| Sl. No. | Item Description |
| 1 | Taking down cement plaster on brick or stone walls, etc, including raking out joints, hacking for key, scrubbing down with water, etc |
| 2 | Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 with water proofing compound finished fair and even complete all as specified and as directed.Note water proofing compound shall be measured separately |
| 3 | Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished fair and even complete all as specified and as directed |
| 4 | Preparing newly plastered surfaces of wall and applying two coats of cement base paint complete all as specified and as directed |
| 5 | Preparing newly plastered surfaces of wall and applying two coats of distemper oil emultion over a coat of JK/Birla wall care putty complete all as specified and as directed |
| 6 | Preparing newly plastered surfaces of wall and applying three coats of white wash complete all as sppecified and directed. |
| 7 | Demolition of cement concrete in ground floor and paving n exc 15cm thickness (below or above the ground level) built in cement mortar, complete all as specified and as directed. |
| 8 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed. |
| 9 | M&L for Non-skid cermaic coloured tiles (mat flooring) Size 300X300X7 to 8mm thick, in each floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1.6 complete all as specified and as directed. |
| 10 | M&L for Coloured Glazed ceramic tiles 450x 300 x 7 mm thick, on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match including 10mm thick redering in CM 1.4 on wall complete all as specified and as directed |
| 11 | M&L flor Jointless Non-skid cermaic tiles 7 to 8mm thick (squre/rectanglar) are of each tiles 600MMX600M, in each floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6, complete all as specified and as directed. |
| 12 | M&L 75 mm thick cement concrete type C2 1:4:8 (using 40 mm graded stone agg) in sub base of flooring/ hard standing and plinth protection, complete all as specified and as directed. |
| 13 | M&L for 75mm PCC 1:36 type C-1 using 20mm graded stone aggregate as in plinth protection, laid in alternate panels not more than 3 mtr in length, laid to slope 1:30 finished even and smooth without using extra cement with provision of forming joints duly filled with bitumen mastic, complete all as specified and as directed. |
| 14 | Taking up or down 15 mm bore steel tubing and connections, including cleaning for Refixing or removal to store, complete all as specified and as directed. |
| 15 | Taking up or down 20 mm bore steel tubing and connections, including cleaning for Refixing or removal to store, complete all as specified and as directed. |
| 16 | S & F 15 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc, fixed to walls and ceilings or laid in floors, complete all as specified and as directed. |
| 17 | S & F 20 mm bore Galvanized Steel tubes, medium grade for flush pipes,water supply pipes etc., fixed to walls and ceilings or laid in floors, complete all as specified and as directed. |
| 18 | S & F in repairs 15 mm bore Bib taps, fancy type cast copper alloy,chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule (Make > Cera (1st Quality), Parry ware (super fine), Hindware (1st Quality), complete all as specified and as directed. |
| 19 | S & F in repairs 15 mm bore Bib taps long body fancy type cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and as directed. |
| 20 | S & F in repairs 15 mm bore stop/angle cock fancy type,chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and as directed. |
| 21 | S&F in repairs 15 mm bore conceild stop cock fancy type,chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and as directed. |
| 22 | S&F 500 litres capacity Rotational moulded polyethylene water storage tanks ,white colour (Cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia PVC float valve (Make paryag) complete all as specified in SSR Part 1 including disconnectiong of existing tank, complete all as specified and as directed. |
| 23 | S&F in repairs 20 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and foxed complete all as specified and as directed. |
| 24 | S&F in repair Vitreous China wash basin, white, flat back, size 580x450mm excluding taps. waste chain and plug and porcelain stopper but including brackets, CP waste copling, including PTMT PVC connection 600mm complete all as specified and as directed . |
| 25 | S&F in repair 15 mm brass mixture fancy type,chromium plated for mixing hot & cold water with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed. |
| 26 | S&F in repair Chromium plated shower rose 125 mm size with or without swivel joints, any size. including fixing to steel pipe or union, complete all as specified and as directed. |
| 27 | Supply and Fix in repairs 10 Litres, PVC, valve less, syphonic action type, Flushing Cistern, high level, white inlet, ball valve, float, chain and pull, and brackets including PTMT PVC connection 600mm long, complete all as specified and as directed. |
| 28 | S&F in repair Styainless steel Towel Rail 600mm Long fixed with and including chromium plated brass screws, complete all as specified and as directed. |
| 29 | Supply & Fix in repairs Vitreous China Squatting pan, 'Orissa' pattern, size 580 x 440 mm white with integral foot rests, complete all as specified and as directed. |
| 30 | Supply 600mm x 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and as directed. |
| 31 | M&L for Green marble18/20 mm thick in steps , pillars, window cills, pillars, cooking platform and like laid jointed in neat cement slurry mixed with pigment to match the shade of slab includding rubbing and polishing complete all as specified and as directed |
| 32 | Taking down eaves gutter and rain water pipes including all fittings any size and pattern, complete all as specified and as directed. |
| 33 | S&F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls/trench, complete all as specified and as directed. |
| 34 | S&F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls/trench, complete all as specified and as directed. |
| 35 | S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified and as directed |
| 36 | S&F 75 mm bore PVC (SWR) bands of any radius complete all as specified and as directed |
| 37 | S&F 110 mm bore PVC (SWR) junction single (Single \\"T\\") equal or unequal, complete all as specified and as directed. |
| 38 | S & F 75 mm bore PVC (SWR) junction single (Single T') equal or unequal, complete all as specified and as directed. |
| 39 | S & F PVC Floor trap of 75 mm outlet with grating including jointing to waste pipe in run lead, complete all as specified and as directed. |
| 40 | Plain Cement Concrete Type C1 (1.2.4)(using 20 mm graded stone aggregate) cast in sit in lintels up to 1.5 M span, cills and other similar bands, plinth courses, parapets, copings bed plates hold fast and the like including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work, complete all as specified and as directed. |
| 41 | Taking down Chowkats or frames exceeding 15 Sq. M but not exceeding 4 Sq. M each (Without taking off shutters from the frame), complete all as specified and as directed. |
| 42 | Taking down Chowkats or frames Not exceeding 1.5 Sq. M each (Without taking of shutters from the frame), complete all as specified and as directed. |
| 43 | S&F Mild steel Angles, bars, flats etc., as in supports for stiffening of fencing, wall ties,hold fasts, clamps, plain angle cleats for securing purlins and similar small articles confirming to Fe 290 GdeE-165, complete all as specified and as directed. |
| 44 | S & F 35 mm thick Second class hard wood Glazed and skeleton shutters, open rebate and prepared to receive glass, gauze, etc, (without sash bars), edges of framing plai chamfered or rounded, fitted with cut mitred beads for securing glass etc, complete all as specified and as directed. |
| 45 | S&F 35 mm thick factory made flush shutters solid core construction with block board core and plywood face panels, commercial type on both side complete all as specified and as directed |
| 46 | S&F Solid PVC door frame of size 50mmx47 mm single side prefam PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with prelam sheet PVC sheet reinforced with MS square tube, supplying & fixing in opening as per specification & drawing complete all as specified in SSR Part-Il 2010 section 8, complete all as specified and as directed. |
| 47 | S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prefam PVC Sheet on back face, supplying & fixing in frame at site as per specification & drawing, complete all as specified and as directed. |
| 48 | S&F 100mm Butt hinges, alumum cast type, and fixed, complete all as specified and as directed. |
| 49 | S&F 150 mm long aluminum handles cast type, complete all as specified and as directed. |
| 50 | S&F 200 mm long aluminum barrel tower bolts of extructed section section, complete all as specified and as directed. |
| 51 | S & F 250 mm long mild steel sliding door bolts,plate type, stove enamelled bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four black,with on bolt plate and two on staple plate, complete all as specified and as directed. |
| 52 | S&F Floor door stopper140 mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, complete all as specified and as directed. |
| 53 | Preparation of New or previously untreated wood and wood based surfaces of description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer, complete all as specified and as directed. |
| 54 | S&F Box type steel windows with 80x40x1 25mm MSRectangular hollow section frame with side hung shutters (double shutters for glass and gauze) with out sash bars jointed together with and including grills using 12mm square bars @ 10cm C/C Ref TD No CEBZ/TD/14/2011 including box type hinges with steel handle and steel peg stay complete with glazing bars dovetailed and welded complete all as specified and as directed |
| 55 | S&F Box type steel Ventilator with 80x40x1.25mm MS Rectangular hollow section with side hung shutters (double shutters for glass and gauze) with out sash bars jointed together with and including grills using 12mm square bars @ 10cm C/C Ref TD No CEBZ/TD/14/2011 including box type hinges with steel handle and steel peg stay complete with glazing bars dovetailed and welded complete all as specified and as directed |
| 56 | Preparation of New or previously untreated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel pain (Ordinary tint) over a coat of red oxide, complete all as specified and as directed. |
| 57 | S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in squares not ex 0.5 Sqm in each pane complete all as specified and as directed |
| 58 | S&F stainless steel wire cloth 0.71 mm nominal dia of wire and average width of apertur 1.40 mm fixed with tinned tacks or galvanized wire staples complete all as specified an directed |
| 59 | S&F for stainless steel kitchen plate rack size 750x 600x230 mm including fixing arrang ment to walls with rawel plug or wooden plugs, complete all as specified and as directed. |
| 60 | S&F sinks with drainage board made of stainless steel 1mm thick kitchen or laborator with plugs, washers and waste cupling, wastepipe, including bedding in cement mortar dwarf wall or including foxing cantilever brackets and connecting union to pipe overall siz 915mm x 460mm bowl size 410mm x 330mm x 160mm, complete all as specified and as directed. |
| 61 | M&L for stainless steel curtain rod 25mm dia steel pipe cutting in to length required at site and fixed to brackets complete all as specified and as directed. |
| 62 | Demolition of brick work or stone/ boulder Masonry, built in cement mortar including quoins, pillars etc, complete all as specified and as directed. |
| 63 | M&L for Brick work with fly ash bricks, straight or curved on plan exceeding 6 M me radius built in cement mortar 1:6, complete all as specified and as directed. |
| 64 | M&L for Brick work with fly ash bricks, straight or curved on plan to any radius radius half brick thick wall built in cement mortar 1:4, complete all as specified and as directed. |
| 65 | Demolition of RCC Not exc 15cm thickness Roofs, floors (other than ground floors), bea staircases, landing, chajjas, and similar suspended work, complete all as specified and as directed. |
| 66 | M&L for RCC Type B2 1.1.5:3 (20 mm stone agg) Slabs supported on walls, beams a columns in floors, roofs, landings, balconies, chajja, canopies, deck slabs and in shelv and the like, complete all as specified and as directed. |
| 67 | M&L for mild steel deformed TMT bars 5 mm To 10mm dia (as in reinforcement) cut to length, bent to shape require including cranking, bending spirally for hooking for column hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia, complete all as specified and as directed. |
| 68 | Form work to soffits of suspended slabs such as roof slabs, floor slabs and lintels, chajja landing and similar work n exc 200mm thick, complete all as specified and as directed. |
| 69 | Dismantling of wall and ceiling board (fibre, pulp, insulation etc) or insulation boards/ slabs/blankets, any thickness, including cover fillets complete all as specified and as directed |
| 70 | S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre, complete all as specified and as directed .. |
| 71 | S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by eans of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold steners 12.5mm dia. 40mm long complete all as specified |
| 72 | Dismantling Asbestos Cement Corrugated or Semicorrugate in Roof covering, complete all as specified and as directed. |
| 73 | S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ro covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 74 | M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35e with grey cement and pigment including 50mm sand cushioning. including CM (1:3) in edges of pavers complete all as specified and as directed |
| 75 | Dismantling timber scantling 40 Sqcm and over in section in any position as in framed funframed works such as roof purlins, rafters, fillets ridges etc as in celling complete all as specified and as directed |
| 76 | Dismantling wrought iron or mild steel work of any description not otherwise provided all as directed and as directed |
| 77 | M&L mild steel work as roof trusses (framed) trussed, purlins, crane gantries rails and 5 fastenings and heavy brackets framing (beams, tee, angle, channels or flat sections) etc complete all as specified and as directed |
| 78 | Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for laying of pipe line or for manholes not exceeding 10 Sqm on plan and not exceeding 1.5m in depth in hard/dense soil and getting out complete all as specified and as directed. |
| 79 | All as per srl item No 78 above but depth exc 1.5m and not exc 3.00m, complete all as specified and as directed. |
| 80 | Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil all as specified and directed. |
| 81 | Removal of excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and directed. |
| 82 | M&L Concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested in cement concrete 1:3.6 type C-2 (Nominal mix) using 20 mm graded crushed stone aggregate for 150 mm bore pipes, complete all as specified and as directed. |
| 83 | M&L Salt glazed stoneware (SGSW) drain pipes 150 mm-bore laid and jointed on concrete bed, complete including testing etc. all as specified. (Concrete bed shall be measured and paid for separately). |
| 84 | M&L Cement concrete 1:3:6, type C-2 (Nominal mix) using 40 mm graded crushed stone aggregates in foundation filling and mass concrete complete all as specified and as directed. |
| 85 | M&L Cement concrete M-15 (Nominal mix) using 20 mm graded crushed stone aggregate in coping, benching and the like including weathering, slightly rounded or chamfered angles as directed including form work and finishing all exposed surfaces complete all as specified and as directed. |
| 86 | M&L for Precast cement concrete type B-1, 1:24 (Nominal mix) using 20 mm grade crushed stone aggregate, as in cover slabs (for manhole etc.) casted at site and setting incement mortar 1:4 complete all as specified and as directed. |
| 87 | Use & waste of form work to soffits of suspended slabs, floor slab etc not exc. 200 mm thick in flat all as specified and directed. |
| 88 | Use & waste of form work to edges of concrete flats etc exc. 5 cm but not exc. 10 cm wide/thick all as specified and directed. |
| 89 | Cutting into existing manholes for connecting new drains, internal dia of pipe150 mm, making good to pipes and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:24 type B-1 smooth finished, and reforming benching as required complete all as specified and as directed. |
| 90 | S&F in replacement 75mm bore sand cast iron soil waste and vent pipes ISI marked in any length with or without ears fixed to walls with clamps and cement joints all as specified and directed. |
| 91 | S&F in replacement CI bend or reducer/ taper of 100mm bore including cement joints complete all as specified and as directed. |
| 92 | S&F 25mm thick flush shutter for cup board solid core construction with block board core and plywood face panels commercial type on both sides etc with and inci min 5 mm thick wooden beading fixed all around complete all as directed |
| 93 | S&F 18mm thick prelaminated MDF board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work in any situation as in cup board shelves/shutter or similar work, complete all as specified and as directed. |
| 94 | S&F continuous (piano) hinges, mild steel bright finish in electro galvanized width of flat (when open) in 30mm, complete all as specified and as directed. |
| 95 | Demolition existing water proofing treatment by brushing with wire brush, cleaning of terracing by taking down cement concrete, existing plaster lime cova 80 to 100mm thick mud phuska/cement concrete/lime cova etc, cleaning of all foreign material such as fungus mass dust etc, roughing surface of comer to roof by wire brush complete all as specified and as directed. |
| 96 | M&L for PCC 1:24 type B-1 using 20 mm graded stone aggregate as in padding roof kerbs, complete all as specified and as directed. |
| 97 | Supply only liquid water proofing compound, mixed in CM as per manufacturer instruction, complete all as specified and as directed. |
| 98 | M&L of water proofing treatment to non-accessible roof slab with / applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers by Graco tex sprayer having sun reflective index (SRI) of 105 Mfd by Asian paint Ltd / Berger and Equivalent as approved by GE in three coats laid as per manuacturer's instructions complete all as specified and as directed by Engineer-in-Charge with following course of description below.(a) 10 mm thick plaster in CM 1:4 with WPC will be applied over the roof slab when concrete is green. After the plaster is cured the roof will be tested for water tightness by ponding with water for seven days for any seepage is observed the rectification will be carried out by pressure grouting under the pressure of 5kg/sqcm using cement based cement grout After the surface is repaireds the slab will be tested for water tightness again before proceeding with further treatment.(b) the surface of roof, parapet and gutters, drain mouths, etc. over which waterproofing treatment is to be applied shall be cleaned of all foreign matter such as, fungus, moss, dust etc by wire brushing and dusting For cast iron drain out lets a grove shall be cut around to tuck in the treatment Concrete angle-fillets shall be provided at junctions between roofs and vertical faces of walls (parapet and other walls) around obstacles such as pipes, chimney stacks, etc and other similar situation to ease up about corners. |
| 99 | (c) 1st coat of self priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1)(d) 2nd & 3rd coat of undiluted elastomeric water proofing liquid(dry film thickness of complete allocation/system not less than 500 microns)(e) All joints and changes in direction should be curved with cement mortar 1:3 mixed with SBR latex @200ml per bag of cement and cured well before laying the roof treatment.Note:1. fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers contain Tensile strength of 2 90Mpa, Elongation upto 350%, solid content 55.90 crack bridging ability upto 2.5mm 2. Treatment shall be done through authorise representative of manufacturer and atleast 10 years water proofing warranty by manufacturer. |
| 100 | M&L for machine cut Kota stone sataircase, step 18-20 mm thick and laid over and inc 15mm thick screed bed in CM (1:6), set and jointed with grey cement slurry mixed wit pigment to match the shade of the slab, with and including Cutting / Griding and Polishing on Kota stone with 2 Nos grove line and half moulding as per local trade practice, compléte all as specified and as directed. |
| 101 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and removing materials to store for taking credit and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. |
| 102 | M&L for point wiring for modular fittings complete with 1.5 Sqmm FRLSH insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLSH insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of modular cover plates with frames and 1.50 sq mm PVC insulated unsheathed stranded copper conductor (FRLSH) cable for common earth and connecting to earth dolly all as specified and directed by Enrg-in-charge. (Note- rates of chasing/cutting & making goods shall be included in the unit rate) :- |
| 103 | One light point/ceiling fan/exhaust fan/call bell controlled by one switch |
| 104 | One 6A socket point controlled by one switch on independent board |
| 105 | One 6A socket point controlled by one switch on same board |
| 106 | All as per srl item No 101 here-in-before but with 2.5 sq mm FRLSH copper wire with 2.5 Sqmm FRLSH copper earth wire for one 16 Amp socket point controlled by one 16 Amp switch on independent board. |
| 107 | M&L for submain wiring alongwith earth wire 2 runs x 6 sqmm + 1 run x 6 sqmm with FRLSH insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit ISI Marked conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc incl taking down old submain wiring alongwith conduit complete all as specified and as directed by Engineer-in-Charge. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length |
| 108 | All as per srl item No 103 here-in-before but 2 runs X 2.5 Sqmm + 1 run X 2.5 Sqmm. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length |
| 109 | Supply and fix of Modular switch 1 way 6A, 1 module 240V, 50Hz complete all as specified and as directed. |
| 110 | Supply and fix of Modular fan regulator step type in 5 steps, 240V, 50Hz complete all as specified and as directed. |
| 111 | Supply and fix of Modular Socket, 6A - 2/3 pin combined 2 module 240V, 50Hz complete all as specified and as directed. |
| 112 | Supply and fix of Modular switch 1 way 16A, 1 module 240V, 50Hz complete all as specified and as directed. |
| 113 | Supply and fix of Modular Socket 6A/16A - 2/3 pin combined 2 module 240V, 50Hz complete all as specified and as directed. |
| 114 | S&F of Lamp holder, angle type with metal ring, PVC/Polycarbonate body complete all as specified and as directed. |
| 115 | S&F of Ceiling rose, three terminals, bakelite body, 240 volts, complete all as specified and as directed. |
| 116 | S&F Modular Bell Push , flush type, 5 Amp, marked with valid CML complete all as specified and as directed |
| 117 | S&F electric bell of DINGDONG type, 240 volts, single pole, marked with valid CML and making all necessary connections, complete all as specified and as directed. |
| 118 | S & F of 7W White LED retrofit lamp suitable for B-22 holder base with polycarbonate diffuser and aluminium heat sink. |
| 119 | Supply and fix in replacement of Decorative wall light fixture made up of Polycarbonate with and including 7W retrofit LED lamp, full white / warm white of approved model complete all as specified and as directed by Engineer-in-Charge. |
| 120 | Supply and fix in replacement of exhaust fan with plastic body with louvers, 250 mm sweep, single phase, 230 volts, 50 Hz. complete all as specified and as directed. |
| 121 | Supply and fix in replacement of LED lights fitting 1 x 20 W 4 feet, 220 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 122 | Supply and fix in replacement of LED light fitting 1 x 10 W bulkhead luminaires including LED Driver holder connecting up with three core flexible copper conductor cable of suitable size. |
| 123 | Supply and fix in replacement of LED building security light fitting 35 watts with high efficiency long life LEDs with In-built electronic driver complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP 65degree of protection including GI pipe bracket made up of 25mm dia medium grade GI pipe of length 1.50m bent to required shape and fixing on walls with suitable MS clamps(02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washers and provision of 3 core twisted flexible copper cable 0.5 sqmm from ceiling rose to connector of fitting complete all as specified and as directed by Engineer-in-Charge. |
| 124 | Supply and fix of Electric Water Heater storage type, vertical, 25 Ltrs capacity, 5 Star rated, with heating element, PUF insulation, multifunction safety valve, adjustable knob for temperature setting and steel/PVC body with glass line/SS inner tank and outer body suitable for operating on 230V, 50 Hz, single phase AC supply including hot & cold water PVC connections and mounting on wall with suitable size & No. of anchor bolts complete all as specified and as directed. Note. Old and u/s geyser removed from site and deposited to AGE E/M Yard . Make- Havells/Crompton/Bajaj |
| 125 | S&F of ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value more than 6.00 BEE. Five star rated with brushless direct current motor (BLDC) all as specified and directed by Engineer-in-Charge. Note. Old and u/s ceiling fan removed from site and deposited to AGE E/M Yard . Make- Havells/Crompton/Bajaj |
| 126 | Supply and fix in replacement of modular MCB protected plug and socket board in sheet steel enclosure with 25A rated mini MCB and 25A rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board and making good with cement plaster, putty and paint to match with the existing surface complete all as specified and as directed by Engineer-in-Charge. |
| 127 | S&F of MCB distribution board, TPN, 4 way, 415 V, 3 phase, AC in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface complete all as specified and as directed. Note: MCBs shall be measured and paid separately. |
| 128 | Supply and fix in replacement of MCB distribution board, SPN, 8 way 230 Volt in sheet steel powder painted enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge. Note: MCBs shall be measured and paid separetely. |
| 129 | S&F of MCB 63A, 10 KA, TPN, 415 V, 50 Hz complete all as specified and as directed. |
| 130 | S& F MCB SPN 40-63 Amp, 10 KA, 'C' curve, 230 V, 50 Hz complete all as specified and as directed. |
| 131 | All as per srl item No 123 here-in-before but SP 6 to 32 Amp, 230 V complete all as specified and as directed. |
| 132 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and overall PVC sheathed, 16 sq mm 4 core in service connections as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc including taking down existing service cable of any description complete all as specified and as directed. |
| 133 | Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and as directed by Engineer-in-Charge. |
| 134 | Taking down old U/S earthing and M&L for earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to GI wire 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 15mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and as directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth wire up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail