| 1 | M&L for carrying out complete waterproofing treatment to roof surfaces including complete removal of existing waterproofing treatment of any description including PCC in any position, cleaning the surface by wire brushing and washing and disposal of debris to a distance not exceeding 1500 m, preparation of surface by removing all loose particles, applying a coat of water based bituminous primer @ 0.40 litre per sqm and applying a uniform coat of hot blown bitumen of grade VG-10 @ 1.20 kg per sqm conforming to IS 702, providing PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) 25 mm thick as levelling course, forming cement concrete kerbs/mud stops, rendering 10 mm thick in cement mortar 1:3 finished even and smooth, and laying APP modified polymeric waterproofing membrane conforming to IS 16540/IS 16532, minimum 3 mm thick and weighing not less than 3.5 kg/sqm, reinforced with polyester non-woven fabric (minimum 150 gsm), laid with minimum 100 mm overlaps and fixed by torch application, including sealing of joints and edges, and finishing the surface with solar reflective aluminium paint @ 0.10 litre per sqm complete all as per manufacturer’s instructions and as specified and directed. Note : a)The rate quoted shall include all materials, labour, scaffolding, surface preparation, overlaps, wastage and complete waterproofing system. Nothing extra shall be paid. b) Integral waterproofing compound (WPC) shall be measured and paid separately under relevant item of BOQ. |
| 2 | Supply only integral water proofing liquid complete all as specified and directed. (@200ml per bag of cement) |
| 3 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position capacaity 500 litres (Cleaning repairing, etc. measured separately) complete all as specified and directed |
| 4 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position capacaity 1000 litres (Cleaning repairing, etc. measured separately) complete all as specified and directed |
| 5 | S&F rotational moulded polyethylene water storage tank of 1000 litres capacity (triple layer) cylindrical vertical with closed top, conforming to IS 12701, of approved make, hoisted and fixed in position including providing and fixing inlet, outlet, overflow and washout connections with suitable fittings, complete all as specified and directed |
| 6 | S&F rotational moulded polyethylene water storage tank of 500 litres capacity (triple layer) cylindrical vertical with closed top, conforming to IS 12701, of approved make, hoisted and fixed in position including providing and fixing inlet, outlet, overflow and washout connections with suitable fittings, complete all as specified and directed |
| 7 | S&F in repairs ball valves, high pressure, with of PTMT with epoxy coated aluminium rod & high desity plastic ball screwed for iron pipe of 25 mm bore (Minimum weight 455 gms )and fixed complete all as specified and directed. |
| 8 | S&F in repairs 20mm dia of gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 9 | Taking up or down steel tubing and connections, including removal to store etc complete all as specified and directed for 20 mm bore |
| 10 | Taking up or down steel tubing and connections, including removal to store etc complete all as specified and directed for 25 mm bore |
| 11 | S&F Unplasticised PVC pipes and fittings of 20mm dia of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and directed |
| 12 | S&F Unplasticised PVC pipes and fittings of 25mm dia of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and directed |
| 13 | Taking down plastering on lathing (other than wire-netting), without removing lathing, in cement or cement-lime mortar (one side only measured in cases where both sides are plastered) etc complete all as specified and directed directed |
| 14 | M&L rendering 10mm thick on surface of brick /concrete surface in CM 1:3 complete all as specified and directed surfaces finished fair and even on ceilings all as specified and directed directed |
| 15 | M&L rendering 10mm thick on wall/vertical surface of brick work/concrete work in CM 1:6, surfaces finished even and smooth without using extra cement all as specified and directed. |
| 16 | M&L for 5mm thick cement plaster in CM 1:4 mixed with approved water proofing compound as per manufacturer's instructions over 10mm thick backing coat in CM 1:6 finished fair and even complete all as specified and as directed. |
| 17 | M&L for preparation of newly plastered surfaces and applying three coats of white wash on ceilings complete all as specified and directed |
| 18 | M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash on walls complete all as specified and directed |
| 19 | M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed |
| 20 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed |
| 21 | M&L for perforated particle board/tiles for acoustic and insulation purposes, 600 mm x 600 mm x 12 mm thick, of approved make, fixed to timber framework with nails or to aluminium snap grid with staples/clips including necessary fixing accessories complete all as specified and directed |
| 22 | S&F anodised aluminium snap grid framework for false ceiling comprising main runners, cross runners and wall angle sections of approved make, suspended from roof/ceiling by means of GI hangers 6 mm dia with cleats, expansion bolts/dash fasteners and other necessary fixing accessories at required spacing, including levelling and alignment of grid complete all as specified and directed |
| 23 | S&F false ceiling of Non asbestos fibre cement building boards, manufactured from homogeneous mixture of cement, quartz and cellulose and cured with high pressure steam using auto claving process confirming to IS-14862, of size 600 mm x 600 mm x 4 mm thick fixed over snap grid frame work of T section (main & cross member) of size 25 mm x 25 mm x 1.5 mm thick in square pattern of grid size 600mm X 600mm . The aluminium fram work will supported on side wall with the used of aluminium 'L' section of size 25 mm x 25 mm x 1.5 angles etc. Snap grid shall be supported with hangers of 4 mm dia. Galvanised iron wire adjusting level fixed to roof slabs / truss etc by means of ceiling cleats made out of Galvanised iron flat of size 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long complete all as specified and directed including necessary removal of existing electrical fittings and re-fixing in position without disturbing existing connected fittings . |
| 24 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed |
| 25 | Supply and fixing Prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in roof covering/ cladding to wall fixed with self tapping screws all as specified and as directed. |
| 26 | Supply and fixing Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550 Mpa as in roof covering / cladding (ridge / valley gutters) fixed with self tapping screws complete all as specified and as directed. |
| 27 | S&F 2mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc., complete all as specified and as directed. |
| 28 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed |
| 29 | S&F PVC in repairs (SWR) of dia 160 mm rain water pipes conforming to IS 13592 type 'B' including necessary rubber ring joints fix with valley gutter along wall or clading all as specified and directed. |
| 30 | S&F 160 mm dia PVC (SWR) bends any radious all as specified and as directed. |
| 31 | M&L for holes filling in pre-painted galvalume plain or corrugated steel sheets in hangars with butyl adhesive aluminium waterproof heavy duty leakage repair flashing tapes of size 40 to 60mm length and width and etc all as specified and directed. |
| 32 | Dismantling wrought iron or mild steel work of any description complete all as specified` |
| 33 | S&F MS Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 etc complete all as specified and directed |
| 34 | S&F Mild Steel hand rails, half round or other stock section or core for wooden hand rail straight portion, drilled and counter sunk for balusters running bars for doors, balusters, nosing to steps including embeding in concrete and screwing, etc,. wind ties for roof including securing bolts; post and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh, etc.,), bolting or riveting, etc., and similiar work confirming to Fe-290 Gde E-165 all as specified and as directed . |
| 35 | Material & Labour for preparing new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of Synthetic enamel paint over a coat of Red oxide zinc chrome primer, complete all as specified and directed. |
| 36 | Material & Labour for preparing new steel Surfaces of any description, n.exc 10cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coats of Synthetic enamel paint over a coat of Red oxide zinc chrome primer, complete all as specified and directed. |
| 37 | S&F in repairs high performance industrial roof ventilator of 600 mm dia neck made of aluminium alloy, designed to meet ASS-2428 dated 28 Jan 1993, suitable for wind speed up to 200 kmph and resistant to entry of wind driven rain up to 2.5 litres per second, complete with base plate and all necessary fixing accessories, including dismantling of unserviceable unit if required and fixing in position complete all as specified and directed |
| 38 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. complete all as specified and directed. |
| 39 | M&L for dark shade vitrified ceramic tiles10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 20mm thick screed bed in CM (1:4) all as specified and directed |
| 40 | As per item No.39.00 above but on vertical surfaces such as skirtings, dados and risers to steps etc over 10mm thick rendering in CM (1:3) all as specified and directed |
| 41 | M& L Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed |
| 42 | As per item No.41.00 above but on vertical surfaces such as skirtings, dados and risers to steps etc over 10mm thick rendering in CM (1:3) all as specified and directed Please Enable Macros to View BoQ information |