| 1 | Earth work in hard soil in excavation including all cost of labour, T&P etc., required for the work, removing the earth within initial lead and lift including dressing & breaking clods to proper profile as directed by the E.I.C. |
| 2 | Filling Foundation & Plinth with sand well watered and rammed with all materials labour, T&P etc complete including cost, conveyance, royalty and taxes for finished item of works and direction of E.I.C. |
| 3 | Cement Concrete of proportion(1:3:6) in foundation and plinth using 4cm size clean hard black granite metal of approved quality from approved quarry including hoisting, lowering and laying in layers not exceeding 15cm thick to the required level, ramming watering and curing etc.complete including cost, conveyance, royalty taxes of all the materials required for the work with all labour, T&P etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 4 | P.C.C. work in (1:2:4) with 12mm size crusher brocken h.g. chips mixing with concrete mixture laying , compacting including cost of all material with taxes , watering, curing labour required for the work etc but excluding centring, shuttering . Complete as per direction of E-I-C.Cement concrete (1:2:4) using 12mm. size c.b.b.h.g chips including cost of all materials etc. complete. |
| 5 | Flyash brick masonry in cement mortar (1:6) in foundation using Flyash bricks of 9\\" size having a crushing strength of not less than 50 kg./sq.cm including splays cutting, circular moulding, chamfering and cur belling, watering and curing etc. complete including cost, conveyance, royalty, taxes of all the materials required for the work with all labour, T&P etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 6 | R.C.C. work of M-20 grade with 20mm and down graded size hard black crusher broken chips of approved quality and from approved quarry including hoisting lowering, laying & compacting concrete watering and curing for 4 weeks, contering, shutting, finishing etc complete. |
| 7 | Column S/S |
| 8 | Plinth beam |
| 9 | Lintel |
| 10 | Chajja |
| 11 | Wall Beam |
| 12 | Roof Slab |
| 13 | Roof Slab 1st floor |
| 14 | stair case landing |
| 15 | Supplying fitting & placing uncoated HYSD bar reinforcement complete as per drawing and tehcinical specification and placing in proper position as requuired for RCC work including cost, conveyance, taxes of still and cost of binding wire etc complete. |
| 16 | Flyash brick masonry in cement mortar (1:6) in super structure using Flyash bricks of 9\\" size having a crushing strength of not less than 50 kg./sq.cm including splays cutting, circular moulding, chamfering and cur belling, watering and curing etc. complete including cost, conveyance, royalty, taxes of all the materials required for the work with all labour, T&P etc. complete in all respect as per specification and direction of the Engineer-in-charge. |
| 17 | 12mm thick cement plaster (1:6) finished smooth to inside smooth surface of 9\\" /10\\" thick brick walls after raking out the joints including watering and curing with the cost and conveyance of all materials and labour with T&P required for the work |
| 18 | 16mm thick cement plaster (1:6) finished smooth to inside smooth surface of 9\\" /10\\" thick brick walls after raking out the joints including watering and curing with the cost and conveyance of all materials and labour with T&P required for the work. |
| 19 | Providing and fixing Vitrified tiles in floors, treads of steps and landing on 25mm th bed of cement mortar (1:1) (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shade of tiles including rubbing, polishing including cost of tiles, conveyance, taxes & labour, T&P etc. complete as per specification and direction of E.I.C. |
| 20 | Fixing Vitrified Wall Tiles in dadoos skirting & riser of step on12mm thick C.P 1:3 jointed with neat cement slury mixed with with pigment to match the shades of the tile including rubbing & polishing including cost of all etc complete |
| 21 | Providing and fixing Ceramic tiles in floors, treads of steps and landing on 25mm th bed of cement mortar (1:1) (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shade of tiles including rubbing, polishing including cost of tiles, conveyance, taxes & labour, T&P etc. complete as per specification and direction of E.I.C. |
| 22 | Fixing Ceramic Wall Tiles in dadoos skirting & riser of step on12mm thick C.P 1:3 jointed with neat cement slury mixed with with pigment to match the shades of the tile including rubbing & polishing including cost of all etc complete |
| 23 | Priming one coat with approved primer with brush to wall surface after cleaning the surface including cost, conveyance, taxes of all the materials required for the work with all labour, T&P etc. complete as per specification and direction of the Engineer-in-charge. |
| 24 | Distempering two coats over a coat of primer with any approved paint with brush to wall surface including cost, conveyance, taxes of all the materials required for the work with all labour, T&P etc. complete as per specification and direction of the Engineer-in-charge. |
| 25 | Finishing walls with water proofing weather coat paint of approved shade on new work two coats to give an even shade including cost of all labour ,materials T & P with taxes ,transportation etc all complete. |
| 26 | Cost of Door and Window |
| 27 | Cutting holes through the brick or laterite masonry wall for taking sand cast Iron(SCI)/ Centrifugally cast (spun) iron pipes and mending good to damages |
| 28 | Cutting holes through the brick or laterite, masonary wall for taking sand cast iron (SCI) pipes or A.C pipes (250mm to 375mm thick wall) |
| 29 | Cutting groves in pacca floor and walls for taking G.I/ PVC pipes and making good the damages. |
| 30 | Providing and laying in trenches UPVC-ASTM-Standard (Schedule-80)pipe of the following nominal bore and pipe fittings including testing as per specification complete. (Earth work in trenches to be measured and paid for separately) 15 mm dia pipe G.I. |
| 31 | 20mm dia pipe |
| 32 | 25mm dia pvc pipe |
| 33 | 25mm dia brass / GM ball valve |
| 34 | Providing and laying in trenches SWR pipe & fittings of the following nominal bore and pipe fittings including testing as per specification complete. (Earth work in trenches to be measured and paid for separately) 110 mm OD P.V.C. SWR D/S Pipe (ISI type-A) |
| 35 | 75mm OD P.V.C. SWR D/S Pipe (ISI type-A) rain water pipe on roof |
| 36 | 75 mm dia P.V.C. SWR Vent Cowl |
| 37 | 110 mm dia P.V.C. SWR Vent Cowl |
| 38 | 110mm dia P.V.C. Nahani Trap with out Jally |
| 39 | 75 x 75 x 75mm dia PVC SWR Tee |
| 40 | 110 x 110 x 110mm dia PVC SWR Tee |
| 41 | 110mm dia P.V.C. SWR P Trap |
| 42 | 75 mm dia P.V.C. SWR plain bend 45' |
| 43 | 110 mm dia P.V.C. SWR plain bend 45' |
| 44 | 75mm diaP.V.C. SWR door bend 87.5' |
| 45 | 110mm diaP.V.C. SWR door bend 87.5' |
| 46 | 110mm dia PVC SWR coupler |
| 47 | 110mm dia P.V.C. SWR D/J with door |
| 48 | 110 mm dia P.V.C. SWR plain bend 87.5' |
| 49 | 110mm diaP.V.C. SWR.pipe clip |
| 50 | Fixing 100mm size ‘P’ or ‘S’ trap (with horn or without horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1) as per specification. |
| 51 | Supplying , fitting & fixing of following cp fittings as per PH Specification and direction of EIC .15mm dia PVC.long body bib cock |
| 52 | 15 mm PVC 2 in 1 Bib cock . |
| 53 | 15mm PVC concealed stop cock |
| 54 | 15mm dia PVC pillar cock |
| 55 | big flange |
| 56 | 40 mm dia waste Coupling (F/T) |
| 57 | 40mmx1150mm long PVC corrugated waste pipe |
| 58 | 15mmx600mm PVC connection pipe |
| 59 | Supplying , fitting & fixing of following proceline item as per PH Specification and direction of EIC .Porcelain 23'' IWC (Orissa Pan) |
| 60 | 22\\"x 16\\"(550x400) W.H.B |
| 61 | Standard Pedestal |
| 62 | Flat back standing Urinal (Medium) |
| 63 | Urinal Spreader |
| 64 | Fixing glazed earthenware squatting plate of size 600mmx350mm conforming to IS 2556 : Part 6-1995 with intigral longitudinal flushing pipe including embeding the plate in 25mm cement mortar (1:8) laid over 150mm cement concrete (1:4:8) using 40mm hard grabnite metal etc all complete as per specification.One-seated Urinal 1m x 0.50m x 0.15m size (size 600mmx355mm) |
| 65 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. (10 litre capacity - White) |
| 66 | 32mm flush bend |
| 67 | Mirror Cabinet (350mm x 450mm) |
| 68 | C.P. ring |
| 69 | Soap dish/oval |
| 70 | Fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position/ placing the tank on the roof of the toilet building at one corner having both side brick wall & beam diagonally with base plate etc all complete as per specification and direction of the Engineer in charge.2000 litre capacity Double Layer Cylinderical Vertical water storage tanks (ISI Marked) |
| 71 | Supplying all materials, labour and T&P for fitting fixing of following types of P.H. Fittings etc. all complete. 125mm dia C.P Grattings |
| 72 | 25mm dia pvc ball cock with rod |
| 73 | Supplying all materials,labour, T&P for fitting & fixing U PVC S.W.R pipes(4kg/cm2) and fittings of the following outside diameter including jointing with approved solvent cement by non-heat application method testing as per specification with lead of all materials to site.110 mm OD P.V.C. SWR D/S Pipe (ISI type-B) |
| 74 | ii) 110mm dia P.V.C clamp |
| 75 | iii) 110mm dia P.V.C cowl |
| 76 | iv) 110mm dia P.V.C socket |
| 77 | 110mm dia P.V.C. SWR D/J with door |
| 78 | 110mm diaP.V.C. SWR door bend 87.5' |
| 79 | 110 mm dia P.V.C. SWR plain bend 87.5' |
| 80 | 110mm diaP.V.C. SWR.pipe clip |
| 81 | Fixing 100mm size ‘P’ or ‘S’ trap (with horn or without horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1) as per specification. |
| 82 | Supplying of Crompoton 1 HP mono block pump set with its accessories . |
| 83 | Dismantling of Cement Concrete Grade M-15 & M- 20 including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres |
| 84 | Recessed wiring to light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with S.P 5/6Amp, one way modular switch ISI marked(L&T/crabtree/ Havells/ ROMA/ SIEMENS/ Finolex) and ceiling rose ISI marked mounted on Modular GI box of 18SWG having modular base & cover of suitable size with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex / L&T / Anchor / Havels / V Guard )Group-A. L.P.- 10 F.P.- 0 C.B.- |
| 85 | Group-B. L.P.- 10 F.P.- 2 C.B.- |
| 86 | Group-C L.P.- 15 F.P.- 5 C.B.- |
| 87 | Recessed wiring for 5/6Amp modular Socket outlet with 2x1.5mm2 FR PVC insualted single core multistand copper conductor of ISI marked in recess 20mm dia Non-metalic PVC flexible conduit with piano type switch,phenolic laminated sheet suitable size ISI marked on modular GI box and earthing point with 1x1.5sqmm FR PVC insulated single core multistand copper conductor for loap earthing etc.as required(make of wire-Finolex/L&T/Anchor/ Havels/V-Guard)Group-A. |
| 88 | On Existing board. |
| 89 | Recess wiring for circuit/submain wiring with the following mentioned size PVC FRLSH/LSZH insulated, copper conductor, single core cable (Finolex/Anchor/Polycab/ HAVELLS/RR KEBLE) or equievalant reputed make A catagory ISI marked as approved, in recessed PVC conduit Heavy duty FRLS of mentioned size (AKG/Anchor/Kinjal or equievalant ISI marked as approved) as required as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materialsa)1x1.5mm2(1.19.2.SOR-17) Inverter wiring |
| 90 | b)2x2.5mm2+1x1.5mm2(1.8.2.SOR-17) |
| 91 | c)2x4mm2+1x1.5mm2 (1.8.3.SOR-17) |
| 92 | d)4x6mm2+ 2x2.5mm2(1.8.8.SOR-17) |
| 93 | e) 4x10mm2 + 2x4mm2 |
| 94 | S/F.of Bakelite angle holder/batten holder of ISI marked conforming to IS-1258/1987 in place of Ceiling rose. |
| 95 | p/f.of 6 SWG GI WIRE |
| 96 | Supplying and fixing Modular G.l. box of 18 SWG on surface or in recess with Modular base & cover for module in front including providing and fixing 6pin 15/16Amp modular socket outlet and SP 15/16Amp oneway modular switch (Power Plug) with indicator connection, painting etc as required. |
| 97 | P/F of 6 SWG G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/ submain wiring/cable as required((To be connected to DBs) |
| 98 | S/F.of Computer board consisting of 4Nos 5/6AMP modular socket & modular switch including suitable size of GI modular box and modular base &cover (ROMA/ Crabtree/ Havells/L&T or equivalent make)complete with connection as per the direction of Engineer-in-Charge. |
| 99 | Supplying and fixing of Modular G.l. box for suitable module on surface or in recess with Modular base & cover and blanking plate ( if required) in front including providing and fixing of 25AMP DOL starter (ROMA/ Crabtree/ Havells or equivalent make ) of modular type switch, connection, painting etc as required as per the direction of Engineer-in-Charge. |
| 100 | S/F of 36x30x10 no 16/18 SWG sheet metal for main 100 amp panel board having 100 amp MCCB 25 KA as incommer, 100 amp electrolyte cu bus bar, 100Amp 4 pole change over, 63A,16 kAbFP MCCB-2No.,63A 4 pole mcb 4 nos and 63A DP MCB-3No., as Outgoing with ampere meter, voltmeter, toggler switch,three nos led indicator and as per the direction of site engineer in charge.(make: Siemens / legrand/Schneider/Equivalent)) |
| 101 | 100/125 amp, 415 V ICTPN main switch (HPL / L&T / C&S / SEIMENS / RK / ANCHOR / HAVELS)(IS 13940 Part 3/1993 ) on existing surface / wall mountnting and complete with HRC Fuse linksinterconnections, earthing, etc. as required as per direction of Engineer in Charge. |
| 102 | S/F of (4+12) way TPN Double door LIGHT D. Box (Hager/ L&T/ C&S/Legrand or equivalent make ) with 12x(6-32Amp)SP MCB of Hager/ L&T/Legrand/C&S or Equivalent make including all accessories and connection. as per direction Engineer-in-Charge. |
| 103 | Supply and Fixing of following rating 4 pole 415 V 63 Amp MCB of \\"C\\" series in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required. (Make-HPL/ Havells/ Legrand / L&T/ ABB or equivalent). |
| 104 | S/F of 35 sq.mm 3&1/2 Core Alluminium, armoured LT power Cable of XLPE insulated 650/1100 grade(make-Havells/Polycab or Equivalent.) |
| 105 | Supply and Fixing of 48\\" A.C.Cilling fan without regulator including all conections Model:Crompton (jura)/ Usha-(Striker Millenium) /Havells (Velocity/Spark) / Anchor - (XL)/ Orient-(Summer Pride) |
| 106 | S/F of 24W Recess Mounted Square Shape LED luminary,Make-Havells/Crompton/Philips |
| 107 | S/F of Fan hook S, Type on ceiling.(M-22) |
| 108 | Supply, Installation, Testing and commissionioning of 225mm sweep exhaust fan in the existing opening, including making the hole to suit the size of the above fan making good the damaged comlete, connection,etc. as required.(1.43)(Make: Bajaj/Almonard) |
| 109 | S/F of computer board consisting of 3 nos. of 5 amp Modular plug and switch complete with wiring on 12M GI.box with Front cover(1.24.9 +1.25.4 + 2.5.1) |
| 110 | S/F Call bell/Buzzer ISI marked suitable for DC/AC single Phase 230 volts complete as required.(1.30) |
| 111 | S/F of 60 watt. LED street light fitting including necessary connection. (Make- crompton/poly cab/Havells/ HPL/Philips) |
| 112 | S/F of 1.5sqmm mult-strand copper wire for invertor wiring |
| 113 | S/F of 6 pin 15/16A Modular socket (1.25.5) |
| 114 | S/F of 100W Step type Modular Regulator |
| 115 | S/F of 32A DP Modular Switch with Neon Indicator (Heavy Duty) |
| 116 | S/F of 32A DP MCB for AC |
| 117 | S/F of 63A FP MCB Please Enable Macros to View BoQ information |