| 1 | Construction of Non-Residential Buildings of Thana Sachendi at Commissionerate District-Kanpur Nagar (U.P.) |
| 2 | POLICE STATIONSurface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-incharge..All kinds of soil. |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. |
| 5 | Carriage of surplus excavated earth including loading, unloading and staking up to 50 mtr. |
| 6 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 7 | Providind and lying1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 8 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concreteAll works upto plinth levelConcrete of M25 grade with minimum cement content of 330 kg /cum |
| 9 | All works above plinth level upto floor V levelConcrete of M25 grade with minimum cement content of 330 kg /cum |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 14 | Weather shed chajja, corbals etc including edges |
| 15 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 16 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 17 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 18 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) : With F.P.S.(non modular) bricks |
| 19 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement :3 coarse sand) |
| 20 | Providing and fixing 18 mm thick Granite (gang saw cut) mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble Area of slab over 0.50 sqm |
| 21 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Marble work Marble work |
| 22 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 23 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy,bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 24 | Supply & fixing of flush doors commercial quality conforming to IS 2202 Part 1 (1983) including fixing of wooden cleats and stoppers and including fixing and adjustment of hinges bolts locks handles springs fitting with necessary screws to be supplied departmentally.Bothi side lamenated(a) 35mm thick Single leaf 30 mm thick shutters |
| 25 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 26 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube |
| 27 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces |
| 28 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg. |
| 29 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Double charge vitrified tile polished finish of sizeSize of Tile 600x600 mm |
| 30 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 31 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 32 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) |
| 33 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) |
| 34 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 35 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 36 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour Two coatS |
| 37 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : for door Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 38 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural dra wings and the directions of engineer-in-charge . With float glass panes of 4.0 mm thickness |
| 39 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry |
| 40 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 41 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase |
| 42 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 43 | Providing and fixing steel structure with translucent 10 mm thick multi wall poly carbonate sheet roof in All shape complete as Per specification and E/I |
| 44 | PLUMBING WORK (POLICE STATION)Providing & Fixing 600 X 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 45 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete |
| 46 | Providing & fixing white viterous china wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fitting and brackets, cutting & making good the walls wherever required. Flat back Wash Basin size 550X400 mm with single 15mm C. P. brass pillar tap |
| 47 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. |
| 48 | Providing & fixing salem stainless steel AISI 304(18/8) kitchen sink without drain board as per IS : 13983 with C. I. brackets and stainless steel plug 40 mm including painting of fitting and brackets cutting and making good the walls wherever required. (In Pantry) 610 x 510 bowl depth 200 mm |
| 49 | Providing and fixing 8 mm dia C.P. / S.S. Jet (Health Faucet) with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge |
| 50 | Providing & fixing Polypropylene Silent Bottle trap with 50 mm clear water seal fitted with built-in Air Admittance valve of adequate capacity with factory supplied extension piece. 32 mm dia (for Wash Basin) |
| 51 | Providing & fixing C.P. Brass Single lever telephonic wall mixer of quality & make as approved by Engineer-in-charge. (a) 15mm nominal dia |
| 52 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia (for Sink) |
| 53 | Providing and fixing toilet paper holder : C.P. brass |
| 54 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 55 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms |
| 56 | Providing & fixing C.P. Brass Double coat Hooks with CP screws. |
| 57 | Providing & fixig 15 mm dia C.P. brass table / wall mounted sink Tap with swinging casted spout & flange. |
| 58 | Providing & fixing HPL urinal partition for half stall urinals. |
| 59 | Providing & Fixing fully automatic No Touch hand dryer of SS body satin finish, suitable to operate on 220 V / 50 Hz AC power, 2500 Watt, having < 20 sec drying time, 1 min. auto cut complete with brackets. |
| 60 | Providing & fixing 15 mm dia. C.P.Brass Single lever wash basin mixer with accessories in wash basins. |
| 61 | Providing & fixing 15 mm dia. inlet C.P. brass shower head with arm complete with flange. |
| 62 | RO water purifieR - 50 lphFeed flow rate - 150 lphFeed water TDS in ppm, subject to thehardness of water being less than 500ppm - Bore well / Municipality feed water having TDS1000 ppm (Max)Iron / Maganese - NilOil / Grease - NilHydrogen Sulphide - NilRejectio of TDS : 90-95%Dimension in mm (W x D x H) in mm - (470 x 490 x 610) mmRecovery - 30%ELECTRICAL RATINGInput Power Rating - 48 V DCOperating Voltage - 230 V AC, 50 HzPower consumption - 96 WPump*2 - 48 V DCSolenoids - 24 V DCPRESSURE REQUIREMNTSMinimum Inlet Pressure - 0.5 Kg/cm2Maximum Inlet Pressure - 2 KG/cm2System Pressure - 5 kg/cm2Operating Temperature - 5 to 45' CRO Membrane Flushing - Fresh WaterParticulate Filter: Membrane Life Enhancer - 10 micronsFilter.. Sediment Filter - 10 micronsPre carbon RO Membrane Filter Post Carbon Filter RO Membrane Permanently kills Bacteria and Viruses that cause water - borne diseases like polio, Hepatitis, Diarrhea, Typhoid & gives pure drinking water. RO element - 250 Gms of Membrane Antiscalent 80 GPD x 2 in concealed housing 90% or more, which effectively removes TDSR.O. WATER PURIFIER SUITABLE FOR 50 LPHSupply, Installation, Testing & Commissioning of Reverse Osmosis based Water Purifier having output capacity of 50 LPH. |
| 63 | Supplying and fixing Full Stainless Steel Water cooler having cooling capacity 150 ltrs/hr and storage capacity 150 ltrs, including SS tank, trough & Faucets, CTC free refrigerant, high quality copper tubes with rippled Aluminium fins with adustable legs. |
| 64 | Providing, fixing, jointing and testing in position of ISI marked UV stabilized uPVC pipes for soil and waste, Type-B as per IS : 13592 suitable for rubber ring joints for vertical pipes and solvent cement joints for horizontal pipes, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors), reducers, WC connectors, couplers, cowels, clamps, hangers, rubber rings, clean outs, C P Grating for any waste connection from washing machine etc. fixing at wall / ceiling / floor level supported by clamp & hangers etc. inside duct / suspended from floor under false ceiling for proper completion of the work. The rubber ring shall confirm to IS:5382.The Pipes will be supported by either rubber lined G.I. U strap clamps on 40x40x3 mm G.I. slotted angle duly painted (for a group of pipes) or G.I. rubber lined split clamp (for independent pipes). The cost will include all support arrangements. The work includes cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site.(a) 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) |
| 65 | (b) 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) |
| 66 | Providing, fixing, jointing and testing in position ISI marked (IS:4985) UPVC pipes of min 6 Kg/ Sq cm rating with fitting for waste pipe from fixtures to floor trap including reduces, enlarger, socket, couplers, bends, tees etc including fixing at wall/ ceiling level supported by clamp & hangers etc. The work includes cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. (a) 50 mm dia. |
| 67 | (b) 40 mm dia. |
| 68 | Providing & fixing uPVC Floor trap of self cleansing design with CP Jali complete in all respects. P-Trap type Floor Trap 110 x 110 mm (Long type - 50 mm seal) |
| 69 | Providing & fixing UPVC pipe fittings for drain pipe connection under toilet floor. Reducing Tee 110x110x75 mm |
| 70 | Providing and fixing of drain point with 75 mm dia. Bend with CP Jali complete in all respects. |
| 71 | Providing and fixing on wall face unplasticised - Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion - Single socketed pipes 110 mm dia |
| 72 | Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised - Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion - Bend 87.5o110 mm bend |
| 73 | Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised - Rigid PVC rain water pipes by means of 50x50x50 mm hard wood plug screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm |
| 74 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 75 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 76 | Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge.Internal work exposed on wall(a) 15mm nominal outer dia pipes |
| 77 | (b) 20mm nominal outer dia pipes |
| 78 | (c) 25mm nominal outer dia pipes |
| 79 | (d) 32mm nominal outer dia pipes |
| 80 | (e) 40mm nominal outer dia pipes |
| 81 | (f) 50mm nominal outer dia pipes |
| 82 | Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge.Concealed work including cutting chase and making good the wall etc.(a) 15mm nominal outer dia pipes |
| 83 | (b) 20mm nominal outer dia pipes |
| 84 | (c) 25mm nominal outer dia pipes |
| 85 | (d) 32mm nominal outer dia pipes |
| 86 | Providing, fixing G. I. pipes complete with G. I. fittings and clamps including cutting and making good the walls etc. (internal work) - (Exposed on wall) (a) 50mm dia nominal bore |
| 87 | (b) 65mm dia nominal bore |
| 88 | Painting G. I. pipes and fittings with synthetic enamel white paint over a ready mixed priming coat, both of approved quality for new work. (a) 50mm dia nominal bore |
| 89 | (b) 65mm dia nominal bore |
| 90 | Providing and fixing ball valve (brass) of approved quality complete. (High or low pressure with plastic floats). (a) 15 mm nominal bore |
| 91 | (b) 20 mm nominal bore |
| 92 | (c) 25 mm nominal bore |
| 93 | Providing & fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) (a) 32 mm nominal bore |
| 94 | (b) 40 mm nominal bore |
| 95 | (c) 50 mm nominal bore |
| 96 | Providing and fixing 15 mm nominal bore brass stop cock of approved quality. |
| 97 | Providing & fixing 15 mm nominal bore 45 cm long unplasticised PVC connection pipe with brass unions. |
| 98 | Providing and fixing 15 mm nominal bore C.P brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 99 | Providing & fixing 15 mm nominal bore C.P brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931. |
| 100 | Supply, Installation, Testing & Commisioning of Thermal Insulation on hot water supply pipes using Nitrile Rubber (Fire Retardant Class O Grade) Insulation Pipe Sections, Fevicol SR-998 / Equal Adhesive & 50 mm Wide x 3 mm Thick Joint Sealing Nitrile Rubber Tape. Nominal diameter of Pipes and insulation thickness in mm as indicated below: (Exposed work on terrace / ducts) 15 mm dia pipe (9 mm thick insulation) |
| 101 | Supply, Installation, Testing & Commisioning of Mechanical Protection Coating only (Insulation not to be part of this item as the same is measured separately) on the above insulated piping with Alkali resistance glass fiber fabric (Paramount Polytreat Chemicals Make Parafeb-GFC / Approved Equal) of 5 to 7 mil (minimum) thickness reinforcement and Starbond 30-36 / equal coating. (Exposed work on terrace / ducts) for 15 mm dia pipe over 9 mm thick insulation |
| 102 | Providing, fixing, testing and commissioning of motorized butterfly valve of following dia for filling of Over Head Water tank complete with high and low level control switches to control the valve. The level controllers shall be installed in overhead tanks. The level switch will close the valve when water level is high (Top Water Level) in over head tank and open the valve when over head water tank level is low (30% of storage capacity). The system should be complete in all respects with accessories, 220 V AC / 24 V DC, IP67 electrical water level control unit, copper control wiring in whether proof casing etc. (a) 32 mm dia |
| 103 | (b) 40 mm dia |
| 104 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fitting and base support for tank. (a) 3000 litres capacity |
| 105 | (b) 4000 litres capacity |
| 106 | INTERNAL FIRE FIGHTING WORK (POLICE STATION)Supply, Fixing, Testing & Commissioning of electrical motor driven fire pump, suitable for automatic operation consisting of following : ( Terrace Fire Pump)(a) Horizontally mounted, Two stage-split casing / Multi stage, 1450 - 2900 RPM Centrifugal fire pump, as per IS:1520 complete for delivery of under mentioned discharge against desired mentioned head so as to ensure a minimum pressure of 35 meter at the highest and farthest outlet at the specified flow complete with necessary strainers, 100 mm dia dial pressure gauge of calibration 0-15 kg/sq cm including bypass arrangement for periodic testing of the working of the pumpset as well as testing of automation with required length and size of MS pipe and control valves for proper completion of work. The pump shall be capable of giving 150% of rated discharge at head not less than 65% of rated head. The pump shall be provided with Mechanical seals. The impeller shall be enclosed type and accurately balanced dynamically. The pump casing shall be of cast iron, impeller shall be of bronze and shaft shall be of stainless steel.(b) Squirrel cage, TEFC induction motor as per IS : 325, suitable for 415 V +/- 10%, 3 Phase, synchronous speed as per pump, IP 55 protection and class 'F' insulation, vaccume impregnated windings with heat and moisture resisting varnish for the above pump and flexible coupling with the pump. The motor shall be rated for continuous duty and shall have HP rating necessary to drive the pump at 150% of it's rated discharge at 65% of rated head.(c) Common bed plate of fabricated mild steel channel or cast iron type, coupling, coupling guard ets as required.(d) Suitable vibration clamping arrangement as required. with foundation bolts, anti vibration pads, washers etc. Discharge : 450 liter per minuteHead : 35 meter |
| 107 | Supply, erection and testing of ISI marked ERW M.S. pipes (Class C - heavy duty) and specials etc. (as per IS:1239 for upto 150 mm dia and IS:3589 for 200 mm and above) for above ground laying for hydrants and sprinkler system including transportation of materials upto the worksite, cutting the pipes to required length, edge preperation, welding, fixing / erection of pipes including specials i.e. bends, tees, reducers, flanges, expansion joints and bellows wherever required, washers, nuts, bolts etc. in proper position including all supports. jointing by welding, aligning the pipe line, painting with two primer coat by zinc chromate primer and two coats of synthetic enamel fire red colour, providing tapping for pressure gauges and for other instruments etc. Hydrostatic testing of system at 1.5 times of operating pressure or 15 kg / sq cm whichever is higher and as specified, flushing & cleaning by water etc. complete as per drawings & direction of the Engineer-in-charge. The pipes and accessories will be provided with all type of supports (Maximum Support spacing = up to 25 mm dia @ 2 m, 32 mm to 100 mm dia @ 2.5 m, 150 mm & above dia @ 3 m) by minimum 3 mm thick G.I. clevis / sprinkler hangers / clamps / Tie rod supports with G.I. nuts, bolts, anchor / dash fastner and washer for hydrant / sprinkler piping, for 150 mm dia pipe the support will be through 50x50x6 mm painted / pre galvanized MS angle iron along with G.I. U clamp, nuts, washers, anchor fasteners etc as the case may be.upto 40 mm dia. pipe threaded fittings and threaded joints shall be provided (by white lead and spun yarn) and for 50 mm dia & above pipes welded joints shall be used. The Ductile iron fittings or Malleable Iron (IS : 1879) fittings shalll be heavy duty suitable to withstand at least a pressure of 150% of maximum working pressure with minimum of 15kg/cm2.100 mm dia |
| 108 | Supply & installation of ISI marked single headed 63 mm dia. Stainless steel Hydrant Valve (Type A) suitable for hydrostatic test pressure of 21 kg/sqcm, 80 mm dia flanged inlet with 63 mm female instantaneous outlet confirming to IS : 5290 on the fire wet riser/down comer, including making 80 NB pipe flange connection with riser, fixing the landing valves in proper positions, including supply of nuts, bolts, gaskets, caps, chains etc. testing the hydrant and completing the work in all respect as per directions of the Engineer-in-charge. |
| 109 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required. (a) 100 MM NB |
| 110 | (b) 150 MM NB |
| 111 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required (a) 100 NB |
| 112 | Providing and fixing C I body flanged S S strainer fabricated out of 1.6 mm thick Stainless Steel 304 sheet having 3 to 5 mm dia perforation. 150 mm dia. |
| 113 | Providing ISI marked RRL (IS : 636, type-A) fire hose pipe 15 meter long and 63 mm dia with ISI marked (IS : 903) suitable for hydrostatic test pressure 21 kg/sqcm, Stainless steel male and female coupling bound and rivetted to hose pipes with copper rivets and copper wire complete as required. |
| 114 | Supply, fixing, testing & commissioning of 20 mm bore and 40 meter long hose (high pressure rubber braided hose pipe as per IS:444 or Thermo plastic (Textile reinforced) fire hose pipe as per IS 12585) and hose reel, (The complete assembly shall be capable of withstanding the hydrostatic test pressure 21 kg/sqcm), for first aid fire fighting conforming to IS : 884, with 180o full swing drum, fixing brackets, 5 mm dia shut off Stainless steel nozzle, connecting directly from the riser through 40 mm dia. MS (Class C) pipe with sockets, elbows, nipples, 40x20 mm reducer, 20 dia pipe, 20 mm dia. hand lever operated isolating ball valve, etc. including providing operating instructions on a metal plate and fixing it near hose reel. The system shall be complete in all respects as per drawings and directions of Engineer-in-charge. |
| 115 | Providing Stainless steel ISI marked 63 mm. dia. male Instantaneous pattern short branch pipes with 20 mm dia. Nozzle as per IS : 903, suitable for hydrostatic test pressure 21 kg/sqcm and suitable for interconnections to hose pipe coupling as required. |
| 116 | Supply & erection of ISI marked portable fire extinguishers, confirming to IS:15683, wall mounted type, wall brackets complete in all respect as per standard item with all accessories, delivery hose & nozzle whereever required, including fixing on walls as per the directions of Engineer-in-charge. (a) Water CO2 type. 9 Lt. capacity |
| 117 | (b) ABC dry powder Type 6 kg. capacity |
| 118 | Providing & fixing neoprene rubber double flanged rubber expansion joint (anti vibration bellow) of standard length as per manufacturers specifications. suitable for hydrostatic test pressure of 21 kg/sqcm including all necessary fittings i.e. rubber gasket, nuts, bolts, washers etc complete as required. 80 mm dia. |
| 119 | Providing & fixing standard carbon steel fireman axe with rubber insulated handle tested to 20000 Volts. |
| 120 | Providing and fixing weather proof standard fire hose cabinet (750 mm x 600 mm x 250 mm) outdoor type made of not less than 16 SWG MS sheet having glassed hinged door (5 mm thick glass) including necessary locking arrangement with handle for housing two nos.15 meter long fire hose pipes, branch pipe as required as per drawings, including brackets for mounting accessories, painting (one coat primer and two coat of fire red colour). The cabinet shall be mounted on self standing mounted type MS Angle iron frame as required. The words \\"FIRE HOSE\\" to be painted on the box. |
| 121 | Providing and fixing standard fire hose cabinet door with frame (900 mm x 2000 mm ) or (suitable to fit in the duct made of not less than 16 SWG MS sheet having glass hinged door (5 mm thick glass) including necessary locking arrangement with handle as required as per drawings, including brackets for mounting accessories, painting (one coat primer and two coats of fire red colour). The door shall be fixed in the masonry wall or as required. The words \\"FIRE HOSE\\" to be painted on the box. |
| 122 | Providing & fixing 100 mm dia dial pressure gauge including making connections with MS pipe complete in all respects. |
| 123 | INTERNAL ELECTRIC WORK (POLICE STATION)Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 124 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 125 | Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 126 | Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required. |
| 127 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. |
| 128 | (b) 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire. |
| 129 | (c) 2 x 10 sq.mm. + 1 x 6 sq.mm. earth wire. |
| 130 | (d) 4 x 10 sq.mm. + 2 x 6 sq.mm. earth wire. |
| 131 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 132 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 133 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 134 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 135 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 136 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Bell push |
| 137 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as Required. Single pole |
| 138 | Supplying and Fixing Following way, Horizontal Type Three Pole and Neutral, Sheet Steel, MCB Distribution Board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). (a) 6 Way (4 + 18), Double Door |
| 139 | (b) 8 Way (4 + 24), Double Door |
| 140 | Supplying and fixing following way, Single Pole and Neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). (a) 8 Way Double door. |
| 141 | (b) 12 Way Double door. |
| 142 | Supplying and fixing following Rating, Double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as Required. 40 Amps |
| 143 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as Required. 63 Amps |
| 144 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as Required. 40 Amps |
| 145 | Supplying and Fixing Following Size/ Modules, GI Box Alongwith Modular Base & Cover Plate for Modular Switches in Recess etc. as Required. 1 or 2 Module (75 mm x 75 mm) |
| 146 | Supplying and Fixing Following Modular Switch/ Socket on The Existing Modular plate & Switch Box including connections But Excluding Modular Plate etc. as required. (a) Telephone Socket outlet. |
| 147 | (b) TV Antenna socket outlet. |
| 148 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm. |
| 149 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, Unarmored Telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair |
| 150 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 151 | Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc. complete as required. 1 run of cable |
| 152 | Supplying & Fixing Modular Type Computer jack RJ 45 ISI mark 1 Module on existing Mounting plate and box Complete with all accessories as required. |
| 153 | Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim . (a) 12 -15 watt |
| 154 | (b) 18 watt |
| 155 | Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output.LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) (a) 40 watt |
| 156 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) (a) 18- 22 watt |
| 157 | (b) 40 watt |
| 158 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 159 | Installation, Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 160 | Installation of Exhaust fan in the existing opening, including making good the damage, Connection, Testing, Commissioning etc. as Required. Upto 450 mm sweep |
| 161 | Extra for Fixing the Louvers/ Shutters Complete with Frame for a Exhaust Fan of all sizes. |
| 162 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 163 | Supply, of Linear & Compact 10W Mirror Light with Decorative Grey Caps, Polycarbonate Body & Ribbed Opal Diffuser. |
| 164 | Supply of AC 230/250 volts, 50 HZ - 300mm Exhaust Fans Including Providing Nuts, Bolts, Mounting Frame and Other Accessories etc. Complete as Required. 300 mm sweep 900 rpm |
| 165 | GARRAGE POLICE STATIONSurface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil |
| 166 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-incharge..All kinds of soil. |
| 167 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. |
| 168 | Carriage of surplus excavated earth including loading, unloading and staking up to 50 mtr. |
| 169 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 170 | Providind and lying1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 171 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concreteAll works upto plinth levelConcrete of M25 grade with minimum cement content of 330 kg /cum |
| 172 | All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 173 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 174 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 175 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 176 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 177 | Weather shed chajja, corbals etc including edges |
| 178 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 179 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 180 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) : With F.P.S.(non modular) bricks |
| 181 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement :3 coarse sand) |
| 182 | Providing and fixing 18 mm thick Granite (gang saw cut) mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble Area of slab over 0.50 sqm |
| 183 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Marble work |
| 184 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 185 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy,bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 186 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-chargeSecond class teak wood 30 mm thick shutters |
| 187 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 188 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg. |
| 189 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Double charge vitrified tile polished finish of Size of Tile 600x600 mm |
| 190 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 191 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) |
| 192 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) |
| 193 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 194 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 195 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour Two coats |
| 196 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : for door Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 197 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 198 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural dra wings and the directions of engineer-in-charge . With float glass panes of 4.0 mm thickness |
| 199 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry |
| 200 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 201 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase |
| 202 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 203 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 204 | Providing and fixing ball bearing for rolling shutters. |
| 205 | Extra for providing mechanical device chain and crank operation for operating rolling shuttersExceeding 10.00 sqm and upto 16.80 sqm in the area |
| 206 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 207 | PLUMBING WORK (GARRAGE POLICE STATION)Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete |
| 208 | Providing & fixing white viterous china wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fitting and brackets, cutting & making good the walls wherever required.Flat back Wash Basin size 550X400 mm with single 15mm C. P. brass pillar tap |
| 209 | Providing & fixing salem stainless steel AISI 304(18/8) kitchen sink without drain board as per IS : 13983 with C. I. brackets and stainless steel plug 40 mm including painting of fitting and brackets cutting and making good the walls wherever required. (In Pantry) 610 x 510 bowl depth 200 mm |
| 210 | Providing and fixing 8 mm dia C.P. / S.S. Jet (Health Faucet) with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge |
| 211 | Providing & fixing Polypropylene Silent Bottle trap with 50 mm clear water seal fitted with built-in Air Admittance valve of adequate capacity with factory supplied extension piece. 32 mm dia (for Wash Basin) |
| 212 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia (for Sink) |
| 213 | Providing, fixing, jointing and testing in position of ISI marked UV stabilized uPVC pipes for soil and waste, Type-B as per IS : 13592 suitable for rubber ring joints for vertical pipes and solvent cement joints for horizontal pipes, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors), reducers, WC connectors, couplers, cowels, clamps, hangers, rubber rings, clean outs, C P Grating for any waste connection from washing machine etc. fixing at wall / ceiling / floor level supported by clamp & hangers etc. inside duct / suspended from floor under false ceiling for proper completion of the work. The rubber ring shall confirm to IS:5382.The Pipes will be supported by either rubber lined G.I. U strap clamps on 40x40x3 mm G.I. slotted angle duly painted (for a group of pipes) or G.I. rubber lined split clamp (for independent pipes). The cost will include all support arrangements. The work includes cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site.(a) 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) |
| 214 | (b) 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) |
| 215 | Providing, fixing, jointing and testing in position ISI marked (IS:4985) UPVC pipes of min 6 Kg/ Sq cm rating with fitting for waste pipe from fixtures to floor trap including reduces, enlarger, socket, couplers, bends, tees etc including fixing at wall/ ceiling level supported by clamp & hangers etc. The work includes cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. (a) 50 mm dia. |
| 216 | (b) 40 mm dia. |
| 217 | Providing & fixing uPVC Floor trap of self cleansing design with CP Jali complete in all respects. P-Trap type Floor Trap 110 x 110 mm (Long type - 50 mm seal) |
| 218 | Providing & fixing UPVC pipe fittings for drain pipe connection under toilet floor. Reducing Tee 110x110x75 mm |
| 219 | Providing and fixing of drain point with 75 mm dia. Bend with CP Jali complete in all respects. |
| 220 | Providing and fixing on wall face unplasticised - Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion - Single socketed pipes 110 mm dia |
| 221 | Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised - Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion - Bend 87.5o110 mm bend |
| 222 | Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised - Rigid PVC rain water pipes by means of 50x50x50 mm hard wood plug screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm |
| 223 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 224 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 225 | Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge.Internal work exposed on wall(a) 15mm nominal outer dia pipes |
| 226 | (b) 20mm nominal outer dia pipes |
| 227 | (c) 25mm nominal outer dia pipes |
| 228 | (d) 32mm nominal outer dia pipes |
| 229 | (e) 40mm nominal outer dia pipes |
| 230 | Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge.Concealed work including cutting chase and making good the wall etc.(a) 15mm nominal outer dia pipes |
| 231 | (b) 20mm nominal outer dia pipes |
| 232 | Providing and fixing ball valve (brass) of approved quality complete. (High or low pressure with plastic floats). (a) 15 mm nominal bore |
| 233 | (b) 20 mm nominal bore |
| 234 | (c) 25 mm nominal bore |
| 235 | Providing & fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) (a) 32 mm nominal bore |
| 236 | (b) 40 mm nominal bore |
| 237 | (c) 50 mm nominal bore |
| 238 | Providing & fixing 15 mm nominal bore 45 cm long unplasticised PVC connection pipe with brass unions. |
| 239 | Providing & fixing 15 mm nominal bore C.P brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931. |
| 240 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fitting and base support for tank. (a) 500 litres capacity |
| 241 | (b) 1000 litres capacity |
| 242 | FIRE FIGHTING WORK (GARRAGE POLICE STATION)Supply, erection and testing of ISI marked ERW M.S. pipes (Class C - heavy duty) and specials etc. (as per IS:1239 for upto 150 mm dia and IS:3589 for 200 mm and above) for above ground laying for hydrants and sprinkler system including transportation of materials upto the worksite, cutting the pipes to required length, edge preperation, welding, fixing / erection of pipes including specials i.e. bends, tees, reducers, flanges, expansion joints and bellows wherever required, washers, nuts, bolts etc. in proper position including all supports. jointing by welding, aligning the pipe line, painting with two primer coat by zinc chromate primer and two coats of synthetic enamel fire red colour, providing tapping for pressure gauges and for other instruments etc. Hydrostatic testing of system at 1.5 times of operating pressure or 15 kg / sq cm whichever is higher and as specified, flushing & cleaning by water etc. complete as per drawings & direction of the Engineer-in-charge. The pipes and accessories will be provided with all type of supports (Maximum Support spacing = up to 25 mm dia @ 2 m, 32 mm to 100 mm dia @ 2.5 m, 150 mm & above dia @ 3 m) by minimum 3 mm thick G.I. clevis / sprinkler hangers / clamps / Tie rod supports with G.I. nuts, bolts, anchor / dash fastner and washer for hydrant / sprinkler piping, for 150 mm dia pipe the support will be through 50x50x6 mm painted / pre galvanized MS angle iron along with G.I. U clamp, nuts, washers, anchor fasteners etc as the case may be.upto 40 mm dia. pipe threaded fittings and threaded joints shall be provided (by white lead and spun yarn) and for 50 mm dia & above pipes welded joints shall be used. The Ductile iron fittings or Malleable Iron (IS : 1879) fittings shalll be heavy duty suitable to withstand at least a pressure of 150% of maximum working pressure with minimum of 15kg/cm2.100 mm dia |
| 243 | Supply & installation of ISI marked single headed 63 mm dia. Stainless steel Hydrant Valve (Type A) suitable for hydrostatic test pressure of 21 kg/sqcm, 80 mm dia flanged inlet with 63 mm female instantaneous outlet confirming to IS : 5290 on the fire wet riser/down comer, including making 80 NB pipe flange connection with riser, fixing the landing valves in proper positions, including supply of nuts, bolts, gaskets, caps, chains etc. testing the hydrant and completing the work in all respect as per directions of the Engineer-in-charge. |
| 244 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required. 100 MM NB |
| 245 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 246 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required 100 NB |
| 247 | Providing and fixing C I body flanged S S strainer fabricated out of 1.6 mm thick Stainless Steel 304 sheet having 3 to 5 mm dia perforation. 100 mm dia. |
| 248 | Providing ISI marked RRL (IS : 636, type-A) fire hose pipe 15 meter long and 63 mm dia with ISI marked (IS : 903) suitable for hydrostatic test pressure 21 kg/sqcm, Stainless steel male and female coupling bound and rivetted to hose pipes with copper rivets and copper wire complete as required. |
| 249 | Supply, fixing, testing & commissioning of 20 mm bore and 40 meter long hose (high pressure rubber braided hose pipe as per IS:444 or Thermo plastic (Textile reinforced) fire hose pipe as per IS 12585) and hose reel, (The complete assembly shall be capable of withstanding the hydrostatic test pressure 21 kg/sqcm), for first aid fire fighting conforming to IS : 884, with 180o full swing drum, fixing brackets, 5 mm dia shut off Stainless steel nozzle, connecting directly from the riser through 40 mm dia. MS (Class C) pipe with sockets, elbows, nipples, 40x20 mm reducer, 20 dia pipe, 20 mm dia. hand lever operated isolating ball valve, etc. including providing operating instructions on a metal plate and fixing it near hose reel. The system shall be complete in all respects as per drawings and directions of Engineer-in-charge. |
| 250 | Providing Stainless steel ISI marked 63 mm. dia. male Instantaneous pattern short branch pipes with 20 mm dia. Nozzle as per IS : 903, suitable for hydrostatic test pressure 21 kg/sqcm and suitable for interconnections to hose pipe coupling as required. |
| 251 | Supply, installation and testing of cylindrical type flanged air cushion tank, 250 mm dia, 1200 mm long and of thickness 8 mm M.S., suitable supporting legs with MS plate of size 75x75x5 mm at the bottom and grouted in CC foundation. The air cushion tank shall be provided with air release valve, stop cock, safety valve, pressure gauge, 25 mm dia drain valve, tested to min 25 Kg/cm2 complete including painting with synthetic enamel paint of approved shade with all accessories as per direction of the Engineer-in-charge. (For Risers) |
| 252 | Supply & erection of ISI marked portable fire extinguishers, confirming to IS:15683, wall mounted type, wall brackets complete in all respect as per standard item with all accessories, delivery hose & nozzle whereever required, including fixing on walls as per the directions of Engineer-in-charge. (a) Water CO2 type. 9 Lt. capacity |
| 253 | (b) ABC dry powder Type 6 kg. capacity |
| 254 | Providing & fixing standard carbon steel fireman axe with rubber insulated handle tested to 20000 Volts. |
| 255 | Providing and fixing weather proof standard fire hose cabinet (750 mm x 600 mm x 250 mm) outdoor type made of not less than 16 SWG MS sheet having glassed hinged door (5 mm thick glass) including necessary locking arrangement with handle for housing two nos.15 meter long fire hose pipes, branch pipe as required as per drawings, including brackets for mounting accessories, painting (one coat primer and two coat of fire red colour). The cabinet shall be mounted on self standing mounted type MS Angle iron frame as required. The words \\"FIRE HOSE\\" to be painted on the box. |
| 256 | Providing and fixing standard fire hose cabinet door with frame (900 mm x 2000 mm ) or (suitable to fit in the duct made of not less than 16 SWG MS sheet having glass hinged door (5 mm thick glass) including necessary locking arrangement with handle as required as per drawings, including brackets for mounting accessories, painting (one coat primer and two coats of fire red colour). The door shall be fixed in the masonry wall or as required. The words \\"FIRE HOSE\\" to be painted on the box. |
| 257 | Providing & fixing 100 mm dia dial pressure gauge including making connections with MS pipe complete in all respects. |
| 258 | INTERNAL ELECTRICAL WORK - GARAGE AND CAFETARIAWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 259 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 260 | Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 261 | Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required. |
| 262 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. |
| 263 | (b) 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire. |
| 264 | (c) 2 x 10 sq.mm. + 1 x 6 sq.mm. earth wire. |
| 265 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 266 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 267 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as Required. Single pole |
| 268 | Supplying and fixing following way, Single Pole and Neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). (a) 8 Way Double door. |
| 269 | (b) 12 Way Double door. |
| 270 | Supplying and fixing following Rating, Double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as Required. 40 Amps |
| 271 | Supplying and Fixing Following Size/ Modules, GI Box Alongwith Modular Base & Cover Plate for Modular Switches in Recess etc. as Required. 1 or 2 Module (75 mm x 75 mm) |
| 272 | Supplying and Fixing Following Modular Switch/ Socket on The Existing Modular plate & Switch Box including connections But Excluding Modular Plate etc. as required. TV Antenna socket outlet. |
| 273 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm. |
| 274 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 275 | Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim . (a) 12 -15 watt |
| 276 | (b) 18 watt |
| 277 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 18- 22 watt |
| 278 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req CM/Min (Minimum) |
| 279 | Installation of Exhaust fan in the existing opening, including making good the damage, Connection, Testing, Commissioning etc. as Required. Upto 450 mm sweep |
| 280 | Extra for Fixing the Louvers/ Shutters Complete with Frame for a Exhaust Fan of all sizes. |
| 281 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 282 | Supply of AC 230/250 volts, 50 HZ - 300mm Exhaust Fans Including Providing Nuts, Bolts, Mounting Frame and Other Accessories etc. Complete as Required. 300 mm sweep 900 rpm |
| 283 | BOUNDARY WALLEarth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 Sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 284 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. |
| 285 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concreteAll works upto plinth levelConcrete of M25 grade with minimum cement content of 330 kg /cum |
| 286 | Concrete of M25 grade with minimum cement content of 330 kg /cumAll works above plinth level upto floor V level |
| 287 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 288 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 289 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 290 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. Grill |
| 291 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 292 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 293 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 294 | 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 Coarse sand. |
| 295 | Painting or varnishing work in small areas or new wood work with one coat upto one square metre of ready mixed priming paint and one coat of approed superior quality ready mixed paint or varnish including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. Paint to be used should fonfirm the ISI no. 103-1950 (M.S. works) |
| 296 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat ofexterior primer applied @ 2.20kg/10 sqm |
| 297 | PARKINGEarth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. |
| 298 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 299 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 300 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 301 | RAIN WATER HARVESTINGEarth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. |
| 302 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil |
| 303 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 304 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 305 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 306 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 307 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 308 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground levelAll types of soil 400 mm dia |
| 309 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well casing(CM) pipe of required dia, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia |
| 310 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, onforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia |
| 311 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 312 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. |
| 313 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. |
| 314 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin- charge. |
| 315 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in pproved laboratory, i/c disinfection of ubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per uirement and direction of Engineer-in-charge. |
| 316 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm dia |
| 317 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 150 mm dia |
| 318 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : |
| 319 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:All kinds of soilPipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. |
| 320 | Providing, laying and jointing P.V.C. pipes including testing of joints etc. complete : 150 mm dia pipe 6 KG |
| 321 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round P.V.C./HDPE pipes including bed concrete as per standard design: 150 mm diameter |
| 322 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 323 | Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 324 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:All kinds of soil |
| 325 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 326 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) 1:4 |
| 327 | 12 mm cement plaster on brick work with cement mortar of mix (up to 10 mtr height from ground level) 1:6 (1 cement: 6 Coarse Sand) |
| 328 | Providing and laying Cement concrete 1:2:4 (1cement :2 coarse sand :4 graded stone ballast 20 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation. |
| 329 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. |
| 330 | SEPTIC TANK AND SOAK PITEarth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. |
| 331 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil |
| 332 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 333 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 334 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : Cement mortar 1:4 (1 cement :4 coarse sand) |
| 335 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 336 | Providing and laying Cement concrete 1:2:4 (1cement :2 coarse sand :4 graded stone ballast 20 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation. |
| 337 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 338 | 12 mm cement plaster on brick work with cement mortar of mix (up to 10 mtr height from ground level) 1:6 (1 cement: 6 Coarse Sand) |
| 339 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design :Foot Step (5 kg/sqm.) |
| 340 | Providing and fixing soil, waste and vent pipes :Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 C.I. Pipe (75 mm dia) |
| 341 | Providing and fixing C.I.cowel. Sand cast iron S&S as per IS - 3989 |
| 342 | 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg |
| 343 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks |
| 344 | M.S. GATEEarth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil |
| 345 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources |
| 346 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concreteAll works upto plinth levelConcrete of M25 grade with minimum cement content of 330 kg /cum |
| 347 | Concrete of M25 grade with minimum cement content of 330 kg /cumAll works above plinth level upto floor V level |
| 348 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 349 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 350 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 351 | Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works |
| 352 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 353 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shadeTwo or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 354 | TUBEWELLBoring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground levelAll types of soil 400 mm dia |
| 355 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level |
| 356 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mm |
| 357 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia |
| 358 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer for all leads & lifts, all complete as per direction of Engineer -incharge. |
| 359 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 360 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. |
| 361 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: |
| 362 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. |
| 363 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). |
| 364 | Electric logging of bore hole |
| 365 | Cable 16/25 mm 4CORE |
| 366 | Controle Paneel ( L&T Make) |
| 367 | Testing of Tube Well Boring by DG Set as requaired |
| 368 | Supply and Installation of 5 HP Submersible pump set with 250 LPM discharge complete pipes with fittings |
| 369 | ROADPreparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. |
| 370 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) For kerb stone |
| 371 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 26.5 mm to 0.075 mm ) having CBR Value-20 Road |
| 372 | Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. |
| 373 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 374 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 600mm c/c |
| 375 | EXTERNAL PLUMBING WORKProviding, fixing G. I. pipes complete with all required G. I. fittings including trenching and refilling etc. (external work) Municipal and borewell line to fill UGT, Domestic and Flushing line (a) 65 mm. dia nominal bore |
| 376 | (b) 80 mm. dia nominal bore |
| 377 | Providing and filling sand of grading zone V or coarser grade alround the G.I. pipes in external work. (a) 65 mm. dia nominal bore |
| 378 | (b) 80 mm. dia nominal bore |
| 379 | Painting G. I. Pipes & fittings with two coats of anti-corrosive bitumastic paint of approved quality (a) 65 mm. dia nominal bore |
| 380 | (b) 80 mm. dia nominal bore |
| 381 | Providing & fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) (a) 32 mm nominal bore |
| 382 | (b) 40 mm nominal bore |
| 383 | (c) 65 mm nominal bore |
| 384 | (d) 80 mm nominal bore |
| 385 | Making connection of G.I.distribution branch with G.I.mains of following size by providing and fixing Tee, including cutting and threading the pipe etc. complete. (a) 25 to 40 mm. Nominal bore |
| 386 | (b) 50 to 80 mm. Nominal bore |
| 387 | Fixing water meter and stop cock in G.I.pipe line including cutting and threading the pipe and making longscrews etc.complete ( cost of water meter and stop cock to be paid seperately ) |
| 388 | Excavating trenches upto 1.5 meter depth in all kind of soil of required width for pipes. including excavation for sockets and dressing of sides ramming of bottoms including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. (i) Pipes, cables etc, not exceeding 80 mm dia. |
| 389 | Constructing brick masonry chamber 600 x 600 x 750 mm inside with F.P.S. brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for Sluice Valve, with C. I. surface box 100 mm top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 grade stone aggregate 20 mm nominal size); necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1 : 3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design |
| 390 | Constructing brick masonry chamber 600 x 450 x 500 mm, inside with F.P.S. brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for Water Meter complete with C. I. double flap surface box 400x200x200 mm (inside) with locking arrangment and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 grade stone aggregate 20mm nominal size) necessary excavation,foundation concrete 1:5:10 (1 cement :5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design |
| 391 | Providing, fixing, joints and testing in position the following uPVC Pipe conferming to IS:4985 of 6kg sqcm for garden irrigation system cut to required length pipe to be laid below level in trenches up to required depth, including excavation in all kind of soil. (a) 32 mm OD |
| 392 | (b) 40 mm OD |
| 393 | (c) 50 mm OD |
| 394 | Providing & fixing in position 25 mm dia lawn hydrants consisting of 25 mm dia Ball valve, GI nipple and threaded hose receiver complete as required. |
| 395 | Providing & fixing 16mm dia and 4mm pvc drip irrigation hose for irrigation of black color with emitter, straight connector and all accessories complete in all respects. |
| 396 | Excavating trenches in all kind of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m.up to 1.50 m depthPipes 80 mm to 300 mm diameter |
| 397 | Providing and laying in position cement concrete excluding the cost of centering and shuttering. (in all type of work upto plinth level) by 1:4:8 (1 cement : 4 coarse sand : 8 graded stone agg. 40 mm nominal size) |
| 398 | Constructing brick masonary road gully chamber 50 x 45 x 60cm with F.P.S. brick in cement mortar 1 : 4 (1 cement : 4 coarse sand) including 500 x 450 mm pre cast RCC horizontal grating with frame complete as per standard design. |
| 399 | Constructing brick masonary road gully chamber 110x50x77.5 cm with F.P.S. brick in cement mortar 1 : 4 (1 cement : 4 coarse sand) including 500 x 450 mm pre cast RCC horizontal grating with frame and vertical grating complete as per standard design. |
| 400 | Supply, laying, jointing, testing and commissioning of H.D.P.E. (DWC) Double wall Corrugated pipe (IS:16098) having corrugation on outer wall and plain smooth surface at inner side for interconnection of catch pits / drains in drainage system crossing expansion joints, complete in all respects. For drainage (a) 150 mm. ID |
| 401 | (b) 200 mm. ID |
| 402 | (c) 250 mm. ID |
| 403 | (d) 300 mm. ID |
| 404 | Providing extra depth of Catch pits including excavation, all civil work complete. (a) For 500 x 450 mm inner size |
| 405 | (b) For 1100 x 500 mm inner size |
| 406 | Excavating trenches in all kind of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m.up to 1.50 m depthPipes 80 mm to 300 mm diameter |
| 407 | Providing and laying in position cement concrete excluding the cost of centering and shuttering. (in all type of work upto plinth level) by 1:4:8 (1 cement : 4 coarse sand : 8 graded stone agg. 40 mm nominal size) |
| 408 | Constructing brick masonry manhole with F.P.S. bricks in cement mortar 1 : 4 (1 cement : 4 coarse sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 grade stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1cement 3 coarse sand ) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finishd with a floating coat of neat cement complete as per standard designInside size 90 x 80 cm & 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimension total wt. of cover & frame to be not less than 38 kg (wt. of cover 23 kg and wt. of frame 15 kg) |
| 409 | Extra for depth for manhole with F.P.S. bricks size 90 X 80 cm |
| 410 | Making connection of sewer/drain line with existing manhole including breaking into & making good the wall, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1 : 3 (1cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete For pipes 250 to 300 mm diameter |
| 411 | Providing M.S. foot rests including fixing in manholes with 20*20*10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) as per standard design : with 20 x 20 mm square bar |
| 412 | Providing and fixing square mouth S. W. Gully trap grade `A' complete with C.I. grating brick masonry chamber with F.P.S bricks and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 180 x 150 mm. size P type |
| 413 | Supply, laying, jointing, testing and commissioning of H.D.P.E. (DWC) Double wall Corrugated pipe (IS:16098) having corrugation on outer wall and plain smooth surface at inner side for interconnection of catch pits / drains in drainage system crossing expansion joints, complete in all respects. For Sewerage (a) 150 mm. ID |
| 414 | (b) 200 mm. ID |
| 415 | (c) 250 mm. ID |
| 416 | EXTERNAL ELECTRIFICATION WORKTHANA BUIDLING FLOOR PANELS TYPICALDesign, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchbaord suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing Provision which connected to the nearest earth grid.INCOMER : 100 AMP FP MCCBBUS BAR : 125 AMP, 500 Volts, 3 phase 50 HZ 4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.8 sq mm / amp.The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature.OUT GOINGS : 6 No 63 AMP 4P MCB complete panel as above and complete |
| 417 | RESIDENTIAL BUILDING METER BOARD PANELDesign, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchbaord suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing Provision which connected to the nearest earth grid.INCOMER : 125 AMP FP MCCBBUS BAR : 160 AMP, 500 Volts, 3 phase 50 HZ 4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.8 sq mm / amp.The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature.OUT GOINGS : 4 No 63 AMP 4P MCB & Space For 1 No 3 Phase KWH Meter with Indication Lamps (Flat DB's)1 No 40 AMP DP MCB & Space For 1 No 1 Phase KWH Meter with Indication Lamps (Common area DB)1 No 63 AMP 4P MCB (SPARE)1 No 40 AMP 4P MCB (SPARE)complete panel as above and complete |
| 418 | GARAGE & CANTEEN PANELDesign, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchbaord suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing Provision which connected to the nearest earth grid.INCOMER 1 : 1 Nos 100 AMP FP MCCBBUS BAR : 125 AMP, 500 Volts, 3 phase 50 HZ 4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.8 sq mm / amp.The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature.OUT GOINGS : 3 No 40 AMP DP MCB WITH INDICATING LAMPScomplete panel as above and complete |
| 419 | EXTERNAL LIGHT FEEDER PILLAR Design, Manufacture, Supply, Installation, Testing and Commissioning of Panel Fabricated out of 16 SWG CRCA sheet steel, IP 54, wall / floor mounting type with rain canopy The sheet steel shall undergo minimum 7 tank treatment followed by finishing powder coating of min 60 micron thickness. the board includes 415 /240 V electrolitic Aluminium Bus Bar, removable gland plates, cable glands, including connection with outgoing feeders complete in all respect, Panel Should Have Double Earthing Provision Which Connected to the Nearest Earth Grid. INCOMER:1 no. 100A, 50KA 4P MCCB with microprocessor based releases, ON indication, 1 no. multifunction meter (showing all power parameters), with Selector Switch, Matching Cast Resin CT's. + 3 Nos 63A DP MCB For each Phase.with 3 Nos Astronomical Weekly programmable time switch (SST- 1min) ON Phase for automaitc switching of landscape light fixtures at sun set and sun rise or twilight (auto on/ auto off and auto mode) with manual override faiclity with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site.BUS BARTPN Aluminium bus bar with heat Shrink Sleeve rated for 125A. OUTGOING12 nos 16A DP MCB 3 nos 40A DP MCB1 nos 63A 4P MCBOther items such as1 Set of control wiring1 Set of designation platesAll Items complete as above |
| 420 | SUPPLY OF L.T. CABLE:Supplying of Following Sizes of 1.1 KV Grade Multicore Aluminium Conductor XLPE Power Cable Insulated armoured cable conforming to IS:7098 (Part - I) or as per Relevant IS Code complete with all Amendments etc and should be NABL certified as required.(a) 3.5 C X 300 Sq.mm Al. XLPE arm. |
| 421 | (b) 3.5 C X 185 Sq.mm Al. XLPE arm. |
| 422 | (c) 3.5 C X 95 Sq.mm Al. XLPE arm. |
| 423 | (d) 3.5 C X 50 Sq.mm Al. XLPE arm. |
| 424 | (e) 3.5 C X 35 Sq.mm Al. XLPE arm. |
| 425 | (f) 3.5 C X 25 Sq.mm Al. XLPE arm. |
| 426 | LT CABLE LAYINGLaying of One Number PVC Insulated And PVC Sheathed / XLPE Power Cable of 1.1 kV Grade of Following Size Direct in Ground Including Excavation, Sand Cushioning, Protective Covering and Refilling the Trench etc. as required.(a) Upto 35 sq. mm |
| 427 | (b) Above 35 sq. mm and upto 95 sq. mm |
| 428 | (c) Above 95 sq. mm and upto 185 sq. mm |
| 429 | (d) Above 185 sq. mm and upto 400 sq. mm |
| 430 | LT CABLE JOINTING & END TERMINATIONSupplying and Making End Termination With Brass Compression Gland and Aluminium lugs for Following Size of PVC Insulated and PVC Sheathed/ XLPE Aluminium Conductor Cable of 1.1 kV Grade as Required.(a) 3½ X 25 sq. mm (28mm) |
| 431 | (b) 3½ X 35 sq. mm (32mm) |
| 432 | (c) 3½ X 50 sq. mm (35mm) |
| 433 | (d) 3½ X 95 sq. mm (45mm) |
| 434 | (e) 3½ X 185 sq. mm (57mm) |
| 435 | (f) 3½ X 300 sq. mm (70mm) |
| 436 | Supply of H.T. CableSupply & Testing of following 11 KV (E) grade multicore Aluminium conductor XLPE insulated cable, insulation screening with extruded semi conducting compound in combination with copper tape armoured cores laid up, inner sheath of PVC tape, galvanised steel flat strip armoured and overall PVC sheathed cable conforming to IS: 7098 (Part - II) and complete with all latest amendments etc. complete as required.3 C x 120 Sq. mm 11 KV (E) |
| 437 | H V CABLE LAYINGLaying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 120 sq. mm |
| 438 | Supply and making Indoor cable end jointing with cast resin compund, including lugs and other jointing materials for following size of 3 core, XLPE aluminium conductor cable of 11KV grade as required. 3 C x 120 Sq.mm |
| 439 | Supply and making Outdoor cable end jointing with cast resin compund, including lugs and other jointing materials for following size of 3 core, XLPE aluminium conductor cable of 11KV grade as required. 3 C x 120 Sq.mm |
| 440 | Supply and Making Straight Through Cable Jointing With Cast Resin Compund, Including Ferrule & Other Jointing Materials for Following Size of 3 core, XLPE Aluminium conductor cable of 11KV grade as required. 3 C x 120 Sq.mm |
| 441 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required. |
| 442 | Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single Red colour on front side as required. |
| 443 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.. (BODY EARTHING) |
| 444 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.. (NEUTRAL EARTHING) |
| 445 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 446 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 447 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 448 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 449 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 450 | Providing and laying non pressure NP2 class (light duty) RCC pipes with collars jointed with stiff mixtures of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. 250 mm dia |
| 451 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design. With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 452 | Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 453 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 200 mm dia (OD-200 mm & ID-175 mm nominal) |
| 454 | POLE ERECTIONErection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 4.5 metre and upto 6.5 metre |
| 455 | Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape , Hole Seeling to be done complete as required. 32 mm dia |
| 456 | SUPPLY OF EXTERNAL LIGHTING SYSTEMSupply , Installation, Testing & Commissioning of Integrated Post Top Lantern With 40W LED Lamp including Pole & connection with 3 x 2.5 sq.mm single core PVC insulated copper conductor cable from junction box to fixture as required. |
| 457 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 72 watt |
| 458 | Supply, Installation, Testing and Commissioning of 200x160x98 (KVPC) Polycarbonate thermoplastics enclosure - junction box with I.P - 65 Protection with Terminals & cable hinged cover of approved design complete having gasket of internally embedded & made of polyeutherene & should be weather proof, rust proof, dust proof, water proof - box shall be tested as per IEC - 60670-2/60670-22. the box shall have self threaded holes & provision for mounting din rail. with 2 Nos cable gland including supplying & fixing crimping 2 nos lugs & 1 nos 32A connector 6 way for looping the incoming & outgoing cables and also connection of the street light one 6A SP MCB Including Connection of 2x6 sqmm Cable etc as Required. |
| 459 | Supplying of ADP Octagonal Pole Single Arm 6 m ADP, Material of Octagonal pole : Grade ISH430LA as perIS:5986:2017 latest, Base plate material : Grade: E250, Quality:BR(as per IS:2062:2011 latest) |
| 460 | Supplying of Following sizes 1100 volt grade XLPE insulated PVC sheathed aluminium conductor armoured cables as per specification in existing laid in ground including cost of digging upto required depth, 150 mm sand all around the cable, brick protection and back filling, clamped to wall with suitable clamps including saddles fixing bolts, Connection Testing and commissioning as Required. 2x6 sqmm |
| 461 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excludin g sand cushioning and protective covering. Upto 35 sq. mm |
| 462 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 core 2.5 sq.mm |
| 463 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and<135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 200 Watt |
| 464 | GST Extra as applicable Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail