|
| 1 | Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item-A)and disposal of excavated earth as obtained to a distance up to 50mts. Including all lift, levelling, ramming the foundation trenches, removing root of treese, shrubs all complete as per approved design, building specification and direction of E/I. |
| 2 | Providing coarse clean Sand filling in foundat. ion trenches or in plinth including ramming and waterind in layers not exceeding 150mm. Thick with all leads including cost of materials, labour, royalty and taxes all complete as per building specification and direction of E/I |
| 3 | Providing designation 75 B Brick flat soling joints with local sand including cost of water- ing taxes and royalty all complete as per building specification and direection of E/I |
| 4 | Providing P.C.C (M-150) (1:2:4) in foundation with approved quality of stone Metal of grade !!! (53mm.to 22.4mm.Size) clean coarse sand of F.M. 2.5 to 3.00 inculuding screening ,shuttering, mixing cement concrete in mixer and placing in position vibrating, striking, curing ,taxes and royalty all complete as per building specification and direction of E/I |
| 5 | Providing R.C.C. (M-200) (1:1.5:3) in Column with approved quality of stone Chips (20mm.to 6mm.Size) graded and clean coarse sand of F.M. 2.5 to 3.00 inculuding screening, shuttering,mixing cement concrete in mixer and placing in position vibrating, striking, curing,(but excluding the cost of reinforcement) taxes and royalty all complete as per buildingspecification and direction of E/I(Grade-A) |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 7 | Providing R.C.C. (M-200) (1:1.5:3) in Tie beams of & all types Beam, with approved quality of stone Chips (20mm.to 6mm.Size) graded andclean coarse sand of F.M. 2.5 to 3.00 inculuding screening,shuttering,mixing cement concrete in mixer and placing in position vibrating, striking,curing,(but excluding the cost of reinforcement) taxes and royalty all comp.as per building specification and directionof E/I. |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, Tie beams etc. for mass concrete |
| 9 | Providing designation 75 B Brick work in C.M.(1:6) in foundation and plinth with appro-ved quality of clean coarse sand of F.M. 2.00 to 2.5 including 10 mm thick mortar joints, cost of screening,scaffplding, raking out joints to 15 mm. depth, curing, taxes and royalty all complete as per building specification and direection of E/I(Grade-A) |
| 10 | Providing 50 mm. thik Damp Proof Coarse with cement concrete (M-150) (1:2:4) with approved quality of stone Chips (20mm.to 6mm.Size) graded and clean coarse sand of F.M. 2.5 to 3.00 inculuding screening, shuttering,mixing cement concrete in mixer with 5% cico or any other approved water proofing compound and placing in position striking,curing,taxes and royalty allcomplete as per bldg.specification and direction of E/I.(Grade-A) |
| 11 | Providing designation 75B Brick work in C.M.(1:6) in Super Structure with approved quality of clean coarse sand of F.M.2.00 to 2.5 including 10 mm thick mortar joints,cost of screening,scaffplding, raking out joints to 15 mm. depth, curing, taxes and royalty all compl-ete as per building specification and direection of E/I(Grade-A) |
| 12 | Providing R.C.C. (M-200) (1:1.5:3) in Lintel & band with approved quality of stone Chips (20 mm. to 6mm.Size) graded and clean coarse sand of F.M. 2.5 to 3.00 inculuding screening, shuttering,mixing cement concrete in mixer and placing in position vibrating, striking,curing,(but excluding the cost of rein forcement) taxes and royalty all complete as per building specification and direction of E/I. |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 14 | Providing R.C.C. (M-200) (1:1.5:3) in Chajja with approved quality of stone Chips (20mm.to 6mm. Size) graded and clean coarse sand of F.M. 2.5 to 3.00 inculuding screening,shuttering ,mixing cement concrete in mixer and placing in posit ion vibrating, striking, curing,(but exclud ing the cost of reinforce ment taxes and royalty all com plete as per building specification and direction of E/I. |
| 15 | Providing R.C.C. (M-200) (1:1.5:3) in Beams of all types, with approved quality of stone Chips (20mm.to 6mm.Size) graded andclean coarse sand of F.M. 2.5 to 3.00 inculuding screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, striking,curing,(but excluding the cost of reinforcement) taxes and royalty all comp.as per building specification and directionof E/I. |
| 16 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases |
| 18 | Providing R.C.C. (M-200) (1:1.5:3) in Solid Roof Slab with approved quality of stone Chips (20mm. to 6mm.Size) graded and clean coarse sand of F.M. 2.5 to 3.00 inculuding screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, striking,curing, (but excluding the cost of rein forcement) taxes and royalty all complete as per building specification and direction of E/I. |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 20 | Providing and fixing fan hook of 16mm dia. M.S.bar and 1m long,bend to required size and shape, placed in position and fixed in R.C.C. Beam/Slab at the time of casting all complete as per specification and direction of E/I |
| 21 | Providing 12mm water proof cement Plaster in cm (1:3) in top of roof with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I |
| 22 | Providing 6mm cement Plaster in cm (1:4) in Ceiling with clean coarse sand of F.M. 1.5 including cost of screening, curing with all leads and lifts of water,scaffolding,taxes and royalty all complete as per building specification and direction of E/I |
| 23 | Providing 12mm cement plaster in cm (1:6) in both side wall with clean coarse sand of F.M. 1.5 including cost of screening, curing with all leads and lifts of water,scaffolding,taxes and royalty all complete as per building specifica- tion and direction of E/I |
| 24 | Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm . |
| 25 | For StairProviding and laying vitrified floor tiles for step of stair in with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete step tiles & have bullnose, Anti and self embossed line. Size of Tile 1200x300 mmx15 mm |
| 26 | Providing 12mm thick cement paster in cm (1:4) with clean coarse sand &1.5mm cement punning including curing, carriage of waterwith all leads and lifts as per building specification and direction of E/I |
| 27 | Supplying fitting and fixing 20 gauge G.C.I. Sheet (Door & Window)gate on M.S.angle frame of size 60*60*6mm, including cost of fabrication providing necessary locking arrangements worth haskel and domny duly fixed in C.C. (1:2:4) blocks of required size, applying a prim ing red lead paint over steel work,taxes all com.as per specification and direction E/I. |
| 28 | Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction of E/I. |
| 29 | Supplying fitting and fixing M.S. grill of 20*6 mm M.S.flats as per approved deesign and drowing ,properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction E/I. |
| 30 | Provding two coats of Snowcem of approbved shade and make over a coat of cement primer on new surface including preparing the plasterd surface smooth with sand paper, scffolding, curing and taxes all complete as per building specification and direction of E/I. |
| 31 | Provding two coats of synthetic enamel paint over a primer coat of red lead paint of approved shade and make over new steels surface including preparing the new steel surface after cleaning,removing dircet scales,smokes, grese and cleaning the surface taxes and royalty all complete as per building specification and direction of E/I(Mode of mea surement-Area shall be multiplied by the co-efficient as indicated in building specifications) |
| 32 | providing two coats of dry distemper of approved shade and make over a primer coat of washing over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper ,applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction E/I. |
| 33 | Supplying fitting and fixing C.A.R.W.D. Pipe 75mm dia with necessary strips,spikes,bands,shoesetc including cost of carriage all complete as per building specification and direction E/I. |
| 34 | providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I.(a) 10mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL) |
| 35 | 12mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}) |
| 36 | Add Carriage Cost MaterialsBricks |
| 37 | Stone Chips |
| 38 | Cement and Steel |
| 39 | Dismantling Materials |
| 40 | Wiring for light/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FRPVC insulated copper conductor single core cable in surface/recessed conduit with piano type switch phenolic laminated sheet suitable size M.S. box and earthing the point with 1.5 sq.mm. FRPVC insulated copper conductor single core cable etc. as required.Group - A |
| 41 | S/F following piano type switch/socket on the existing switch box/cover including connection etc.as required. |
| 42 | S/F PVC/GI boxes Suppling and fixing of following sizes of PVC/GI box on sufrface recess with suttablle size of phenolic laminated sheet cover in fornt including painting etc as required.4''X4'' |
| 43 | 4''X7\\" |
| 44 | 4\\"X12\\" |
| 45 | 3 mm thick phentlic laminated sheet |
| 46 | Wiring for Curcuit submain wiring along with earth wire with the following sizes of PVC insulated copper conductor single core cable in surface of recessed PVC sonduit as required.2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire |
| 47 | 2 x 4.0 sq.mm + 1 x 4 sq.mm earth wire |
| 48 | 2 x 10 sq.mm + 1 x 6 sq.mm earth wire |
| 49 | S/F brass vatton/Angle Holder including connection etc. as required. |
| 50 | 9/10 watt LED bulb |
| 51 | 15/16 watt LED bulb |
| 52 | electronic step fan regulator |
| 53 | S/F 3 pin 5 amp ceiling rose on the existing junction box wooden block including connection etc. as required. |
| 54 | S/F the following way single pole and nutral sheet steel M.C.B. D.B. consumer unit 240V on surface/recess complete with tinned copper busbar, nutral busbar earth plate dinbar hinged front acrylic cover fro MCB knob datachable gland plate inter connection phosphatied and powder painted including earthing etc. as reuired (Without MCB/RCCB/Isolator).40 amps |
| 55 | Supply of 48\\" (1200mm) AC ceiling fan. |
| 56 | I.T.C of ceiling fan including wiring the down rods of standard length (Up to 30 cm) with 1.5 sq.mm FRPVC with 1.5 sq.mm. FRPVC insulated copper conductor single core cable etc. as required. |
| 57 | Earthing with copper earth plate 600X600X3 mm thick (with charkol or coke and slat) |
| 58 | 63 amps TPN switch disconnector fuse unit with ISI marked HRC fuses |
| 59 | Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 60 | Dismantling R.C.C. work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 61 | Taking down chaukhats in doors including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 62 | Taking sown chaukhats in windows including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 63 | Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposalof mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge.For door/ window/ clerestory window |
| 64 | Goods & Service Tax (G.S.T.) - |
| 65 | Labour Cess - Please Enable Macros to View BoQ information |