| 1 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. |
| 2 | Providing and laying 6 to 8 mm thick ivory or light shade vitrified tiles of 600 x 600 mm size with all colours and shades, laid on 20mm thick cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. |
| 3 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 25 mm thick |
| 4 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 5 | 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand |
| 6 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. |
| 7 | 12mm thick plaster in 1:3 on ceiling and soffits of stairs upto floor two level. |
| 8 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brickbats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5(1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm heightincluding rounding of junctions of walls and slabs c) After two days ofproper curing applying a second coat of cement slurry using 2.75 kg/ sqmof cement admixed jointless cement mortar of mix 1:4 (1 cement :4 coarsesand) admixed with water proofing compound conforming to IS : 2645and approved by Engineer-in-charge including laying glass fibre cloth ofapproved quality in top layer of plaster and finally finishing the surface withtrowel with neat cement slurry and making pattern of 300x300 mm square3 mm deep. e) The whole terrace so finished shall be flooded with water fora minimum period of two weeks for curing and for final test. All above |
| 9 | Dismantling jack arched or wooden beam & barges roof.including beam and roof concrete and including stacking of materials as directed byby the Engineer-in-charges with in a distance of 60 meters(200ft.) |
| 10 | Dismantling of existing plaster including disposal of refuse as directed by the engineer in charge |
| 11 | Dismantling cement concrete or brick or granolithic floors including base concrete and including stacking of dismantled materials as directed by the Engineer-in-charge within a distance of 60 metre (200 feet). |
| 12 | Disposal of Malba upto 8 Km |
| 13 | DOOR WINDOW REPAIR |
| 14 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : |
| 15 | 35 mm thick Single leaf |
| 16 | 35 mm thick Double leaf |
| 17 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. |
| 18 | Providing & fixing of door / windows grill. |
| 19 | Z-Section steel windows with Openable panels, excluding Glass panes. |
| 20 | Angle iron chaukhat (40x40x5) |
| 21 | Fixing of Door, windows / ventilators chaukhats in position. |
| 22 | (a) Door chaukhats |
| 23 | (b) Window chaukhats |
| 24 | (c) Ventilator chaukhats |
| 25 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 26 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868),transparent or dyed to required colour or shade, with nuts and screws etc. complete. (a) 250mm x 16mm. |
| 27 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 28 | 300 x 10mm |
| 29 | 200 x 10mm |
| 30 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete (a) 125 mm. |
| 31 | Dismantiling Door & window ,chowkhats with hold fast & including stacking of dismantled materials as directed by the engineer-in-charge with in a distance of 60 m (200ft) |
| 32 | (PAINTING WORK) |
| 33 | Steel Painting:Applying priming coat:(a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.(b) Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. |
| 34 | Steel Painting:Applying priming coat:(a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.(b) Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. |
| 35 | Finishing walls with Acrylic smooth exterior paint of required shade: - New work (Two or more coat applied @ 1.67 Ltr./10 Sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10 Sqm. |
| 36 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade . Two or more coats on new work (For Internal ceiling surface) |
| 37 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 38 | Scraping old white or colour wash including disposal of refuse as directed by the Engineer-in- charge with in a distance of 60 mts.(200 ft) |
| 39 | Toilet Work |
| 40 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. |
| 41 | Supply and fixing 6 mm China white glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials, labour and tool sand plants etc. required for proper completion of the work. (Size of tiles upto 300x300mm). |
| 42 | 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand |
| 43 | 12mm thick plaster in 1:3 on ceiling and soffits of stairs upto floor two level. |
| 44 | Dismantling of existing plaster including disposal of refuse as directed by the engineer in charge |
| 45 | Dismantling cement concrete or brick or granolithic floors including base concrete and including stacking of dismantled materials as directed by the Engineer-in-charge within a distance of 60 metre (200 feet). |
| 46 | Disposal of Malba upto 8 Km |
| 47 | TOILET BLOCK (WATER SUPPLY & SANITATION) |
| 48 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
| 49 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 50 | Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. |
| 51 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 52 | White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps |
| 53 | White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 54 | Providing and fixing soil, waste and vent pipes : Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 |
| 55 | 75 mm O.D. |
| 56 | 100 mm O.D. |
| 57 | Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes : |
| 58 | 75 mm O.D. |
| 59 | 110 mm O.D. |
| 60 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. |
| 61 | 75 mm size |
| 62 | 110 mm size |
| 63 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 64 | Shoe (Plain) |
| 65 | 75 mm Shoe |
| 66 | 110 mm Shoe |
| 67 | Providing and fixing plain bend of required degree. Sand cast iron S&S as per IS - 3989 |
| 68 | 75 mm size |
| 69 | 110 mm size |
| 70 | Providing and fixing heel rest sanitary bend Sand cast iron S&S as per IS - 3989 |
| 71 | 75 mm size |
| 72 | 110 mm size |
| 73 | Providing and fixing terminal guard : Sand cast iron S&S as per IS - 3989 |
| 74 | 75 mm |
| 75 | 100 mm |
| 76 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : |
| 77 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms. |
| 78 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall |
| 79 | 15 mm nominal outer dia pipes |
| 80 | 20 mm nominal outer dia pipes |
| 81 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 82 | Internal work - Exposed on wall |
| 83 | 20 mm nominal outer dia Pipes |
| 84 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. |
| 85 | 15 mm nominal outer dia pipes |
| 86 | 20 mm nominal outer dia pipes |
| 87 | Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends) |
| 88 | 25mm dia, nominal bore |
| 89 | 32 mm dia, nominal bore |
| 90 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
| 91 | 25 to 40 mm nominal bore |
| 92 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 93 | 45 cm length |
| 94 | 15 mm nominal bore |
| 95 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work (internal work -exposed on walls) |
| 96 | 15 mm nominal outer dia pipes |
| 97 | 20 mm nominal outer dia pipes |
| 98 | Providing and fixing G.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work) |
| 99 | 15mm nominal bore |
| 100 | 20mm nominal bore |
| 101 | Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931 |
| 102 | 15mm nominal bore |
| 103 | Providing and fixing C.P. brass long body bib cock of approved qualityconforming to IS standards and weighing not less than 690 gms. |
| 104 | 15mm nominal bore |
| 105 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore. |
| 106 | 15 mm nominal bore |
| 107 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 108 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including gettingout and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Char ge:All kinds of soil |
| 109 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 110 | Providing and laying in position cement concrete of specified grade including the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 111 | Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 112 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded |
| 113 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 114 | Foundations, footings, bases of columns, etc. for mass concrete |
| 115 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 116 | Brick Work with common burnt clay ( non modular) bricks of class - 150 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 117 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class - 150 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) |
| 118 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 119 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 120 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the coloumn pitswall tench basement excavation top surface if plinth filling junction of wall and floor along the external perimer of binding expansion joints,surrounding of pipes and conduits etc.complete(plinth area of the building at ground floor only shall be measured as per I.S.6313(Part ll 1981) aldrine emulsifiable concrete or any other approved material such as hepthachlor or chlordance will be used.The rate of application of chemical emulsion shall be as follows:-(1)treatment for masonary & foundation 5 litres per sq.m.(2)back fill in immediate contract with foundation 7.5 litre per sq.m(3)treatment of top surface of plinth filling 5 liters per sq.m.(4)treatment of soil along external parameter of building 7.50 lire per sqm. (For payment plinth area to be measured as per IS Code). |
| 121 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 122 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) |
| 123 | 12 mm cement plaster of mix: 1:6 (1 cement: 6 coarse sand) |
| 124 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) |
| 125 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 126 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 127 | Finishing walls with Putty approved brand and manufacture and of required shade on undacorated wall surface to give even shade over including curing and cost ofall material, labour, T&P etc. required for proper completion of work. |
| 128 | WATER SUPPLY & SANITATION |
| 129 | Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work. |
| 130 | 75 mm O.D. |
| 131 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 132 | 110 mm |
| 133 | Supply and fixing of UPVC S.W.R. Cowel confirming to IS- 14735 |
| 134 | 110 mm size |
| 135 | Supply and fixin g of UPVC S.W.R. Nahni trap size 100/75mm, 100/90mm confirming to IS - 14735 self cleannig design fixed in PCC 1:2:4 and supply and fixing of 125mm dia heavy duty CP brass jali. |
| 136 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall |
| 137 | 25 mm nominal outer dia pipes |
| 138 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. |
| 139 | 15 mm nominal outer dia pipes |
| 140 | Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends) |
| 141 | 25mm dia, nominal bore |
| 142 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
| 143 | 25 to 40 mm nominal bore |
| 144 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 145 | 45 cm length |
| 146 | 15 mm nominal bore |
| 147 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work (internal work -exposed on walls) |
| 148 | 25 mm nominal outer dia pipes |
| 149 | Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931 |
| 150 | 15mm nominal bore |
| 151 | Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming, watering etc. stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50m : |
| 152 | Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia. |
| 153 | Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work. |
| 154 | 160 mm O.D. |
| 155 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : |
| 156 | 150 mm diameter pipe |
| 157 | Supply and fixing of UPVC S.W. R. Gully trap confirming to IS - 14735 size 150x110 mm dia of self cleaning design including fixed brick Masonary chamber 250x250x250mm Size i/ c supply and fixing of CI cover with frame weight not less then 4.50Kg. & CI grating 150x150mm complete in all respects. |
| 158 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Fisnihed with a floating coat of neat cement complete as per standard design : |
| 159 | (a) Inside size 900 x 800mm and 500mm deep including C.I. Cover frame. |
| 160 | Extra over Item No. 24.27 for every additional depth of 0.10 metre or part there of main hole. |
| 161 | (a) Size 900 x 800 mm |
| 162 | (b) Size 1200 x 900mm |
| 163 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 164 | RO + WATER COOLER |
| 165 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil |
| 166 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 167 | Brick Work with common burnt clay ( non modular) bricks of class - 150 in foundation and plinth in: Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 168 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 169 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railingwith necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 170 | GST will be paid extra as per GST Notification Please Enable Macros to View BoQ information |