| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. (D.S.R 2.8.1) |
| 2 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 mte lead 15.56 |
| 3 | 12 mm thick plaster with 1:6 cement and coarse sand morter on brick work including ranking and joint washing and cleaning and including supply of all materials labour and T&P etc. required for proper completion of work. (D.S.R.13.5.2) |
| 4 | Dismantling tile work in floors and roofs laid in cement morter including stacking material within 50 meter lead .For thickness of tiles 10 mm to025 mm(D.S.R 15.23.1) |
| 5 | providing and laying in position cement concrete of specific grade excluding the cost of centering -All work up to plinth level 1:4:8 (1 cement : 4 coarse sand (zone-III) derived from natural sources :6graded stone aggregate40 mm nominal size Recycled Aggreate (RA) ) s per (D.S.R 4.1.8) |
| 6 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in 6 coarse sand) Cement mortar 1:6 (1 cement (DSR.6 1.2 |
| 7 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement All work up to plinth level 1:15:3 (1 cement 15 coarse sand (zone 3 graded stone III) derived from natural sources aggregate 20 mm nominal size derived from natural sources) For plinth Beam (D S.R 5.3 |
| 8 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in super structure and plinth in 6 coarse sand) Cement mortar 1:6 (1 cement (DSR.6.4 |
| 9 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm As per (D.S.R 11.41.2) |
| 10 | cement concree fiooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate ) finished with a floating at coat of neat cement , including cement slurry, but excluding the cost of nosing of steps etc completed .(D.S.R.11.3) |
| 11 | Removing white or colour wash by scraping and sand paperinhg and preparing the surface smoothe including necessary repairs to scratches etc. complete (D.S.R.13.88) |
| 12 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colourNew work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less then 50 gram/litre (D.S.R.13.41.1): |
| 13 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture (D.S.R.13.48.2) |
| 14 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) (D.S.R.13.47.1) |
| 15 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (D.S.R.9.21.1) |
| 16 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement All work up toor beam, roofs, lintel band & etc above plinth level. 1:15:3 (1 cement 15 coarse sand (zone 3 graded stone III) derived from natural sources aggregate 20 mm nominal size derived from natural sources) (D S.R 5.3 |
| 17 | Steel Reinforcement for R.C.C work including cutting,straightening bending binding and placing in position & including complete. Thermo-Mechanically Treated bars of grade Fe-500D or more. (D.S.R.5.22.6 |
| 18 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0mm thick glass panes D.S.R 10.30.1 |
| 19 | Wiring for light point/ fan point/ exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper onductor single core cablein surface recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. DSR NO. 1.10 |
| 20 | Wiring for light/ power plug with 2X4 sq mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper |
| 21 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required DSR NO 1.14 |
| 22 | 2 X 1.5 sq mm+1 X 1.50 Sq mm earth wire DSR NO1.14.1 |
| 23 | 2 X 2.5 sq mm+1 X 1.50 Sq mm earth wire DSR NO1.14.2 |
| 24 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. DSR NO. 1.24 |
| 25 | 5/6 A switch DSR NO. 1.24.1 |
| 26 | 15/16Aswitch DSR NO. 1.24.3 |
| 27 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular piate switch box including connections but excluding modular plate etc, as required. DSR NO. 1.25 |
| 28 | Supply and Celling fan with fan motor of AC permanent insulation, capacitor rating conforming BEE 5 star rating and IS: 374/79 and also comply with S:1709/1984 with latest amendment. The rated voltage 220/240 vait 50Hz 1-ph AC the fan assemble should consist of down rod blades, shackle canopies etc and with double ball breaing system. DSR NO. 19.1 |
| 29 | Providing & fixing white vitereous china water closet squatting pan ISI marked (Indian type W.C. pan) with 100mm sand cast iron P or S trap, 10/12.5 litrs PVC low level flushing cistern with fittings & brackets 40mm dia C.P. flush pipe with fitting & clamps, 20mm over flow pipe with specials and mosquito proof coupling of approved municipal design, painting wherever required including cutting & making good the walls & floors where required.a)Orissa Pattern W.C. pan of size 580x 440m with integral type foot rests flush pipe and over flow arrangement.D.S.R 17.1.1 |
| 30 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap D.S.R 17.7.4 |
| 31 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 32 | (a) 32 mm diaD.S.R 17.28.2.1 |
| 33 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. |
| 34 | (a) 20 mm dia nominal bore D.S.R 18.10.2 |
| 35 | (b) 15 mm dia nominal bore D.S.R 18.11.1 |
| 36 | Providing and fixing brass stop cock of approved quality : |
| 37 | (b) 15 mm dia nominal bore |
| 38 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 39 | 15 mm dia nominal bore |
| 40 | Supply and fixing of sign board including supply and cost of all materils labours T & P etc. required templet as directed by the Engineer In charge. |
| 41 | GST 18 % Please Enable Macros to View BoQ information |