| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group C |
| 3 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 4 | Group C |
| 5 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 6 | 3 x 1.5 sq. mm |
| 7 | 3 x 2.5 sq. mm |
| 8 | 3 x 4 sq. mm |
| 9 | 3 x 6 sq. mm |
| 10 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 11 | 25 mm |
| 12 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 13 | 5/6 A switch |
| 14 | 3 pin 5/6 A socket outlet |
| 15 | 6 pin 15/16 A socket outlet |
| 16 | Bell push |
| 17 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 18 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 19 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 20 | 1 or 2 Module (75mmX75mm) |
| 21 | 4 Module (125mmX75mm) |
| 22 | 8 Module (125mmX125mm) |
| 23 | 12 Module (200mmX150mm) |
| 24 | Supply and laying of XLPE insulated PVC sheathed Aluminum conductor armoured cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended upto date) of the following size to be laid in the existing HDPE/DWC pipe as required. The job included labour charges of laying the cable and making connections etc. Make of cable:- Polycab/Havells/KEI/RR Kables |
| 25 | Size 25 sqmmx 3.5 core Armored |
| 26 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 27 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 28 | Supply and fixing of call bell buzzzer suitable for single phase 230 volt complete |
| 29 | Supply and erection of Modular type DP switch 32 Amp 250 Volt along with modular box, modular base and cover plat 2 module complete in all respect.Make Legrand (Lyncus)/ABB (Tvisha/ Gold Medal(GIFA) Crabtree (Athena) |
| 30 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 31 | 100/63 A,30KA,FPMCCB |
| 32 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 33 | 12 way , Double door |
| 34 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required. |
| 35 | Single pole |
| 36 | Single pole and neutral |
| 37 | Supplying and fixing single pole blanking plate in the existing MOB DB complete etc. as required. |
| 38 | Earthing withCopper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.70 metre long etc. with 96kg charcoal/ coke as required |
| 39 | Supplying and laying 25mm x 5mm Copper I strip at 0.50 metre below ground level as strip earth electrode , including connection/terminating with G.I nut ,bolt ,spring washer etc as required ( Jointing shall be done by overlapping and with 2 sets of Brass nut bolt & spring washers spaced at 50mm) |
| 40 | Supplying and fixing Batton Holder on the existing junction box/ wooden block including connections etc. as required. |
| 41 | Supply,erection,testing and commissioning of ceiling fans 1400mm sweep One star rating white color with copper winding but without regulator complete with aluminium blades, plastic canoples 2 nos, double ball bearing, MS hanging rods, etc. complete in all respect. The job includes Installation, testing and commissioning of ceiling fan, including wiring with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required upto adjacent light point complete in all resepect.Makes Havells-Velocity ES/Orient- Summer-Breeze Pro /Crompton-High Speed/Bajaj- SABSE TEZZ-EE only |
| 42 | Supply ,installation, testing and commissioning of recessed type LED panel 2'x 2',having CRCA housing duly painted with diffuser, minimum 4200 lumens (120 lumens/watt),5700K/6500K and 50000 burning hours of make Philips RC 380-B LED 42S-6500-G6/ Wipro CRCO10R036HE57G3 / Havells PLANO 2X2 PLR 36W LED865TAPS/Bajaj-BZRSQL43L-LEDGXPROWH.The job inculdes the cost of testing, commisisoning and making connection with 3*1.5 sq mm copper wire upto 1.5mt from adjacent light point, other petty material and labour etc as required to complete the same to the entire satisfaction of Engineer in Charge. |
| 43 | Supply ,installation, testing and commissioning of Surface type LED panel 2'x 2',having CRCA housing duly painted with diffuser, minimum 4200 lumens and 50000 burning hours of make Philips - SM365C LED 32-6500 PSUODWH/WIPRO-CRC 010SO0-38HP57GL1/ Havells-Piano suface 36W.The job inculdes the cost of testing, commisisoning and making connection with 3x1.5 sq mm copper wire from adjacent light point, other petty material and labour etc as required to complete the same to the entire satisfaction of Engineer in Charge. |
| 44 | Supply and errection of 1x20 watt 4' long LED box type fittings with decortative end caps of make Crompton CAT no. DMLNILT8-16+LT8-20-865-2 or equivalent models of make Philips/Surya make only .The LED tube rod 20 watt polycarbonate with inbuilt driver, extruded aluminium heat sink, 30000 burning hours at 70% lumens maintenance of makes Philips/Havells/Wipro/Crompton/Bajaj. The job includes carriage, erection, making connections with 3x1.5 sq.mm copper wire from adjacent light point, testing and commissioning of the fittings etc. as requried to complete the same to the entire satisfaction of engineer in charge. |
| 45 | Supply and erection of fan rod made of seemless MS pipe dia duly powder coated complete in all respect. Make National |
| 46 | 60\\" length |
| 47 | Supply and erection of Modular type DP switch 32 Amp 250 Volt along with modular box, modular base and cover plat 2 module complete in all respect.Make Legrand (Lyncus)/ABB (Tvisha/ Gold Medal(GIFA) Crabtree (Athena) |
| 48 | Supply and fixing of MCB TPN 63 amp rating, 415V, 10KA\\"C\\" curve miniature circuit breaker suitable for inductive load of following poles in the existing DB complete with connections, testing and commissioning as required.Makes Havels/ABB/L&T/Schnieder |
| 49 | Providing and fixing of MS 10mm dia U type fan hook which includes fixing in the steel bar of RCC slab and repairing the same in good condition. |
| 50 | Supplying and fixing of Surface/recess mounting 8 way TP &N vertical load line distribution board double door steel, dust protected, duly powder coating inclusive of tinned copper bus bars,160Amp (W/o MCCB) and outgoing MCB's (Without MCB's) complete in with all petty material and labour required.Makes Havels/ABB/Schnieder |
| 51 | Supply and fixing of 40 amp rating, 415V, 10KA\\"C\\" curve Single pole & Neutral miniature circuit breaker suitable for inductive load in the existing DB complete with connections, testing and commissioning as required.Makes Havels/ABB/Schnieder |
| 52 | Supplying and fixing of suitable size GI box with modular plate and cover 12 modules in front on surface or in recess, including providing and fixing 4 nos 5/6 A modular switch, 3 nos 5/6 A modular socket outlet and one 10 AMP international socket, with necessary connections etc. as required. (for computer plugs to be used in non residential buildings.) |
| 53 | Disconnection of existing Single/three phase , cable connections/ circuits of existing Distribution boards e & irespective of number of circuits and reconnctions in new Distributon boards conmplete in all respect to make the supply functional. Please Enable Macros to View BoQ information |