| 1 | Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in hard and dense soil complete all as specified and directed. |
| 2 | Earthwork excavation over areas with (soft/ disintergrated soil) not exceeding 1.5m in deep for foundation etc , and getting out complete all as specified and directed. |
| 3 | Earthwork excavation over areas with (soft/ disintergrated soil) exceeding 1.5m but not exceeding 3.0m in deep for foundation etc , and getting out complete all as specified and directed. |
| 4 | Excavation in trenches not exceeding 1.50 m wide and not exceeding 1.50 m depth for foundation and getting out in hard/dense soil complete all as specified and directed. |
| 5 | Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep and getting out in hard/dense soil for laying of UG cables or for errection of pole complete all as specified and directed. |
| 6 | Returning, filing in including spreading leveling, watering and well ramming in layers not exceeding 25 cm in hard / dense soil complete all as specified and directed. |
| 7 | Removal of surplus soil to a distance exceeding 5Km and not exceeding 15KM ouside the MD land including loading uploading etc.complete all as specified and directed.Note:- Palce of deposition and obtaining permission from local authorities etc in this regard shall be contractors responsibilty and the rate quated is inclusive of the Same. |
| 8 | Material & Labour Plain Cement Concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete all as specified and as directed. |
| 9 | Material & Labour Plain Cement Concrete (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in coping including weathering, slightly rounded or chamfered angles including necessary Use and waste of Form work complete all as specified and directed. |
| 10 | Material & Labour Plain Cement Concrete block masonry type C1 1:3:6 (20mm graded stone aggregate) exc 10 cm in width and setting in mortar 1:4 complete all as specified and directed. |
| 11 | Material & Labour for Plain Cement Concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete all as specified and as directed |
| 12 | Material & Labour Reinforced Cement Concrete M25 Design mix using 20mm graded aggregate in foundation, including rafts, footings, plinth beams, bases for columns etc and mass concrete complete all as specified and directed. |
| 13 | Material & Labour Reinforced Cement Concrete Design mix M25 using 20mm graded aggregate in columns above G.L complete all as specified and directed. |
| 14 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends etc complete all as specified and directed. |
| 15 | Material & Labour for precast reinforced concrete type B-1 1:2:4 (20mm graded aggregate) set in cement mortar 1:4 as in cover slabs complete all as specified and directed. |
| 16 | Material & Labour Form work to sides of Concrete foundation , footings, bases of columns, raft beams and soffits of foundation and plinth beam and similar work vertical or to batter etc with fair finished surfaces of concrete flat all complete all as specified and directed. |
| 17 | Material & Labour Formwork to sides of pillars, posts, struts, column etc rough finishes of concrete surfaces flat complete all as specified and directed. |
| 18 | Material & Labour for TMT bars for reinforcement 10mm dia and over cut to lengths, bent to shape required including cranking, bending etc and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 19 | Material & Labour for TMT bars for reinforcement 5mm and over upto and including 10mm dia TMT bars in stirrups, spaces and binders complete all as specified and directed. |
| 20 | Material & Labour for TMT bars 6mm to 8 mm dia cut to length bent to shape required including cranking bending and binding with MS wire not less than 0.90mm diacomplete all as specified and directed. |
| 21 | Material & Labour for round bars 10 mm dia and over for handles confirming to Fe 290 Gde E-165 complete all as specified and directed. |
| 22 | Material & Labour Tubular posts and struts, including lifting, erecting & positioning , cutting tops to shape as directed, drilling holes, all necessary drilling, bolting or riveting etc and similar work conforming to relevent IS complete all as specified and directed.NOTE : (Height upto 10m) Tubular section shall be of grade Yst 310 as per IS 1161 and plate Hot rolled section shall be of grade E350 conforming to IS 2062 and Hollow section shall be of grade Yst 310 conforming to IS 4923. All weld shall be Fillet weld (6mm size) all around , so as to ensure perfect Joints at all location of truss unless noted otherwise. All weld shall conform to IS 816-1969 |
| 23 | M & L for plates (Plain or chequired) channels, square cut, rounded or notched (Ordinary and counter sunk) as stiffners, bearing & end plates including forming holes, without any attachement inculding drilling, fixing with riveting, bolting or welding complete all as specified and directed.NOTE : (Height upto 10m) Plate Hot rolled section shall be of grade E350 conforming to IS 2062. All weld shall be Fillet weld (6mm size) all around , so as to ensure perfect Joints at all location of truss unless noted otherwise. All weld shall conform to IS 816-1969 |
| 24 | S & F Steel work in tubular trusses as in arch shape, any shape including special shaped washer etc. complete, connected to common rafters and running rails fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.NOTE : (Height upto 10m) Tubular section shall be of grade Yst 310 as per IS 1161 and Hollow section shall be of grade Yst 310 conforming to IS 4923. All weld shall be Fillet weld (6mm size) all around , so as to ensure perfect Joints at all location of truss unless noted otherwise. All weld shall conform to IS 816-1969 |
| 25 | S & F Steel tubular purlins / rafters including special shaped washer etc. complete, connected to truss, common rafters and running rails fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed. NOTE : (Height upto 10m) Tubular section shall be of grade Yst 310 as per IS 1161 and Hollow section shall be of grade Yst 310 conforming to IS 4923. All weld shall be Fillet weld (6mm size) all around , so as to ensure perfect Joints at all location of truss unless noted otherwise. All weld shall conform to IS 816-1969 |
| 26 | Material & Labour hot rolled sections as in framing for claddings, cleats, clamps for gutters, wind ties for roof including securing bolts , including lifting, erecting & positioning , including cutting tops to shape as directed, drilling holes, including all necessary drilling, bolting or riveting etc and similar work conforming to relevent IS complete all as specified and directed.NOTE : (Height upto 10m) Hot rolled section shall be of grade E350 conforming to IS 2062 and Hollow section shall be of grade Yst 310 conforming to IS 4923. All weld shall be Fillet weld (6mm size) all around , so as to ensure perfect Joints at all location of truss unless noted otherwise. All weld shall conform to IS 816-1969 |
| 27 | Supply & Fixing for Mild steel Anchor bolts purpose made of any length as specified with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut complete all as specified and directed. NOTE : (Height upto 10m) All bolts conforming to Grade 4.6 with relevent IS. |
| 28 | Supply & Fixing for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.63mm thick of an colour having tensile strength of 550 Mpa as in roof covering, bend to shape and fixed with self tapping screws complete all as specified and directed.Note : (Height upto 10m) Coated with super Durable paint system minimum galvanisation on shall be 200 GSM & Colour of sheet as specified by Engr in charge. |
| 29 | Supply & Fixing for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in cladding to wall, fixed with self tapping screws complete all as specified and directed.Note : (Height upto 10m) Coated with super Durable paint system minimum galvanisation on shall be 200 GSM & Colour of sheet as specified by Engr in charge. |
| 30 | Supply & Fixing for uPVC 150mm wide & 200mm depth Rainwater gutter pipe of required shape including end drops/ bends of UV coated, fix to roofing steel members with necessary runner joints, clamps/ screws fixed at any height complete all as specified and directed.Note : Colour of gutter as approved by Engr in charge. |
| 31 | Material & Labour for 100mm thick PCC 1:4:8 type D-1 using 20 mm graded stone aggregate as in floor/hard-standing/path/Plinth protection finished even and smooth without using extra cement complete all as specified and directed. |
| 32 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed. |
| 33 | Material & Labour Rendering 15 mm thick cement mortar (1:4) on fair surfaces of block masonry surfaces/concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 34 | Material and labour for two coats of synthetic enemal paint over a coat of red oxide primer on new steel surface including preparation of surface complete all as specified and directed. |
| 35 | Material & Labour for two coats for Painting lines, dashes, arrows, letters, etc. on pavements, play ground, roads and the like exc 10cm wide inclu ding preperation with road marking paint/ PU Painting, white or golden yellow all as specified and directed. |
| 36 | Supply & Fixing for 150 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed in wall/ floor with necessary clamping where required complete all as specified and directed. |
| 37 | Supply & Fixing for 150 mm dia PVC (SWR) bends any radius complete all as specified and directed. |
| 38 | Material & Labour for Point wiring for one light/Bell point controlled by one, one way switch complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through in and including 20mm dia PVC rigid non metallic conduit concealed with all accessories such as internal bend, end caps etc complete in walls and surface in ceiling/roof/etc including 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor including fabricated branded modular metal flush box concealed in walls with suitable modular plate with cover with suitable screws for housing switches, socket outlets, fan regulators etc all as specified and as directed. Note : (i) Modular metel boxes and cover plate measured and paid separately . |
| 39 | Material & Labour for Point wiring for one Ceiling/Exhaust Fan point controlled by one, one way switch complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through in and including 20mm dia PVC rigid non metallic conduit concealed with all accessories such as internal bend, end caps etc complete in walls and surface in ceiling/roof/etc including 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor including fabricated branded modular metal flush box concealed in walls with suitable modular plate with cover with suitable screws for housing switches, socket outlets, fan regulators etc all as specified and as directed. Note : (i) Modular metel boxes and cover plate measured and paid separately . |
| 40 | Material & Labour for Point wiring for one 05 Amps socket outlet point on same board, complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through in and including 20mm dia PVC rigid non metallic conduit concealed with all accessories such as internal bend, end caps etc complete in walls and surface in ceiling/roof/etc including 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor including fabricated branded modular metal flush box concealed in walls with suitable modular plate with cover with suitable screws for housing switches, socket outlets, fan regulators etc all as specified and as directed. Note : (i) Modular metel boxes and cover plate measured and paid separately . |
| 41 | Material & Labour for Point wiring for one switch socket outlet point 5 Amps on independent board, complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through in and including 20mm dia PVC rigid non metallic conduit concealed with all accessories such as internal bend, end caps etc complete in walls and surface in ceiling/roof/etc including 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor including fabricated branded modular metal flush box concealed in walls with suitable modular plate with cover with suitable screws for housing switches, socket outlets, fan regulators etc all as specified and as directed. Note : (i) Modular metel boxes and cover plate measured and paid separately . |
| 42 | Material & Labour for Point wiring for one 3 pin socket outlet, 15 Amps on independent board, complete with 2.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through in and including 20mm dia PVC rigid non metallic conduit concealed with all accessories such as internal bend, end caps etc complete in walls and surface in ceiling/roof/etc including 2.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor including fabricated branded modular metal flush box concealed in walls with suitable modular plate with cover with suitable screws for housing switches, socket outlets, fan regulators etc all as specified and as directed. Note : (i) Modular metel boxes and cover plate measured and paid separately. |
| 43 | Supply and fix Switch Modular 6A single pole, one way, 1 module complete all as specified and as directed. |
| 44 | Supply fix Switch Modular 16A single pole, one way, 1 module complete all as specified and as directed. |
| 45 | Supply and fix Socket, 6A - 2/3 pin combined 2 module, complete all as specified and as directed. |
| 46 | Supply and fix socket Modular 6/16A 2/3 pin combined 2 module, complete all as specified and as directed. |
| 47 | Supply and fixing LED high bay outdoor type lights fitting 1 x 100 watts, 220V,AC with in built driver, holder including LED lamp mounting hook and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 48 | Supply and fixing industrial air circulator wall mounted fan heavy duty 450 mm sweep 100 watts 1400 RPM approx air delivery 115 CFM including necessary fixing arrangement including welding drilling etc complete all as specified and directed |
| 49 | Supply and fix MCB DB, TPN 4 ways, double door, 240 volt, Isolated neutral bar with IP54 protection, door earthing arrangement with cement spill protector, mechanical impact strength IK09 complete all as specified and directed. |
| 50 | Supply and fix MCB SP 6 to 32 Amps, 240Volts, 10 KA, \\"B\\" Curve completeall as specified and directed. |
| 51 | Supply and fixing TPN 32 Amp rating 240 V, 10 KA 'C' curve miniature circuit breaker (MCB) complete all as specified and directed. |
| 52 | Material & Labour for framed brackets of angles or tees with web and falnges cut into shape, drilled/welded, screws, rivets and plates as per required size at site with handels etc in mild steel including two coat of paint over a coat of red oxide complete all as specified and directed. |
| 53 | Supply and fix ceiling rose surface type bakelite 65 x 50mm with three terminals complete all as specified and directed. |
| 54 | Material & Labour for earthing complete with GI earth plate electrode 600 x 600 x 6.3 mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to GI earth lead 4 mm dia mm by means of bolts, nuts, check nuts/bracing and washers all as shown in electrical plate No. 3 of SSR Part-I and including necessary excavation and earth work in any type of soil, removal and refilling of soil and funnel with wire mesh and GI watering pipe 20mm dia, Chamber in PCC 1:3:6, type C1 using 20mm graded stone aggregate and 40mm thick cover in RCC 1:2:4, type B1 using 20mm graded stone aggregate and reinforced with 8mm dia TMT bars at 150mm c/c on both ways, with flush type handle with 16mm dia round bars and 40 mm dia GI pipe upto 7.5m for protection and connected to earthing test point all as specified or indicated including testing on completion. Note :- (i) GI earth lead wire upto 7.5m shall be included in the quated rate (ii) PCC chamber shall be provided 50cm away from the plinth of building. (iii) Any damage in existing items during the time of excavation rectify/replace the same without any extracost. (iv) The porecline insulator reqd for fixing the earth conductor is deemed to included in quated rate (v) Soils only using for returing filling of earth pits if additional soils reqd provided by the contrcator without any extra cost.(vi) Earthpit chambers installed after compating the earthpits by using pooring of water etc |
| 55 | Supplyng and laying of XLPE insulated armoured heavey duty electric cable with aluminium conductor 1100 volts grade cross sectional area 10 sq mm 4 core all as directed. |
| 56 | Earth cushioning to UG cables using excavated soil riddled by using large sieve to separate the composite particles/roots etc and refilling in trenches complete all as specified and as directed. Note: Punned thickness only will be measured and paid. |
| 57 | Supply and lay burnt bricks sub-class 'B' designation 75 for cable protection all complete all as specified and as directed. |
| 58 | Dismantling / cutting of existing road / path / hard standing cement concrete (unreinforced) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) suitable for laying cable and protection pipe 80 / 50 mm dia under the road / path / hard standing complete all as specified and directed. |
| 59 | Material and labour for Plain Cement Concrete (1:2:4) type B-2 (using 40 mm graded crushed stone aggregate) for making good the disturbed surface of road/path/hard standing by using cement contrete mortar 1:2:4 type B1, using 40 mm graded stone aggregate 0.45 mtr wide and 0.15 mtr thick complete all as specified and directed. including demolition of old PCC and removing the debris from site complete all as specified and as directed at site by the Engr-in-Charge. |
| 60 | Supply and laying 50 mm dia tubes light grade galvanised with all fittings laid in trenches all as directed for cable protection |