| 1 | Earth work excavation of foundation in hard soil within initial lead of 50m and initial lift of 1.5m including dressing the sides, leveling the bed and depositing the excavated materials away from the work site, shoring etc if required, complete the item of work in all respect as per direction of the Engineer-in-charge. |
| 2 | Filling foundation and plinth with filling sand laying in layers including ramming, watering, compacting including cost, conveyance and royalty of sand from approved quarry and other taxes if any with all leads, lifts, T&P etc complete the items of work in all respect as per specification and direction of Engineer in charge. |
| 3 | Filling foundation and plinth with excabated earth completed with all |
| 4 | CC (1:3:6) using 40 mm size and down graded crusher broken HG stone metal free from weathered surface of approved quality from approved quarry in foundation and plinth including laying concrete in layers with due compaction, watering and curing including cost, conveyance, royalty and taxes of all materials with all lead, lifts and delifts, T&P etc required for completion of the work in all respect as per direction of the Engineer-in-charge. |
| 5 | Brick work with Flyash bricks of size 25 cm X 12 cm X 8 cm having crushing strength between 100 kg/cm2 to 149 kg/cm2 in cement mortar (1:6) in foundation & plinth including cost, conveyance, royalty, taxes of all materials, labour, T&P required for the work complete and as per the direction of the Engineer-in-charge. |
| 6 | RCC work of M-20 grade with 20 mm and down grade black hard granite chips including cost, conveyance, royalty and all taxes of all materials with all leads, lifts, T&P etc. including rigid and smooth centering, shuttering and dismantling the same after the curing of RCC work for 28 days complete the item of work in all respect as per specification and direction of Engineer-in-charge |
| 7 | Column base & Footing |
| 8 | Plinth Bend |
| 9 | Column & Beam Ground Floor |
| 10 | Lintel Band Ground Floor |
| 11 | Chhaja and loft Ground Floor |
| 12 | Beam Ground Floor |
| 13 | Roof Slab Ground Floor |
| 14 | Fins Ground Floor |
| 15 | Labour charges for straightening coiled or bent up MS rods including cutting, bending and welding if required and tying the grills, laying and placing in proper position as per design including cost, conveyance, taxes etc of tested MS/TS rod with testing data of required specification & cost of binding wires of 18 to 20 gauge, labour, T&P required for the work complete and as per the specification and direction of the Engineer-in-charge. |
| 16 | GROUND FLOOR |
| 17 | Brick work with Flyash bricks of size 23 cm X 11 cm X 8 cm having crushing strength between 100 Kg/cm2 to 149 kg/cm2 in cement mortar (1:6) in superstructure including cost, conveyance, royalty, taxes of all materials, labour, T&P required for the work complete and as per the direction of the Engineer-in-charge. |
| 18 | GROUND FLOOR |
| 19 | 12mm thick cement plaster (1:6) in cement mortar finished smooth surface on brick wall after racking out joints including watering curing to required period including cost conveyance, royalty of all materials, T&P complete etc. as per specification and direction of Engineer in charge. |
| 20 | GROUND FLOOR |
| 21 | 16mm thick cement plaster (1:6) in cement mortar finished smooth surface on brick wall after racking out joints including watering curing to required period including cost conveyance, royalty of all materials, T&P complete etc. as per specification and direction of Engineer in charge. |
| 22 | GROUND FLOOR |
| 23 | 6mm thick cement plaster in cement mortar (1:4) to RCC surface finished including watering curing to required period including cost conveyance, royalty of all materials, T&P complete etc. as per specification and direction of Engineer in charge |
| 24 | GROUND FLOOR |
| 25 | Supplying of MS Door, windows with Grills, Grills, Collapsible gates made out of M.S Angle frame, M.S Flat Sheet etc. of approved section and design, Electrically Welding Properly with all necessary locking arrangement and one coat redoxide Primer including cost of all materials, labour, T&P, carraiga of Materials to site etc. complete as per the direction of the Engineer-in-charge. |
| 26 | GROUND FLOOR |
| 27 | Providing and fixing of fixed Ventilators of approved make to be fabricated from roll formed sections made of pre-painted steel (base steel as per IS- 513 of 0.6 mm thick “D” quality, galvanized as per IS-277 with zinc of 120 Gm/Sq.mtr) with paint pecification being with primer of 5-7 microns and finished paint with polyster paint (Black /Pearl white/ Chocolate Brown) of 12-16 microns alongwith the alkyd backer at the back of 5-7 microns and the sizes of outer frame being of 46x52 mm and with all vertical and horizontal mullions are of 46x70 mm and fixed beadings are of 18x25 mm. Section for internal top and bottom frames in the louvered areas should be 18 x 40 mm. Top hung shutter should be of 46 x 46 mm. Accessories / gaskets are to be used as per the manufacturer’s supply and specification like handle being made of high grade aluminium powder coated and with nylon receiver and gasket will be made of EPDM. All corner brackets are to be made of CRCA with zinc phosphating. The mullion caps and louvered-clips should be of glass filled nylon. The sections are to be cut to length ,mitre joined with corner bracket and frames are fixed to the concrete/masonry walls by means of self expanding screws and glass to be used of 5mm reflective with cost, conveyance and taxes of all materials, cost of all labour, T&P etc. complete as per the direction of the Engineer-in-charge. |
| 28 | GROUND FLOOR |
| 29 | Supplying, fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixing as per the direction of the Engineer-in-charge. |
| 30 | GROUND FLOOR |
| 31 | Supplying, fitting and fixing of openable UPVC door with door frame and approved make with 6m thick glass of approved quality complete with frame shutter and all fittings and fixture as per the direction of the Engineer-in-charge. |
| 32 | GROUND FLOOR |
| 33 | Providing & Fixing of Acoustical Mineral Fibre Board of RH-99 with microperforated,finely granulated surface texture , beveled tegular edge with 6mm Black Revealed exposed grid Suspended False Ceiling System, with tiles of Humidity Resistance (RH) of 99%, NRC Upto 0.5, αw value 0.6, CAC- 34dB ,Light Reflectance >85%, thermal Conductivity k = 0.052- 0.057 w/m K, Colour White, Fire Performance Class- 0/ Class -1 (BS476 Part 6&7) in module size of 600 X 600 X 16 mm with Bio Block coating on the face of the tile, suitable for Green Building application, with Recycled content of 63%, fixed to G.I.grids of system with 15mm white flanges incorporating a 6mm central reveal in white/black colour and with a web height of 38mm , having stiches both perpedicular and horizontal to make it stronger, and a load carrying capacity of minimum 15.68 Kgs/Sqm. The Main Runners & Cross Tees to have mitred ends & “birdsmouth” notches to provide mitred cruciform junctions. The T Sections have a Galvanizing of 120 grams per SQM & passed through 500 hrs of Salt test. The Tile & Grid system used together should carry a 15 year warrantee. The main G.I. runner spaced at 1200mm centre to centre securely fixed to the structural soffit using G.I. suspension system at 1200mm maximum centr to centre & not more than 150mm from spliced joints. The First/Last suspension system at the end of each main runner should not be greater than 600mm from the adjacent wall. 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm modules to be formed by fitting 600mm long cross tees centrally between the 1200 mm cross tees. The 1200mm cross tees to have central “birdsmouth” notches to facilitate fitting of 600mm cross tees. Perimeter trim to be shadow wall angle (dimensions: 19x7x7x14mm), secured to walls at maximum 450 mm C/C,complete in all respect with all cost ,labour,T & P,Taxes etc as per direction of the Engineer - in - charge. |
| 34 | GROUND FLOOR |
| 35 | Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30 mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality incuding cost of all door fittings and fixtures etc. complete |
| 36 | GROUND FLOOR |
| 37 | Supplying fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90 mtrs C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in staircase as per approved design and specification, buffing, polishing etc with coist, conveyance, taxes of all materials, labour and T&P required for the work all complete in all respect |
| 38 | GROUND FLOOR |
| 39 | Supplying, fitting and fixing vitrified tiles in floors of size 600mm x 600mm of approved make confirming to IS: 13755 laid on 20mm thick cement mortar 1:4 (1 cement : 4 sand) and filling joined with white cement of approved quality including cost, conveyance, royalty, taxes of all materials, labour, T&P required for the work complete and as per the direction of the Engineer-in-charge. |
| 40 | GROUND FLOOR |
| 41 | Supplying, fitting and fixing vitrified tiles in dado, skirting and risers of steps on 12mm thick cement plaster (1:3) joint with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing, cost, conveyance, royalty, taxes of all materials, labour, T&P required for the work complete and as per the direction of the Engineer-in-charge. |
| 42 | GROUND FLOOR |
| 43 | Supplying Fitting & Fixing of Industrial Vetrified Tile on Floor Inlcuding all cost etc. complete |
| 44 | GROUND FLOOR |
| 45 | Supplying Fitting & Fixing of Industrial Vetrified Tile on Dados Inlcuding all cost etc. complete |
| 46 | GROUND FLOOR |
| 47 | Supplying, fitting & fixing of Ceramic Floor tiles (30x30,40x40) with water absorption limit between 0.08% to 3% and conforming to IS : 15622:2006 (Group B Ib). laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge (for New Work only ) |
| 48 | GROUND FLOOR |
| 49 | Supplying, fitting and fixing Ceramic tiles in dado, skirting and risers of steps on 12mm thick cement plaster (1:3) joint with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing, cost, conveyance, royalty, taxes of all materials, labour, T&P required for the work complete and as per the direction of the Engineer-in-charge. |
| 50 | GROUND FLOOR |
| 51 | Supplying, fitting and fixing granite tiles in floors, treads on steps and landing on 25mm thick bed of cement mortar 1:1 (1 cement: 1 sand) joined with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing, cost, conveyance, royalty, taxes of all materials, labour, T&P required for the work complete and as per the direction of the Engineer-in-charge. |
| 52 | GROUND FLOOR |
| 53 | Supplying Fittings & Fixing of Granite Tile on Dados including all cost etc. complete |
| 54 | GROUND FLOOR |
| 55 | Painting two coats with approved Enamel Paint on wood work and Steel work |
| 56 | GROUND FLOOR |
| 57 | Providing Acrylic Wall Putty (Cement Based & Water Based) including all cost etc. complete |
| 58 | GROUND FLOOR |
| 59 | Providing Plastic Emulsion Paint (2 coat) over a coat of Primer including all cost etc. complete |
| 60 | GROUND FLOOR |
| 61 | Finishing to walls with two coats Distemper paint over one coat primer and plastic emulsion paint of approved brand and approved colour including cleaning the surface with cost, conveyance, royalty taxes of all materials labour T&P and scaffolding as required for the work and as per specification and direction of Engineer-in-charge. |
| 62 | GROUND FLOOR |
| 63 | Finishing to walls with two coats weather coat over one coat primer and weather coat paint of approved brand and approved colour including cleaning the surface with cost, conveyance, royalty taxes of all materials labour T&P and scaffolding as required for the work and as per specification and direction of Engineer-in-charge. |
| 64 | GROUND FLOOR Please Enable Macros to View BoQ information |