| 1 | Civil Work WORKS (PART-I)Earthwork in excavation of foundation in hard soil or gravelly soil within 50m initial lead and 1.5m, initial lift including shoring,shuttering, propping bullahs, piling,dewatering from foundation, with & working pumps & staking the excaveted materials away from the working area including rough dressing the bed and foundation tranches to required size including cost, conveyance, taxes, cess, royalties of all materials, cost of all labour, T&P required for the work etc. complete as per specification & direction of Engineer-in-charge |
| 2 | Supplying and filling in foundation and plinths with sand well watered and compacted including cost of all materials, labour, conveyance, loading and unloading, taxes, cess, royalties, watering, sundries, tools and plants, etc., complete as per the direction of the Engineer-in-charge. |
| 3 | Providing and laying plain cement concrete (1:3:6)(using branded cement) in foundation using 40 mm size hard crusher broken granite metal of approved quality from approved quarry including mixing, lowering, laying and compacting to proper thickness, watering and curing for the required period including cost of all material, labour, conveyance, loading and unloading, taxes,cess, royalties, scaffolding, watering, curing, sundries, tools and plants,etc. ,complete as per the direction of the Engineer-in-charge. |
| 4 | Providing and laying plain cement concrete (1:2:4)(using branded cement) in superstructure using 12 mm size hard crusher broken granite chips of approved quality from approved quarry including mixing, lowering, laying and compacting to proper thickness, watering and curing for the required period including cost of all material, labour, conveyance, loading and unloading, taxes, cess,royalties, scaffolding, watering, curing, sundries, tools and plants,etc. ,complete as per the direction of the Engineer-in-charge. |
| 5 | Providing 2.5mm thick Damp Proof Course with cement concrete (1:2:4) (Using Branded Cement) using 12mm size hard granite crusher broken chips including watering and curing with cost, conveyance, royalties and taxes of all materials with cost of all labour, labour cess and T&P required for the work etc. complete in all respect as per specification & direction of Engineer-in-charge |
| 6 | Fly Ash brick masonry in cement mortar (1:6) (Using Branded Cement) in foundation & plinth using Fly Ash bricks of 25x12x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per specification & direction of Engineer-in-charge. |
| 7 | Providing Fly Ash brick masonry work in super structure using 25 X 12 X 8 cm (with dimensional tolerance of ± 2% ) Fly Ash bricks having crushing strength not less than 75 kg. / sq cm, mortar of mix 1:6 (1 cement : 6 sand),(using branded cement) immersing the bricks for minimum 6 hrs in water before use, with all necessary projections, splay cutting, circular moulding, corbelling, etc., including cost of all materials, labour, conveyance, loading and unloading, taxes, cess, royalties, scaffolding, watering, curing, sundries, tools and plants,etc., complete as per the direction of the Engineer-in-charge. |
| 8 | Providing 12 mm thick cement mortar 1:6 (1 cement : 6 sand )(using branded cement) to outside surface / plumbed surface of masonry, raking out joints, scrapping and cleaning the surface and finishing the plastered surface smooth to proper plumb and levels and providing grooves or beads where ever necessary, including cost of all materials, labour, conveyance, loading and unloading, taxes, cess, royalties, scaffolding, watering. curing, sundries, tools and plants etc. complete as per the direction of the Engineer-in-charge. |
| 9 | Providing 16 mm thick cement plaster with cement mortar of mix (1:6) (Using Branded Cement) with screened and washed sharp sand for mortar and finished smooth to the inside rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves or beads where ever necessary with cost, conveyance, royalties and taxes of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as per specification & direction of Engineer-in-charge. |
| 10 | Finishing wall surface with painting two coats with Weather coat paint (1st quality) exterior grade over a coat of Cement Primer (Water based) of approved make & approved shade to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cess, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge. |
| 11 | Steel work of grade - Yst 250 in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer with welding and bolted with special shaped washers (Hot finished seamless type tubes) including cost, conveyance of all materials, all labour, T&P etc complete as per approved design and specification. |
| 12 | Supply & installation of shingles roofing system (make IKO/Saint gobain or equivalent) with landmark MR size 335x984 mm ridge cover 300x300mm, swift starter 6 1/2\\" x 3'4\\" cover with 12mm cement fiberboard using roof corner synthetic under layer including all requiring hardwares, cost of sysnthetic under layer, above tools, tackles, cost of all materials, taxes, cess, labour, conveyance, royalties etc. complete, as per the direction of the Engineer-in-charge. |
| 13 | Supply & fixing of Aluminium composit panel syatem (ACP system) including all requiring hardwares, above tools, tackles, cost of all materials, taxes, cess, labour, conveyance, royalties etc. complete, as per the direction of the Engineer-in-charge. |
| 14 | Painting two coats with Synthetic enamel paint of approved quality and shade over a coat of primer (Red Oxide Primer) on surfaces as specified below Steel Surface) to give an even shade with 2 coats of approved quality paint, including cost of all materials, labour, conveyance, taxes, cess, royalties, scaffolding. watering, curing, sundries. tools and plants, etc., complete as per the direction of the Engineer-in-charge. |
| 15 | Supplying, fitting and fixing vitrified tiles of premium grade having thickness 10mm confirming to IS 13755 of size 600mm x 600mm Coloured / Printed series (homogenious) of approved make a shade (Orient Bell, Somany, Kajaria, Johnson) in floors on 20mm thick bed of C.M. (1:4) (Using Branded Cement) and filling the joint with white cement mixed with pigment to match the shades of the tile including washing and cleaning with oxalic acid complete including cost of all materials, taxes, labour, labour cess, T&P etc. required for the work complete in all respect as per specification & direction of Engineer-in-charge. |
| 16 | Providing, fitting, fixing vitrified tiles of premium grade having thickness 10mm confirming to IS 13756 of size 600mm x 600mm Coloured / Printed series (homogenious) of approved make (Orient Bell, Somany, Kajaria, Johnson) in dados skirting and risers of steps on 12mm thick cement plaster (1:3) (Using Branded Cement) jointed with neat cement mixed with pigment to match the shades of the tiles including washing and cleaning with oxalic acid and polishing etc. complete with cost, conveyance, royalties and taxes of all materials all labour,labour cess complete in all respects as per specification & direction of Engineer-in-charge. |
| 17 | Providing R.C.C M-20 grade (Using Branded Cement) with 20mm and down grade hard granite (crusher broken) aggregate and fine aggregate conforming to IS 383) in Drain as per approved drawing including dewatering, centering and shuttering, cost, conveyance, taxes, cess,royalties of all materials, cost of all labour, T&P required for the work etc. complete as per specification & direction of Engineer-in-charge.a) Drain Cover Slab |
| 18 | Supplying steel i.e. Tor Steel / HYSD Bars conforming IS-1786 including straightening, cutting, bending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and providing fan hooks as required, hoisting, lowering, laying including cost, conveyances, taxes tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (Linear measurement will be taken and quantity will be calculated on standard weight of tor steel / HYSD bars for all heights) complete as per specification & direction of Engineer-in-charge. |
| 19 | Providing fitting and fixing of false ceilling with Aluminium anodised T Section No.3215 with 2'-0\\" center to center, L section No. 1705 upto 15 micron on 4 walls to be fixed by means of steel screw and P.V.C plug and the Aluminium grid 2'-0\\"x2'-0\\" with gypsum board suspended from ceiling, hire charges of drilling machine, labour charges, making good to all damages in walls and floors etc. including cost of all materials, labour, conveyance, loading and unloading, taxes, cess, royalties, scaffolding, sundries, tools and plants etc. complete as per the direction of the Engineer-in-charge. |
| 20 | GI Sheet Gutter upto 30cm Wide fixing with clamps and making connection with rain water pipes etc complete including cost of all materials, labour, conveyance, loading and unloading, taxes, cess, royalties, scaffolding, sundries, tools and plants etc. complete as per the direction of the Engineer-in-charge. |
| 21 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per specification & direction of the Engineer-in-charge. |
| 22 | Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP-63:2018 and including cost, conveyance, taxes, cess, royalties of all materials, cost of all labour, T&P required for the work etc. complete as per specification & direction of Engineer-in-charge |
| 23 | E.I. WORKS (PART-III)Recessed wiring to light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5 Amp, 250 V Modular type switch ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex / KEI / Anchor / Havells /Polycab) (Make of Switch, Socket & Regulator -Cona(PM)/Anchor(Roma Classic)/Havells(Phems)/Legrand) ( wire colour code to be followed i.e . Neutral-Black, Earthing-Green Phase-R-Y-B )Group-A -L.P- F.P- C.B.P- |
| 24 | Group-B L.P- F.P- C.B.P- |
| 25 | Group-C L.P- F.P- C.B.P- |
| 26 | Point wiring for 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in recess 20 mm dia non-metalic PVC flexible conduit with piano type switch , phenolic laminated sheet suitable size ISI marked MS box and earthing point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc. as required. |
| 27 | Supply and fixing of 5 Amp plug with switch on existing board (Modular type/cover including connection etc. as required ) |
| 28 | Circuit Submain wiring in PVC Conduit2 X 1.5 sq.mm +1 X 1.5 sq.mm in 20 mm dia |
| 29 | 2 X 2.5 sq.mm +1 X 1.5 sq.mm -do- |
| 30 | S/F of A.C. Ceiling fan of size 48\\" without regulator . (Make- Usha(swift/racer)/Havells/Crompton-Breeza) (Except brown colour) |
| 31 | Supply and fixing of Electronic Step Type fan regulator (Make-Cona/ Anchor/ Usha/Bajaj) |
| 32 | Installlation, Testing and commissioning of ceiling fan including wiring the down rod of standard length(up to 90 cm) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor etc. as required. |
| 33 | S/F of 36 Watt square shaped LED Ceiling light (Havells/Phillips/CG) |
| 34 | Supply and fixing of 4 way (4+12) double door TPN DB with sheet steel enclosure,distribution board,on suface/recess,complete with tinned copper bus bar,neutral bus bar,earth bar,din bar,detachable gland plate,interconnection,phosphate and powder painted including earthing etc.as required. (L&T/Havells/Anchor) |
| 35 | Supply and fixing of 6Amp single pole MCB(Make-Havells(Craptree)/L&T/Legrand) |
| 36 | S/F of 32 Amp four pole MCB (L&T/Havells) |
| 37 | S/F of computer board consisting 3 nos 5amp switch and socket |
| 38 | S/F of 6 sq.mm 4 core Copper Armoured cable(Havells/Polycab/HPL) |
| 39 | Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface. Please Enable Macros to View BoQ information |