|
| 1 | Providing, laying, jointing and testing in following sizes of MS Class 'C' (heavy class) pipes Conforming to IS: 1239/3589 with accessories like fittings including tees, elbows, reducers, flanges gaskets, G.I. nuts, blots complete with all accessories as required. Make-TATA/JINDAL/SAIL/ZENITH BIRLA |
| 2 | 25 mm |
| 3 | 50 mm |
| 4 | 80 mm |
| 5 | 100 mm |
| 6 | Providing, fixing, testing and commissioning of MS air cushion tank on top of each riser fabricated form 6mm thick MS plate, 250 mm in diameter and 1.2 m in height with dished ends fabricated from 8mm thick MS plate with Air release valve with stop cock, flanged inlet connection and drain arrangement with 25mm dia valve, pressure gauge with gun metal stop cock complete with all accessories as required. |
| 7 | Proviidng ,Installing and commissioning of Frist Aid hose reel with MS Construstion spray painted in post office red (swinging type hose reel drum) Conforming tp IS 884 with upto date amendments complete with 30 mtr long and 20 mm nominal internal dia heavy duty r water hose thermoplastic (Teitile reinforced )type II, 20 mm dia globe valve stop cock. Tetrminating with G.M. coupling & nozzle of 6mm outlet with shut off valve complete as required. Make:-Make. Tyco/Ceasefire/ Omex/Newage/Attackfire |
| 8 | Providing Gunmetal Collecting head with 63 mm dia instantaneous type inlet +100 mm dia flanged outlet with built incheck valve for fire brigade connection to UG Tank +wet riser I.S 904 specification test for 20kg/mm2 including necessary support complete in all respect. Make. Tyco/ Ceasefire/Omex/ Newage/Attackfire |
| 9 | Two Way |
| 10 | Providing Cast iron /steel Butterfly Valve Confirming to type P.N 1.6 of I.S 13095-1991 Complete with Flanges bolt ,nuts ,gasket etc. As per table 'E' specification complete in all respect hydraulically test to 20 K./sqcm. Make. Zoloto/ Sant/Leader/Kirloskar. |
| 11 | 100 mm Dia. |
| 12 | Providing and fixing Cast Cast Iron double flanged Cast Iron dual Plate (Wafer type ) NRV valve, PN 16. confirming to class - I of Art No.1082 including nuts, bolts, 1.5 mm thick compressed asbestos gasket as per table \\"E\\" and specifications complete in all respect. Make. Zoloto/ Sant/Leader/Kirloskar. |
| 13 | 100 mm dia. |
| 14 | SITC Pressure switch for Main, Jockey, and staind by Diesel pumps including necessary wiring up to control panel and Ballvalve. complete in all respect. Make:-Denfoss/Indfos/ Delta control. |
| 15 | Supply, Installing, testing and commissioning of 100mm dial type pressure gauge gate valve with all accessories as requried.Make. H.Guru/Emerald/Warree/Fbig |
| 16 | Supply, Installing, testing and commissioning of 25mm dia gate valve with all accessories as requried. Make. Sant/ Zolto/ Leader/Kirloskar |
| 17 | SITC of Terrace Pumpset Kirloskar Make pump in back pull out design (end suction type ) having 100 mm suction, 100 mm delivery, protection,CI casing , CI impeller and CS shaft with gland packing arrangement coupled on common baseplate kirloskar/ABB/CEL Make 9.3 KW/12.5HP, 2900RPM TEFC sq.cage induction motor suitable for 3 phase,415V,50Hz Ac Supply confirmimg to through suitable flexible coupling ,Total Head 35mtr, 900 LPM, F- class insulation IP 55, including carriage of materials, labour, tool and plant through all modes of transportation within all leads and lifts with five year warranty and as per direction of Engineer-in- Charge. |
| 18 | SITC of Cubical type panel fabricated from 2mm thick CRCA sheet wall mountedtype made 1.8SWG IP 42 compartmentalised withhinged locable doors, dust and vermin proof.powder coated of approved shade after 7 tank treatment process,cable alley,inter connection,Incomer 63 amp . TP MCB with voltmeter.Ampere Meterinbuilt 72 mm meter, Outgoing 12.5 HP DOL Starter and auto/Manual switch with R/Y/B Three phase indication pump running staus indication push buttion start and stop etc. and internal wiring,earth terminal nimbering,suitable 4 wire 415V ac 50 Hz 12.5HP 9.3 KW Dol Starter control wire FR copper conductor etc complete in all respect |
| 19 | Providing and fixing of 4 Kg. ABC MAP-50% Powder type fire extinguishers are manufactured and marked to Indian standard IS: 15683. Hose shall made of EPDM Rubber, CE Marked Valve, Suitable first aid appliance for fighting fires in Class A, B & C fire that is wood, textile, flammable liquids & gases.Make. Tyco/ Ceasefire/Omex/ Newage/ Attackfire |
| 20 | Providing & fixing of CO2 gas 4.5 kg ISI marked (IS:15683) portable fire extinguisher, carbondioxide type flat base including valve, discharge hose of not less than 10 mm dia. 1 M long & complete in all respects including initial fill confirming to IS:15222 filled to a filling ratio of not more than 0.667 and wall suspension bracket. Make. Tyco/ Ceasefire/Omex/Newage/Attackfire |
| 21 | Providing and fixing Water CO2 9 .Litrs type fire extingushers consisting of seamless cylindrical body, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube, 30cms long high pressure discharge hoase, discharge nozzle, suspension bracket, confirming to IS: 15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. Make. Tyco/ Ceasefire/Omex/Newage/Attackfire |
| 22 | Supplying and Laying of 4 core 6 sq mm multistranded copper conuctor, FRLS PVC insulated and FRLS PVC Sheathed cable as required. Make : - Polycab/Finolex/ Plaza as approved by Er-In-Charge |
| 23 | Supplying and fixing of following sizes of PVC conduit Heavy duty ISI marked minimum thickness 2.0 mm along with accessories insurface/recess including painting in case of surface conduit, or cutting the walland making good the same in case of recessed conduit as required. Make:-Diplast/BEC/Polyfit/ PolyIndia/AKG as approved by Engineer-in -charge. |
| 24 | 25 mm. dia |
| 25 | Supplying and fixing true power make advanced earthing system having GI pipe 3 meter long 50 mm dia with terminal size 50x6 mm ,internal strip size 25x3 with 50 Kg compound including exvation of pit and refiling the same and making earthing pit cover 12 inch dia as required complete in all respect. Make :- True power / Earth plus/ Ashloka as per best satisfaction of Engineer-in -charge. |
| 26 | Providing and fixing 6 SWG G.I. wire on surface or in recess for loop earthing as required. |
| 27 | SITC of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class – 1 material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour & material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work Make PES/Giolite/OMEX |
| 28 | Supplying and Fixing Sign plate with inscription building sign with paint as desired size 300mm X 200 mm made of mild steel ,at least 2 mm thick with suitable hanging chain as required, complete in all respect. |
| 29 | Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required. Make:- Legrand(Myrius), L&T(entice) , Anchor (Roma classic ) as approved by Engineer-in -charge . |
| 30 | Supplying and drawing following size of FRLS PVC insulated copper conductor single core cable in existing surface / recessed, Steel/medium class PVC conduit as required. Make:- Plaza/ Finolex/ Anchor/ Polycab as approved by Engineer-In-Charge |
| 31 | 3x1.5 Sq. mm. |
| 32 | The contractor shall warranty for five years, the complete system to provide the specified flow and pressure under all condition at outlet All the equipment shall be guranteed for a period of five years form the date of acceptance and taking over of the installation by the department, against unsatisafactory performs and /or break down due to defective design,material ,manufacture, workmanship or installation. The equipment and components,or any part thereof , so found defective during gurantee period shall be forthwith repaired or replaced within 24 hour to the satisafaction of the engineer-in-charge. Please Enable Macros to View BoQ information |