| 1 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish to a distance out side MD land complete all as specified and as directed. |
| 2 | Demolition of Cement concrete (including cutting of reinforcement if any) in any description and any position not otherwise specifically provided for and removing debris out of MD land, complete all as specified and as directed. |
| 3 | M&L for 25 mm thick Plain cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in sub base of flooring, including. finishing the surface even & rough to receive tiling etc., complete all as specified and directed. |
| 4 | M&L for 15-18mm thick machine cut Udaipur green marble, (size & shape, shade and pattern as approved by GE) as in cooking platform over & including M&L 15mm thick screed bed in cement mortar (1:4) and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including polishing and rounding the edges, complete all as specified and directed. |
| 5 | M&L for 18 - 20 mm thick (telephone black shade) granite stone, as in WHB counter top, steps, jambs, pillars, window cills & similar nature works, machine cut, (table rubbed and polished) best quality as per sample, over & including 15 mm thick screeding in CM1:4 including rounding & double mouldlng with jointless finish of the edges, including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.providing suitable dia hole in the slab for the gas pipe, complete all as specified and as directed. |
| 6 | M&L of 18-20mm thick machine cut KOTA stone slab as in floor (size not less than 580mm x 580mm) , treads, steps etc(Single piece for steps), machine cut, laid over cement and jointed with grey cement slurry with pigment to match the shade of the slab, incl rubbing and Mirror polishing all as specified as in floors over and including 15mm thick in screed bed in CM (1:6), complete all as specified and as directed. |
| 7 | M&L of 18-20mm thick machine cut KOTA stone slab riser of step , skirting, dado etc(Single piece for steps), machine cut, laid over cement and jointed with grey cement slurry with pigment to match the shade of the slab, incl rubbing and Mirror polishing all as specified including backing coat of 10mm thick in CM (1:4), complete all as specified and as directed. |
| 8 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed. |
| 9 | M&L for coloured glazed ceramic tiles Area exc .0.13 sqm but not exc 0.36 sqm as per IS 13712 Grade II(a) over and include15mm thick rendering in CM (1:6) set and jointed in neat cement slurry and pointed with colour cement to match on vertical surfaces as in dado, Skirting (colour and pattern as approved by GE) complete all as specified and directed. |
| 10 | M&L for coloured non skid ceramic tiles area exc 0.09 sqm and not exc 0.36 sqm as per IS 13712 Grade II(a) in floor etc set jointed and pointed in white or coloured cement to match as in floors over and including 15mm thick screed bed in CM (1:6) complete all as specified and directed. |
| 11 | M&L for double charged Vitrified Ceramic tiles, 9-10 mm thick, (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15mm thick screed bed in CM (1:6), complete all as specified and directed. |
| 12 | All as per item No. 11.00 here-in-above, but as in dedo/skirting including 10 mm thick rendering in CM 1:4 set and backing coat. |
| 13 | M&L for treating the surface with beeswax polish to terrazzo tile floors, marble, granite, kota stone etc for complete all as specified and directed |
| 14 | S&F in replacement anodised aluminium snap grid frame work ( 605x605 mm) for false ceiling, including dismantling of existing false ceiling, etc complete, as specified and directed. |
| 15 | S&F Exposed metal frame ceiling with calcium silicate board (laminated both side) 6mm thick of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid, complete, as specified and directed.Note:- Frame work for ceiling shall be measured and paid separately. |
| 16 | M&L for Gl frame work size of grid 605 x 605mm for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre and Hangers 6 mm dia. G.I. (upto1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and including S&F gypsum board 12mm thick in ceiling fixed with screws as per manufacturers instructions over the frame work and preparation of ceiling board and applying two coats of oil bound distempe over a coat of 'Birla wall/ceiling cate putty including dismantling of existing false ceiling of any thickenss wiht cover fillets molsing, risers complete all as specified and as ditected. |
| 17 | M&L for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing, complete all as specified and as directed. |
| 18 | S&F in replacement solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on wall/ PVC frame as per specifications, including old existing u/s wall lining and complete all as specified and directed. |
| 19 | Taking down cement plaster, any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off the premises and leaving the work clear of any plastering complete all as specified & directed. |
| 20 | M&L for 15 mm thick rendering in CM 1:6 on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing finished surface even and smooth without using extra cement, complete all as specified and as directed. |
| 21 | M&L for 10 mm thick Rendering in CM 1:4 on fair faces of brick work or conc surfaces as in ceilings/chajja/facia & finished even & smooth w/o using extra cement, complete all as specified and as directed. |
| 22 | M&L for Racking out joints/ pointing to squared rubble or polygonal rubble un-coursed or brought up to courses masonry built in cement mortar or cement lime mortar, coursed or un-coursed in walls not less than 12mm deep, washing the joints, removing rubbish off the premises and keeping the surface to pointed or plastered wet for two days prior to re-pointing or plastering complete all as specified & directed. |
| 23 | M&L keyed pointing in cement mortar (1:3) to squared rubble masonry regular coursed or un coursed, complete all as specified & directed. |
| 24 | M&L for preparation of new plastered or unplastered surfaces of walls and applying 2 mm thick Birla/JK wall care putty and two coats of oil based distemper (white or tinted) over & including M&L for single coat of primer on wall complete all as specified and as directed. |
| 25 | M&L for preparation of new plastered or unplastered surface of ceiling and applying two coats of OBD over & including M&L for single coat of primer, complete all as specified and directed. |
| 26 | M&L for preparation of new/old plastered/unplastered surfaces of wall & applying two coat of interior emulsion paint (plastic paint) over & including M&L for single coat of (Birla) wall care putty , complete all as specified & as directed. |
| 27 | M&L for preparation of new/old plastered or unplastered wall surface and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified & as directed. |
| 28 | M&L for complete removal of existing treatment of wall surfaces and applying two coats of cement based paint over & including M&L single coat of Primer on wall, complete all as specified and as directed. |
| 29 | M&L for preparation of old painted surfaces of walls or roofs by brooming down or steel wire brushing, scraping down smoke spot, moulds, moss and efflorescent salt and greasy spots and applying one coat of cement base paint, complete all as specified and directed |
| 30 | M&L for Preparation of new plastered or unplastered surfaces of wall and applying three coats of white wash on wall surfaces complete all as specified and as directed. |
| 31 | M&L for Preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white wash on ceiling surfaces complete all as specified and as directed. |
| 32 | Taking down chowkhats or frame with shutters (without taking of shutters from the frames) area not exc 1.5 Sqm each, complete all as directed. |
| 33 | Taking down chowkhats or frame with shutters (without taking of shutters from the frames) area exc 1.5 Sqm but not exceeding 4 Sqm each, complete all as directed. |
| 34 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/ Chowkhat of size 45 x 85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately) complete all as specified and directed. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account. |
| 35 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing opening as per specification & drawing complete all as specified and as directed. |
| 36 | M&L for Framed work as in doors or gates Fe 410-w A quality of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed. |
| 37 | M&L for PCC 1:2:4 type B1 Mix using 20mm graded stone aggregate as in bed block for hold fast including necessary form work all as specified. |
| 38 | Taking down steel windows and ventilators ( glazed / fly proof) of any description complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 39 | Taking down steel windows and ventilators ( glazed / fly proof) of any description complete all as specified and as directed. Please Enable Macros to View BoQ information |