| 1 | B & R Division Items |
| 2 | Demolition of un-reinforced cement concrete in ground floor and paving not exceeding 15 cm thick (below or above ground level) complete all as specified and directed. |
| 3 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. and dispossing off complete all as specified and as directed. |
| 4 | Dismantling mild steel work or wrought iron of any description and in any position complete all as specified and as directed. |
| 5 | Dismantling plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding, etc.including all necessary staging / scaffolding, etc. as required complete all as specified and as directed. |
| 6 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing complete all as specified and as directed. |
| 7 | Taking down cement plaster on brick or stone walls etc, including raking out joints, hacking for key scrubing down with water, removal of rubbish off the premises, removal and depositing serviceable materials where directed and leaving the work clear of any plastering. etc complete all as specified and as directed. |
| 8 | Taking down chowkhats or frame with shutters (without taking off shutters from frame) each not exceeding 1.50 Sqm each complete all as specified. |
| 9 | Taking down Chowkats or frames with shutters exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from the frame) complete all as specified. |
| 10 | Surface dressing n exc 15 cm deep and getting out in soft / lose soil complete all as specified |
| 11 | M&L for Hardcore broken stone of gauge n exc 63mm deposited spread and levelled in layers n exc 15cm thick watered and rammed to a true surface complete all as specified and directed. |
| 12 | M&L for providing 150 mm thick plain cement concrete (1:4:8) type D-2 using (40mm graded stone aggregate) for Sub base floor rough surface complete all as specified. |
| 13 | M&L for providing 100 mm thick plain cement concrete (1:4:8) type D-2 using (40mm graded stone aggregate) for Sub base floor rough surface complete all as specified. |
| 14 | M & L for 75mm thick plain cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) as in plinth protection finished even and fair without using extra cement laid in panels and joints filled with bituminous mastic filling with 1 part of bitumen and 3 part of sand complete all as specified and directed. |
| 15 | Material and labour for 100mm thick Plain Cement Concrete type B-2 1:2:4 (40mm graded crushed stone aggregates) for sub base in floor fair and rough, path, hard standing etc including necessary formwork complete all as specified and directed. |
| 16 | M & L for plain cement concrete (1:2:4) type B1 using 20mm graded aggreagate as in bed blocks, coping , cills, steps, kneelers, bed plates, apex stones kerbs and similar works including necessary formwork complete all as specified and directed. |
| 17 | Material and labour for 25mm thick Plain Cement concrete type B-0 1:2:4 (12.50mm graded crushed stone aggregates) for sub base in floor levelling course, fair and rough complete all as specified and directed. |
| 18 | Material and labour for forming contraction ( dummy) joint 65mm deep X 10mm wide filled with sealing compound 'A' complete all as specified and directed. |
| 19 | Material and labour for forming expansion joint 12mm thick filled concrete slab thickness 100mm deep with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ complete all as specified and directed. |
| 20 | M & L for brickwork with subclass 'B' or locally available best quality old size bricks, straight or curved on plan exc 6 m mean raduis, built in CM (1:6) complete all as specified and directed. |
| 21 | M & L for half brick work in cement mortar (1:4) straight or curved on plan to any radius with locally available Subclass ‘B’ old size best quality bricks all as specified . |
| 22 | M & L rendering 10mm thick cement mortar (1:6) on other than fair faces of PCC block, brick wall or concrete surfaces, finished fair and even without using extra cement complete all as specified. |
| 23 | M & L rendering 15 mm thick cement mortar (1:4) in two layer each of 10+5 mm thick on fair faces of brick wall or concrete surfaces & water proofing compound @ 3% of wt mixed with second layer 5mm thick, finished fair and even complete all as specified. (Note :WPC measured separately). |
| 24 | Supply only integral water proofing compound WPC complete all as specified. |
| 25 | Material and labour Non-skid coloured ceramic glazed tiles 7 to 8 mm thick ( square/ rectangular) area of each tiles exc 0.18 sqm but not exc 0.38 sqm as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including 15 mm thick screed bed or bedding layers in cement mortar 1:6 over brushing with neat cement slurry as specified |
| 26 | Material and labour Non-skid coloured ceramic glazed tiles 7 to 8 mm thick ( square/ rectangular) area of each tiles exc 0.18 sqm but not exc 0.38 sqm as in vertical surfaces of skirting/ dado etc over 10 mm thick rendering in cm (1:4) as backing coat complete all as specified. |
| 27 | M&L Machine cut kota stone slab 20-25mm thick as in flooring laid over 20mm thick cement screed bed in cm 1 : 4 with cement slurry @ 4 kg/sqm jointed and pointed with grey cement slurry mixed with pigment to match the shade of slab including cutting and polishing to achieve mirror finish complete all as specified and as directed. |
| 28 | M&L Machine cut kota stone slab 20-25mm thick as in skirting over cement screed base laid over 20mm thick screed bed in cm 1 : 3 with cement slurry @ 4 kg/sqm jointed and pointed with grey cement slurry mixed with pigment to match the shade of slab including cutting and polishing to achieve mirror/granite finish complete all as specified and as directed. |
| 29 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed . |
| 30 | Supply and fix pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified. |
| 31 | Supply and fix pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified. |
| 32 | Supply and fix Framed work such as grills, gratings, etc.. with ends of bars or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 33 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z-sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge |
| 34 | Supply and fix as in repair stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified. |
| 35 | S&F 4.00 mm thick sheet glass ordinary quality and glazing with oil putting square nexc 0.5 sqm in each pane complete all as specified. |
| 36 | S&F 4.00 mm thick sheet glass ordinary quality and glazing with oil putting square exc 0.5 sqm in each pane complete all as specified. |
| 37 | S&F 100mm long Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed complete all as specified and directed. |
| 38 | S&F Mortice lock, vertical type size 100mm, of brass 04 levers vertical type complete all as specified. |
| 39 | Supply and fix 150 mm long aluminium handles cast type anodised complete all as specified & directed . |
| 40 | Supply and fix 200 mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 41 | S&F Door closer hydraulically regulated, designation No 1 universal type, aluminium (extracted body) suitable for door shutters of 851 to 1000 mm in width and weight of between 61 to 80 kg and fixed all as specified and directed. |
| 42 | M & L for preparation of new or previously untreated wall surfaces and applying three coats of white wash complete all as specified and directed. |
| 43 | Material & Labour for preparation of new plastered surface applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm using roller complete all as specified and directed. |
| 44 | M & L preparation of old steel surfaces of any description over 10cm width or girth not otherwise described and applying one coats of synthetic enamel paint complete all as specified and as directed. |
| 45 | E & M Division items |
| 46 | Taking down carefully copper/aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc including removing from site for taking credit and making good to disturbed surface of walls, floors etc as per existing specification complete all as specified and as directed. |
| 47 | Taking down carefully submain wiring including all accessories without disturbing existing wiring fittings fixtures etc and making good to the disturbed surfaces all as directed and as specified in any type and size all as directed. |
| 48 | Dismantling old unserviceable main switches, sheet metal enclosures DB including MCBs etc and removing from site for taking credit incl making good to disturbed surface of wall as per existing specification complete all as specified and as directed. |
| 49 | Dismantling of U/s GI pipe of size 40 mm/50mm bore complete all as specified and directed. |
| 50 | Taking out old U/s XLPE cable of any size/type taking out of old bricks/cable cover complete all as specified and directed. (Excavation and earth work will be measured and paid separately under respective items) |
| 51 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded FRLSH copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One light point controlled by one switch. |
| 52 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded FRLSH copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One fan point/exhaust fan point controlled by one, one way switch 5 Amp. |
| 53 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded FRLSH copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One 3 pin 5 Amp socket outlet point controlled by one switch on the same board. |
| 54 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded FRLSH copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One 3 pin 5 Amp socket outlet point controlled by one switch on independent board. |
| 55 | M & L for point wiring with FRLSH stranded copper conductor 2.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded FRLSH copper conductor 2.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for 3 pin, 15 Amp socket outlet, independent |
| 56 | M&L for point wiring with FRLSH stranded copper conductor 4.0 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded FRLSH copper conductor 4.0 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for one power point AC/Geyser equipments etc controlled by one SP/SPN MCB on independent board . Note: The point wiring will be done from DBs to the switch sockets of any size with three wires running independently for each point and with no tappings. |
| 57 | S&F switch piano flush type button single pole one way 5 Amps all as specified and directed. |
| 58 | S&F socket outlet 2 in 1, 3 pin 5 Amp flush type all as specified and directed. |
| 59 | S&F switch piano flush type button single pole one way 15 Amps all as specified and directed. |
| 60 | S&F Socket outlet 2 in 1, 3 pin, 5 and 15amp flush type all as specified and directed. |
| 61 | S&F ceiling rose surface bakelite with three terminals all as specified and directed |
| 62 | M & L for submain wiring with two single core 1.50 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including PVC non metallic rigid Conduit conceled with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 1.50 sqmm PVC insulated unsheathed multi strand copper conductor earth wire FRLSH connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed. Note: Two run of single core cable, one run earth wire and one run PVC Conduit will be measured as one length. |
| 63 | M & L for submain wiring with two single core 4.0 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including PVC non metallic rigid Conduit conceled with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 4.0 sqmm PVC insulated unsheathed multi strand copper conductor earth wire FRLSH connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed. Note: Two run of single core cable, one run earth wire and one run PVC Conduit will be measured as one length. |
| 64 | M & L for submain wiring with two single core 6.0 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including PVC non metallic rigid Conduit conceled with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 6.0 sqmm PVC insulated unsheathed multi strand copper conductor earth wire FRLSH connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed. Note: Two run of single core cable, one run earth wire and one run PVC Conduit will be measured as one length. |
| 65 | Supply & Fix LED betten plastic type fitting of capacity 20W, operating on 230V, 50Hz, AC Supply having luminous efficacy of not less than 125 lumens/watts, CCT 6500K, P.F>0.9, 2.5 KV surge protection, 4-feet long, housing made out of extruded alluminium with decorative end caps elegently designed complete all as specified. |
| 66 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type down lighter with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 67 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.. |
| 68 | Supply and fixing LED Bollards integral decorative luminaries with IP-65 Rated LED warm wight Bollard with robust design and efficient Each light distribution LED consuming 9/10 watt with opal acrylic diffuser including driver, fixing arrangement complete all as specified and directed by Engineer-in-Charge. |
| 69 | Supply and fix HOT moulded (FRP) jucntion box for street light pole with locking arrangementt with IP -65 protection of size 200x140x95 with 32 Amp 4 way heavy duty terminal block with 10 Amps MCB SP with two steel bracket to fix with pole complete all as specified and directed by Engr-in-charge. |
| 70 | S&F timelite distrubution board 32A, 3 pole, 230 volts Digital time switch complete all as specified and directed by Engr-in-charge.Make - Indoasian cat No. TL032DBO or L&T/Siemens or equivalent as approved list of make |
| 71 | S&F Rigid non metallic PVC conduit of dia 25 mm including of all Tee, bends, elbows, reducers, and fixing such as couplers lock nuts, saddles, pipe hooks etc complete all as specified and directed by Engineer-in-Charge |
| 72 | M&L Gl tube medium grade 50 mm bore length 6.5mtr with clamp, frame suitable for solar light pole complete all as specified and directed. Note: (i) Rate is inclusive of cost of excavtion, earth work & PCC for foundation. Excavation Size:- 0.3x0.3x0.8 mtr, foundation filling (0.3*0.3*0.8). Plain cement concrete 1:3:6 type C2 (40mm graded crushed stone aggregates) for foundation, PCC 1:3:6 type C-1 using 20mm graded stone aggregate for coping (0.15x0.15x0.15) of poles, Returning filling, Removing excavated materials to a distance not exceeding 50 metre and depositing where directed |
| 73 | Supply, install, commissioning and testing 40W solar street light designed with efficient mono crystalline solar PV module, Each Lithium ferro Phosphate battery with in built BMS technology, High efficiency LED, MPPT solar charge Controller, Aluminium Extruded body, intelligent control system which manage and maintains battery unit to provide longer life having IP 65 protection, The intelligent microwave sensor controls the dimming and brightness of light, efficientively extend the working time complete all as specified and as directed by Engineer-in-charge. Make-CROMPTON SONIVA PRO or Equivalent.Note- The Contractor have to submit warranty certificate of minimum 5 years for the solar lights. |
| 74 | S&F bldg security light, LED luminaire 30 watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07 including fixing arrangements complete all as per directed by Engr- in – charge. Make - Crompton Cat No LSTS-25-CDL/NL-M or equivalent as approved list of make |
| 75 | S&F Angle bracket 40mm dia for fixing building security light of 40mm dia of 1 mtr long bent to shape 45 degree for fixing of security light including MS clamps of suitable size including nuts, bolts complete all as specified and directed |
| 76 | S&F plastic body exhaust fan 250 mm sweep complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding and connecting to ceiling rose with flexible copper cable including making holes on the wall and making good to the disturbed surfaces including taking down of old UNSV one and depositing to MES storeyard for keeping in safe custody complete all as specified and as directed. |
| 77 | S&F BLDC ceiling fan 1200mm sweep complete with blades, down rods and accessories, 230 V, min air delivery 210 CFM with service value 6.00 BEE 5 star rated & provn of ‘S’ type fan hook including taking down of old UNSV one and depositing to MES storeyard for keeping in safe custody complete all as specified and directed. |
| 78 | S&F metal plug socket with MCB SP 20 Amp, 240 V enclosure for AC/equipment with neutral and earth point complete all as specified and directed. |
| 79 | S&F sheet metal enclosure powder coated SP single phase DB for fixing of MCBs, 8 way double door with copper bus bar 200 Amp including grouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed. |
| 80 | S&F MCB SPN of capacity 40-63 Amps, 240 V, 10 KA 'C' curve complete all as specified and directed. |
| 81 | S&F MCB SP of capacity 5-32 Amps, 240 V, 10 KA 'C' curve complete all as specified and directed. |
| 82 | Taking oout old existing earthing and M & L for new GI earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 25mmx4mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed. |
| 83 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 10 sqmm 4.0 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 84 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 10 sqmm 3.0 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 85 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 6 sqmm 4.0 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 86 | Material & labour GI tube light grade 40 mm bore for protection of cable complete all as specified and directed. |
| 87 | Supplying and laying of GI tube light grade 25 mm bore for protection of cable complete all as specified and directed. |
| 88 | M & L PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate for coping of poles including necessary fromwork complete all as specified and directed. |
| 89 | M & L 100mm thick PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate for flooring complete all as specified and directed. |
| 90 | Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed. |
| 91 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed. |
| 92 | Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed. |
| 93 | M & L for sand cushioning by spreading in trenches crushed sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge.Note : Thickness of sand cushioning after punning down will be measured. |
| 94 | M&L for bricks sub-class 'B' laid in trenches in flat style (width portion in horizontal shape) for cable protection complete all as specified and directed. Please Enable Macros to View BoQ information |