| 1 | Removing the existing furniture and other office equipments, Dismentaling of reception counter, dismentling of plinth protection etc during the execution of work including placing them back at proper place as per departments requirement. |
| 2 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead Of area of 3 sqm. and below |
| 3 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead. 15.23.1 For thickness of tiles 10 mm to 25 mm |
| 4 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 min width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: |
| 5 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 above plinth level including curing in Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 6 | Extra for brick work in superstructure above plinth lvl upto floor five lvl |
| 7 | 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand) |
| 8 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 9 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 10 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc.complete. 50 mm |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form work for: 4.6.1 Foundations, footings, bases for columns |
| 12 | Supplying chemical emulsion in sealed containers including delivery as specified. Chlorophriphos/Lindane emulsifiable concentrate of 20% |
| 13 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti termite treatment. |
| 14 | Treatment of soil under existing floors using chemical emulsion (Chlorophriphos/Lindane E.C. 20% with 1% concentration) @ one litre per hole, 300mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement :2 coarse sand) to match the existing floor: |
| 15 | Treatment of points of contact of wood work with chemical emulsion Chlorophriphos /Lindane E.C. 20% with 1% concentration (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same |
| 16 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 17 | Providing and laying vitrified/Glazed/full body floor tiles 12 mm thick with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Make Simpolo as per architectural plan |
| 18 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.Size of tile 1000x1000 mm |
| 19 | Providing and fixing in position Aluminum composite panel sheets in different shades and design including fixing coated steel/GI sections and all other fittings hooks etc. complete job |
| 20 | Providing and fixing in position HPL (High pressure laminates) sheets in different shades and design including fixing coated steel/GI sections and all other fittings hooks etc. complete job |
| 21 | Finishing walls with textured paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/10sqm |
| 22 | Providing & fixing in place sheet type water fall system for the lounge including all lightings tiling/stone cladding / marble/ granite work and disposal etc complete job and as per architectural plan(12x8) ft including all materail, labour and carriges complete Complete |
| 23 | Engaging plumber for making connection and other miscellinious plumbing related works at site |
| 24 | Providing and laying water proofing treatment on terrace with flex shield TPO membrane (115 mil -2.92 mm) complete as per specifications and directions of consultant , Engineer in charge |
| 25 | Providing and filling of RBM in layers all complete job |
| 26 | Providing and fixing of reception counter made of 19 mm 710 grade plyboard with 12mm corean finished counter including cutting buffing polishing and moulding complete with accessories like hindges modular handles and slide channels completea as proposed by cunsultant and duly vetted by intending department and verified by engineer incharge including all material labour and carriages all complete |
| 27 | supplying and placing at site the furniture items proposed by cunsultant and duly vetted by intending department and verified by engineer incharge including all material labour and carriages all complete |
| 28 | SOFA SEATS |
| 29 | CENTRE TABLE |
| 30 | CHAIR |
| 31 | SIDE TABLE |
| 32 | Carriage of material( aggregates below 40 mm incl sand for an avg lead of 10 km by MT |
| 33 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A |
| 34 | Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required. |
| 35 | 2 X 2.5 SQ.MM + 1 X 2.5 SQ.MM Earth Wire |
| 36 | 2 X 4.0 SQ.MM + 1 X 4.0 SQ.MM Earth Wire |
| 37 | 4 X 10.0 SQ.MM + 2 X 6.0 SQ.MM Earth Wire |
| 38 | 4 X 16.0 SQ.MM + 2 X 6.0 SQ.MM Earth Wire |
| 39 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 40 | 1 x 1.5 sq. mm |
| 41 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 42 | 2 Pair |
| 43 | Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non- Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc. complete as required. |
| 44 | 1 run of cable |
| 45 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 46 | 25 mm |
| 47 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 48 | 5/6 amps switch |
| 49 | 3 pin 5/6 amp socket outlet |
| 50 | 15/16 amp switch |
| 51 | 6 pin 15/16 socket outlet |
| 52 | Telephone socket outlet |
| 53 | Computer Socket (RJ45) |
| 54 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 55 | Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required |
| 56 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 57 | 1 or 2 Module (75mmX75mm) |
| 58 | 3 Module (100mmX75mm) |
| 59 | 4 Module (125mmX75mm) |
| 60 | 6 Module (200mmX75mm) |
| 61 | 8 Module (125mmX125mm) |
| 62 | 12 Module (200mmX150mm) |
| 63 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 64 | Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required. |
| 65 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 66 | 8 way (4 + 24), Double door |
| 67 | Supplying and fixing following rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 68 | Single Pole 6 to 32 Amp |
| 69 | Single pole and neutral 63 Amp |
| 70 | Single pole and neutral 40 Amp |
| 71 | Supplying and fixing following rating, Four pole, 415 V, 10 Ka M.C.B in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 72 | 40 A TPN MCB 10 Ka \\"C\\" Curve & 40 A TPN MCB 10 Ka \\"C\\" Curve |
| 73 | 63 A TPN MCB 10 Ka \\"C\\" Curve & 40 A TPN MCB 10 Ka \\"C\\" Curve |
| 74 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 75 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 76 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 77 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 78 | Supply installation testing and commissioning of Ceiling Fan 3 Star Rated with Voltage Range 90 V to 300 V,Min. Air Delivery 212 CMM,Service Value 5.3 Cu.m/min/watt,Aluminium Blades ,including wiring the down rods of standard length(Upto 45 cm)with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required. |
| 79 | 1200 MM |
| 80 | LED Down lighter (SMD Type) (System lumen efficacy ≥120<135lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation ColorMatching) <3, Maximum power consumption should not more than the specified rating andFixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim . |
| 81 | 18 watt |
| 82 | Supply, installation, testing and commissioning drum led light 1 Phase |
| 83 | Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required. Watt, 25V rms operating at 240 Volt AC Supply complete as required. |
| 84 | Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required. |
| 85 | Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.speaker cable Two pair, 2-core, 1.5 sqmm |
| 86 | Supply, installation, testing and commissioning of cope Led Light |
| 87 | Supply, installation, testing and commissioning of Junction Boxes/DB-10 Pairs with Original Krone module and Back Mount Frame and have Lock -n- key, complete in all respect as per specification and desired by EIC |
| 88 | Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. |
| 89 | 6 U Rack |
| 90 | 9 U Rack |
| 91 | Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. |
| 92 | Copper Patch Cords of length 1m (3ft) |
| 93 | Copper Patch Cords of length 3m (10ft) |
| 94 | Supplying of LED TV (Smart TV) UHD 4K 55\\" |
| 95 | Supplying Installation Testing and Commissioning of 2 MP IP IR Dome Camera having following specifications, type of lens and features etc :- 1) Signal System: PAL/NTSC, Signal to Noise Ratio: >50 dB, Camera should display Camera title, Date & Time in live & recorded video 2)Image Sensor: 1/2.8\\" or better progressive Scan CMOS to get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 3) Compression (Minimum):-Video:- H.265 or better, H.264H, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 4) Wide Dynamic Range:- WDR (120db or more) 5) Digital Noise Reduction:- DNR (3D) On/Off 6) Video Streaming & Frame Rates :- Triple streaming , configurable (Main stream: 2MP (1920 ×1080)@25/30 fps,Sub streams minimum: 720P@25/30 fps). 7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection 8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, syslog, video encryption, IP/MAC filtering, HTTPS, trusted upgrade, trusted boot. 9) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. 10) Recording Management: Format SD, overwrite, storage management, video to NAS device 11) Alarm Trigger : Motion/tampering detection; audio detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast 13) System Capability: ONVIF, Camera shall support open source VMS 14) Ethernet: 1 RJ 45 10/100 Ethernet port 15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement. 16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source. 17) Power Requirement: 12VDC/24 VAC/PoE (802.3af)/ePoE 18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body 19) Operating Condition:- Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing) 20) IR life: 40000 hours or higher 21) Video Bit rate: 32 KBPS - 8 MBPS or better 22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS |
| 96 | 4MP @ 25/30fps@1440P (2560x1440) Dome Camera with 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens. |
| 97 | Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below : 1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses for number of channels of NVR to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP, IR camera or more and must be ONVIF with minimum support of 256Mbps incoming Bandwidth. 2) NVR should support H.265 or better, H.264, MJPEG, MPEG4 support 3) Must support 1 channel Input, 1 channel Output, RCA for Two-way Talk 4) Intelligent auto power on when power resumes after power outage. 5) Storage: It should support minimum 2 SATA Slots with 20TB capacity/ Slot. 6) Connectivity Interface : 1 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS232 7) Backup Interface : Its should have 2 Nosx USB port (1x USB3.0, 1xUSB2.0) 8) Video Output Ports: 1x HDMI and 1 VGA 9) Alarm Ports: It should have 4/1 Ch In/ Out ports to connect various type of external sensors and output devices like hooter/ Siren etc. 10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempring, network disconnection and panic 11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing. 12) Protocols: HTTP, HTTPS, TCP/IP, IPv4, UDP, NTP, DHCP, DNS, SMTP, UPnP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEM Cloud for remote monitoring without any public IP need. 13) Standards: CE, FCC, RoHS and BIS Certified 14) Power Supply : Should support 12VDC, 4Amp or AC100-240V, 50/60Hz Power supply. 15) Operating Condition : Ambient Temperature (-5°C to 50°C), humidity 90% (max) (non-condensing) 16) The VMS, NVR application shall support all the features & functionalities of the offered cameras. 17) VMS should consist of Base license and Channel Licenses. VMS should be provided with camera Licenses , with no dependency of VMS licenses by binding with the MAC address of the cameras to achieve the functionality. 18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage.19) The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet. 20) Must support Resolution: 7680x4320 (8K), 3840*2160, 1920×1080, 1280×1024,1280×720, 1024×768 21) Must support recording resolution upto 32MP 22) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode 23) When alarm recording is enabled and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function is supported on monitoring and playback page24) The Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient email address shall be configured to receive any combination of critical, warning, or informational messages or alarm notifications. When an alarm occurs, the email message includes the NVR name, time of alarm and a list of camera that is configured to record upon alarm 25) It should support Network Support: HTTP, TCP/IP, SMTP, DHCP, DNS, DDNS, FTP, NTP, UPnP, Multi IP Setting. Convert multiple recording files to one avi/MP4 file. 26) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection. 27) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan 28) Alarm Notification should be linked with Recording,snapshots, Camera external alarm output, buzzer, logs, presets and email. 29) Built-In Artificial Intelligence: NVR should have built-in AI :- - 2 Channel face detection and recognition, - Minimum 4 Channel perimeter protection, - Minimum 8 Channel Smart Motion Detection 30) Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity of Minimum 20,000 Faces or more with Face Detectionspeed of 12 face images/sec. 31) Face & Human Attributes Search: Search Pictures/Video by Gender, age group, glasses, expressions, face mask, beard, Top color, top type, hat, bag, age, gender and umbrella. 32) ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc vehicle attributes. 33) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan, cybersecurity exception 34) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email. 35) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection,Violence Detection. 36) Smart playback function: Should support smart search for the selected area in the video and smart playback to improve the playback efficiency37) VCA (Video Content Analytic): Should support multiple video contented analytics based on camera analytics |
| 98 | 08 Channel Network Video Recorder (NVR) having |
| 99 | Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. |
| 100 | 6TB (Terabytes) |
| 101 | Supplying and Laying of 20 Mtr HDMI Optical Fiber Cable AOC 2.0, 4K with Bandwidth 18Gbps |
| 102 | Supplying and Fixing of S.D Card 256 G.B in the Existing Camera |
| 103 | SITC of CAT 6 F/UTP 16 Port Modular fully loaded patch Panel TIA/EIA-568-C.2:2009 EN 50173- 1:2011 Class E, ISO/IEC11801:2010 (Ed 2.2) Class E, FCC Subpart F68.5 UL Listed. Make - MOLEX/ BELDEN /PANDUIT/ PRIMUS, Legrand |
| 104 | Supply, Installation, Testing and Commissioning of 16-Ports 10/100/1000Mbps PoE + 2-Ports SFP 100/1000Mbps Smart Managed Switch, 130Watts,Switch Should Support 8 x 10BASE-T/100BASE-TX/1000BASE-T POE Ports, 2 100/1000 Mbps SFP ports, auto- negotiatiation ports, 130 Watts Power Budget.Switch Should Support Min. 20Gbps Switching Capacity and Maximum 64 Byte Packet.Forwarding Rate is 14.88Mpps, MAC Address Table: 8K and 4.1 MBits Packet Buffer, 256 Static MAC Entries.Switch Should support Time based POE & CPU Protection.Power Saving (Green) EEE 802.3az Energy Efficient Ethernet (EEE). Switch Should Support 4 Queues per port, Traffic Prioritization 802.1p, Strict Priority, Bandwidth Control: Port-based (Ingress/Egress, min granularity 10/100/1000 is 16 Kbps),Switch Should Support Access Control List based on: 802.1p priority, VLAN, MAC address, Ether type, IP address, DSCP, Protocol type, TCP/UDP port number, IPv6 Traffic Class, Max. ACL Profiles / Rules: 50 / 768,Switch Should Support 802.1X Authentication, Max. 128 entries when using local database, IPv6 RADIUS server, MD5 authentication,Switch Should Support DoS attack prevention, Port Security: Max. 64 MAC Addresses per Port, Broadcast/Multicast/Unicast Storm Control, DHCP Server Screening, Support 2 IP Interface & IPv6 Neighbour Discovery (ND), Traffic segmentation,Switch Should Have FCC Class A,CE Class A,IC Class A, UL Certifications. (Make Dlink, CISCO) |
| 105 | Supply,Installation,Testing and Commissioning of Media Converter. |
| 106 | Supply & Erection of Termination Box complete as per specification and as desired by EIC. |
| 107 | Supplying and drawing following core Fiber Optic Cable having corrugated steel armoring. The Fiber should be SM Fiber Central -loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 0C to +50 0C and Storage Temperature shall be – 5 0C to +50 0C, Max Attenuation ± 0.36 (db / km) at Operational Wavelength 1310 nm and ± 0.22 db / km at Operational Wavelength 1550 nm. type of fiber should be 9/125 / G.652D & Refractive Index should be 1.4670/1.4675. The value for Mode-filed, Cladding Diameter 9.2 ± 0.4 μm and 125 ± 0.7 μm correspondingly. The Dispersion value < 3.5 < 18 ps/nm-km and PMD value < 0.2 ps/km and Cable Cutoff wavelength < 1260 nm i/c splicing & marking etc complete as required. |
| 108 | Single Mode 12 Core Optical fiber cable |
| 109 | Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color, Use for 24- 26 AWG stranded wires etc. complete asrequired. |
| 110 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Reducer (galvanisation not less than 50 microns) withperforation not more than 17.5%, in convenientsections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size Gi angle, GI bolts & nuts, fastner etc as required.225 mm width X 50 mm depth X 1.6 mm thickness |
| 111 | Supply installation testing and commissioning of Jessica Gold Crystal Chandelier700mm 1 Phase supply |
| 112 | Supply installation testing and commissioning of Jessica Gold Crystal Chandelier1200mm 1 Phase supply |
| 113 | Supply installation testing and commissioning of 2.2 KVA Sine Wave Inverter , Input 1 Phase 3 wire and output 1 phase 3 wire with 2 Nos of 12 V 200 aH Battery. |
| 114 | SITC of Hall Distribution Panel Indoor (IP:42) free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment'switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by fexible copper wires (upto 125 amp) and by solid bus bar (> 125). d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineerin charge. |
| 115 | INCOMER63 Amp, 25 KA, FP MCCB ICU = 100% ICS |
| 116 | Aluminium Bus Bar 100 Amp set of 4 strips 18\\" |
| 117 | Digital Metering devices, comprising of Voftmeter, Ammeter,Selector Switch, Indicating Lamp, CT Set etc. |
| 118 | OUTGOINGS63 A TPN MCB 10 Ka \\"C\\" Curve |
| 119 | 40 A TPN MCB 10 Ka \\"C\\" Curve |
| 120 | 25 A OPN MCB 10 Ka \\"C Curve |
| 121 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 122 | Supplying and Laying of one number PVC insulated and PVCsheathed/XLPE power cable of 1.1 KV grade of following size direct in groundin Existing DWC Pipe including excavation, sand 3.5 CX 25Sq.mm A2XFY (Wall Panel to Main Panel) |
| 123 | Supply and Making end Termination with Brass CompressionGland and Aluminium Lugs for the Following Sizes of PVC insulated and PVC Sheathed/XLPE Aluminium Conductor Cable of 1.1 KV Grade as Required (Comet)3% X 25 sq. mm (32mm) |
| 124 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 m m dia 6 mm thick G.I. base plate including holes etc. complete as required. Please Enable Macros to View BoQ information |