| 1 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 2 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 3 | Excavation in foundation in ordinary soilb (loam, Clay, Sand) including lift up to 1.5 m and lead up to 30 m and filling watering and ramming of excavated earth in to the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the engg in chagre up to distance of 30 m from the foundation trenches Mannual . |
| 4 | PROVIDING AND LAYING PLAIN CEMENT CONCRETE IN 1:4:8 AND CURING COMPLETE ,INCLUDING COST OF FORM WORK IN FOUNDATION AND FLOORS |
| 5 | R.C.C.WORK PROVIDING AND LAYING IN POSITION 1:1.5:3 OF REINFORCED CEMENT CONCRETE IN FOOTING,COLUMN AND BEAMS EXCLUDING SHUTTERING AND REINFORCEMENT -ALL WORK UO TO PLINTH LEVEL. |
| 6 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) : |
| 7 | CENTERING AND SHUTTERING INCLUDING STRUTTING AND PROPPING FOR FOOTINGS AND BASES OF COLUMNS INCLUDING NAILS ETC.COMPLETE |
| 8 | CENTERING AND SHUTTERING INCLUDING STRUTTING AND PROPPING FOR BEAMS,SLABS OF ALL KIND INCLUDING ALL ETC. |
| 9 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 10 | CLASS-150(NON MODULAR) BRICK WORK IN 1:4 CEMENT AND COARSE SAND MORTAR ABOVE FOUNDATION AND PLITH UP TO FIVE FLOORS INCLUDING SUPPLY OF ALL MATERIALS,LABOUR AND T&P ETC.REQUIRED FOR PROPER COMPLETION OF THE WORK |
| 11 | 12 TO 15 MM CEMENT PLASTER WITH CEMENT MORTAR IN 1:4 CEMENT AND COARSE SAND OF SINGLE COAT FOR INTERIOR PLASTERING INCLUDING CURING ,SCAFFOLDING ETC COMPLETE |
| 12 | 6 MM THK PLASTERING WITH CEMENT MORTAR 1:3 IN FINE SAND IN FM NOT LESS THAN 1.25 AND CEMENT INCLUDING CHIPPING OF R C C SURFACE,BEFORE CEILING PLASTER INCLUDING ALL MATERIAL,LABOUR,T&P AND SCAFOLDING ETC COMPLETE |
| 13 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. (TMT Bars) Fe-500 DSR 5.22.6 |
| 14 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 15 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 16 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge,With average thickness of 120 mm and minimum thickness at khurra as 65 mm |
| 17 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) 25 mm thick |
| 18 | Providing and laying Ceramic glazed tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 19 | Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete. |
| 20 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 21 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 100 m spacing This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in ChargeConcealed work, including cutting chases and making good the walls etc (20mm dia) |
| 22 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 100 m spacing This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in ChargeConcealed work, including cutting chases and making good the walls etc (25mm dia) |
| 23 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 110 mm diameter |
| 24 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms |
| 25 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 26 | Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps andRange of two squatting plates with 5 litre P.V.C. automatic flushing cistern C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required : |
| 27 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 28 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A Multiple Agra Factor 111 (0.79617 |
| 29 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. Multiple Agra Factor 111 (0.79617 |
| 30 | Deduction of old brick |
| 31 | Deduction of old brick-bats of O.B.B./150 BB |
| 32 | Add GST 18% |
| 33 | Add rs. estemate figer amount Please Enable Macros to View BoQ information |