| 1 | Microprocessor based Intelligent Addressable Main Fire Alarm Control Panel should be compatable for CPU redundancy with suitable Loops modules and each loop capable of supporting not less than 240 devices (detectors & modules should be in any combination) ; Loop length up to 1.0 km, 7\\" graphical screen display with bright colors to indicate alarms and events, 4 Nos of Integrated Ethernet Ports & 2 Nos of RS 485 for networking, 20 programmable zonal LEDs with slide-in labels, and 25 system LEDs for information purposes with 4 programmable function buttons with LED indication for confirmation of operation. The Panel shall support 10000 history logs in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have provision for seamless integration with EVAC certified Public Address System and shall be complete with all accessories. Shall have EN54, VDS / UL, FM / LPCB Certification. |
| 2 | 1 Loop Panel expandable upto 2 loops |
| 3 | Wireless Intelligent Photoelectric (Dual Optical) smoke detector with mounting based LED as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m |
| 4 | Addressable multisensor smoke detector including mounting base with LED complete as required with 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements; Drift Compensation feature & Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values. Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall have EN54-VDS/UL-FM certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) |
| 5 | Wireless Addressable analogue type Heat Detectors with combination of fixed type and rate of rise of temperature feature. Detetctor should have inbuilt isolators as per NFPA 72 style 7 wiring requirements and have an option of both soft & hard addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall have EN54-VDS/UL-FM certification.(Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) |
| 6 | Wireless Addessable Manual call point unit with inbuilt isolators as per NFPA 72 style 7 wiring requirements, with flexible network structures & necessary fixing arrangements with key complete as required. Shall have EN 54-VDS/UL-FM Certification. |
| 7 | Addessable Manual call point unit with inbuilt isolators as per NFPA 72 style 7 wiring requirements, with flexible network structures & necessary fixing arrangements with key complete as required. Shall have EN 54-VDS/UL-FM Certification. |
| 8 | Loop Powered Sounder with inbuilt isolators as per NFPA 72 style 7 wiring requirements & with 32 different tone variants selection options & adjustable sound pressure by 5 levels, the sound pressure 92.1 dB(A), should be programmed from the panel. Shall have EN54-VDS/UL-FM Certification. |
| 9 | Loop Powered Strobe with inbuilt isolators as per NFPA 72 style 7 wiring requirements,with flasher having Synchronized flash rate of 1 Hz and Light intensity > 2 cd, should be programmed from the panel. Shall have EN54-VDS/UL-FM Certification |
| 10 | Translator module for transmission of signal from Wireless detectors with dual channel redundancy and capacity of handling atleast 120 devices |
| 11 | Expander module for boosting the signal strength for communication with wireless devices |
| 12 | 2C 1.5 sq mm armoured FRLS Fire Retardant cables in celing with suitable clamps and screws (RED colour) |
| 13 | 25mm dia PVC conduit for laying of fire cable including necessary accessories like bend, junction box fixing of clamps etc., complete. The conduit shall be recessed in wall including chipping, roup plastering etc. Please Enable Macros to View BoQ information |