| 1 | Earth work in hard soil in excavation including all cost of labour, T&P etc., required for the work, removing the earth within initial lead and lift including dressing & breaking clods to proper profile as directed by the E.I.C. |
| 2 | Filling Foundation & Plinth with sand well watered and rammed with all materials labour, T&P etc complete including cost, conveyance, royalty and taxes for finished item of works and direction of E.I.C. |
| 3 | Cement Concrete of proportion(1:3:6) in foundation and plinth using 4cm size clean hard black granite metal of approved quality from approved quarry including hoisting, lowering and laying in layers not exceeding 15cm thick to the required level, ramming watering and curing etc.complete including cost, conveyance, royalty taxes of all the materials required for the work with all labour, T&P etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 4 | Flyash brick masonry in cement mortar (1:6) in foundation using Flyash bricks of 9\\" size having a crushing strength of not less than 50 kg./sq.cm including splays cutting, circular moulding, chamfering and cur belling, watering and curing etc. complete including cost, conveyance, royalty, taxes of all the materials required for the work with all labour, T&P etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 5 | R.C.C. work of M-20 grade with 20mm and down graded size hard black crusher broken chips of approved quality and from approved quarry including hoisting lowering, laying & compacting concrete watering and curing for 4 weeks, contering, shutting, finishing etc complete. |
| 6 | Column S/S |
| 7 | Plinth beam |
| 8 | Lintel |
| 9 | Chajja |
| 10 | Wall Beam |
| 11 | Roof Slab |
| 12 | Supplying fitting & placing uncoated HYSD bar reinforcement complete as per drawing and tehcinical specification and placing in proper position as requuired for RCC work including cost, conveyance, taxes of still and cost of binding wire etc complete. |
| 13 | Flyash brick masonry in cement mortar (1:6) in super structure using Flyash bricks of 9\\" size having a crushing strength of not less than 50 kg./sq.cm including splays cutting, circular moulding, chamfering and cur belling, watering and curing etc. complete including cost, conveyance, royalty, taxes of all the materials required for the work with all labour, T&P etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 14 | 12mm thick cement plaster (1:6) finished smooth to inside smooth surface of 9\\" /10\\" thick brick walls after raking out the joints including watering and curing with the cost and conveyance of all materials and labour with T&P required for the work |
| 15 | 16mm thick cement plaster (1:6) finished smooth to inside smooth surface of 9\\" /10\\" thick brick walls after raking out the joints including watering and curing with the cost and conveyance of all materials and labour with T&P required for the work. |
| 16 | Providing and fixing Vitrified tiles in floors, treads of steps and landing on 25mm th bed of cement mortar (1:1) (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shade of tiles including rubbing, polishing including cost of tiles, conveyance, taxes & labour, T&P etc. complete as per specification and direction of E.I.C. |
| 17 | Fixing Vitrified Wall Tiles in dadoos skirting & riser of step on12mm thick C.P 1:3 jointed with neat cement slury mixed with with pigment to match the shades of the tile including rubbing & polishing including cost of all etc complete |
| 18 | Providing and fixing Ceramic tiles in floors, treads of steps and landing on 25mm th bed of cement mortar (1:1) (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shade of tiles including rubbing, polishing including cost of tiles, conveyance, taxes & labour, T&P etc. complete as per specification and direction of E.I.C. |
| 19 | Fixing Ceramic Wall Tiles in dadoos skirting & riser of step on12mm thick C.P 1:3 jointed with neat cement slury mixed with with pigment to match the shades of the tile including rubbing & polishing including cost of all etc complete |
| 20 | Priming one coat with approved primer with brush to wall surface after cleaning the surface including cost, conveyance, taxes of all the materials required for the work with all labour, T&P etc. complete as per specification and direction of the Engineer-in-charge. |
| 21 | Distempering two coats over a coat of primer with any approved paint with brush to wall surface including cost, conveyance, taxes of all the materials required for the work with all labour, T&P etc. complete as per specification and direction of the Engineer-in-charge. |
| 22 | Finishing walls with water proofing weather coat paint of approved shade on new work two coats to give an even shade including cost of all labour ,materials T & P with taxes ,transportation etc all complete. |
| 23 | Cost of Door and Window |
| 24 | Cutting holes through the brick or laterite masonry wall for taking sand cast Iron(SCI)/ Centrifugally cast (spun) iron pipes and mending good to damages |
| 25 | Cutting holes through the brick or laterite, masonary wall for taking sand cast iron (SCI) pipes or A.C pipes (250mm to 375mm thick wall) |
| 26 | Cutting groves in pacca floor and walls for taking G.I/ PVC pipes and making good the damages. |
| 27 | Providing and laying in trenches UPVC-ASTM-Standard (Schedule-80)pipe of the following nominal bore and pipe fittings including testing as per specification complete. (Earth work in trenches to be measured and paid for separately) 15 mm dia pipe G.I. |
| 28 | 20mm dia pipe |
| 29 | 25mm dia pvc pipe |
| 30 | 25mm dia brass / GM ball valve |
| 31 | Providing and laying in trenches SWR pipe & fittings of the following nominal bore and pipe fittings including testing as per specification complete. (Earth work in trenches to be measured and paid for separately) 110 mm OD P.V.C. SWR D/S Pipe (ISI type-A) |
| 32 | 75mm OD P.V.C. SWR D/S Pipe (ISI type-A) rain water pipe on roof |
| 33 | 75 mm dia P.V.C. SWR Vent Cowl |
| 34 | 110 mm dia P.V.C. SWR Vent Cowl |
| 35 | 110mm dia P.V.C. Nahani Trap with out Jally |
| 36 | 75 x 75 x 75mm dia PVC SWR Tee |
| 37 | 110 x 110 x 110mm dia PVC SWR Tee |
| 38 | 110mm dia P.V.C. SWR P Trap |
| 39 | 75 mm dia P.V.C. SWR plain bend 45' |
| 40 | 110 mm dia P.V.C. SWR plain bend 45' |
| 41 | 75mm diaP.V.C. SWR door bend 87.5' |
| 42 | 110mm diaP.V.C. SWR door bend 87.5' |
| 43 | 110mm dia PVC SWR coupler |
| 44 | 110mm dia P.V.C. SWR D/J with door |
| 45 | 110 mm dia P.V.C. SWR plain bend 87.5' |
| 46 | 110mm diaP.V.C. SWR.pipe clip |
| 47 | Fixing 100mm size ‘P’ or ‘S’ trap (with horn or without horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1) as per specification. |
| 48 | Supplying , fitting & fixing of following cp fittings as per PH Specification and direction of EIC .15mm dia PVC.long body bib cock |
| 49 | 15 mm PVC 2 in 1 Bib cock . |
| 50 | 15mm PVC concealed stop cock |
| 51 | 15mm dia PVC pillar cock |
| 52 | big flange |
| 53 | 40 mm dia waste Coupling (F/T) |
| 54 | 40mmx1150mm long PVC corrugated waste pipe |
| 55 | 15mmx600mm PVC connection pipe |
| 56 | Supplying , fitting & fixing of following proceline item as per PH Specification and direction of EIC .Porcelain 23'' IWC (Orissa Pan) |
| 57 | 22\\"x 16\\"(550x400) W.H.B |
| 58 | Standard Pedestal |
| 59 | Flat back standing Urinal (Medium) |
| 60 | Urinal Spreader |
| 61 | Fixing glazed earthenware squatting plate of size 600mmx350mm conforming to IS 2556 : Part 6-1995 with intigral longitudinal flushing pipe including embeding the plate in 25mm cement mortar (1:8) laid over 150mm cement concrete (1:4:8) using 40mm hard grabnite metal etc all complete as per specification.One-seated Urinal 1m x 0.50m x 0.15m size (size 600mmx355mm) |
| 62 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. (10 litre capacity - White) |
| 63 | 32mm flush bend |
| 64 | Mirror Cabinet (350mm x 450mm) |
| 65 | C.P. ring |
| 66 | Soap dish/oval |
| 67 | Fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position/ placing the tank on the roof of the toilet building at one corner having both side brick wall & beam diagonally with base plate etc all complete as per specification and direction of the Engineer in charge.2000 litre capacity Double Layer Cylinderical Vertical water storage tanks (ISI Marked) |
| 68 | Supplying all materials, labour and T&P for fitting fixing of following types of P.H. Fittings etc. all complete. 125mm dia C.P Grattings |
| 69 | 25mm dia pvc ball cock with rod |
| 70 | Supplying all materials,labour, T&P for fitting & fixing U PVC S.W.R pipes(4kg/cm2) and fittings of the following outside diameter including jointing with approved solvent cement by non-heat application method testing as per specification with lead of all materials to site.110 mm OD P.V.C. SWR D/S Pipe (ISI type-B) |
| 71 | ii) 110mm dia P.V.C clamp |
| 72 | iii) 110mm dia P.V.C cowl |
| 73 | iv) 110mm dia P.V.C socket |
| 74 | 110mm dia P.V.C. SWR D/J with door |
| 75 | 110mm diaP.V.C. SWR door bend 87.5' |
| 76 | 110 mm dia P.V.C. SWR plain bend 87.5' |
| 77 | 110mm diaP.V.C. SWR.pipe clip |
| 78 | Fixing 100mm size ‘P’ or ‘S’ trap (with horn or without horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1) as per specification. |
| 79 | Supplying of Crompoton 1 HP mono block pump set with its accessories . |
| 80 | Dismantling of Cement Concrete Grade M-15 & M- 20 including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres |
| 81 | Recessed wiring to Light point/Exhaust Fan Point with 1.5 sqmm, FR PVC Insulated single core multistrand copper conductor of ISI marked with 20 mm dia non- metallic PVC flexible conduct with 5 Amp, 250 V Modular type switch ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover of suitable size,MS box with 1.5 sqmm FR PVC insulated single core multistrand copper conductor and earth wire incouding all accessories and connection as per direction of engineer in charge (Make of wire = Finolex/L&T/ Anchor/ V-Guard) deducting the cost of 2M Box with cover Plate-1 No.) Group A 1.2.1-1.24.2 |
| 82 | -do-………Group B 1.2.2 - 1.24.2 |
| 83 | -do-………. Group C 1.2.3 - 1.24.2 |
| 84 | Recessed wiring to Fan point in Group B 1.2.2 - 1.24.2 |
| 85 | Recessed wiring to Callbell point in Group C 1.2.3 - 1.24.2 |
| 86 | Supply and Fixing of 4M GI box on surface or in recess with suitable size of Modular base cover cover in front including providing and fixing 3 pin 5/6 amp. Modular Socket out let & 5/6amp. Modular type switch,connection,painting etc. as required (Separate) (1.25.1+1.25.4) |
| 87 | Supply and Fixing of 5/6 Modular Switch & 3pin 5/6A Modular Socket on existing board (Existing) (1.25.1+1.25.4) |
| 88 | Supply and Fixing to 16/18 SWG Modular GI box of following sizes (normal sixe) in recess with suitable size of Modular Base & Cover in front including cutting the wall and making good the same in case of recessed conduit as required.for 2 Module (1.24.1) |
| 89 | ..do 4 Module |
| 90 | -do-6 Module |
| 91 | -do-8 Module |
| 92 | -do-12 Module |
| 93 | Wiring for circuit/sub main alongwith earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20 mm dia non metallic heacy duty flexible conduit 1.6 mm in recessed PVC conduit as required (make of wire-Finolex/L&T/Anchor/Havels/V-Guard). 2x1.5 sqmm + 1 x 1.0 sqmm( 1 .8) |
| 94 | -do- 2 x 2.5 sqmm + 1 x 1.5 sqmm (1.8.2) |
| 95 | -do- 2x4 sqmm + 1 x 1.5 sqmm (1.8.3) |
| 96 | -do- 4x6sqmm +2x2.5sqmm (1.8.10) |
| 97 | Supply, Installation, Testing, and Commissioning of 63 Amp TPN Main switches of following capacity (IS 13940 Part 3/1993 ) on existing surface / wall mountnting and complete with HRC Fuse links, interconnections, earthing, etc. as required as per direction of Engineer in Charge.Make-SEIMENS/HPL/ANCHOR/L&T/HAVELS/C & S/ RK (2.15.3) |
| 98 | Supply and Fixing of 5 to 32 Amp rating 240 Volt \\"B\\" series MCB for lighting and other loads in the existing MCB Distribution Board ISI marked complete with connection, testing and commissioning etc. as required (2.6.1) |
| 99 | Supply and Fixing of 6 way (6+18) TPN MCB DB double door (2.5.6) |
| 100 | Supply, Installation, Testing and commissioning of bulkhead fittings including fixing of 5 watt LED Lamp (Make:Havels with die cast aluminium housing and frosted glass cover).RUGBY |
| 101 | Supply and Fixing of batten holder BK angle holder ISI marked including connection etc. instead of ceiling rose(1.29- 1.28) |
| 102 | Supply and Fixing of 15W LED Bulb |
| 103 | Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick including accessories and providing masonary with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required.(3.5+3.6) |
| 104 | Supply andlaying 8 SWG copper wire in recess for loop earthing as required (3.18) |
| 105 | Supply and Fixing of 48\\" A.C.Cilling fan without regulator including all conections Model:Crompton (jura)/ Usha-(Striker Millenium) /Havells (Velocity/Spark) / Anchor - (XL)/ Orient-(Summer Pride) |
| 106 | S/F of 24W Recess Mounted Square Shape LED luminary,Make-Havells/Crompton/Philips |
| 107 | Supply, Installation, Testing and commissionioning of 225mm sweep exhaust fan in the existing opening, including making the hole to suit the size of the above fan making good the damaged comlete, connection,etc. as required.(1.43)(Make: Bajaj/Almonard) |
| 108 | S/F of computer board consisting of 3 nos. of 5 amp Modular plug and switch complete with wiring on 12M GI.box with Front cover(1.24.9 +1.25.4 + 2.5.1) |
| 109 | S/F Call bell/Buzzer ISI marked suitable for DC/AC single Phase 230 volts complete as required.(1.30) |
| 110 | S/F of 60 watt. LED street light fitting including necessary connection. (Make- crompton/poly cab/Havells/ HPL/Philips) |
| 111 | S/F of 1.5sqmm mult-strand copper wire for invertor wiring |
| 112 | S/F of 6 pin 15/16A Modular socket (1.25.5) |
| 113 | S/F of 100W Step type Modular Regulator |
| 114 | S/F of 32A DP Modular Switch with Neon Indicator (Heavy Duty) |
| 115 | S/F of 32A DP MCB for AC |
| 116 | S/F of 63A FP MCB Please Enable Macros to View BoQ information |