| 1 | BOUNDARY WALL WORK -35 M |
| 2 | Earth work in excavation by mechanical means(Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 3 | 1:5:10 (1 Cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 5 | 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 6 | 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 7 | 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 8 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 9 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) :With F.P.S.(non modular) bricks |
| 10 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existingT-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge ( door work) |
| 11 | 12 mm thick Plaster of mix 1:4 cement coarse sand …complete item. |
| 12 | Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 13 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 14 | Finishing walls with water proofing cement paint of required shade New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 15 | Fixing of Main gate including Sliding rail etc |
| 16 | (CONSTRUCTION OF HALL (9 m x 4.5 m) WITH VERANDAH ( 2 m WIDE) |
| 17 | Earth work in excavation by mechanical means(Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 18 | 1:5:10 (1 Cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 19 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 20 | Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 21 | Earth work in cutting or in embankment in ordinary soil excavated to be in the form of regular pits not exceeding 0.50m in depth and earth work in embankment to be in 20cm layers including ramming and dressing the surface to required levels and slopes and also including 1.50m lift and 30 m lead.(With 8.00KM cartage) |
| 22 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 23 | 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 24 | 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 25 | 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 26 | 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 27 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 28 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) With F.P.S.(non modular) bricks |
| 29 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existingT-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge ( door work) |
| 30 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) Window |
| 31 | 12 mm thick Plaster of mix 1:4 cement fine sand in ceiling …complete item. |
| 32 | 12 mm thick Plaster in 1:6 cement fine sand in inner side …complete item. |
| 33 | 12 mm thick Plaster in 1:6 cement sand in outer side …complete item. |
| 34 | Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with water proofing compound common burnt clay non modular bricks:1:4 (1 cement : 4 coarse sand( Brick Coba) ... comp. item |
| 35 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 36 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete |
| 37 | Chequered precast cement concrete tiles 20 mm thick in footpath and courtyard jointed with neat cement slurry mixed with pigment match the shade of Tiles including rubbering and cleaning etc .. Complete on 20 mm thick bed of cement mortar1:4 cement coarse sand. DSR- 11.20.1 |
| 38 | 20 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) |
| 39 | Making grooves 10 to 12mm wide X 8 mm deep in plaster of the walls or in ceiling vertically or horizontally as required . |
| 40 | Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B), fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer- in-charge and panelling with panels of :(Note:- Butt hinges and necessary screws shall be paid separately) 12 mm thick plain grade -1, medium density flat pressed three layer particle board FPT - I or graded wood particle board FPT- I, IS : 3087 marked, bonded with BWP type synthetic resin adhesive as per IS : 848 : |
| 41 | Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 42 | Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 43 | Apply priming coats with primer of approved brand manufacture having low VOC (Volatile Organic Compund ) with ready mixed pink or gray prime on wall surface having VOC Content less than 50 grams/litre |
| 44 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 45 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10sqm of approved brand and manufacture |
| 46 | Finishing walls with water proofing cement paint of required shade New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 47 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including waterthinnable priming coat with cement primer |
| 48 | P/Fixing of 100mm PVC RWP down pipe with clamping and bend shoes etc …. Complete. ( S.I-730a,miscellaneous ) |
| 49 | Providing & fixing stainless steel sliding bolts ISI marked/brand make in required colour or shade with necessary nuts and screws etc.complete. |
| 50 | Providing and fixing bright finished brass handles with screws etc.complete: 125 mm |
| 51 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete 250x10 mm |
| 52 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete |
| 53 | Supply and fixing of Sign Board |
| 54 | Cartage of material |
| 55 | Mosquito mesh ss …complete |
| 56 | NAME OF WORK - CONSTRUCTION OF TOILET |
| 57 | Earth work in excavation by mechanical means(Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 58 | 1:5:10 (1 Cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 59 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1%concentration |
| 60 | Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 61 | Earth work in cutting or in embankment in ordinary soil excavated to be in the form of regular pits not exceeding 0.50m in depth and earth work in embankment to be in 20cm layers including ramming and dressing the surface to required levels and slopes and also including 1.50m lift and 30 m lead.(With 8.00KM cartage) |
| 62 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 63 | 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 64 | 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 65 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 66 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) :With F.P.S.(non modular) bricks |
| 67 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 68 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existingT-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge ( door work) |
| 69 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) Window |
| 70 | Fixing of door in proper position |
| 71 | 12 mm thick Plaster of mix 1:4 cement fine sand in ceiling …complete item. |
| 72 | 12 mm thick Plaster in 1:6 cement sand in inner side …complete item. |
| 73 | 12 mm thick Plaster in 1:6 cement fine sand in outer side …complete item. |
| 74 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 75 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 76 | 20 mm thick cement plaster in 1:4 cement coarse sand finished with neat cement in dado/skirting … complete item. |
| 77 | Providing and fixing ISI marked flushed door shutter confirming to IS:2202 (Part 1 ) non decorative type core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply venneering with vertical grains of cross bands and face veneerw on both faces of shutter. |
| 78 | Providing and fixing glass panes with putty and glazing clips in steel doors window ,clerestory windows all complete with 4mm thick … complete item SL.N-9.04 N.I |
| 79 | Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 80 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 81 | Painting on new wood work in two coat with one coat priming with approved superior quality ready mix synthetic enamel paint including supply of all material and labour etc. required for proper completion of work. |
| 82 | Finishing of wall with two coat of water proof cement paint on a white cement primer coat of approved make and quality …complete |
| 83 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including waterthinnable priming coat with cement primer |
| 84 | P/Fixing of 100mm PVC RWP down pipe with clamping and bend shoes etc …. Complete |
| 85 | P/Fixing of 80 mm PVC down pipe with clamping and bend shoes etc …. Complete. |
| 86 | Making soak-pit 2.5 m. diameter and 3 m. deep with 45 x 45cm dry brick honey comb shaft with F.P.S bricks and SW drain pipe complete as per standard design. |
| 87 | Providing & fixing stainless steel sliding bolts ISI marked/brand make in required colour or shade with necessary nuts and screws etc.complete. |
| 88 | Providing and fixing bright finished brass handles with screws etc.complete: 125 mm |
| 89 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete 250x10 mm |
| 90 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 91 | Providing and fixing White Vitreous China pedestal type Water closet ( Europen type W.C Pan ) with seat and lid , 10 litre low level white PVC flushing Cistern including flush pipe with manually controlled device (Handle lever ) confirming to IS 7231 with all fittingd fixtures ... complete including cutting and making the good the walls and floors wherever required. |
| 92 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps. |
| 93 | Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete. 32mm dia |
| 94 | S/F of 15 mm tap |
| 95 | S/F of 15 mm CPVC pipe |
| 96 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 97 | Cartage of material |
| 98 | Construction of Manhole chamber with common burnt clay fps (non modular ) bricks of class designation 7.5 with cover |
| 99 | 1.5 HP Submercible Pump |
| 100 | Supply of 1.5 HP Submercible Pump ISI Marked or approved quality as texmo crompton etc. required for 4'' boring…....complete item Market Rate |
| 101 | Suplly of starter with panel Board |
| 102 | 100 mm PVC pipe 6kg/sqcm pressure(sch water supply item no DSR 23.4.1) |
| 103 | Supply of medium class G.I. Pipe 32 mm B class DSR 18.12.4 |
| 104 | Providing necessary boring ,T&P including making arrangement of water for boring of 150mm Dia by palm pressure method in all type of strata….complete item |
| 105 | 0-15 M |
| 106 | 15-30 M |
| 107 | 30-40 M |
| 108 | 45-70 M |
| 109 | Supply of 4mm cabel .(M.R) |
| 110 | Supply of suporting wire.(M.R) |
| 111 | Supply of pea gravel.DSR7772 |
| 112 | Supply of Bentonite Powder.(M.R) |
| 113 | Water arrangement for boring DSR0046 |
| 114 | Lowering of 110mm PVC Pipe. (M.R) |
| 115 | Lowering of 32mm G.I Pipe. (M.R) |
| 116 | Generator for cleaning of boring.(M.R) |
| 117 | ELECTRIC WORK |
| 118 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 119 | Same as item No.-1 but for fan and light duty exhaust fan |
| 120 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required |
| 121 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2x2.5sq.mm +1x2.5sq.mmearth wire |
| 122 | Supply and fixing of flush / surface mounting distribution boards complete in all respects. 8 Way SPN ,CAT-A |
| 123 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 124 | Supply & fixing of two number 8 SWG G.I Wire in 15 mm dia G.I pipe for earthing purpose as required complete in all respects. |
| 125 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected wiyh burnt bricks on sides and on top.On surface the cable run shall be fixed on M.S clamps etc. of suitable size or as directed by the engineer in charge,complete in all respect .The armouring of the cable shall be properly connected with the earth conductor by clamps etc. (b) 10 sq mm 2 core |
| 126 | Supply and fixing of LED tube light with batten suitable for up to 1X22 watt. LED tube light fitting including tube on surface complete in all respect. Cat AAA |
| 127 | Erection and testing of ceiling fan regulator etc excluding supply of ceiling fan regulator etc. Excluding supply of down rod,complete in all respect. |
| 128 | Supplying and fixing following size/ modules, Gl box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 module |
| 129 | Supply and erection of overhead line with GI wire no. 8 to 4 SWG on poles / service bracket including binding etc. Complete in all respect. |
| 130 | wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit as required .2x2.5 sq .mm + 1x2.25sq mm earth wire |
| 131 | Add for Invertor wiring in wiring point for light/fan/plug with 1.5 mm Cu wire |
| 132 | Supply and fixing of power plug with 15 Amp/250 volt flush type switch and 5 pin 15 A/250 V type universal socket in suitable M.S box of 175X100mm X 50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer |
| 133 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required. |
| 134 | Supply and fixing of LED bulb 12 watt |
| 135 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Please Enable Macros to View BoQ information |