| 1 | \\"Clearing jungle including uprooting of rank vegetation, grass, brush wood,trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m ,outside the periphery of the area cleared. \\" |
| 2 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m. All kinds of soil. |
| 3 | Carriage of materials by mechanical transport including loading, unloading and stacking: Earth upto lead of 1.00 KM. |
| 4 | Brick work with Fly ash bricks of class designation 75 in Superstructure in cement mortar 1:6 (1 cement : 6 coarse sand) |
| 5 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 6 | 12 mm thick cement plaster 1:6 |
| 7 | Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (One or more coat applied @ 0.90 ltr/10 sqm). |
| 8 | 13.87 : White washing with lime to give an even shade : 13.87.1: Old work (two or more coats) |
| 9 | Colour washing with lime to give an even shade (two or more coats on Old work). |
| 10 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 11 | Distempering with 1st quality acrylic distemper etc. : Old work (one or more coats) |
| 12 | 13.99 : Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Painting work………….(One or more coats on old work.) |
| 13 | 13.61 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work.13.61.1 Two or more coats on new work |
| 14 | 10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:. |
| 15 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 16 | 18.15 Providing and fixing brass bib cock of approved quality : 18.15.1 15 mm nominal bore |
| 17 | Providing and fixing brass stop cock of approved quality : 15 mm nominal bore |
| 18 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 15 mm dia nominal bore. |
| 19 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps,i/c making good the walls etc. concealed pipe, including paintingwith anti corrosive bitumastic paint, cutting chases and making goodthe wall : 15 mm dia nominal bore |
| 20 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.25 mm nominal outer dia Pipes . |
| 21 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.15 mm nominal dia Pipes |
| 22 | Providing and fixing decorative type cement bonded wood particle board of Bison or approved make 24 mm thickness (12 mm thick main sheet and 12 mm top rail, lock rail, bottom rail and verticle style) having top rail 100 mm wide, lock rail 150 mm wide and bottom rail 200 mm wide, shutters for doors and windows as per instruction of engineer-in-charge: |
| 23 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 24 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge .21.3.2 With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 25 | 21.14 Providing and fixing anodised aluminium (anodised transparent or dyed to required shade according to IS : 1868. Minimum anodic coating of grade AC 15) sub frame work for windows and ventilators with extruded built up standard tubular sections of approved make conforming to IS: 733 and IS : 1285 fixed with rawl plugs and stainless steel screws etc. |
| 26 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on both faces of shutters.25 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 27 | 15.7 Demolishing brick work, manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable materialwithin 50 metres lead as per direction of Engineer-in-charge. |
| 28 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil. |
| 29 | Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment). |
| 30 | Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). |
| 31 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Sal wood |
| 32 | 12.8: Providing non-asbestos high impact Polypropylene reinforced cement 6 mm thick corrugated sheets (As per IS: 14871) roofing upto any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete excluding the cost of purlins, rafters and trusses corrugated sheets and including cutting to size and shape wherever required |
| 33 | 12.12 Providing and fixing ridges and hips in non-asbestos fibre cement high impact polypropylene reinforced roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc. complete. 12.12.1 Corrugated serrated adjustable ridges |
| 34 | 10.1 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 35 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses,parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 4.2.3 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 36 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated |
| 37 | Painting and writing of slogan board, safety tips etc. complete including cost of paint, brush, scafolding and wages of labour involved. |
| 38 | Godrej NAV TAL-Brass Body ( provide rust reistanace), Rivet-less Construction (Make it nsturdy and tamper-proof),Hardened steel Shakle (Risists hacksaw and crowbar attacks),New Trivalent chrome plating technology (Health and enviroment-friendly plasting process which protect the shackles from rusting too) 65 mm dia Godrej NAV TAL-Brass Body |
| 39 | Providing Interlock (rust reistanace), 6 Chal of approved make |
| 40 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 41 | Generic Red Galvanized iron safety fire bucket |
| 42 | Total Impact of GST for The Purpose of CTC Please Enable Macros to View BoQ information |