| 1 | SCH 'A' PART-I (B/R WORK)Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as per specified and as directed. |
| 2 | Demolition of unreinforced cement concrete in ground floors and pavings nexc 15 cm thickness (below or above ground level) complete all as per specified and as directed. |
| 3 | Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as per specified and as directed. |
| 4 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation board/Slabs/blankets of any thickness including cover fillets, complete all as per specified and as directed. |
| 5 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises , complete all as per specified and as directed. |
| 6 | Taking down cement plaster on brick wall of any description, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed. |
| 7 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as per specified and as directed. |
| 8 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) exceeding 1.5 Sqm but not exceeding 4 Sqm each and removing from site, complete all as per specified and as directed. |
| 9 | Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as per specified and as directed. |
| 10 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for taking out, excavated earth,forming bottom surfaces etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.Note:- Excavation shall be made carefully to avoid damage of existing cables and brick protection. Existing bricks/precast concrete cable over shall be taken out, stagged for reuse as directed. |
| 11 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in hard/dense soil, complete all as per specified and as directed. |
| 12 | Removing excavated soil material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed. |
| 13 | M&L for plain cement concrete type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in surface channels and drains, complete all as per specified and as directed. |
| 14 | M&L for providing plain cement concrete type C-1, 1:3:6, (using 20 mm graded stone aggregate), as in copings, bed block for filing hollow space of steel chowkhats, fixing of hold fast, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work, complete all as per specified and as directed. |
| 15 | Supply only Liquid water proofing compound confirming to IS , complete all as per specified and as directed. |
| 16 | M&L for fly ash brick work, straight or curved on plan exc. 6m mean radius in cement mortar 1:6, complete all as per specified and as directed. |
| 17 | S&F of 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as per specified and as directed. |
| 18 | S & F powder coated aluminium window sliding type three track (2 glazes and one gage shutter ) aluminium sections weighing not less than 1.67 kg/m for frame and 0.55 kg/m for shutter including necessary jointing cleats, glazing cleats, rubber packing, screws,handle,locking arrangement and 4 mm thick plain/tinted glass and aluminium mosquito proof gauge including taking down of old existing steel window and making good disturbed surface of well complete all as per specified and as directed. |
| 19 | M & L for providing & fixing factory made solid PVC cup board frame size 50 mm X 47 mm (suitable for two track sliding type sshutters) with wall thickness of 5 mm made out of extrude 5 mm thick prelm/plain colour PVC sheet rainforced with 19 mm x 19 mm MS squer tube of 19 gauge thickness throughout the frame and meter cut at two corners and jointed with 2 nos of 150 mm long brackets of 15 mm x 15 mm MS ssquer tubes. the door frame shall be fixed to the wall using 100 mm long MS screws through the frame by using PVC fasteners. A minimum 4 nos of screws to be provided to the horizontal member etc.complete all as per specified and as directed. including dismantling existing of cupboard |
| 20 | M & L for providing & fixing factory made solid PVC(two track sliding type) cup board shuutter (flush type) of 24 mm thick mad from co-extruded 3 layer regid PVC foam sheet (single extruded) with density not less than 600 kg /cbm outer layer (0.8 - 1.00 mm) thick should be of rigid PVC with density 1400 kg/cbm manufactured byan ISO 9001-2015 certified company. Door should be water proof, turmite proof, fire retardant and having good screw holding capacity , with all sliding and locking arrangement complete all as per specified and as directed, including taking down the existing cupboard. |
| 21 | Supply and fixing of factory made partly glazed i.e. upper panel will be wire mesh fitted externally in the clear space & lower panel will be plain colour PVC sheet 5mm thick PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail,; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, complete all as per specified and as directed. |
| 22 | S&F of providing and fixing factory made PVC shelf/ partition of required size consisting of 20mm thick Solid PVC Sandwich Panel with 1mm Plain PVC Sheet on both sides suitably fixed in M.S. angle frame work as per specification & drawing, complete all as per specified and as directed. |
| 23 | S&F of 100 mm butt hinges, medium weight, cold rolled mild steel and fixed , complete all as per specified and as directed. |
| 24 | S&F of 200 mm long aluminium, anodised, barrel tower bolts of extruded section, complete all as per specified and as directed. |
| 25 | S&F of 150 mm long aluminium handles, cast type, anodised, complete all as specified and as directed. |
| 26 | S&F of 300 mm long mild aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as per specified and as directed. |
| 27 | M & L for 75 mm Hasp and staple, mild steel, safety type, of aluminiumanodised ,stove enamelled black, including bolt to hinge plate and fixed with screws, complete all as per specified and as directed. |
| 28 | S&F in repair of Harrison rails curtain rod, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as per specified and as directed. |
| 29 | S&F of floor door stopper with overall length of cover plate 140 mm long of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor, complete all as per specified and as directed. |
| 30 | S & F Stainless steel wire cloth, 0.36 mm dia of wire and average width of aperture 1.40 mm and fixed with tinned stacks, or galvanized wire staples complete all as per specified and as directed. |
| 31 | M&L for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed . |
| 32 | S&F Pressed steel frames of size 125x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete all as per specified and as directed. |
| 33 | S & F Anodised aluminium snap grid frame work for false ceiling Size of grid 605 x 605mm complete all as per specified and as directed. |
| 34 | S & F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified complete all as per specified and as directed. |
| 35 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated or semi-corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws or J hooks, complete all as per specified and as directed. |
| 36 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws or J hooks, complete all as per specified and as directed. |
| 37 | M&L for 4mm thick non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws fixed in ceiling flat or sloping, complete all as per specified and as directed. Please Enable Macros to View BoQ information |
| 38 | M&L for 4mm thick non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws fixed in ceiling flat or sloping, complete all as per specified and as directed. Please Enable Macros to View BoQ information |