| 1 | REPLACEMENT OF WIRES, COVER FRAMES, MODULAR SWITCHES, CONCEALED METAL BOXES AND OTHER ACCESSORIES IN THE EXISTING RECESSED CONDUIT PIPE WIRING SYSTEM (WITH MODULAR TYPE ACCESSORIES) Derived from 34.01: Replacement of PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in existing heavy gauge welded conduit pipe 20 mm/25 mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- (Derived From CSR 34.01) |
| 2 | Wiring fan point (Without fan box) |
| 3 | Wiring light point |
| 4 | Wiring 6Amp. wall socket point |
| 5 | Wiring 6Amp. Plug control comprising wall socket point |
| 6 | Wiring 16/20Amp. power plug control point |
| 7 | Wiring light point without control switch. |
| 8 | Wiring light point with double control switches. |
| 9 | PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 10 | Overall size 1.5sq.mm (Un-sheathed) |
| 11 | Overall size 4sq.mm (Un-sheathed) |
| 12 | Overall size 6sq.mm (Un-sheathed) |
| 13 | Overall size 10sq.mm (Un-sheathed) |
| 14 | Overall size 16sq.mm (Un-sheathed) |
| 15 | XLPE INSULATED LT CABLES: XLPE INSULATED ARMOURED CABLES (ON SURFACE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- |
| 16 | Overall size 10sq.mm (2Core) Armoured (On-Surface) |
| 17 | Overall size 25sq.mm (3½ Core) Armoured (On-Surface) |
| 18 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 19 | Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface) |
| 20 | Heavy Gauge PVC Conduit Pipe 40mm dia. (On Surface) |
| 21 | COPPER EARTHING: 8 SWG COPPER EARTHING : Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 22 | Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 19.50 metre (63.96 feet) below ground level (up to 23metre in Length) with G.I. pipe 20mm dia. (A-class), 18metre long |
| 23 | BONDING TO EARTH WITH COPPER WIRE: Bonding to existing earth with copper wire in heavy gauge (1.6mm thick) welded conduit pipe with bends, junction boxes, steel hooks and MS saddle clamps including painting etc.:- |
| 24 | Bonding with copper wire 8S.W.G. (4mm dia) in HGW conduit pipe 20mm dia. (on surface) |
| 25 | MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's: MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 26 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 27 | MCB Double Pole 40amp. (10kA, Curve-C) |
| 28 | MCB Triple Pole 50, 63amp. (10kA, Curve-C) |
| 29 | MCB Four Pole 40amp. (10kA, Curve-C) |
| 30 | MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 31 | MCCB's (MOULDED CASE CIRCUIT BREAKER): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- |
| 32 | MCCB Four Pole 250amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 33 | MS SHEET ENCLOSURE FOR MCCB's: Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:- |
| 34 | MS Sheet Enclosure having provision for MCCB 200-630Amp.with extended rotary handle (Approx. Size 750mm x 300mm x 250mm) |
| 35 | TIMER: S/E of Microprocessor Based Street Light Controller with digital time switch daily programmed with stand by lithium battery with back up of 6 years with min. time between 2 switching operations is 1 minute, three pole power contactors 40A. with coil voltage 220-230V AC with 1 no. aux. contact NO, MCB 2 pole 40amp. (C-Curve, 10kA) & power wiring with single core PVC insulated FR cable 10 sq. mm and control wiring with PVC insulated FR cable 1 sq. mm, 1 no. two position selector switch to bypass timer and other accessories & petty material (din rail, 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) should be fixed on bakelite sheet 6mm thick to be mounted in a IP54 surface/ flush mounting powder coated sheet metal (1.60mm thick) cabinet having size 450mm x 600mm x 150mm to switch ‘ON’ all the 3 phases & switch ‘OFF’ 3 phases pre-fixed timings complete in all respect as per satisfaction of Engineer-in-charge:- |
| 36 | Street Light Controller (For Three Single Phase Circuits) with 3 Nos. Three Pole Power Contactors 40A, 1 no. aux. contactor 6 amp. (2NO+2NC) with coil voltage 220V AC, 3 Nos. MCB 2 Pole 40amp. (C-Curve,10kA) & petty material (Din rail, 2 Nos. 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) |
| 37 | Supply and erection of LED batten 40 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3% with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory |
| 38 | Supply and erection of BEE 3-star rating AC Celling Fan 1200mm (48\\") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body 3Nos of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air delivery of 218 CMM. The rated speed of the the product must be minimum of 350 revolutions per minute and 5Nos, of speeds. The product should have a manufcaturer's guarantee warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm comploto in all respects as per satisfcation of the Engineer In-charge at site. |
| 39 | Supply and erection of Heavy duty Exhaust Fan 300mm, 900RPM with aluminium louver shutter, double ball bearing longer ilfe including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at sile. Please Enable Macros to View BoQ information |