| 1 | M&L for Rendering 15 mm thick on of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:4), including taking down cement plaster complete all as specified and directed. |
| 2 | M&L for Rendering 10 mm thick on fair faces of concrete surfaces, finished even and smooth on ceiling in cement mortar (1:3), including taking down cement plaster complete all as specified. |
| 3 | M&L for Rendering 15 mm thick on of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:6), including taking down cement plaster complete all as specified. |
| 4 | M&L for preparation of new plastered wall surfaces complete all as specified and applying the following: -(a) Applying wall care putty, in two coats on wall surfaces & smoothening the surfaces with sand papers/ mechanized sanding etc., (preparatory to paint as directed), complete all as specified. (b) Two coats of acrylic distemper/distemper oil emulsion (OBD) over and including a coat of acrylic emulsion primer, complete all as specified. |
| 5 | M&L for preparation of new plastered wall surfaces of any description complete all as specified and applying the following: -(a) Applying wall care putty, in two coats on wall surfaces & smoothening the surfaces with sand papers/ mechanized sanding etc., (preparatory to paint as directed), complete all as specified. (b) Two coats of exterior acrylic emulsion over and including a coat of exterior primer, complete all as specified. |
| 6 | M & L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash on ceiling, complete all as specified and directed. |
| 7 | M&L for preparation of old plaster surface of wall and applying one coat of interior acrylic distemper complete all as specified and directed. |
| 8 | M&L for complete removal of existing treatment of any description, including preparation of wall surfaces of any description, complete all as specified and applying the following: -(a) Applying 1 -2 mm thick wall care putty, in two coats on wall surfaces & smoothening the surfaces with sand papers/ mechanized sanding etc., (preparatory to paint as directed), complete all as specified. (b) Two coats of acrylic distemper/distemper oil emulsion (OBD) over and including a coat of acrylic emulsion primer, complete all as specified. |
| 9 | M&L for one coat of white wash on old ceiling surfaces, including preparation of surfaces, complete all as specified. |
| 10 | M&L for complete removal of existing treatment of any description, including preparation of wall surfaces of any description, complete all as specified and applying the following: -(a) Applying wall care putty, in two coats on wall surfaces & smoothening the surfaces with sand papers/ mechanized sanding etc., (preparatory to paint as directed), complete all as specified. (b) Two coats of exterior acrylic emulsion over and including a coat of water based exterior primer, complete all as specified. |
| 11 | M&L for one coat of white wash on old wall surfaces, including preparation of surfaces, complete all as specified. |
| 12 | M&L for preparation of old painted surfaces of wood & wood based surface of any description not otherwise described over 10 cm width & girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge. |
| 13 | M&L for Preparation of new wood & wood based surface and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed . |
| 14 | M&L for preparation of old painted surfaces of steel & steel based surface of any description not otherwise described over 10 cm width & girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge. |
| 15 | M&L for preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamelled paint over one coat of red oxide primer complete all as specified and directed by Engineer in charge. |
| 16 | S & F in repair uPVC pipes,160 mm external dia pipe, type-A, ISI marked (IS:13592) single socketed in any length with or without rubber ring joints, fixed along walls with clamps as RWP complete. |
| 17 | S & F in repair uPVC pipes,110 mm external dia pipe, type-A, ISI marked (IS:13592) single socketed in any length with or without rubber ring joints, fixed along walls with clamps as RWP complete. |
| 18 | S&F in repair uPVC bend/Shoe, 160 mm external dia type-A, ISI marked any radius, complete all as specified and directed. |
| 19 | S&F in repair uPVC bend/Shoe, 110 mm external dia type-A, ISI marked any radius, complete all as specified and directed. |
| 20 | M&L for Uprooting tree/plants upto 30 cm girth from wall or any part of building upto double storey buildings completely to the entire satisfaction of Engineer-in-Charge, making good the disturbed portion and filling holes in cement mortar (1:3) or PCC (1:2:4) type B-1 using 20mm graded stone aggregate to match with existing surfaces and removal of rubbish outside MOD land complete all and specified and directed. |
| 21 | M&L for repairing of RCC projection chhajjas, roof, facia etc by necessary preparation. Scraping cutting, chiselling derusting and cleaning exposed reinforcement, surfaces of damaged, loose RCC with cement concrete (1:1.5:3) using 20mm graded stone aggregate and reinforcement with welded mesh of weight 2 Kg per Sqm but n.exc 3 Kg per Sqm (if reqd) with or without facia and finished with cement and sand mortar (1:3) using coarse sand and work in patches area n.exc 5 Sqm and thickness of RCC member n.exc 70mm incl necessary formwork and applying two coats of finishes to match with the existing surfaces at any height complete all as specified and as directed by Engr-in-Charge. (The rate quoted by the contractor shall included for scaffolding and necessary formwork upto triple storey bldg). |
| 22 | S&F Steel windows made of MS sheet 1.25 mm thick box type (primer coated) ERW hollow ‘P’ section of size 60 mm x 25 mm single rebate comprises of skeleton shutter ERW sec 50 x 20 mm & 1 mm thick & openable leaf consisting two Nos sash bars of ‘T’ section 20 x 3 mm complete welded to frame including cutting holes & making good dismantled portion in PCC 1:2: 4 type B1 four Nos for each window including following fitting welded to shutter ;- (a) Hold fast 150 mm long 12 mm x 3 mm made to shape -04 Nos(b) Handle of ‘Z’ section 20 x 25 mm , 100 mm long 01 Nos each leaf.(c) MS tower bolt 150 mm long 02 Nos each leaf.(d) ‘Z’ section 20 x 25 mm , 100 mm stopper-01 Nos each leaf.(e) Cleat 55 mm long of hollow square 15 x 20 x 63 mm welded to hinges-01 Nos per leaf.(f) MS box type hinges of size 75 x 12 mm -02 Nos per leaf.(g) Fabrication & fixing complete. |
| 23 | All as per item above here-in-before but without sash bars complete all as specified and directed. |
| 24 | S & F Steel windows or ventilators, fixed type, with glazing bars complete all as specified and directed |
| 25 | Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors frame structure; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 26 | S & F for Stainless steel wire cloth,0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, etc complete all as specified and directed. |
| 27 | Supply and Fix 4 mm thick, Sheet glass, ordinary quality, in squares n exc 0.5 sq. m each pane ,etc complete all as specified and directed. |
| 28 | Supply and Fix for 4 mm thick, figured glass, pin head type in squares n exc 0.5 sq.m each pane, etc complete all as specified and directed. |
| 29 | Supply and fix 4 mm thick, Sheet glass, ordinary quality, in squares n exc 0.5 sq. m each pane, etc including hacking out old broken glass completed all as specified and directed. |
| 30 | S & F for flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, thickness 30 mm etc complete all as specified and directed. |
| 31 | S & F for 2nd class HW rail and style, thickness of shutters,35 mm, Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated etc complete all as specified and directed. |
| 32 | S & F 35 mm 2nd class hard wood factory made, Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a);,etc complete all as specified and directed. |
| 33 | S & F Factory made solid PVC Door frame of size 50mm x 47mm made out of 5mm thick wood grain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening, complete all as specified and directed |
| 34 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and a gap insert for top rail and bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded /sealed to the stiles and rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at site all as specified in SSR part-II 2004 Section-8, clause 8B.1 to 8B.2.1 and shown on drawing in page No 146 of SSR part-II 2004 complete all as specified and directed |
| 35 | S&F factory Made Solid PVC Moulded Door Shutter, as in cupboard, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing, etc complete all as specified and directed. |
| 36 | S & F for 250 mm long , Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, etc complete all as specified and directed. |
| 37 | S & F for Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21, size of hinges in 100 mm, etc complete all as specified and directed. |
| 38 | S & F 150 mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed by Engineer-In-Charge. |
| 39 | S & F 125 mm size, aluminium anodized handles, cast type complete all as specified and directed by Engineer-In-Charge. |
| 40 | S & F 300 mm long mild steel ordinary rat tail rod pattern door spring including roller and roller plate fixed in repairs complete all as specified and directed by engineer in-charge. |
| 41 | S & F for Hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws, Size of hasp and staple in 100 mm, etc complete all as specified and directed. |
| 42 | S & F floor door stopper of aluminium alloy body double leg 75-80 mm long with rubber stopper at bottom complete all as specified and directed. |
| 43 | S&F pressed steel frames made out mild steel sheet 1.25 mm thick, with size of frame 105 mm x 60 mm for doors with one or more rebates including necessary fixing lugs,100mm hinges, lock strike plates etc complete all as specified and as directed . |
| 44 | S & F Pressed steel frames made out mild steel sheet 1.25 mm thick, with size of frame 125 mm x 60 mm for doors with one or more rebates including necessary fixing lugs,100mm hinges, lock strike plates etc complete all as specified and as directed. |
| 45 | M & L for providing PCC 1:3 :6 type C-0 using 12.5 mm graded crush stone aggregate for filling back of chowkhats complete all as specified and as directed . |
| 46 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.50 Sqm each and removing to or from store complete all as specified and as directed by the Engineer-in-Charge |
| 47 | Taking down, Chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each but with shutters (without taking off shutters from the frame),etc and removing to or from store complete all as specified and as directed by the Engineer-in-Charge |
| 48 | Taking down shutters of any description exceeding 1.00 sqm but not exceeding 2.00 sqm each and removing from site complete all as specified and as directed by the Engineer-in-Charge |
| 49 | Cutting grooves in brick wall 75 mm wide and 65 mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed. |
| 50 | S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick bent quarterly on front side of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified etc completed all as specified and directed. |
| 51 | S & F rolled mild steel Fe 410-W (Gde-E-250 quality A) in joist, channel, angle, or tee sections, fixed independently, without connecting plates etc including all necessary drilling, bolting or riveting etc complete all as specified and directed. |
| 52 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 53 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for (above or below ground level) complete all as specified and directed. |
| 54 | M & L for 100 mm thick, Cement concrete type D-2, 1:4:8 (40mm graded aggregate) as in floor, etc completed all as specified and directed. |
| 55 | M & L for Chequered cement concrete tiles 25mm thick of any size and shape ,set, jointed and pointed in neat cement slurry in floors, with grey cement and no pigment including 20 mm thick screed bed in CM (1:6) , etc completed all as specified and directed. |
| 56 | M&L for cement concrete (1:2:4) type B-1 using 12.5mm graded stone aggregate as in coping including necessary formwork complete all as specified and directed. |
| 57 | Notes: Amount of credit for retrieved materials is mentioned in tender documents in pdf form which will be deducted while acceptance of tender offline. Please Enable Macros to View BoQ information |