| 1 | Providing and laying Polished Granite stone flooring in required design andpatterns, in linear as well as curvilinear portions of the building all complete asper the architectural drawings with 18 mm thick stone slab over 20 mm (average)thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed withcement slurry and pointing with white cement slurry admixed with pigment ofmatching shade including rubbing , curing and polishing etc. all complete asspecified and as directed by the Engineer-in-Charge.Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red |
| 2 | Providing & fixing 12mm thick pre laminated flooring of approved brand as per direction of Engineer incharge complete job AC-4 including carriage classroom. |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m. All kinds of soil. |
| 4 | Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 gradedstone aggregate 40 mm nominal size derived from natural sources) |
| 5 | Dumping stone including cost of stones in Horizontal on level. |
| 6 | Reinforced cement concrete work in walls (any thickness), including attachedpilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 8 | Centering and shuttering including strutting, propping etc. and removal of formwork for : Foundations, footings, bases for columns |
| 9 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 10 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 11 | Suspended floors, roofs, landings, balconies and access platform |
| 12 | Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 13 | Random rubble masonry with hard stone in foundation and plinth includinglevelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 gradedstone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 14 | Providing & fixing upto floor five level precast cement concrete solid blocks includinghoisting and setting in position in cement mortar 1:3 (1cement:3 coarse sand), cost ofrequired centring, shuttering and curing complete1:3:6 (1 cement : 3 coarse sand : 6 graded crushed stone aggregate 20 mm nominalsize) |
| 15 | 15 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement: 4 fine sand) |
| 16 | Providing wood work in frames of doors, windows, clerestory windows and otherframes, wrought framed and fixed in position with hold fast lugs or with dashfasteners of required dia & length (hold fast lugs or dash fastener shall be paidfor separately).Second class Kail wood |
| 17 | Providing and fixing panelled or panelled and glazed shutters for doors, windowsand clerestory windows fixing with butt hinges of required size with necessaryscrews, excluding panelling which will be paid for separately, all complete as perdirection of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall bepaid separately) |
| 18 | Renewing glass panes, with putty and nails wherever necessary including rackingout the old putty:Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) |
| 19 | Dismantling of wooden flooring incl removal of plank and stacking / disposal of unserviceable material complete hall. |
| 20 | 25 mm wooden planking, tongued and grooved in flooring, including fixing withiron screws complete with :1st class teak wood |
| 21 | Cement concrete flooring 1:2:4 ( 1 Cement :2 coarse sand : 4 graded stone aggregate ) finished 50mm thick with 20mm nominal size aggregate stair. |
| 22 | Providing and fixing flat pressed 3 layer particle board medium density exteriorgrade (Grade I) or graded wood particle board IS : 3087 marked, to frame,backing or studding with screws etc. complete (Frames, backing or studding to bepaid separately): 18 mm thick |
| 23 | Providing and fixing flat pressed 3 layer particle board medium density exteriorgrade (Grade I) or graded wood particle board IS : 3087 marked, to frame,backing or studding with screws etc. complete (Frames, backing or studding to bepaid separately):12 mm thick |
| 24 | Providing & fixing 100mm pine wood plain linning , tongued and grooved incl wooden plug complete with necessary screw and priming coat on unexposed applied . |
| 25 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 26 | Providing and applying plaster of paris putty of 2 mm thickness over plasteredsurface to prepare the surface even and smooth complete. |
| 27 | Distempering with oil bound washable distemper of approved brand andmanufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coatwith cement primer |
| 28 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 withnecessary screws etc.complete :125 mm |
| 29 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts andscrews etc. complete : 250x16 mm |
| 30 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type)with necessary screws etc. complete : 250x10 mm |
| 31 | Painting with synthetic enamel paint of approved brand and manufacture to givean even shade : Two or more coats on new work |
| 32 | French spirit polishing : Two or more coats on new works including a coat of wood filler |
| 33 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.)trusses etc., including Hot finished welded type tubes |
| 34 | Providing and fixing precoated galvanised iron profile sheets (size, shape andpitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) totalcoated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpasteel grade, 5-7 microns epoxy primer on both side of the sheet and polyestertop coat 15-18 microns. Sheet should have protective guard film of 25 micronsminimum to avoid scratches during transportation and should be supplied insingle length upto 12 metre or as desired by Engineer-in-charge. The sheet shallbe fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDMseal, complete upto any pitch in horizontal/ vertical or curved surfaces, excludingthe cost of purlins, rafters and trusses and including cutting to size and shapewherever required. |
| 35 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes,channels, plates etc., |
| 36 | Carriage of material from source to site of work by M.T Cement + steel lead …........................4 km |
| 37 | Sand / Stone aggregate an avg lead …............8 km |
| 38 | Stone an avg lead ….........................10 km Please Enable Macros to View BoQ information |