| 1 | Supply and installation of vertical model double door TPN/SPN Distribution boards with minimun IP 43 of following sizesNote: RCBO& MCBs shall be C rated and indicative type |
| 2 | Installation only of 8 /12 way vertical model TPN MCB DBNote: DB along with required MCBs would be supplied by the department free of cost |
| 3 | 12 Way Horizontal SPN MCB DB with following components.a. 25 A DP 30mA RCBO incomer - 1 Nob. 10A SP MCB - 6 Nosc. 16A SP MCB - 2 No |
| 4 | Supply |
| 5 | Installation |
| 6 | 12 Way Horizontal SPN MCB DB with following components.a. 32 A DP 100mA RCBO incomer - 1 Nob. 10A SP MCB - 6 Nosc. 16A SP MCB - 2 No |
| 7 | Supply |
| 8 | Installation |
| 9 | Supply and installation of MCBs/RCBOs/SFUs of following ratings |
| 10 | 4P 400A SFU with HRC fuses and SS Enclosure Box and adapter box at bottom and top sides with required gland plates |
| 11 | 4P 125A MCB - C curve |
| 12 | 4P 40A MCB - C curve |
| 13 | 4P 32A MCB - C curve |
| 14 | 3P 32A MCB - C curve |
| 15 | 3P 20A MCB - C curve |
| 16 | 4P 63A 100mA Type AC RCBO |
| 17 | 4P 63A 30mA Type A RCBO |
| 18 | 2P 32A 100mA Type AC RCBO |
| 19 | 2P 25A 30mA Type A RCBO |
| 20 | Supply and installation of following light fittings with all accessories like supporting hardware, downrods, junction boxes, required frames etc as required to complete the installation in all respects |
| 21 | Circular recess mounted LED light fitting with with lumen output>1200 lumens, Luminaire efficacy of >110 lm/W, CCT:5700K, CRI>=80, IP20, power factor>0.9 , surge protection of minimum 2.5 KV, Protection class IEC safety class-1 |
| 22 | Supply |
| 23 | Installation |
| 24 | Circular recess mounted LED light fitting with with lumen output>600 lumens, Luminaire efficacy of >110 lm/W, CCT:3000K, CRI>=80, IP20, power factor>0.9 , surge protection of minimum 2.5 KV, Protection class IEC safety class-1 |
| 25 | Supply |
| 26 | Installation |
| 27 | LED high efficient 2ft X 2ft, generation-V or better, surface-cum-recess mounted light fitting with CRCA housing, with output >=3600 Lumens, Luminaire efficacy of around >120 lm/W, IP20, surge protection of minimum 4KV, power factor>0.95, THD<10%, CRI>80, CCT-5700K , voltage range 140-270V AC, Electrical insulation class-1, EMI/EMC compliance. |
| 28 | Supply |
| 29 | Installation |
| 30 | LED high efficient 4ft batten type light fitting with CRCA housing, with output >2000 Lumens, Luminaire efficacy of around >= 110 lm/W, IP20, surge protection of minimum 4KV, power factor>0.9, CRI>80, CCT-5700K, voltage range 140-270V AC, Protection class IEC-safety class-1, EMI/EMC compliance. |
| 31 | Supply |
| 32 | Installation |
| 33 | LED 2ft Suspended/ Surface Mounted Linear sleek profile luminarie with aluminium extruded housing, with output >=1200 Lumens, Luminaire efficacy of around >=120 lm/W, CRI >=80, IP20 ,surge protection of minimum 4KV, power factor>0.9, CRI>80, CCT-5700K, voltage range 140-270V AC,Protection class IEC-Safety class-II, EMI/EMC compliance. |
| 34 | Supply |
| 35 | Installation |
| 36 | LED 4ft Suspended/ Surface Mounted Linear sleek profile luminarie with aluminium extruded housing, with output >=2200 Lumens, Luminaire efficacy of around >=120 lm/W, CRI >=80, IP20 ,surge protection of minimum 4KV, power factor>0.9, CRI>80, CCT-5700K, voltage range 140-270V AC,Protection class IEC-Safety class-II, EMI/EMC compliance. |
| 37 | Supply |
| 38 | Installation |
| 39 | LED Industrial flood light fittings with output >8000 Lumens, Luminaire efficacy of >140 lm/W, IP65, inbuilt surge protection of minimum 4KV, CRI>70, CCT-5700K, voltage range 180-270V AC, Lifetime of 50,000 burning hours, Insulation class-1 |
| 40 | Supply |
| 41 | Installation |
| 42 | Supply of remote controller/Configuration tool for dual tech (infrared and ultrasonic) occupancy sensors for automatic lighting control similar to Legrand 088230 |
| 43 | Supply and fixing of 230V, 600mm sweep BLDC Energy efficient 5 star rating fans with required SS downrods of 2M length and SS heavy duty D-hook hanger with all required accessories. The fan should be compatible with any standard regulator.Warranty: 2 Years |
| 44 | Supply |
| 45 | Installation |
| 46 | Supply and installation of fan hanging plate fabrication with powder coated ms plate of dimensions 6mm * 100mm * 100mm including required anchor bolts and SS heavy duty D hook. |
| 47 | Supply and installation of 2M long fan down rods for lowering the fans. |
| 48 | Fixing only of 230V, 600-1200mm sweep ceiling fan with all required accessories.Note: Fans would be supplied by the department free of cost. |
| 49 | Pedestal Fans with 400mm sweep with push button type regulator and 3 speed settings and with adjustable height between 900mm to 1050mm |
| 50 | Supply |
| 51 | Installation |
| 52 | Fixing only of 300mm sweep Single phase heavy duty industrial exhaust Fans with all required supports and accessories. |
| 53 | Supply and installation of 20 A 2pole & Earth Metal clad power socket with 20 A SP MCB control including plug top |
| 54 | Supply |
| 55 | Installation |
| 56 | Supply and installation of MCB enclosure boxes with following details |
| 57 | Powder coated sheet steel 4 way enclosure box with 4M 63A 4P MCB |
| 58 | Supply |
| 59 | Installation |
| 60 | Powder coated sheet steel 4 way enclosure box with 4M 32A 4P MCB |
| 61 | Supply |
| 62 | Installation |
| 63 | Powder coated sheet steel 2 way enclosure box with 2M 10A DP MCB |
| 64 | Supply |
| 65 | Installation |
| 66 | Supply and installation of modular switch boards along with required face plate, surface mounted PVC back box, frame of following sizes with latest model rugged modular type sparkproof switches and shuttered universal sockets. Colour of the switches and sockets/frame shall be Grey/white colour. |
| 67 | 8 modular switchboard with 5 Nos 6A Switches and 1 No of 6A socket and 1 No of 1M Fan Regulator |
| 68 | Supply |
| 69 | Installation |
| 70 | 12 modular switchboard with 4 No 6A socket and 4 Nos of 6A switches |
| 71 | Supply |
| 72 | Installation |
| 73 | 6 modular switch board with 2 No of 6/16 A universal Sockets and 2 nos of 16A switches |
| 74 | Supply |
| 75 | Installation |
| 76 | 3 modular switch board with 3 No of 6A switches |
| 77 | Supply |
| 78 | Installation |
| 79 | 3 modular switch board with 1 No of 6/16A universal socket and 1 No of 16A switches |
| 80 | Supply |
| 81 | Installation |
| 82 | Supply and installation of modular switch boards along with required face plate, concealed GI back box, frame of following sizes with latest model rugged modular type sparkproof switches and shuttered universal sockets. Colour of the switches and sockets/frame shall be Grey/white colour. |
| 83 | 12 modular switchboard with 4 No of 6/16 A universal Sockets and 4 nos of 16A switches |
| 84 | Supply |
| 85 | Installation |
| 86 | 8 modular switch board with 2 No of 6/16 A universal Sockets and 2 nos of 16A switches and 2 nos of Fan Regulators |
| 87 | Supply |
| 88 | Installation |
| 89 | 6 modular switchboard with 2 No of 6/16 A universal Sockets and 2 nos of 16A switches |
| 90 | Supply |
| 91 | Installation |
| 92 | 3 modular switchboard with 1 No of 6/16 A universal Sockets and 1 nos of 16A switches |
| 93 | Supply |
| 94 | Installation |
| 95 | 2 modular switchboard with 1 No of DP 25A MCB |
| 96 | Supply |
| 97 | Installation |
| 98 | Supply and pulling of following sizes of flexible HFFR copper wires to be drawn in already concealed PVC conduit/channels/external conduit/ DLP trunking with ferruling on both ends excluding cost of pipes, channels and switch boards. |
| 99 | 1.5 Sq.mm Copper wire |
| 100 | Supply |
| 101 | Installation |
| 102 | 2.5 Sq.mm Copper wire |
| 103 | Supply |
| 104 | Installation |
| 105 | 4 Sq.mm Copper wire |
| 106 | Supply |
| 107 | Installation |
| 108 | Supply and laying of following sizes of 1.1 KV grade XLPE insulated, PVC extruded inner sheathed, armoured, FRLS PVC ST2 outersheathed cable on cable trays/trenches/ground with all accessories |
| 109 | 3.5c 35 Sq.mm Al cable |
| 110 | Supply |
| 111 | Installation |
| 112 | 4c 6 Sq.mm Cu cable |
| 113 | Supply |
| 114 | Installation |
| 115 | Installation only of 3c 2.5 / 1.5 Sq.mm Cu cable Note: Cable will be supplied by department free of cost |
| 116 | Providing end terminations for following sizes of 1.1 KV grade XLPE insulated and PVC sheathed armoured cables with required hard ware like heavy duty double compressor glands, heavy duty long neck copper lugs etc complete |
| 117 | 3.5c 35 Sq.mm Al cable |
| 118 | Supply |
| 119 | Installation |
| 120 | 4c 6 Sq.mm Al cable |
| 121 | Supply |
| 122 | Installation |
| 123 | 4c 2.5 Sq.mm Cu cable |
| 124 | Supply |
| 125 | Installation |
| 126 | 3c 1.5 Sq.mm Cu cable |
| 127 | Supply |
| 128 | Installation |
| 129 | Supply and laying of following sizes of 1.1 KV grade PVC insulated, PVC extruded inner sheathed, , FRLS PVC ST2 Flexible cable outersheathed cable on cable trays/trenches/ground with all accessories |
| 130 | 3c 1.5 Sq.mm Cu cable |
| 131 | Supply |
| 132 | Installation |
| 133 | 1c 6 Sq.mm Cu cable |
| 134 | Supply |
| 135 | Installation |
| 136 | Supply and laying of 1.1 KV grade 12 core 2.5Sq.mm Copper conductor, XLPE insulated, PVC extruded inner sheathed,armoured, FRLS PVC outersheathed cable on cable trays/trenches with all accessories |
| 137 | Supply |
| 138 | Installation |
| 139 | Supply and installation with 8mm threading rods and anchor fastners of following sizes of 2mm thickness GI perforated cable trays along with tray cover |
| 140 | 200 mm width, 50mm height |
| 141 | Supply |
| 142 | Installation |
| 143 | 100 mm width, 50mm height |
| 144 | Supply |
| 145 | Installation |
| 146 | Supply and installation of 25 mm dia 1.8 mm thick PVC conduits and required junction boxes confirming to IS with accessories like bends, deep junction boxes, couplers etc (at least one for every 3m of length or as per site requirement whichever is higher) in wall , roof slabs, false ceiling etc, including cutting the wall/chasing and making good the same to the original finish complete |
| 147 | Supply |
| 148 | Installation |
| 149 | Supply and installation of accessories suitable for 25 mm dia PVC conduit |
| 150 | Coupling Bends |
| 151 | Couplers |
| 152 | Junction Box |
| 153 | Deep Junction Box |
| 154 | Fan Box |
| 155 | Supply and installation of 25 mm dia corrugated flexible conduit pipes |
| 156 | Supply |
| 157 | Installation |
| 158 | Supply and installation of 50 mm dia galvanized steel flexible conduit pipes with PVC coating |
| 159 | Supply |
| 160 | Installation |
| 161 | Supply and installation of 25 mm dia galvanized steel flexible conduit pipes with PVC coating. |
| 162 | Supply |
| 163 | Installation |
| 164 | Supply and installation of 32 x 20 mm DLP plastic trunking system with required clamps for fixing, cover, end caps etc complete including required angles and junctions (for every 2m of length) etc complete |
| 165 | Supply |
| 166 | Installation |
| 167 | Supply and installation of following accesories for already installed 32 x 20 mm DLP plastic trunking system |
| 168 | Variable internal angle |
| 169 | Variable external angle |
| 170 | T joint |
| 171 | End cap |
| 172 | Flat angle |
| 173 | Flat junction / coupling |
| 174 | Supply and installation of 105 x 50mm with separation partition DLP plastic trunking system with required clamps for fixing, cover, end caps etc complete including required angles and junctions (for every 2m of length) etc complete |
| 175 | Supply |
| 176 | Installation |
| 177 | Supply and installation of following accesories for already installed 105 x 50 mm DLP plastic trunking system |
| 178 | Variable internal angle |
| 179 | Variable external angle |
| 180 | T joint |
| 181 | End cap |
| 182 | Flat angle |
| 183 | Flat junction / coupling |
| 184 | Installation only of 415V TPN, 100A, 10KA Aluminum conductor air insulated busbar trunking system with required hardware, structural steel supports on the wall. |
| 185 | Supply and fixing of 25 x 6 mm hot dip galvanised GI strip for earthing at a height on cable trays/walls/ground |
| 186 | Supply and fixing of 8 SWG Hot Dipped GI wire |
| 187 | Suply and installation of structural steel like channels, angles etc for fabriaction and erection of, cable trays supports, light fitting supports etc and painting of the same with red oxide and 2 coats of grey enamel paint. Rate should also include the required bolts and nuts for fixing of supports |
| 188 | Supply |
| 189 | Installation |
| 190 | Supply and fixing of 100 mm X 25 mm anodised Aluminium cable tags engraved on black back ground with name of the load along with required hardware for fixing the lables on to the cables. |
| 191 | Excavation in ground for laying the cables, back filling with sand, bricks on all sides after laying the cables, consolidation removal of excess earth etc complete excluding cost of bricks/tiles/pipes. |
| 192 | Cutting of roads for about 1 meter width and 1.2 m depth including removing the soling for laying hume pipes and back filling, resoling and making good the road to the original finish |
| 193 | Supply and installation of 150mm NP2 class hume pipes with required couplers for road crossing of cables |
| 194 | Supply |
| 195 | Installation |
| 196 | Supply and installation of well burnt brick of size 230 x 115 x 75 mm size as per IS |
| 197 | Supply and installation of RCC tiles of size 500 x 250 x 50 mm made of 1:2:4 mix concrete and 8 mm steel rods 3 on each side |
| 198 | Supply |
| 199 | Installation |
| 200 | Supply and installation of 2mm thick powder coated 3 way MS junction boxes along with 6A 4 way connectors |
| 201 | Dismantling brick work or stone work made out of lime or cement mortar including stacking of materials as directed by Engineer-in-charge |
| 202 | Romoval of existing MCB Distribution boards of approx dimension 600 X 300mm mounted on the wall/concelaed in the walls and making good of the surface. The removed material should be shifted to an identified location about 500m away. |
| 203 | Removal of cables of about 95 Sq.mm to 2.5 sq.mm sizes and making good of the surface. The removed material should be cut to 1m lengths and shifted to an identified location about 500m away. |
| 204 | Removal of MS/PVC lighting Switchboards/ sockets and making good of the surface. The removed material should be shifted to an identified location about 500m away |
| 205 | Removal of light fitting along with their down rods and other accessories and making good of the surface. The removed material should be shifted to an identified location about 500m away. |
| 206 | Removal of ceiling fans / exhaust fans along with their down rods and other accessories and making good of the surface. The removed material should be shifted to an identified location about 500m away. |
| 207 | Removal of flexible wires of sizes 1.5 sqmm to 4 sqmm in concealed conuits/surface conduits/trunking and making good the surface. The removed material should be shifted to an identified location about 500m away as per directions of Engineer-in-charge |
| 208 | Removal of telephone and network cables in concealed conuits/surface conduits/trunking and making good the surface. The removed material should be shifted to an identified location about 500m away as per directions of Engineer-in-charge |
| 209 | Modification and Retrofitting works for existing L&T Type Tested 415V PDB with 100A SDFU incomer and 4 Nos of 63A SDFU outgoings. The PDB shall be modified as follows:a. 250A 4P 36kA microprocessor based MCCB with adjustable over current, short circuit and earth fault protections.The MCCB shall have required spreader links and Rotary operating Mechanism for door interlock. -1No as incomer (in place of 100A SDFU incomer)b. 125A TPN 36kA microprocessor based MCCB with adjustable over current, short circuit and earth fault protections.The MCCB shall have required spreader links and Rotary operating Mechanism for door interlock - 2 Nos outgoings (in place of 2 Nos 63A SDFU outgoings)c. 2 Nos 63A SDFU outgoings remain the samed. Replacement of existing CTs with 250/5A CTs along with its corresponding wiringe. 415V Panel mounted earth leakage relay with current range - 30mA to 30A to be fixed with required CBCT, wiring, shunt coil for tripping the incomer in case of earth leakage.f. modification of bus bar tappings (using electrical grade Aluminium busbars / Copper wires) to suit the current rating of switchesAcceptance tests ar per IS shall be carried out before handover.Note: Removed components shall be handed over to the department in good condition. Vendor deployed for the job shall be CPRI registered. Refer Technical Specification for more detail |
| 210 | Modification and Retrofitting works for existing 415V PDB. The PDB shall be modified as follows:a. 400A TPN SDFU with fuse links - 1 Nos outgoing (in place of 250A SDFU outgoing)b. modification of bus bar tappings (using electrical grade Aluminium busbars / Copper wires) to suit the current rating of switchesAcceptance tests ar per IS shall be carried out before handover.Note: Removed components shall be handed over to the department in good condition. Vendor deployed for the job shall be CPRI registered. Refer Technical Specification for more detail |
| 211 | Installation only of various Power Distribution Boards of approximate Dimension 1100mm (L) x 2200mm (H) x 400mm (W) including Shifting of the panels using Forklift to apprximately 500M away as per directions of EIC, Erection of the PDBs on MS frames, Grouting of Panels and Earthing complete Please Enable Macros to View BoQ information |