| 1 | 'Notes: (i) Please refer Schedule 'A' Notes of tender documents. |
| 2 | Taking down cement or cement lime plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed. |
| 3 | M&L for 15mm thick cement plastering in cement mortar 1:4 and mixing the water proofing compound as per manufactures instructions on brick or concrete surface of wall finished complete all as specified and directedNote : Water proofing compound shall be measured and paid separately under item |
| 4 | M&L for 10mm thick cement plastering in cement mortar 1:6 finishing the surface complete all as specified and directed. |
| 5 | M&L preparation of new plastered or unplastered surface of walls and applying two coats of distemper oil emulsion over complete all as specified and directed. |
| 6 | M&L Preparation of new plastered or unplastered surfaces of walls, two coats of cement base paint complete all as specified and directed. |
| 7 | Supply only integral water proofing compound ISI marked complete all as specified and directed. |
| 8 | Demolition of brick work built in cement mortar complete all as specified and directed. |
| 9 | M&L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in in cm 1:4 with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius complete all as specified and directed. |
| 10 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 11 | S&F for pre painted, pre crimp curved galvalume aluminium zinc coated GI based corrugated steel sheet 0.50mm thick (colour as directed by Engr-in-Charge) having tensile strength of 550 Mpa as in structure of semi circular/Hemi spherical shape, fixed to self tapping screws with proper curve of the original structure complete all as specified and directed. |
| 12 | S&F pre- painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in ridges, roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 13 | Demolition of reinforced cement concrete of any description (Reinforcement cut as required to facilitate demolition ) complete all as specified and directed. |
| 14 | M&L for reinforcement cement concrete (Normal mix )1:2:4 Type B1 (20mm graded aggregate) as in slab support on wall , beams and columns, footing and roof landing balconies deck slab and in shelves and the like complete all as specified and directed. |
| 15 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, finished flat rough finished surfaces etc. complete all as specified and directed. |
| 16 | S&F Mild steel TMT bars as in reinforcement 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 17 | As per Item No. 16 here-in-before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed. |
| 18 | Dismantling wrought iron or mild steel work of any description complete all as specified and directed. |
| 19 | M&L for rolled sections as in main and cross beams, hip and jack rafters purlins, where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates to Fe-290 (Gde E-165) complete all as specified and directed. |
| 20 | M&L for preparation old steel surfaces of any description and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 21 | M&L for preparing surfaces of any description over 10 cm girth or width, not otherwise described and applying two coats of synthetic enamel paint over a coat of Red oxide on new surfaces of steel or iron, complete all as specified and directed. |
| 22 | Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified and directed. |
| 23 | S&F Powder coated Pressed steel frames made of MS sheet of 1.25 mm thickness for doors with single rebate including necessary fixing lugs, hinges, lock strike plate, hold fasts ,filling PCC (1:3:6 Co) in chowkhats , PCC 1:2:4 B1 hold fast blocks etc., complete as specified, size 105x 60mm including cutting holes and making good reqd to shape for hold fast blocks for new frame complete all as specified and directed. Note :- Disturbed portion of existing floor /wall / tile / plaster etc during fixing of chowkhats shall be repaired to match with existing finish .Cost of the same will be included in this item. |
| 24 | S&F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 25 | S&F Mild steel sliding door bolt of size 250mm , stove enamelled black with bright bolt not less than 16mm dia, with and including a minimum of 6 bolts and nuts, complete all as specified and directed. |
| 26 | S&F MS pressed handles of size 125mm oval type stove enamelled black complete all as specified and directed. |
| 27 | Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level), complete all as specified and directed. |
| 28 | M&L for machine cut Kota stone slab flooring 20mm (+2mm) thick laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 as base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over 25mm thick cement concrete type B-0 (12.5mm graded aggregate) complete all as specified and directed. |
| 29 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out soft/loose soil complete all as specified and directed. |
| 30 | Use & waste of formwork to sides and soffits of floor and roof beams ,lintels beam ,cantilevers ,shelves including supports ,overhangs and similar work , for rough finished flat surfaces complete all as specified and directed. |
| 31 | Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m complete all as specified and directed. |
| 32 | M&L for hardcore of gauge n.exc. 63 mm, deposited, spread and levelled in layers n.exc. 15 cm thick, watered and rammed to a true surface using broken stones or boulders, complete all as specified and directed. |
| 33 | M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base of flooring, complete all as specified and directed. |
| 34 | M&L for 25mm thick PCC (1:2:4) type B-0 using 12.50 mm graded crushed stone aggregates complete all as specified and directed. |
| 35 | S&F Pumping sets, centrifugal, electric driven, supply and Install complete upto 15 HP. 415 volts, 50 Hz, 3000 RPM, energy efficient power rating upto 11 KW, LPM not less than 460 LPM and head not less than 46 mtr inclusive Fully Automatic Star Delta Starter & OEM recommended size PCC foundation complete all as specified and directed |
| 36 | S&F Steel water tubing, 150 mm(6”) dia bore, medium grade, galvanised with all fittings and laid in trenches/ surface complete all as specified and directed. |
| 37 | Supply and fix CI Foot Valve conforming to IS 4038, 150 mm (6”) dia complete all as specified and directed. |
| 38 | Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 39 | Supply and fixing Weather proof flat twin core cable with aluminium conductor, 1100 volts grade, cross-sectional area 2.5 Sqmm, 2 core laid on poles / walls complete including connection to LT pole and street light control box complete all as specified and directed. |
| 40 | Supply and fix of MCB SPN 6-32 Amp ('B' Curve) complete all as specified and directed. |
| 41 | Supply and fixing of 2 Way DB box for SPN MCB complete all as specified and directed. |
| 42 | Supply and laying XLPE insulated, PVC bedded galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 6.0 sqmm 4 core laid in trenches/on poles/walls/in ducts/passing through pipes and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed. |
| 43 | M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized galvanised iron strip 25×4mm as earthing lead or earth wire 4mm dia by means of nuts bolts, washers, check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frame 40x40x6mm. and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade protection pipe including excavation and charcoal ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I complete all as specified and directed. |
| 44 | Supply & fixing of Non Return Sluice Valve including fitting 150 mm (6\\") dia complete all as specified and directed. |
| 45 | Excavation in trenches in soft soil not exceeding 1.50 metre wide & not exceeding 1.50 metre deep for foundation ,for laying of water supply pipe line in trenches and getting out including dressing/trimming sides and levelling, grading and ramming of bottom of excavation complete all as specified and directed. |
| 46 | Returning, filling in, including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, excavated soil in trenches after pipes have been laid and tested, complete all as specified and directed. |
| 47 | Removing excavated surplus spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 48 | M&L for sand cushioning, spreading, levelling and well ramming to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified and directed.Note : Only punned sand shall be measured. |
| 49 | Supply and laying well burnt sub class ‘B’ bricks. ( designated 75) locally available best quality laid dry in trenches for protection of underground cable complete all as specified and directed. |
| 50 | Material and labour for of GI tubing light grade 40 mm bore for passing through cables along the pole & wall, under the floor complete all as specified and directed. |
| 51 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete with fittings and fixtures such as switches, ceiling roses, pendants, regulators, socket, lamp holders brackets, bulk head fittings etc removing material for taking credit ( credit shall be recovered as per credit Sch attached) and also making good disturbed surfaces of wall, floors etc complete all as specified and as directed. |
| 52 | M&L for point wiring with 1.50 sqmm in copper conductor cable ( multistrand) FRLSH single core PVC insulated cable in and including PVC concealed conduit (ISI Marked) of heavy duly with all accessories ie PVC gutties etc terminated in sunken/pressed metal flush box and white modular cover plate with frame for mounting of switches /sockets/ fan regulators etc and continuous earth wire 1.5 Sqmm copper cable PVC insulated FRLSH controlled by one switch for one light/fan/sockets point/ complete all as specified and directed in ceiling Portion surface conduit wiring to be done. . Note : i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost ii) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth. iii) Necessary cutting chasing wherever required and making good the disturbed surface shall be part of job at no extra cost. iv) The wiring is to be done in 'A' Vehicle garage. |
| 53 | S&F unplasticized PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc of size 25 mm for 'A' veh garage concealed conduit etc complete all as specified and directed. |
| 54 | All as per item No 53 above, but for one 3/5 pin socket outlet 5 Amp on independent board complete all as specified and as directed. |
| 55 | All as per item No 53 above, but for one 3/5 pin socket outlet 5 Amp on the same board with other switches complete all as specified and as directed. |
| 56 | All as per serial item No 53 here-in-before , but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor ( Multi-stranded) PVC insulated and unsheathing electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 2.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and as directed. |
| 57 | S&F in replacement for Modular switch 1 way 6A, 1 module complete all as specified and directed. |
| 58 | S&F in replacement for Modular switch 1 way 16A, 1 module type complete all as specified and directed. |
| 59 | S&F in replacement for Modular Socket, 6A - 5 pin, 2 module type complete all as specified and directed. |
| 60 | S&F in replacement for Modular Socket 6A/16A - 2/3 pin, 2 module type complete all as specified and directed. |
| 61 | S&F in replacement of existing unsv FTL with 20 watt Emergency Inverter Batten/Reserve Plus 4 feet Rechargeable Inverter Batten Cool day Light complete all as specified including necessary fitting on wall and making electric connection from ceiling rose to connector with suitable size of electric cable and making good the disturbed surface complete all as specified and directed. |
| 62 | S&F in replacement of suspended type LED light suitable for 'A' veh garage suspended type with PDC Housing, elliptical shaped LED Highway luminaire with PC Diffuser 100 watt Equipped with 4kv inbuilt surge protection, IP-65 Protection rating, 230 volts including cost of GI wire suitable hanging the fitting upto 2 mtr down from truss structure complete all as specified and directed. |
| 63 | S&F new generation energy saving and environmental friendly long life LED building security light 70 watt IP-65, made up of pressure die cast aluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07, with all accessories including suitable bracket with suitable dia light grade GI pipe bend to shape, including MS clamp of size of required size complete all as specified and directed. |
| 64 | M&L for Fan step regulator, 120W - 1 module complete all as specified and directed. |
| 65 | S&F Energy saving ceiling fans complete with blades, down rod and with all accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM not less than three star rated with brushless direct current motor (BLDC)as complete all as specified and directed. Note:-Unsv C/Fan will be deposted to MES office. |
| 66 | S&F in replacement for modular ceiling rose surface type, 65 mm x 50 mm two to three terminals / PVC / polycarbonate, isolated body fixed on PVC block complete all specified and as directed. |
| 67 | S&F in replacement of existing Unsv Sheet metal enclosure with new DB’s suitable for MCBs of single pole and neutral 12 way double door type as per IP-54 protection with 200 amp rated bus bar complete all as specified and directed. Note: i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. ii) The disturbed surface shall be match with existing shall be part of job. |
| 68 | S&F in replacement of MCB SP up to 6-32 Amp complete all as specified and directed. |
| 69 | S&F in replacement of MCB SPN 32 Amp complete all as specified and directed. |
| 70 | Supply & lay in replacement of existing Unsv XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volt grade of cross-sectional area 16 Sqmm 2 Core complete all as specified & directed. |
| 71 | Supply of dry fine aggregate (sand) for underground cable laying in tranches completed all as specified and directed. Please Enable Macros to View BoQ information |