| 1 | Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in any type of soil. complete all as specified and as directed. |
| 2 | Excavating in post holes (or similar holes) each not exc. 0.5 Cum in any type of soil, getting out returning filling and ramming earth or broken rubble mixed with earth around, in layers not exc. 25 cm complete all as specified and directed. |
| 3 | Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed. |
| 4 | Plain Cement concrete type E-2, 1:5:10 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed. |
| 5 | Plain Cement concrete,Type B-2,1:2:4 ( Nominal mix) using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete includg necessary formwork complete,etc complete all as specified and as directed by Engineer-in-Charge. |
| 6 | M & L for hardcore of broken boulders of gauge exc. 63mm but n exc 100mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 7 | 150 mm thick cement concrete type D-2, 1:4:8 (40mm graded stone aggregate) as in sub base of flooring complete all as specified and directed. |
| 8 | 100 mm thick cement concrete type B-1, 1:2 :4 (20mm graded stone aggregate) as in flooring finished even and rough without using extra cement complete all as specified and directed. |
| 9 | Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade A complete all as specified and directed. |
| 10 | Forming Contraction joints 35mm deep x 10mm wide, filled with sealing compound Grade A complete all as specified and directed. |
| 11 | M & L for brickwork with subclass 'B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified and directed. |
| 12 | Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finish smooth & even without using extra cement complete all as specified and directed. |
| 13 | Preparation of new plastered surfaces and applying three coats of white washing complete all as specified and directed. |
| 14 | Cement concrete type C-1, 1:3:6(using 20mm graded crushed stone aggregates) in roof kerbs or mud stops ,rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses lacing courses, parapets and railing upto 60 cm in height, coping, kneelers, apex stones, bed plates kerbs, water troughs and like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 15 | Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. conforming to Fe.410.Gde-E-250 Quality A etc complete all as specified and directed. |
| 16 | Mild steel rag or lewis bolts or anchor bolts, of average neck dia 16mm screwed one end,with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, exc 30cm ,etc complete all as specified and directed. |
| 17 | Roof trusses (framed), trussed, purlin, crane gantried, rails and fastening and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe.410.Gde-E-250 Quality A complete all as specified and directed. |
| 18 | Pre painted galvanized corrugated mild steel sheeting 0.50 mm thick with coloured having tensile strength of 550 Mps as in roof covering with self tapping screws complete all as specified and directed. |
| 19 | Pre painted galvanized plain mild steel sheeting 0.50 mm thick with coloured having tensile strength of 550 Mps as in roof covering with self tapping screws complete all as specified and directed. |
| 20 | Preparation of new steel surfaces of any description over 10 cm width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 21 | Removing excavated material (any type) n exc. 50m depositing where directed at a level n exc. 1.5 m above the starting point complete aall as specified and directed. |
| 22 | Returning filling in including spreading levelling watering and well ramming in layers not exc. 25 cm thick each complete all as specified and directed. |
| 23 | Point wiring with multistranded copper conductor of size 1.5 sqmm PVC insulated unsheathed FRLS cable in and including PVC casing capping and assessories of suitable size including 1.50 sqmm copper earth wire (green colour) FRLS cable as earth continuity conductor connected to main earthing and common earth terminal for one ligh point or fan point or bell point controlled by one No, one way switch using cable of different insulation coloour for colour coding including 3 mm thick laminated sheet cover, mild steel or cast iron boxes including making good to distrubed surfaces of wall/ floor, complete all as specified and directed. |
| 24 | All as per the description of serial item No-23 here-in-before but for one 3 pin socket outlet 5 Amp on same board, complete all as specified and as directed. |
| 25 | LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED Tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 26 | Ceiling rose, 3 phase/PVC/Polycarbonate, isolated body and all as specified and directed. |
| 27 | Switch piano flush type 5/6 Amp single pole one way all as specified and directed. |
| 28 | Supply and fix in repair Socket outlet 2 in 1, 3 pin 5/6 Amp flush type complete all as specified and directed. |
| 29 | MCB DB 4 - way, single door, 240 volts for Sheet Steel, Phosphatised, Powder Painted MCB DBs with Bus Bar,Neutral Link, Earth Bar and Din Rail (In accordance with IS 13032, IS 8623, IEC/BSEN 60439-3) all specified and directed. |
| 30 | MCB SP 6-32 Amps 'C' series 240V 50Hz 10 KA suitable for lighting and other loads complete all as specified and directed. |
| 31 | MCB SPN 32 Amps 'C' series 240V 50Hz 10 KA suitable for lighting and other loads complete all as specified and directed. |
| 32 | Supply and laying dry river sand laid in trenches as cable cushoning, 80mm below and 150mm above the cable and punned to 180mm.Note:- Only punned thickness will be measured and paid. |
| 33 | Brick covering with width equal to length of brick as mechanical protction to cable with well burnt sub class 'B' brick, laid in trenches flat complete all as specified and directed. |
| 34 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 2 core complete all as specified and as directed. |
| 35 | Earthing of galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr depth below normal ground level) with top edge of earth not less than 1.5 mtr below normal ground level connected to and including earth lead wire 4.0 mm by means of steel bolts, nuts, check nuts and washers, test point made of GI strip 40x8mm, 10cm long PCC 1:2:4, type B-1 in pit with precast RCC 1:2:4 type B-1 in cover reinforced with XPM not less than 4 Kg per Sqm with 15mm bore GI light grade protection pipe, 20mm bore GI medium grade watering pipe with funnel including charcoal, dust, salt, all as shown in electric plate No 3 of SSR Part-I (2009) Specifications, complete with necessary earth work in any type of soil, removal to a distance not exceeding 50 mtr including testing on completion, complete all as specified & directed. Please Enable Macros to View BoQ information |