| 1 | Providing and laying poly vinyal chloride (PVC) rolls of 1.5m / 2.00 mtr width manufactured by approved pattern/colour and design for flooring, skirting/dado/ laid or existing smooth cement tile or concrete of plastered finish with suitable adhesive as per manufacturers specifications close jointed and finished to proper bends, slopes and plumbs as directed etc. complete including making leveling existing surface with POP & adhesive to make surface proper laying generally as per manufacturer’s specifications. PVC approved make , approval by Engg-in-charge. |
| 2 | 2mm thck PVC flooring |
| 3 | Providing and fixing cabinet made up of 19 mm. Commercial ply of approved make for top, bottom, sides and shelves and 6mm commercial ply approved make for back side.Door shutter made up of 19mm thick commercial ply and outer surfaces and top of shelves for open type cabine should be laminated with 1.0mm thick approved plastic laminate sheet of required colour including all brass fittings such as hinges, tower bolts, ball catches, stopper, handle, knobs as per shown in drawing or approved by Engineer-In-Charge etc.and all exposed edges lipping with 6mm laminate finish Thick T.W.lipping patti.locking arrangement with Godrej multipurpose lock etc. All inside areas shall be .80mm thick approved colour laminate etc.all complete as specified and directed by Engineer-In-Charge. |
| 4 | With inner side 0.8mm thick laminateWith shutter |
| 5 | Drawer Unit Below Table :-Providing making fully drawer storage unit made up of 19mm thick commercial plywood with heavy duty sliding channel & with 6mm thick commercial plywood for back , 19mm plywood for top,bottom, shelves drawer front etc. side of drawer to be of 12mm thick & bottom to be as per requirement & bottom to be as per requirement. 1.0mm thick approved laminate to be fixed over exposed surfaces of the unit & non laminated area to be 0.80 mm thick laminate of white / off white. Hardware items such as lock, hinges tower bolt, handle to be of heavy duty & approved make only. a) Fixed type drawer unitb) Moveble type drawer unit |
| 6 | Providing making and supplying computer table made out of19mm commercial ply for table top, mounted on the vertical side of 19mm thick approved make drawer unit will be cabinet commercial ply and made out of 19mm commercial ply for sides, shelves and shutters or drawers with heavy duty sliding channel shown in drawing ready mode key board drawer with heavy sliding channels, all edges shall be lipped with 6mm thick T.W. lipping patti or are edge beeding matering with laminate. All exposed faces should be 1.0mm thick laminate of approved colour and non laminated area should be 0.80 mm thick white / off white laminate including cost of other materials labour etc. as per drawing and as specified and directed by Engineer-In-Charge. |
| 7 | Computer table with all inner surface with 0.8 mm thick approved laminate |
| 8 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 9 | 1mm thick with zinc coating not less than 275 gm/m² |
| 10 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 11 | G.S. Sheet |
| 12 | PVC GUTTER :Providing & fixing 6” dia half round PVC rain water gutter including necessary M.S. / PVC brackets at every 1.00 mtr. Intervals fixing to the existing truss members by providing necessary funnels for rain water down takes etc. complete all as specified & directed by engineer in charge |
| 13 | Removing existing false ceiling of any material and any size with all necessary allied works including disposal of unservicable material as directed by Engineer in Charge. |
| 14 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 15 | Hot finished welded type tubes |
| 16 | Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondaryintermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require,fixed with Glavanised iron perimeter wall angle or size 4x24x0.40 mm of length 3000 mm to be fixed on periphey wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The workshall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 17 | PAINTING WORKProviding & applying one / two coats of primer two coats of paint as mentioned below of approved make First quality Asian Paints (Apcolite) / Nerolac / Dulux to the required colour scheme and as per manufacturers instructions / specifications to the walls, beams, columns, ceilings, partitions, doors etc. including removing existing paints , nails , screws , battens etc. and thoroughly scrapping the surface with sand papers filling up crevices and levelling with putty of Asian make necessary to obtain smooth surface ie. complete surface preparation etc. complete as directed to the entire satisfaction of Engineer In-charge.With two coats of primer and two coats of paint |
| 18 | Using Luster paint |
| 19 | Using synthetic enamel paint (Oil Paint) |
| 20 | POINT WIRING :- Point wiring for light/fan/bell with ISI mark 3 x 1.5 sq.mm (P+N+E). FRLS PVC insulated copper conductor of Polycab / RRK /Finolex in surface/ recessed heavy class pvc casing capping/conduit of Presto-plast/sunwood /Precision make with Modular switch of Legrand-Myrius/MK-Blenze & Anchor make-ceiling rose/batten holder/slanting holder Boxes etc. with circuit labling/marking/ferruling complete. |
| 21 | Primary point upto 4 mtrs length |
| 22 | Primary point length 4 mtrs to 7 mtrs |
| 23 | Primary point length 7 mtrs to 10 mtrs |
| 24 | Secondary point Extending from Primary point upto 4 m |
| 25 | Half point on same board with 5A S/W and 5A Socket. |
| 26 | Dismantling of Electrical Accessories :- Providing qualified Wireman and a helper with tools for carrying out dismantling the existing light, fan, bell, independent plug point wiring of all types with accessories and cable /switchgear in an approved manner as per instruction of Engineer Incharge and handing over the removed material to Engineering Dept by making detailed list. |
| 27 | Bell Indicator with Buzzer - 240V with back box and necessary interconnections. |
| 28 | Blank plate -1 module |
| 29 | Supply & installation of surface Board Legrand-Myrius/MK-Blenze (inclusive of back box, surface plate & wiring) |
| 30 | 6Amp Switch&Socket |
| 31 | 6A socket-2 nos+6A switch 2 nos |
| 32 | 6A socket-3 nos+20A switch with indicator |
| 33 | 16Amp Socket + 16A Switch with Indicator |
| 34 | Telephone Outlet with telephone I/O, back box and face plate in all respect (without telephone wire) |
| 35 | Supplying and fixing on wall PVC sun wood /prestplast heavy duty boards of following size |
| 36 | 4inch x 7inch |
| 37 | SUB MAINS Mains :- Providing Heavy duty PVC casing-caping/conduit of Precision make. Supplying and erecting mains with copper conductor PVC insulated FRLS of 1100 V AC grade Polycab/RRK/Finolex make wire with circuit labling/marking/ferruling and lugs at both ends complete. |
| 38 | 2 x 1.5 sq mm -+ 1.5sqmm Earth wire |
| 39 | 2 x 2.5 sq mm -+ 1.5sqmm Earth wire |
| 40 | 2 x 4 sq mm -+ 2.5 sqmm Earth wire |
| 41 | Supply and Fixing Rigid PVC conduit Medium Mechanical Stress (MMS) with all fitting & fixing accessories Precision make |
| 42 | 25 mm |
| 43 | Supply and Fixing PVC Flexible Conduits Poly Proplyne (PP) with all fitting & fixing accessories Precision make |
| 44 | 25 mm |
| 45 | Supply and Fixing PVC Casing Caping with all fitting & fixing accessories Precision make |
| 46 | 1inch dia 25mm x 16mm |
| 47 | Supply and Fixing of PVC Trunking /covering of following sizes |
| 48 | 100 x 50 mm PVC trunking |
| 49 | PVC/XLPE CABLE Copper :- Armoured cables - supplying, laying, testing and commissioning of 1100 V AC grade PVC FRLS insulated ISI mark Poly- cab/RRK/Finolex Copper Conductor cable erected on wall,ceiling,column etc with appropriate size of GI spacers & saddlers screws etc complete in approved manner of following size . . |
| 50 | 3 x 2.5 sq mm copper |
| 51 | 3 x 4 sq mm copper |
| 52 | PVC/XLPE CABLE Aluminium :-Supplying, erecting, testing and commissioning of 1100 V AC PVC FRLS armoured 3 1/2 core Aluminium Conductor cable of Polycab/RRK/Finolex make erected on wall/beam/ceiling/shaft etc with appropriate size, along with saddlers,spacers complete with approved manner of following size . . |
| 53 | 2 x 1.5 sq mm copper (Red color for Fire alarm system) |
| 54 | 3 1/2 x 25 sq mm |
| 55 | Cable Glands - Double Compression with Termination:- Supplying and erecting heavy duty flange type brass cable glands for armoured cable with brass washers,rubber rings complete erected with cable ends & leads connected with proper size lugs.Make Comet/Braco/Dowells. |
| 56 | 2 to 4 core 2.5/4/ 6 sq mm |
| 57 | 3 to 4 core 25-50 sq mm |
| 58 | Earthing :- Supplying,installation of copper strip /bare wire of earthing system on wall /slab/column/beam along with clips etc including end connections with crimping type copper lugs complete in all respected and as directed by Eng-in-charge |
| 59 | 14 SWG copper bare wire |
| 60 | LIGHT Fixtures:- Supply,installation,testing and commissioning of fixtures on wall/beam/slab by means of bracket ,anchor fastener suspended from slab/beam by means of 19 mm dia conduit pipe/down road,ball and socket arrangement,flexible twisted wire/ flexible cable connection etc and GI chain for recessed mounting fitting complete in all respect as directed by Engg. in charge and Philiphs make or any other approved make as per instructions of EIC. |
| 61 | Batten 4ft for LED tube Philips/Wipro/Crompton/Osram/Bajaj make.(As Approved by EIC) with Tube |
| 62 | Light fixture ultra slim LED panel Square 15W IP20 6500K Philips make |
| 63 | Energy Efficient Ceiling Fans -Supply, fixing & commissioning ceiling fan white/brown coloured including Safety Chain for Ceiling Fans for providing secondary support and heavy gauge down rod as per site condition. Atomberg EFFICIO make. |
| 64 | Size 900mm |
| 65 | Size 1050mm |
| 66 | FAN HOOK |
| 67 | Double anchor fastener heavy duty with GI clamps |
| 68 | Supply fixing down rod of GI class 'B' pipe of (inner dia - 16mm, outer dia - 20mm & 2mm thickness) with threading,boring etc with necessory hardware & accessories for ceiling fans. |
| 69 | Distribution Boards Supply, installation, testing & commissioning DBs for mounting MCB/ELCB/Isolator - on wall complete. |
| 70 | SPN 12 way IP 43 with Metal door |
| 71 | TPN 4 way IP 43 with Metal door |
| 72 | SITC of Legrand DX3 make AC C Curve MCB of following sizes in provided enclosure and connected with leads on incoming and outgoing side duly completed in approved manner. |
| 73 | 6 to 32 A SP MCB 10 KA |
| 74 | 40 to 63 A 4 P MCB 10 KA |
| 75 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 76 | Providing ,fixing and commissioning of Legrand DX3 make RCBO |
| 77 | 16A/25A DP - 30 mA |
| 78 | Cable end box for IP 43 DBs |
| 79 | SPN 12WAY DB |
| 80 | SPN 4WAY DB |
| 81 | Telephone Wiring :- Supplying and laying 0.5 mm gauge unarmoured telephone wire D.O.T approved, make Dlink/Finolex/Digilink/Polycab through exisitng conduit/casing caping/cable tray. |
| 82 | 2 Pair |
| 83 | 20 pair telephone cable |
| 84 | Supply, Installation, of crone connector tag block (Make-Krone) in Powder coated sr metal box. |
| 85 | 2 x 20 ways tag block |
| 86 | S&C hylam sheet of 3 mm thick to be used for covering MS boxes etc including cutting,drilling,fixing with nut bolts/ screws cup washers etc complete as required and to the satisfaction of incharge with making necessary groove/ cutting for fixing electrical accessories. |
| 87 | SITC of Telephone intrument Panasonic KX-TS-500 Black Color with all necessary accessories with fixing arrangements as per site conditions and as per instructions of EIC. |
| 88 | SITC of Split AC's 2 TR Inverter 5 star Including Std 3 mtr.Copper piping, cable and drain piping. Units should be with 100% Copper condenser and copper evaporator coils. Should work at 52 degree Ambient Temp.Make - Mitsubishi, Daikin, Voltas. |
| 89 | SITC of extra copper piping supply and return pipe with insulation for 2TR split AC. |
| 90 | SITC of flexible 3C x 2.5 sq mm flexible cable.Make- Polycab/RRK/Finolex |
| 91 | Supply and Installation of 5 mm wall thickness PVC drain piping for Split AC with all fittings and supports, saddle, pressure clamps etc.Pipe size- 32 Dia |
| 92 | Supply and fixing rigid PVC conduit Medium Mechanical Stress (MMS) with all fitting & fixing accessories precision make. (100 x 50mm PVC trunking (1.2mm thickness) |
| 93 | Removing of Old split Acs (including indoor & outdoor by pumping down) |
| 94 | Supply, Installation & Testing andCommissioning of following:Cat - 6 copper cable, Systimax in existing conduit / Trunking |
| 95 | 24 port jack panel for CAT - 6 Systimax |
| 96 | I/O for CAT - 6 Systimax |
| 97 | Dual face plate for MS Concealed box |
| 98 | Single face plate for MS Concealed box |
| 99 | Supply and Fixing Rigid PVC conduit Medium Mechanical Stress (MMS)with all fitting & fixing accessories Precision make40 mm |
| 100 | Supply and Fixing PVC Flexible Conduits Fire Retardant Poly Proplyne(FRPP) with all fitting & fixing accessories Precision make40 mm |
| 101 | Supply and Fixing PVC Casing Caping with all fitting & fixing accessoriesPrecision make |
| 102 | 25mm x 12mm |
| 103 | 25mm x 16mm |
| 104 | 38 x 25 mm PVC trunking Please Enable Macros to View BoQ information |