| 1 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 2 | Group C |
| 3 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 4 | 3 x 1.5 sq. mm |
| 5 | 3 x 4 sq. mm |
| 6 | 6 x 6 sq. mm |
| 7 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 8 | 32 mm |
| 9 | Supply and fixing of 32 x 20 mm DLP mini- trunking white-system with independent cover etc. as required complete. |
| 10 | Supply and fixing of following accessories suitable for 32 mm x 20 mm size plastic trunking white system. |
| 11 | End cap |
| 12 | Internal / external angle |
| 13 | Changeable flat angle |
| 14 | Flat junction |
| 15 | Supplying and fixing following rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 16 | Single pole 5 A to 32 A |
| 17 | Triple pole 5 A to 32 A |
| 18 | Triple pole and neutral 5 A to 32 A |
| 19 | Triple pole 40 A to 63 A |
| 20 | Four Pole (40A-63A) |
| 21 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 22 | 125 A,36KA,FPMCCB |
| 23 | 200 A,36KA,FPMCCB |
| 24 | Chemical Earthing with Copper bonded rod of copper coating of 250 microns of dia 25 mm, length 3 Mtr with clamp, including earth enhancement material and RCC precast Pit cover and earthing pit etc as reqd. complete. |
| 25 | Chemical Earthing with GI earth electrode 50 mm dia x 3 Mtr length with full GI strip including earth enhancing compound and RCC precast PIT cover and earthing pit etc as reqd. |
| 26 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.l. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 27 | Providing and fixing 25 mm X 5 mm G.l. strip on surface or in recess for connections etc. as required. |
| 28 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 29 | Providing and fixing 6 SWG dia G.l. wire on surface or in recess for loop earthing as required. |
| 30 | S & F following size of steel flexible pipe along with the accessories on surface etc as required |
| 31 | 32 mm |
| 32 | S & F metal enclosure suitable for DP/TPN MCB / DP ELCB on surface or recessed etc as reqd. |
| 33 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. |
| 34 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 35 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 36 | Providing, laying and fixing following dia G.l. pipe (medium class) in ground complete with G.l. fittings including trenching (75 cm deep)and re-filling etc as required |
| 37 | 100 mm dia |
| 38 | Supplying and laying of one no. 3.5 x 35.0 sqmm PVC insulated, XLPE steel armoured aluminium conductor power cable of grade 1.1 kV as required complete in following manners. |
| 39 | In ground I/c excavation, sand cushioning, protective covering and refixing the trench etc as reqd |
| 40 | One number additional in the same trench including excavation, sand cushioning, protective covering and refilling the trench |
| 41 | In open duct |
| 42 | On Surface |
| 43 | Supplying and laying of one no. 3.5 x 95.0 sqmm PVC insulated, XLPE steel armoured aluminium conductor power cable of grade 1.1 kV as required complete in following manners. |
| 44 | In ground I/c excavation, sand cushioning, protective covering and refixing the trench etc as reqd |
| 45 | one number additional in the same trench including excavation, sand cushioning, protective covering and refilling the trench |
| 46 | In open duct |
| 47 | On Surface |
| 48 | Supplying and laying of one no. 3.5 x 400.0 sqmm PVC insulated, XLPE steel armoured aluminium conductor power cable of grade 1.1 kV as required complete in following manners. |
| 49 | In ground I/c excavation, sand cushioning, protective covering and refixing the trench etc as reqd |
| 50 | one number additional in the same trench including excavation, sand cushioning, protective covering and refilling the trench |
| 51 | In Pipe |
| 52 | In open duct |
| 53 | On Surface |
| 54 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 55 | 3½ X 35 sq. mm (32mm) |
| 56 | 3½ X 95 sq. mm (45mm) |
| 57 | 3½ X 400 sq. mm (82mm) |
| 58 | Supplying, fixing testing and commissioning of following ways, surface/ recess mounting, vertical type, 415 volts, TPN distribution board of sheet steel, dust protected, duly powder painted, inclusive of 160/250 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required complete. |
| 59 | 12 way , Double door, with provision of 250 A MCCB as incommer |
| 60 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 61 | 8 way (4 + 24), Double door |
| 62 | Supplying, installation, testing and commissioning of 2mm thick CRCA sheet cubical type floor mounted front accessible top entry switchgear LT panel with FP aluminium bus bar of 800 amp capacity in all four busbars, as per following details and enclosed specifications. |
| 63 | Incomer: 2 Nos. |
| 64 | 630A FP,36kA MCCB with microprocessor based release for LISG protection, Rotary handle spreader link, aux. trip contact and AC1 duty 630A FP contactor, RYB and on off trip LED indication, Digital multifunction meter with A,V., PF, Kwh, run hour functions. |
| 65 | Bus coupler: 1 Nos. |
| 66 | AC1 duty 630A FP contactor, Auto manual selector switch start stop push button with on delay timer |
| 67 | Out Going: |
| 68 | a) MCCB FP 250 A with LSI adjustable Thermal magnetic release - 3 Nos. b) MCCB FP 160 A with LSI adjustable Thermal magnetic release - 3 Nos. c) MCCB FP 100 A with LSI adjustable Thermal magnetic release - 2 Nos. |
| 69 | S&F connecting and commissioning independent mounting of MCCB enclosure suitable for MCCB's up to 250A in surface/recess I/c cutting the wall and making good the same in case of recessed (Cat No CS-CNM0100021 C & S or approved equivalent make) as reqd. |
| 70 | Supplying and laying Insulating mat \\"Shock safe\\" in front of electrical panels, ISI marked as required somplete. |
| 71 | Supply and fixing of following LED light fixture with efficiency >100 lumen/ watt, P.F. >0.95, THD<10%, Electronic driver, LED lamp, reflector, diffuser, MS body/housing holder etc. complete with all fixing accessories and lamp as required complete. |
| 72 | 1 X 20W Box type LED tube with fitting |
| 73 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Please Enable Macros to View BoQ information |