| 1 | Brick work will well burnt open bhatta bricks crushing strength not less than25kg/cm² and water absoption not more than 20% in foundation and plinthIn cm 1:6. |
| 2 | Providing and laying in position specified grade reinforced cement convrete excluding the cost of centering and shuttering, finishing and reinforcement - All work up to plinth level. Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate |
| 3 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated Bars |
| 4 | Centering and shuttering including strutting, propping etc.and removal of form for : Foundations, footings, bases of columns, etc. For mass concrete. |
| 5 | 18mmcementplasterintwocoatsunderlayer12mmthickcementplaster1:5(1cement:5coarsesand)finishedwithatoplayer6mmthick cement plaster 1:4 (1 cement: 4 fine sand). |
| 6 | 6 mm cement plaster of mix : 1:3 (1 cement: 3 fine sand) |
| 7 | Wallpaintingwithplasticemulsionpaintofapprovedbrandandmanufacture to give an even shade: Two or more coats on new work |
| 8 | Distemperingwith1stqualityacrylicdistemper(readymixed)ofapprovedmanufacturer,ofrequiredshadeandcolourcomplete,aspermanufacturer's specification. Two or more coats on new work. |
| 9 | PaintingSteelworkwithDeluxeMultiSurfacePainttogiveanevenshade.Twoormorecoatapplied@0.90ltr/10sqmoveranundercoatof primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture |
| 10 | Providingandlayingvitrifiedfloortiles(withoutSolublesalt)orprinted(withsolublesalt)Nanopolished(Glossyfinish)indifferentsizeswithwaterabsorptionlessthan0.05%andconformingtoIS:15622ofapprovedmakeinallcolours&shades,Istquality/premiumqualityinflooringlaidon20mmthickcementmortar1:4(1cement:4sand)includinggroutingthejointswithwhitecementandmatchingpigmentsetc. complete. Size 600x600mm as per manufacturer specification. |
| 11 | Structural steel work riveted, bolted or welded in built upsections, trusses and framed work, including cutting, hoisting, fixingin position and applying a priming coat of approved steel primer allcomplete: |
| 12 | Providing and laying below ground unplasticised PVC pipe to withstand working pressure of 4 kg/cm2 soild waste pipes confirming toIS:13592 and IS:4985 including jointing with seal ring confirming toIS :5282 leaving 10mm gap for thermal expansion all necessaryfittings etc. complete. Excavation to be paid seperataly 110 mm diameter OD |
| 13 | Providingandfixingaluminiumworkfordoors,windows,ventilatorsandpartitionswithextrudedbuiltupstandardtubularsections/appropriateZsectionsandothersectionsofapprovedmakeconformingtoIS:733andIS:1285,fixedwithrawlplugsandscrewsorwithfixingclips,orwithexpansionholdfastenersincludingnecessaryfillingupofgapsatjunctions,attop,bottomandsideswithrequiredPVC/neoprenefeltetc.Aluminiumsectionsshallbesmooth,rustfree,straight,mitredandjointedmechanicallywhereverrequiredincludingcleatangle,Aluminiumsnapbeadingforglazing/paneling,C.P.brass/stainlesssteelscrews,allcompleteasperarchitecturaldrawingsandthedirectionsofEngineer-in-charge.(Glazingandpanelingtobepaidforseparately) : For fixed portion Anodisedaluminium(anodisedtransparentordyedtorequiredshadeaccordingtoIS:1868,MinimumanodiccoatingofgradeAC15) |
| 14 | Forshuttersofdoors,windows&ventilatorsincludingprovidingandfixinghinges/pivotsandmakingprovisionforfixingoffittingswhereverrequiredincludingthecostofPVC/neoprenegasketrequired (Fittings shall be paid for separately). Anodisedaluminium(anodisedtransparentordyedtorequiredshadeaccordingtoIS:1868,MinimumanodiccoatingofgradeAC15) |
| 15 | Providingandfixingglazinginaluminiumdoor,window,ventilatorshuttersandpartitionsetc.withEPDMRubberneoprenegasketetc.completeasperthearchitecturaldrawingsandthedirectionsofengineer-in-charge(Costofaluminiumsnapbeadingshall be paid in basic item): With float glass panes of 4.0 mm thickness |
| 16 | Provision for all type of Electrification work as per sor complete direction of engineer in charge. Please Enable Macros to View BoQ information |