| 1 | Material, labour (Technician & Helper) and T&P including testing eqpts for carring outs comprehensive maintenance and testing of earthing any type as per existing procedure for lighting protection /eqpts/domestic etc in tech area & adm area of 24 ED AF Manauri by tightening of nut bolts arranging earth lead in allighnment manner replacing unservicable earthing lead ,funnel ,pit cover and PCC pits,removing the shrubs etc (which will be paid as supply only) and testing of earthing will be done in presence of user and signed and record the result in register (as per procedure provided as directed ,If result found more than permissible limit reconditioning of earthing carried out by pouring water with salt /chemical as per direction and further testing the same earthing and result should be satisfactory and record in register incl levelling refilling of earth settle down near pit.Note-(i) Necessary compound required for recharging shall be measured and paid separately under item No 2 here-in-after.(ii) During contract ,Payment for each job shall be made once only during currency of contract irrespective of attending/testing / replacing defective parts at any time that will be paid supply only under respective item if not paid earlier.and minor spare parts like nut bolt ,washers etc and brazing,necessary earth work is included in rate quoted.(iii) Pouring of salt/chemical/charcoal water in the earth pit is included in the rate quoted.(iv) Approx 100 nos of earthing to be checked in amonth and Earth test record register to be put up to EIC Fortnightly. |
| 2 | Supply only carbon based low resistivity compound Bentonite powder solution(advanced erath filling compound) complete all as specified and directed by Engr-in-charge. |
| 3 | Supply only copper strip 20 mm x 3.15 mm complete with saddles and fixing screws for fitting the strip for earth continuty conductor up to test points. |
| 4 | Supply only Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25m long hex. head screw including connecting with earthing strip complete all as specified and directed. |
| 5 | Supply only GI earthing wire of size 4mm dia galvanised iron or steel wire including nesassary brazing and connecting with existing earthing system complete all as specified and directed. |
| 6 | Supply only Galvanised iron tubing,15 mm bore, light grade with all fittings for laying of Earth wire or for watering pipe including all fixing accessories complete. |
| 7 | Supply only PGI funnel with wire mesh of size 15 mm all as specified and directed. |
| 8 | Supply only charcoal dust powder of superior quality all as spcified and directed. |
| 9 | Supply only common salt of superior quality all as spcified and directed. |
| 10 | Supply only chemical to burn out the shrub/grass /unwanted small trees etc in outfit area of near building earth pit Note -chemical shall be supplied in sealed container of 2 to 5 ltr each after approval of EIC |
| 11 | Material & labour for Chemical earthing complete with copper plate electrode 900mm x 600mm x5mm burried directly in ground vetically to a depth not less than 4.70 mtr below normal ground level (with top edge of earth plate not less than 3.60 mtrs below ground level ) connected to copper strip 32 mm x 6 mm as main earthing lead by means of brass brazing at all joints all as directed and connected to earth test point including galvenizing isolation for equipments to put E-N voltage within limit all as specified and testing on completion with and including necessary excavation and earth work in any type of soil ,GI pipe medium grade 50 mm bore for protection of copper strip from earth electrode to earth test point of galvanised Iron / steel , adequate quality of charcoal dust, common salt and magnesium sulphate in alternate layers of 100 mm thick x 6 layers all around the plate ,including Earthing pit marker/ identifier of Iron plate of size 300mm X 200mm X 3mm and alongwith 1 meter long medium grade GI pipe of size 15 mm dia weilded with steel plate including painting with applying one coat of red oxide and two coat of painting with synthetic enameled paint of approved quality including writing letters as specified by EIC complete and providing FRP Earthing pit chamber with cover designed for high loading capacity ,weather proof,rustproof,damper proof ,environment friendly,long use life of size 12 inches in square shape , PGI funnel with wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate no 3 of SSR Part no 1 of 2009 complete incl taking out old unsv earthing all as spcifed and directed.Note- Earthing value should be less than 1 ohm otherwise contractor have to do it again at own expence. |
| 12 | M& L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cmx6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I including and connecting to earthing test point block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw and testing on completion with and including 15 mm bore light grade G.I. protection pipe (upto 7.5 M beyond outer edge of earth pit) providing FRP Earthing pit chamber with cover designed for high loading capacity ,weather proof,rustproof,damper proof ,environment friendly,long use life of size 12 inches in square shape , PGI funnel with wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate no 3 of SSR Part no 1 of 2009 complete all as spcifed and directed. including Earthing pit marker/ identifier of Iron plate of size 300mm X 200mm X 3mm and alongwith 1 meter long medium grade GI pipe of size 15 mm dia weilded with steel plate including painting with applying one coat of red oxide and two coat of painting with synthetic enameled paint of approved quality including writing letters as specified ny EIC complete including testing on completion complete incl taking out old unsv earthing all as specified and directed. |
| 13 | Same all as item no. 12 above here in before but connected to galvanised earth strip 32x6 mm as earthing lead complete all as specified and directed. |
| 14 | Same all as item No. 12 but using copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead complete all as specified and directed. |
| 15 | Dismantling and taking down worn out and / broken air termination rod and supply and fixing new air termination,single pointed aluminium rod 12mm dia and 300mm long connecting with existing lightening conductor system complete all as soecified and directed. |
| 16 | All as per item No. 15 above but with copper rod |
| 17 | Excavation in trenches not exc. 1.5 mtr wide and not exc. 1.5 mtr in depth for foundation , shaft well, cesspit, manholes, pier hole etc and not exc 10 sqm on plan and getting out in soft / loose soil complete all as specified & directed. |
| 18 | Returning, filling in, including, spreading, leveling, watering & well ramming in layers not exceeding 25 CM complete all as specified & directed. |
| 19 | Removing excavated material (soil) to a distance not exceeding 50 mtr and deposited where directed all as specified |
| 20 | M&L for earth continuity conductor galvanised iron strip 32mm x 6mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipeor fixed to pole or any other indicated situation for loop earthing complete all as specified incl taking down old unsv earth continuity conductor complete all as specified. |
| 21 | M&L for earth continuity conductor aluminium strip 25 x 3.15 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipeor fixed to pole or any other indicated situation for loop earthing complete all as specified incl taking down old unsv earth continuity conductor. |
| 22 | Supplying and laying in repair High density poly ethylene pipes(HDPE) PN10 ,50 mm bore of pressure rating 6 kgf/cm2 laid in trenches or fixed to walls, ceilings or in floors for protection of earth continuity conductor complete all as specified and directed by EIC. |
| 23 | S&f in replacement PVC flexible conduit 32 mm dia on wall /top of roof/ roof sheet for providing isolation to aluminium strip from wall/metal sheet on roof complete all as specified and directed. |
| 24 | M&L in replacement fabrication,installation sign board identifier/marker (30X20 cm board preferably mettalic in oval shape of 22 SWG stand made out of angle iron of size 40x40x6 mm thick of lenth 90 cm (60 cm above GL) and duly painted with two coat of synthetic enamel paint of red/yellow color for background over a coat of red oxide primer and marked 'LA' or 'EQ' letter of size 2 inch height in black paint and text mention on marker like type of earthing,no of earth pit etc all as directed and to be grouted incl excavation and earth work.Note- color code and text or sign on sign board will be decided by EIC as per Earthing derectives |
| 25 | M & L in repair for pit marker/indicator of size 300x200x3 mm with alongwith 1 meter long medium grade GI pipe of size 15 mm dia weilded with steel plate including painting with applying one coat of rad oxide and two coat of painting with synthetic enameled paint of approved quality including writing letters, in different colors as per directive .Shape and size of letter as per directed by EIC. |
| 26 | Taking down old unserviceable GI pipe any size all as specified and directed. |
| 27 | Supply and fixing of 20 mm bore GI pipe medium grade ISI marked as per IS:1239 with all new GI fittings, laid in trenches/wall complete all as specified and as directed. |
| 28 | Supply and fixing of 15 mm bore GI pipe medium grade ISI marked as per IS:1239 with all new GI fittings, laid in trenches/wall complete all as specified and as directed. |
| 29 | M&L for laying of single run of single core PVC insulated unsheathed multi stranded copper conductor cable of size 10 Sqmm 1100 volts grade as earth continuity conductor drawn through in rigid non metallic PVC conduit of suitable size on roof/wall/ceiling including making good the disturbed surfaces of wall etc including taking out old unserviceable burnt/damaged wire from its existing position complete all as directed by Engr-in-Charge (Note : Non metallic PVC conduit rate included in the rate quoted). |
| 30 | M& L for in repair Earthing pit of PCC pit 1:3:6 type C1 using 20 mm bore grade stone aggregrate ,40 mm thick precast RCC cover 1:2:4 type B1 using 20 mm graded stone aggregrate reinforced with 8 mm dia TMT bars 3 nos both ways with 12 mm dia round handle all as shown in electrical plate no 3 of MES SSR pt I complete all as specified and directed |
| 31 | S&F in replacement FRP Earthing pit chamber with cover designed for high loading capacity ,weather proof,rustproof,damper proof ,environment friendly,long use life of size 12 inches in square shape of complete all as specified and directed. Please Enable Macros to View BoQ information |
| 32 | S&F in replacement FRP Earthing pit chamber with cover designed for high loading capacity ,weather proof,rustproof,damper proof ,environment friendly,long use life of size 12 inches in square shape of complete all as specified and directed. Please Enable Macros to View BoQ information |