x 1.5 sq mm:- |
| 10 | 4 X 6 + 2 x 2.5 sq mm:- |
| 11 | 4 X 10 + 2 x 4 sq mm:- |
| 12 | 4 X 16 + 2 x 6 sq mm:- |
| 13 | 4 X 25 + 2 x 10 sq mm:- |
| 14 | 4 X 35 + 2 x 10 sq mm:- |
| 15 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated copper conductor cable (FR) in existing pvc conduit (medium gauge) recessesd in slab/wall complete with 6/10 amps modular type switch, cover plate, GI box including necessary connection etc as required. |
| 16 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- |
| 17 | 1 X 1.5 sq mm:- |
| 18 | 1 X 2.5 sq mm:- |
| 19 | 1 X 4 sq mm:- |
| 20 | 2 X 2.5 sq mm:- |
| 21 | 4 X 6 sq mm:- |
| 22 | 4 X 10 sq mm:- |
| 23 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required. |
| 24 | 32 amps DP kit kat switch:- |
| 25 | Ding dong call bell |
| 26 | Supplying and fixing of the following modular accessories including necessary connection etc. as required. |
| 27 | 5 step fan regulator (2M):- |
| 28 | Blank plate (1M):- |
| 29 | 20/25 amps single phase motor starter switch(2M):- |
| 30 | 3/6 pin 25 amps socket outlet (2M):- |
| 31 | Supplying and fixing of the following sizes PVC conduit (medium gauge) with all accessories on slab/recessed on wall etc. as required. |
| 32 | 19/20 mm dia |
| 33 | 25 mm dia |
| 34 | 32 mm dia |
| 35 | Supplying and fixing of the following sizes GI (in recess) and plastic (on surface) modular switch boards etc. as required. |
| 36 | 1-2 module GI switch board:- |
| 37 | Supplying and fixing of the following sizes modular type cover plates for GI/plastic modular switch boards etc. as required. |
| 38 | 1-2 module :- |
| 39 | Earthing with copper earth plate 600 mm x 600 mm x 3mm thick i/c accessories and providing masonry enclosure with CI cover plate size 12\\"x 12\\" having locking arrangement along with 20mm dia (medium gauge) watering pipe including CC work etc. as required. |
| 40 | Extra for using salt (12 kg) and charcoal (96kg) for pipe earth electrode as required. |
| 41 | Supply and fixing of 25mm x 3mm Copper on walls/ floor of the building for horizontal/ vertical network including necessary spacers and porcelain insulators at regular intervals. |
| 42 | Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12\\"x 12\\" having locking arrangement including CC work, holes on earth pipe etc. as required. |
| 43 | Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required. |
| 44 | Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required. |
| 45 | Supplying & fixing of 900 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod, canopies, shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated copper conductor cable (FR) |
| 46 | Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W) : - |
| 47 | Supplying & fixing of 1400 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod, canopies, shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated copper conductor cable (FR) (ISI marked) |
| 48 | Supplying & installation of 400 mm sweep AC wall mounting fan with plastic blade including connection etc as required:- |
| 49 | Supplying & installation of 225/230 mm sweep metalic body exhaust fan including connection etc as required:- |
| 50 | Supplying & installation of 300 mm sweep metalic body exhaust fan including connection etc as required:- |
| 51 | Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:- |
| 52 | Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required: |
| 53 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 54 | Surface mounted round/Square shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser:- |
| 55 | Surface mounted round/Square shaped 18/20 watt LED downlight with integral driver and high quality polycarbonate diffuser:- |
| 56 | Supplying and fixing of surface/recessed mounting CRCA powder coated housing 4ft x 1ft decorative 36 watt LED panel light fixture with integral driver, inbuild SPD >= 2.5 kV and high quality polycarbonate diffuser having and THD <=10%, luminous efficacy >120 lumen/watt & life expectancy of 50,000 burning hours including ncessary connection etc as required:- (with LM79 report from NABL accredited lab):- |
| 57 | Supplying and fixing of recessed mounting CRCA powder coated housing 2ft x 2 ft decorative 36 watt LED panel light fixture with integral driver, inbuild SPD >= 3 kV and high quality polycarbonate diffuser having and THD <=10%, luminous efficacy of 100 lumen/watt & life expectancy of 50,000 burning hours including ncessary connection etc as required:- (with LM79 report from NABL accredited lab):- |
| 58 | Supply and fixing of surface mounted 18/20 watt LED tube luminaire with powder coated finished 0.5 mm thick CRCA steel sheet housing including 1 no 18/20 watt LED tube having minimum system lumen output of 120 Lumens/watt & life expectancy of 50,000 burning hours with integral driver having 2 kV SPD and polycarbonate diffuser including connection etc as required (with LM79 report from NABL accredited lab):- |
| 59 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with precise street optic lens with heat resistant tempered glass/diffuser protection with IP66 and IK08/IK10 impact resistant including necessary connection etc. as required (50000 burning hours, THD ≤ 10% and minimum lumen output of 120 lm/watt with LM79 report from NABL accredited lab):- |
| 60 | 80 watt LED street light fixture with integral driver and secondary lens :- |
| 61 | 120 watt LED street light fixture with integral driver and secondary lens :- |
| 62 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 63 | 50 watt LED Flood light (IP 66):- |
| 64 | 40 watt LED post top light fixture with integral driver and high quality polycarbonate diffuser (IP 65):- |
| 65 | Supplying & installation of surface mounted PIR movement Sensor including necessary connection etc as required:- |
| 66 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required. |
| 67 | 2 way SPN MCB DB (single door):- |
| 68 | 4 way SPN MCB DB (double door):- |
| 69 | (2+10) /12 way SPN MCB DB (Double door):- |
| 70 | 4 way vertical TPN MCB DB suitable for FP MCB incomer (Double door):- |
| 71 | 6 way vertical TPN MCB DB suitable for FP MCB incomer (Double door):- |
| 72 | 8 way vertical TPN MCB DB suitable for FP MCB incomer (Double door):- |
| 73 | 6 way vertical TPN MCB DB suitable for FP MCCB incomer upto 125 amps (Double door):- |
| 74 | 8 way vertical TPN MCB DB suitable for FP MCCB incomer upto 125 amps (Double door):- |
| 75 | Supplying, installation, testing & commissioning of powder coated prewired panel board suitable for 415 volts TP MCCB as incomer & outgoing including busbar & connection as required of the following ratings & sizes:- |
| 76 | 4 way TP MCCB outgoing & TP MCCB incomer upto 400 amps:- |
| 77 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required:- |
| 78 | 6 to 32 amps SP MCB:- |
| 79 | 6 to 32 amps TP MCB:- |
| 80 | 40/50/63 amps TP MCB:- |
| 81 | Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required:- |
| 82 | 40 amps DP isolator:- |
| 83 | Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings):- |
| 84 | 16 to 100 amps TP MCCB, Breaking capacity 16/18KA (Thermal Magnetic):- |
| 85 | 125 amps TP MCCB, Breaking capacity 25KA (Thermal Magnetic):- |
| 86 | Supplying and fixing of thermoplastic cable junction box with connectors suitable for following sizes cable : - |
| 87 | 1.5 sqmm - 4 sqmm Cable:- |
| 88 | 16 sqmm - 50 sqmm Cable:- |
| 89 | Supplying and laying of following sizes XLPE insulated PVC sheathed copper conductor Un-armoured cable including necessary connection etc as required. |
| 90 | 3 core 1.5 Sq mm:- |
| 91 | Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required |
| 92 | 3 core 4 Sq mm:- |
| 93 | 4 core 25 Sq mm:- |
| 94 | 4 core 35 Sq mm:- |
| 95 | 3.5 core 70 Sq mm:- |
| 96 | Excavation of earth for cable trench of 800mm depth & 300mm width in all kinds of soil including back filling of cable trench with the excavated soil with 20cm layer of sand, 3.5 nos bricks per metre for protection including ramming, consolidating to the original shape as per dirrection of Site Engineer :- |
| 97 | Drawing of armoured/un-armoured cable with proper saddling etc as required:- |
| 98 | Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:- |
| 99 | 25 mm dia |
| 100 | 40 mm dia |
| 101 | Supplying and fixing of 70 mm top dia, 130 mm bottom dia, 3 mm thick hot dip galvanized 7 mtr long octagonal pole of base plate 220x220x12- mm with 1000 mm long single/double armed bracket with 70 mm top and foundation bolt and template etc. as required. ( BAJAJ / Philips/ Crompton/ K-lite Make ) |
| 102 | Single armred bracket |
| 103 | Double armred bracket |
| 104 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement- |
| 105 | 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size):- |
| 106 | Centering shuttering including struttings, propping etc. and removal of form work for: |
| 107 | Foundations, footings, bases for columns etc. for mass concrete with timber plank:- |
| 108 | 6 mm cement plaster in single layer including cost of materials required and finishing even and smooth and curing complete. |
| 109 | cement mortar 1 : 4 ( 1 cement : 4 fine sand ):- |
| 110 | Neat cement punning:- |
| 111 | Supplying and fixing of aluminium terminal ends (LUGS) - long barrel of following sizes: - |
| 112 | 25 sq mm |
| 113 | 35 sq mm |
| 114 | 70 sq mm |
| 115 | Supplying and installation of fuse unit kitkat/HRC/HBC of the following ratings in existing main switch/panel board including necessary connection etc as required:- |
| 116 | 200/250 amps kitkat porcelain fuse unit with base(rewireable):- |
| 117 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required. |
| 118 | Short Point :- |
| 119 | Medium Point :- |
| 120 | Long Point :- |
| 121 | Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 122 | Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:- Please Enable Macros to View BoQ information |