| 1 | Earth work in excavation in foundations, trenches etc. In all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches , stacking the excavated soil clear from the edge of excavation and subsequent filling around masonary in 15 cm layers with compaction including diposal of all surplus soil as directed within a lead of 30 metres. |
| 2 | Dismantling brick work tile, masonry or tile lining : In cement . |
| 3 | Scraping Bricks dismantled from brick work in lime or cement. |
| 4 | Shuttering for faces of concrete foundations and foundationbeam & plinth beam (vertical or battering) |
| 5 | Centering and shuttering for columns (Square or rectangularor poly gonal in plain) |
| 6 | Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels |
| 7 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 8 | Cement Concrete 1:6:12 with stone aggregate 40mm gauge(mixing by mechanical means using concrete mixer volumetric type) |
| 9 | Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 10 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. |
| 11 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS : 1791 and vibrated by needle vibrator but excluding steel reinforcement centering and shuttering in superstructure . |
| 12 | Damp proof course 7.5 cm thick of cement concrete 1: 2: 4 with two coats of bitumen 20/30 penetration at 1.65 kg per sqm laid hot and sanded. |
| 13 | First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth |
| 14 | First class burnt brick laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 15 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth |
| 16 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another laver of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg/sqm top of RCC slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing . |
| 17 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16 |
| 18 | Bottom Khurra on ground 1.2mx0.6m consisting of brick on edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5mm thick cement plaster 1:3 |
| 19 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 20 | Providing and Fixing ceiling at height upto 4 mtr. consisting of 12.5mm thick Gypsum Board of any size G.I. Cradling hanged from the ceiling by means of G.I. hanger complete as per drawings,specifications and to the entire satisfaction of engineer-in- charge. |
| 21 | Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. |
| 22 | Providing and fixing 110 mm dia UPVC bend for rain water pipe as per IS : 14735 including jointing as per specifications and to the entire satisfaction of Engineer-in-charge. UPVC 110 mm bend |
| 23 | Water proofing treatment of Roof Slab with High performance cementitious two component product, consisting of a powder component and an acrylic polymer using two coats ( Dr Fixit Roofseal flex - Packaging Size: 12 .5 kg (7.5 kg powder + 5 kg polymer) / equivalent water proofing Solution ). The slurry thus formed by mixing the two, is to be applied on new roofs to forms a seamless, highly elastic, non-toxic waterproofing layer on the roof with a life expectancy of 7 years. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. |
| 24 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge and 100 mm fine sand filling using mechanical mixer for mixing of material |
| 25 | Conglomerate floor 40mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material |
| 26 | Flat brick or tile flooring laid in cement sand mortor 1:4 on 100mm thick cment concret 1:8 :16 and 100mm thick sand filling and cement pointed 1:2 on top. |
| 27 | Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete.Size 600x600 mm |
| 28 | 12.5 mm thick cement plaster 1:4 |
| 29 | 12.5 mm thick cement plaster 1:5 |
| 30 | 20 mm thick cement plaster 1:4 in two coat work |
| 31 | 20mm thick cement plaster 1:5 in two coat work |
| 32 | Plastering on underside of ceiling 10mm thick cement plaster 1:4 |
| 33 | 20mm thick cement plaster in damp proof course 1:3 with two coats of bitumen at 1.65Kg. Per Sqm laid hot and sanded Vertical |
| 34 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface |
| 35 | Finishing walls with acrylic smooth exterior paint of required shade with two coats applied@ 1.67 litre/10sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 sqm |
| 36 | Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats) |
| 37 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two coats to get required finish |
| 38 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm |
| 39 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete I.S.I Designation No. III (size of door 851mm to 1000mm) |
| 40 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. Glazing and paneling to be paid for separately) : For fixed portion and chawkhats |
| 41 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. Glazing and paneling to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug /neoprene gasket required |
| 42 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) Float glass panes of 5 mm thickness |
| 43 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece MS sheet outer box with slide plate and with stainless steel cover plate etc. complete as per the direction of Engineerin- charge. |
| 44 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250mm x 16mm |
| 45 | Cold twisted detormed (Ribbed/ ToR S teel Bar) Bars (Fe 500 grade as per IS 1786-1985) , for R.C.C works, where not including in the complete rate of RCC including bending and biding placing in position complete. (Labour Rate) |
| 46 | Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work. |
| 47 | Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 48 | Wiring fan point (with fan box) |
| 49 | Wiring light point |
| 50 | Wiring 6Amp. wall socket point |
| 51 | Wiring 16/20Amp. power plug control point |
| 52 | PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 53 | Overall size 1.5sq.mm (Un-sheathed) |
| 54 | Overall size 2.5sq.mm (Un-sheathed) |
| 55 | Overall size 4sq.mm (Un-sheathed) |
| 56 | HEAVY GAUGE WELDED CONDUIT PIPES: Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- |
| 57 | HGW Conduit Pipe 25mm dia. (1.6mm thick) On Surface |
| 58 | MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's: MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 59 | MCB Single Pole 0.5-4amp. (10kA, Curve C) |
| 60 | MCB Double Pole 50, 63amp. (10kA, Curve-C) |
| 61 | Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- |
| 62 | SP&N Double Door Distribution Board 12 way each |
| 63 | Supplying and Fixing General Purpose tube Fitting of 20 watts LED of Havells make. |
| 64 | Supplying and fixing Ceilimg Light of 42 watt 2'*2' fitting of havells make. |
| 65 | Providing & Fixing of ceiling fan 1400mm sweep with regulator of crompton make. |
| 66 | Supplying and fixing exhaust fan 12” sweep of Crompton Make including louver ( MODEL T5JB1328EB) of 1x28 W T-5 |
| 67 | Supplying and fixing exhaust fan 18\\" sweep of Crompton Make including louver (MODEL T5JB1328EB) of 1x28 W T-5 |
| 68 | Providing and fixing wire gauge 12*22 size in aluminium section without cost of aluminium beading in section. |
| 69 | Providing & Fixing 30X30X3mm Angle Iron nosing for indoor cable trenches |
| 70 | Providing & Fixing MS checquered plate 5mm thick |
| 71 | Providing & Fixing Cable Racks of various sizes |
| 72 | Recovery of bricks |
| 73 | Recovery of brick bat |
| 74 | Recovery of Aluminium window |
| 75 | Extra Carriage of material- Cement |
| 76 | Extra Carriage of material- Steel |
| 77 | Extra Carriage of material- Fine sand |
| 78 | Extra Carriage of materials & diff. of rates of material- Coarse Aggregate 12/13.2 mm |
| 79 | Extra Carriage of materials & diff. of rates of material- Bricks |
| 80 | Extra Carriage of materials & diff. of rates of material- Coarse Aggregate 10/11.2 mm |
| 81 | Extra Carriage of materials & diff. of rates of material- Coarse Sand |
| 82 | Extra Carriage of materials & diff. of rates of material- Stone metal 40mm |
| 83 | Extra Carriage of materials & diff. of rates of material- Tiles Please Enable Macros to View BoQ information |