| 1 | Part-A (Internal Electrification) |
| 2 | Wiring for Light point/Exhaust point with (P+N) 2x1.5 sq.mm FRLS-H/HFFR PVC insulated Multi strand Copper conductor single core cable (Polycab/ Finolex/ Anchor/ Salzer/ Havells Make) in existing surface/recessed Conduits (Including Cost of Conduit) laid in slabs with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified Anti-Bacterial Series ofHavells(Crab-Tree)/Legrand/L&T/Siemens/ABB/Equivalent Make & shall be approved before execution of work. |
| 3 | Supplying and Fixing of Indicator as required, ISO/IEC Certified Anti-Bacterial Series ofHavells(Crab-Tree)/Legrand/L&T/Siemens/ABB/Equivalent Make & shall be approved before execution of work. |
| 4 | Wiring for Fan point with (P+N) 2x1.5 sq.mm FRLS-H/HFFR PVC insulated Multi strand Copper conductor single core cable (Polycab/Finolex/Salzer/Anchor/Havells Make) in existing surface/recessed Conduits (Including Cost of Conduit) laid in slabs with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified Anti-Bacterial Series of Havells(Crab-Tree)/Legrand/L&T/Siemens/ABB/Equivalent Make & shall be approved before execution of work. |
| 5 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required,ISO/IEC Certified Anti-Bacterial Series ofHavells(Crab-Tree)/Legrand/L&T/Siemens/ABB/Equivalent Make & shall be approved before execution of work. |
| 6 | Wiring for Power Plug with (P+N+E) 2x 4 sq.mm FRLS-H/HFFR PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Polycab/Finolex/Anchor/Salzer/Havells Make) |
| 7 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified Anti-Bacterial Series ofHavells(Crab-Tree)/ Legrand/ L&T/ Siemens/ABB/Equivalent Make & shall be approved before execution of work.(Including Inverter Input/Output) |
| 8 | Wiring for 6Amp Plug(Computer Point) with (P+N) 2 x 2.5 sq.mm FRLS-H/HFFR PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Polycab/Finolex/Salzer/Paraflex Make) |
| 9 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Anti-Bacterial Series ofHavells(Crab-Tree)/Legrand/L&T/Siemens/ABB/Equivalent Make & shall be approved before execution of work. |
| 10 | Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS-H/HFFR PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Polycab/Anchor/Finolex/Salzer/Havells Make) & shall be approved before execution of work. |
| 11 | 2x6 sq.mm (P+N) for Heating Sub main in One run from Main Panel to Distribution Boards. |
| 12 | 2x4 sq.mm (P+N) for Lighting/Inverter Su Main in One run from switch boards to Distribution Boards. |
| 13 | 2x2.5 sq.mm (P+N) for Lighting/Inverter Circuit in One run from switch boards to Distribution Boards. |
| 14 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required of Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/ Schneider(Zencelo)/ABB/Equivalent Make |
| 15 | Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB . DB Complete with connections.(L&T/Siemens/Legrand/ABB /Schneider/BCH Make) |
| 16 | Supply/Fixing/Testing and Commissioning of Supplying and fixing following rating, double pole,(single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. (L&T/Siemens /Legrand/ABB/Schneider/BCH Make) |
| 17 | 40Amp. |
| 18 | 63Amp. |
| 19 | Supplying and Fixing of 8-Way single pole & neutral (SPN), sheet steel, Double Door Distribution Board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ ABB /Schneider/BCH Make) |
| 20 | Supply and fixing of 15 Watt LED Powder coated die cast/Extruded aluminum Body including trim with Aluminum Reflector(System lumen efficacy ≥ 120 lm/Watt ) Recess/surface mounted (Commercial type) downlighter having following specficafications .The luminaire should have a colour temperature of 6500°K, CRI≥80 and SDCM≤5. Luminaire shall be designed to emit initial system lumen output of greater than 2150 lumens .The downlighter shall be back-lit & not side-lit. The driver shall have THD≤10% (@full Load) and PF ≥ 0.95 (@full load). The luminaire housing /body should made of pressure die-cast aluminum. The fixture should comply with the parameters as per IS10322. The luminaire shall have impact resistance of IK02 & ingress protection of IP20. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, \\"FAT\\" before dispatch as per IS 10322 & IK Test. The luminary shall have average life of 50000 hrs operating temperature -10 C to + 45 C The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material. The LED Luminaire should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab & BIS certificate for LED Luminaire & Driver. The Agency / firm must submit the Technical data sheet (TDS) on OEM letter head along with requisite certificates for approval by an officer from the department not below the rank of SDO ,prior to the supply of materials. The Job includes 2-years replacement warrenty from OEM for the entire lighting fixtures from the the date of sucessful handing over of site to intending department , covering any damage /mulfunctioning /burnt out what so ever reason. Approved Make: Jaquar/Halonix/Surya/Equivalent make to be approved by EIC |
| 21 | Supply/Installation/Testing and Commissioning of upto 400mm Shutter Typed,320 Cu.m/Hr.AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB o including connection etc USHA/Anchor/Polycab/Orient/Halonix Make. |
| 22 | Supply/installation/testing and commissioning of CPRI-approved panel Wall/floor-mounted compartmentalized, 230 volts TDP MCCB Main Distribution panels, fabricated out of sheet steel of 16 gauge dust-protected, painted incl earth terminal with all necessary accessories as required for panel with internal wiring of panel.The Panel is to be provided and fitted with the following adjustable-type controlling/protection switchgear devices:1. Normal Incoming:100 Amp DP MCCB with breaking capacity of 16-36 KA with extended thimbles of Legrand/Siemens/ABB/LK make = 1 No.,200 Amp Bus bar Al Strips(P+N) = 1 Set, MultiFunctional Meter =1 No., phase indicator =1 No.Outgoing:(1) 63 Amp DP MCB (10 KA) of Legrand/Siemens/ ABB/Schinder /L&T make = 01No for normal heating sub main(2) 40 Amp DP MCB (10 KA) of Legrand/Siemens/ ABB/Schinder /L&T make = 01 No for Sub main lighting/ACs(3) 32 Amp DP MCB (10 KA) of Legrand/Siemens/ ABB/Schinder /L&T make = 01 No for Sub main invertorThe Panel manufacturing unit should be CPRI Registered and the Contractor has to submit the test certificate of main switch gear and Drawing of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards) is to be approved by Engineer Incharge before manufacturing. |
| 23 | Supply/Laying/Testing and Commissioning of 2- Core 16 mm sq. Al armored XLPE Insulated,PVC cable Havells/Polycab/RR Kabel/Paramount/KEI Make. Please Enable Macros to View BoQ information |