| 1 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed. |
| 2 | S&F anodised aluminium snap grid frame work (size of grid 605x605 mm) with 35x25x1.5 mm main tee and 25x25x1.4 mm cross tee and wall angle for false ceiling complete all as specified and directed. |
| 3 | S&F hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. |
| 4 | M&L for 4 mm thickness non-asbestos fibre cement building boards (decorative type) fixed or laid/ inserted to timber/ GI/ Aluminium framework with screws complete all as specified and directed. |
| 5 | Taking down chowkhats or frame exceeding 1.50 and not exceeding 4 sqm each with shutter (without taking off shutters from the frame) complete all as specified and directed. |
| 6 | Taking down shutters of any description exceeding 1 Sq.m but not exceeding 2 Sqm complete all as specified and directed. |
| 7 | Taking down shutters of any description not exceeding 1 Sq.m complete all as specified and directed. |
| 8 | S&F second class hardwood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed. |
| 9 | S&F 30 mm thick (shutter thickness) second class hard wood, plain, framed panelled shutters (any number of panels), with panels of 12 mm thick timber flat on both sides (feather edged), or of 12mm thick veneered particle board medium density, wood particle board with commercial face veneers complete all as specified and directed. (Note :- The dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I) |
| 10 | S&F 30 mm thick (shutter thickness) second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitered beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed. |
| 11 | Supply and fixing factory made uPVC white colour Three track three panels sliding door with fly proof S.S. wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 + 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 5.00 sqm) comprising of uPVC chambered frame, with in-built roller track and sash extruded profiles duly reinforced with 1.60 + 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) crescent lock (if required). stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fastener 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wire mesh shall be paid separately)Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 12 | S&F 4.80 mm thick sheet glass ordinary quality and glazing with oil putty in square exceeding 0.50 sqm in each pane complete all as specified and directed. |
| 13 | S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and directed. |
| 14 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 15 | S&F 200mm long aluminium anodised barrel tower bolts of extruded sections all as specified and directed. |
| 16 | S&F 300 mm length aluminium alloy, anodised, sliding door bolt with hasp, staples (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed. |
| 17 | S&F 100mm long butt hinges, medium weight, cold rolled mild steel complete all as specified and directed. |
| 18 | S&F 150mm size aluminium handles, cast type, anodised, complete all as specified and directed. |
| 19 | S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 20 | M&L for 18/ 19 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work as in cup boards with 6 mm thick teak wood lipping, fixed with screws all around including taking down old particle board complete all as specified and directed. |
| 21 | S&F in repairs continuous (Piano) hinges, mild steel bright finished or electrogalvanized, width of flaps (when open) 30 mm complete all as specified and directed. |
| 22 | S&F in repairs 150mm size aluminium anodised hasp and staple, safety type with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed. |
| 23 | S&F in repairs mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 24 | M&L for preparation of new wooden surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 25 | S&F in repairs curtain Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and directed. |
| 26 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed. |
| 27 | M&L for vitrified ceramic dark shade tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed or bedding layer in cement mortar (1:4) complete all as specified and directed. |
| 28 | M&L for vitrified ceramic dark shade tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, on vertical surfaces such as skirtings, dados and risers to steps etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed or bedding layer in cement mortar (1:4) complete all as specified and directed. |
| 29 | M&L for glazed ceramic coloured tiles in vertical surface 450x 300x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match laid over and including 10 mm thick backing on stone/ brick masonry surfaces in cement mortar (1:3) complete all as specified and directed. |
| 30 | Demolition of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar in floors, aprons etc. complete all as specified and directed. |
| 31 | M&L for Granite (of any type) tiles 20mm thick work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite laid over and including 20mm thick screed bed or bedding layer in cement mortar (1:4) complete all as specified and directed. |
| 32 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed. |
| 33 | Demolition of brick or stone /boulder masonry built in cement mortar or cement lime mortar, including all quoins, arches, pillars etc. but excluding ashlar facings, dressed stone work and pre cast concrete articles and removing debris outside MD land complete all as specified and as directed. |
| 34 | M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 35 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed. |
| 36 | M&L for rendering in two layers as 5 mm thick with cement mortar (1:4) mixed with water proofing compound @ 3% by the weight of cement over rendering 10mm thick with cement mortar (1:6) on fair faces of brick work in external surfaces of wall complete all as specified and directed. Note: Water proofing compound will be measured and paid separately. |
| 37 | M&L for rendering 10 mm thick cement plaster in cement mortar 1:6 on fair faces of brick work/ PCC solid block masonry/ concrete surfaces, finished fair and even complete all as specified and directed. |
| 38 | Supply only integral water proofing compound all as specified and as directed. |
| 39 | M&L for preparation of newly plastered wall surfaces and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed. |
| 40 | M&L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade Company Depot Tinted) with silicon additives 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 41 | S&F 15 mm bore Unplasticised PVC pipes ASTM 1784 Sch 80 class III and fittings of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe including taking down old pipe complete all as specified and directed. |
| 42 | S&F 20 mm bore Unplasticised PVC pipes ASTM 1784 Sch 80 class III and fittings of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe including taking down old pipe complete all as specified and directed. |
| 43 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exceeding 20 cm girth in brick walls complete all as specified and directed. |
| 44 | S&F rotational moulded polyethylene water storage tanks of 1000 ltrs capacity, triple layer (cylindrical vertical with closed top), white, hoisted and fixed in position all as specified in SSR Part I and 20 mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed and connecting inlet, outlet pipe lines, including taking down old water tank complete all as specified and directed. |
| 45 | S&F in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed suitable for 20 mm bore dia of pipe complete all as specified and directed. |
| 46 | Excavating in post holes (or similar holes) in hard/ dense soil each not exceeding 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not exc 50 m and making good surface complete all as specified and directed. |
| 47 | M&L Plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed. |
| 48 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed. |
| 49 | M&L for preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 50 | S&F in repairs vitreous china wash down water closet pan S and P trap (pedestal pattern), white including fixing bolt, plastic water closet seat, white, or black colour, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device (excluding flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe, anti syphonage etc complete all as specified and directed. |
| 51 | S&F in repairs 10 ltrs capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and including 32 mm bore PVC flush pipe complete all as specified and directed. |
| 52 | S&F in repairs wash basin, vitreous china (flat back), size 630 mm x 450 mm, white including cutting for and pinning in ends of brackets or erecting stand with waste pipe including PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed. |
| 53 | S&F in repairs stop valve, cast copper alloy, chromium plated, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for unions or fixed for 15mm bore dia of pipe complete all as specified and directed. |
| 54 | S&F in repairs stop valve, cast copper alloy, chromium plated, fancy type, with long shank and cup (concealed type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for unions or fixed for 20mm bore dia of pipe complete all as specified and directed. |
| 55 | S&F in repairs looking mirror, size 600mmx450mm, bevelled edge, selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers with aluminium edging around mirror complete all as specified and directed. |
| 56 | S&F in repairs brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. |
| 57 | S&F in repairs bib tap cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for 15mm bore dia iron pipe/ PVC pipe or for brass ferrule complete all as specified and directed. |
| 58 | S&F in repairs pillar taps of size 15mm bore dia, cast copper alloy, fancy type, with capstan heads, chromium plated, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly-nuts screwed for iron pipe complete all as specified and directed. |
| 59 | S&F in repairs PVC connections 15mm size, 600mm length with 02 Nos PTMT nuts with washer etc complete all as specified and directed. |
| 60 | S&F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 61 | S&F in repairs chromium plated brass shower roses 125 mm size with or without swivel joints including fixing to steel/ PVC pipe or union complete all as specified and directed. |
| 62 | S&F in repairs mild steel chromium plated grating 100 mm dia. complete all as specified and directed. |
| 63 | S&F in repairs 32 mm dia waste fittings, brass, chromium plated for glazed ware sinks, wash basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed. |
| 64 | S&F in repairs sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 65 | S&F sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 66 | S&F in repairs 40mm dia PVC flexible waste pipe 90 cm long with union for WHB/ sink complete all as specified and directed. |
| 67 | S&F in repairs floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, (overall length of cover plate 150mm) fixed in floor complete all as specified and directed. |
| 68 | S&F in repairs 110 mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints or jointing with solvent cement, laid in trenches or in floors complete all as specified and directed. |
| 69 | S&F in repairs 110 mm bore PVC (SWR) bend any radius complete all as specified and directed. |
| 70 | S&F in repairs 110mm bore PVC (SWR) single T junction equal or unequal with access door complete all as specified and directed. |
| 71 | S&F in repairs 110 mm bore PVC (SWR) bend any radius with access door complete all as specified and directed. |
| 72 | S&F in repairs 110 mm bore PVC (SWR) vent cowl including solvent cement complete all as specified and directed. |
| 73 | M&L for RCC NP3 sewer line 150 mm dia of pipe laid on 150 mm thick PCC 1:4:8 bed with excavation in any type of soil, including manholes/ drop manholes of standard size made of brick masonry/ RCC/ precast RCC with SFRC ventilating cover and frame includes all items and activities to execute and make sewer line functional all as per direction of Engr-in-charge. |
| 74 | Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) and removing debris outside MD land complete all as specified and as directed. |
| 75 | M&L for 75mm thick PCC 1:3:6, Type C2 (using 40mm graded stone aggregate) as in plinth protection and finishing cement concrete surface even and smooth with using extra cement complete all as specified and directed. |
| 76 | M&L for 75mm thick PCC 1:2:4 type B-2 (using 40 mm graded crushed stone aggregate) as in sub-base complete all as specified and directed. |
| 77 | M&L for coloured and polished chequered cement concrete tiles 40cm x 40cm x 25mm thick, set, jointed and pointed in neat cement slurry as in floors with grey pigment cement and pigments, including 15mm thick screed bed in CM 1:4 complete all specified and directed. |
| 78 | S&F in repairs PVC (SWR) floor trap, outlet 75 mm dia, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 79 | S&F PVC ventilator fixed type with solid frame of size 70mm x 45mm including louvers, frosted glass 3mm thickness, including MS guard bars of 10mm dia spacing 150 mm C/C and stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with PVC beading including synthetic enamel painting to steel surfaces. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size, including taking down old ventilator complete all as specified and directed. |
| 80 | M&L 25 mm thick PCC type B-0, (1:2:4) using 12.5 mm graded stone aggregate as in floors, sub base and base as levelling course complete all as specified and directed. |
| 81 | M&L for non - skid ceramic coloured joint free tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 20mm thick screed bed or bedding layer in cement mortar (1:4) complete all as specified and directed. |
| 82 | Taking up or down 25 mm or 32 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 83 | S&F 25 mm bore Unplasticised PVC pipes ASTM 1784 Sch 80 class III and fittings of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe including taking down old pipe complete all as specified and directed. |
| 84 | S&F in repairs stop valve, cast copper alloy, chromium plated, fancy type, with long shank and cup (concealed type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for unions or fixed for 15mm bore dia of pipe complete all as specified and directed. |
| 85 | S&F in repairs wash basin, vitreous china (flat back), size 550 mm x 400 mm, white including cutting for and pinning in ends of brackets or erecting stand with waste pipe complete all as specified and directed. |
| 86 | S&F in repairs toilet paper holder with flat recessed type stainless steel complete all as specified and directed. |
| 87 | S&F in repairs brass chromium plated towel ring round/ square complete all as specified and directed. |
| 88 | Demolition and breaking up 150/ 160 mm internal dia drain pipes (Salt glazed ware, AC or reinforced concrete) set in cement mortar complete all as specified and directed. |
| 89 | S&F 110 mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints or jointing with solvent cement, fixed to walls complete all as specified and directed. |
| 90 | S&F 75 mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints or jointing with solvent cement, laid in trenches or in floors complete all as specified and directed. |
| 91 | S&F 75 mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints or jointing with solvent cement, fixed to walls complete all as specified and directed. |
| 92 | S&F 110mm bore PVC (SWR) single T junction equal or unequal complete all as specified and directed. |
| 93 | S&F 75mm bore PVC (SWR) single T junction equal or unequal complete all as specified and directed. |
| 94 | S&F 75 mm bore PVC (SWR) bend any radius complete all as specified and directed. |
| 95 | M&L for special treatment of sunken portion of WCs and bath room as per following stages and all as per the direction of Engr-in-charge.Stage 1 : Demolition of WC including lime concrete and cement concrete and preparing the surface of existing sunken portion of WCs or bath etc with wire brush to remove all loose dirt, oil grease, etc.Stage 2 : Applying two coats of each 1 mm thick of polymer modified cementitious water proofing coating as per IS 2645-2003 to bottom and sides up to FFL +100 mm height.Stage 3 : 20 mm thick plaster in CM 1:4 mixed with integral water proofing compound including forming angle fillet at junctions of size 40 mm x 40 mm using polymer modified mortar.Stage 4 : Test the water proofed area by filled with water for atleast 72 hours and to the entire satisfaction of GE.Stage 5 : Sunken portion to be filled with lean concrete 1:4:8Stage 6 : All sewage pipe joints shall filled with mixture of cement fine sand and plaster seal of STP Ltd or Dr. Fixit pidicrete URP. |
| 96 | Taking down carefully copper/ aluminium point wiring of light, fan, socket or power socket complete, including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of walls, floor ceiling etc, match the existing complete all as specified and directed. Please Enable Macros to View BoQ information |
| 97 | Taking down carefully copper/ aluminium point wiring of light, fan, socket or power socket complete, including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of walls, floor ceiling etc, match the existing complete all as specified and directed. Please Enable Macros to View BoQ information |