| 1 | Civil works for (1) Repair and renovation of SST-1 Vacuum control room at basement of SST-1 building at IPR Campus, Bhat, Gandhinagar-382428. |
| 2 | Removing of Wooden panel / PVC Sandwich panel with MS Framing, including cutiing of MS members, stacking of serviceable materials and disposal of unserviceable materials within 1 Km lead.. Rate includes scaffolding (if required). |
| 3 | Removing accoustic panel including binding material, stacking of serviceable materials and disposal of unserviceable materials within 500 m lead. Rate includes scaffolding (if required). |
| 4 | Removing / Dismantling Existing PVC flooring including removing of binding material in floors laid with gum/ fevicol/ any other binding material including cleainig of the surface to receive new flooring, disposing of the debris outside campus, stacking of useful material within 500 Rmt lead etc. complete as directed by engineer in charge. |
| 5 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints with white cement and matching pigment Size of Tile 600x600 mm or as decided by EIC. |
| 6 | Dismantling Gypsum false ceiling along with grid including disposal of unserviceable material and stacking of serviceable material with in 500 meters lead as directed by Engineer-in-charge |
| 7 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. |
| 8 | Providing and constructing HALF BRICK MASONRY walls/partitions in following mixes using approved well burnt bricks of \\"CLASS DESIGNATION\\" (Classification as per I.S. 1077-1986) as specified below, including scaffolding, raking out joints, curing, etc; at all lead and lifts all as directed by the Engineer -in- charge. In SUPERSTRUCTURE UPTO FLOOR-V LEVEL. (The mix ratio specified is for cement : coarse sand) Using bricks of \\"class designation 3.5\\"(Minimum Average Compressive Strength not less than 3.5N/sqmm) In cement mortar 1:4 Complete all as directed by EIC. Price includes fixing of chair bracket/rag bolt into masonary. |
| 9 | Cement plaster 1:3 (1 cement : 3 course sand) mala finished 20 mm cement plaster.Note:-Including Scaffolding, curing etc. |
| 10 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area 3 sq. metres & below |
| 11 | Removing dry or oil bound distemper, plastic emulsion paint, limewash, colourwash, and the like by scrapping, sand papering, grinding and preparing the surface smooth including necessary repairs to scratches etc. complete.Note:- Removing of emulsion paint, white wash, oil paint or enamel paint ,wood work, steel work etc. by sand paper, wire brush, roll paper etc. to receive fresh coat of paint is also covered under item. Rates includes scaffolding. Measurements will be done as per relevant IS Code. Complete all as directed by EIC. |
| 12 | Providing and applying white cement based putty two or more coat to achieve required finish on wall, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.Note:-for internal walls only, Rates includes scaffolding and sand papering of wall after putty. The thickness of putty should be 0.50 mm or more. Measurements will be done as per relevant IS Code |
| 13 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface (or oil based primer for AC Duct only) having VOC content less than 50 grams/ litre.Note:- For Internal wall only, Rates includes scaffolding at all height. Measurements will be done as per relevant IS Code. Complete all as directed by EIC. |
| 14 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour In TWO or more coat.Note:- Rates includes appropriate scaffolding for all height, crack opening and filling with approved filler material (filling cracks - SBR polymer with cement as per manufacturers specification). Measurements will be done as per relevant IS Code. Complete all as directed by EIC. |
| 15 | Treatment of soil under existing RCC floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration (Chemical will be paid in respective item) |
| 16 | Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS: 8183. Density 48 kg/m³, 50 mm thick, wrapped in 200G Virgin Polythene bags placed in between compact sheets for sound proof partition and held in position by criss-crossing GI wire. |
| 17 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge.Note - 1. Item to be applicable in urban areas having directions for restricted hours for movement / plying of load carrying motor vehicle of 3.5 cum or more.2. Voids @20% for solids and 50% for rock shall be dedcuted from fully loaded truck measurement to arrive at the net quantity for payment in case of direct measurement is not possible.3. The cost is inclusive of necessary permisiion from statutory authorities for dumping the debris/excess earth outside department premises4. Debris generated for dismantling items of BOQ will be considered in this item only. Other debris generated during work will be disposed by contractor at their own expense. |
| 18 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including ecessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). |
| 19 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including ecessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber. locking arrangement for sliding window, Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868,Minimum anodic coating of grade AC 15)- Please Enable Macros to View BoQ information |
| 20 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including ecessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber. locking arrangement for sliding window, Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868,Minimum anodic coating of grade AC 15)- Please Enable Macros to View BoQ information |