| 1 | Dismantling of Asbestos cement or corrugated sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed. |
| 2 | S&F pre-painted Camouflage pattern trapezoidal profiled Galvalume/Zincalume sheet with min 0.50mm TCT confirming to IS-513 (AZ-150 GSM, AL Zn alloy metalic coating, 550 MPA yield stress as per AS-1397), colour /exterior coat of silicon modified polyster/ BHP X RW paint system 20 micron top coat applied over 5 micron primer and a 5 micron polyster back coat applied over 5 micron primer, as in roof covering/ cladding to wall, fixed with and including Galvanised self drilling self-tapping fastener (12-14 x 55 with EPDM seals), complete all as specified and directed. |
| 3 | S&F pre-painted Camouflage pattern plain sheet profiled Galvalume/Zincalume sheet with min 0.50mm TCT confirming to IS-513 (AZ-150 GSM, AL Zn alloy metalic coating, 550 MPA yield stress as per AS-1397), colour /exterior coat of silicon modified polyster/ BHP X RW paint system 20 micron top coat applied over 5 micron primer and a 5 micron polyster back coat applied over 5 micron primer,as in roof covering/ cladding to wall fixed with and including Galvanised self drilling self-tapping fastener (12-14 x 55 with EPDM seals), complete all as specified and directed. |
| 4 | Making good under cills over arches, lintel and bresummers,including all pinning when nessesary with using cement mortar (1:6) complete all as specified |
| 5 | Dismantling wrought iron or mild steel work of any description not otherwise provided for. complete all as specified and as directed. |
| 6 | S&F mild steel [Fe 410-W (Gde E-250) quality - A] as in roof trusses (framed), trussed, purlins, Gusset plate and base plates, where connected to common rafters and running rails, distance pieces, cleats, guides for sliding doors; fixed with angle cleats or other connecting plates, framing for cladding, staging for water tanks, nuts, bolts, washers etc,includng welding or riveting etc, complete all as specified and as directed. |
| 7 | Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and as directed. |
| 8 | S & F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fasteningand fixing complete confirming to Fe-290(Gde E-165) complete all as specified and as directed. |
| 9 | S&F mild steel rolled sections [Fe 410-W (Gde E-250) quality - B] as in main and cross beams , hip and jack rafters, purlins, Gusset plate and base plates, where connected to common rafters and running rails, distance pieces, cleats, guides for sliding doors; fixed with angle cleats or other connecting plates, framing for cladding, staging for water tanks, nuts, bolts, washers etc,includng welding or riveting etc, complete all as specified and as directed. |
| 10 | Supply & Fixing only 1.00mm Mild steel plain black steel sheets in available sizes for steel gates and similar work cut to size holes punched , including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up mitred angles etc as requried complete all as specified and as directed. |
| 11 | Demolition of cement concrete (un-reinforced ) in ground floors and pavings n exc 15 cm thickness (below or above ground level) including disposing off the retrieved debris outside the premises, complete all as specified and as directed. |
| 12 | M&L for 100 mm thick (average thickness), PCC (1:2:4) type B1 (using 20mm graded stone aggregates) as in floor/Subbase finishing cement concrete surface even & smooth without using extra cement, complete all as specified and directed. |
| 13 | M & L for forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade'A'. For 100mm thick concrete slab complete all as specified and directed. |
| 14 | M & L for forming Construction joint 30mm deep x10mm wide filled with sealing compound of Grade'A'. complete all as specified and directed. |
| 15 | M & L for forming Construction (dummy) joint 65mm deep x10mm wide filled with sealing compound of Grade'A'. complete all as specified and directed. |
| 16 | M&L for providing 75mm thick PCC (1:3:6) type C2 (using 20mm graded crushed stone aggregate), as in plinth protection, surface finished even & smooth without using extra cement including provision of 10 mm joints (at an interval of 3 metre and turnings) duly filled with fine sand and bitumen in the ratio of (3:1), complete all as specified and directed. |
| 17 | Supply only polyester triangular fibres as secondary reinforcment in all types complete all as specified and as directed |
| 18 | S&F anodised aluminium snap grid of size 605x605mm frame work for false ceiling hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out GI flat iron 40x3mm size 60mm long and fixed expansion hold fasteners 12.5mm dia and 40mm long,complete all as specified and as directed. |
| 19 | S & F 6mm thick Non-asbestos fibre cement decorative/designer building boards to steel frame work with screws in ceiling (flat and/or slopping) and including jointless finish with & also including joining compound and tape as per manufacturer instructions, with apply two coats oil bound distemper a coat of primer on ceiling complete, including dismantling of wall and ceiling boards complete all as specified and as directed.Notes :- (i) The board shall be confirming to IS-14862 and shall be manufactured from the homogeneious mixture of cement, quartz and cellulose and shall be curred with high pressure steam using auto claving process.(ii) Aluminium frame work shall be measured and paid for separately. |
| 20 | Taking down chowkats or frames with Wooden/PVC/Flush shutters (without taking off shutter from frames) exc. 1.5 Sqm but n exc 4 Sqm each, including cutting holes for removing the hold fast etc, disposing off the debris outsite the premises, complete all as specified and as directed. |
| 21 | S&F Galvanised steel wire cloth. 0.56mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed. |
| 22 | S&F Steel window with side shutter including projecting type hinges with steel handle and steel peg stay complete with glazing bars, dovetailed or welded as specified as directed. |
| 23 | S & F steel windows with side hung shutters including projection type hinghs with steel handle, and steel pag stay, complete without glazing bars, dovetailed or welded complete all as specified and as directed. |
| 24 | S&F for window guard bars let in and fixed independently in wooden frames or steel frames confirming to Fe 290 Gde E-165 complete all as specified and as directed. |
| 25 | S&F 3.00 mm thick sheet glass of ordinary quality and glazing with oil putty or rubber gasket steel frame in squares n exc 0.50 sqm in each pane complete all as specified and directed |
| 26 | Demolition of cement concrete (un-reinforced ) of any description & in any position not specifically provided for complete etc all as specified and as directed. |
| 27 | M&L for Rewriting repainting existing writing letters or figures (block roma, roman, italic, Indian n exc 30 cm height) complete all as specified and as directed. |
| 28 | M&L for 40mm thick cement concrete type B-0 (1:2:4:) (using 12.5 mm crushed stone aggregates) admixed with admixture aslan plints smartcare vitalla NEO (or any equlvalent brand of other manufacturer) at the rate of 200 gm /50Kg bag cement complete all as specified and as directed |
| 29 | M&L for rendering 10 mm thick in CM (1:4) on brick or concretesurfaces with water proofing compound at the rate of 3% by weight of cement.(WPC shall be measured saparately). |
| 30 | M &L for Surface Preparation : Surface to be free from frost, surface laitance and contamination free from loose aggregate or other sharp protrusions with fairly smooth finish for applicaion of water proof coating prime the surface with water. In cluding removal of all existing treatment, bituminious membrane, tarfelt.screed concrete etc from rcc slab complete all as specified and as directed |
| 31 | Application of waterproofing Coating : Providing and applying Fostoc Brushbond Roof Guard, a single component High build fibre Reinforced Acrylic Waterproofing render for roofing system to be applied by brush, at three coats at minimum dry film thickness of 1 mm, which should cure by reaction with atmospheric moisture to give a tough elastomeric waterproof membrane.Solid Content - 70%, Tensile strength ASTM D 412-1.10 Mpa, Elongation ASTM D12-100%, Resistance to ageing due to - 1000hours, UV radiation ASTM D4587 E - No Change, Rapid Chloride Penetration ASTM c 1202 - Very low, Pull off adhesion ASTM D541 - 0.92 Mpa, Resistance to Algae growth ASTM D 5589-97 - Passes, Zero rating, Permeability (mm) (BSEN 12390 part 8) -n 5.0, Water vapour transmission (ASTM E 96) - 6.0g/m2h. |
| 32 | M & L for Cracks & Honeycomb Treatment by Injection Grouting:- Identify the cracks and joints, shall be chased open into 'U' groove shape. Prepared suitable surface as require to apply the mortar. Apply a bond coat of Fosroc Nitobond SBR Latex and sealed with Shrinkage controlled, polymer modified, fiber reinforced cementitious repair mortar, Fosroc Renderoc SP40. Fixing PVC nozzle, injection grouting to be done with cement slurry admixed with expanding grout admixture cebex 100 to be mixed @ 225 gm per bag of cement. complete all as specified and as directed |
| 33 | M &L for Bore Packing: Bore packing to be done at pipe entries by forming proper formwork and filling the gap with non-shrinkable cementitious grout conbextra GP2 and sealed with epoxy/polyester sealant. |
| 34 | M & L for 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and as directed. |
| 35 | M&L for PCC (1:4:8) type D2 using 40mm graded aggregates in foundation filling and mass concrete as in lean concrete complete all as specified and as directed |
| 36 | M& L for PCC Providing cement concrete Type B1 (1:2:4) (using 20mm graded stone aggregates) in roof kerbs or mud stops, rounded or chamfered on edgesDitto, in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands plinth courses, string courses,lacing courses, parapets and railings upto 60cm in height,copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 37 | Preparation of new surfaces of walls and applying two coat of exterior emulsion (weather coat) over a coat of anti alkaline primer in different for camouflage and concealment of sigma II software design/ patterns approved by users complete all as specified and as directed. |
| 38 | Complete removal of existing treatment of walls and preparation of old plastered surface of walls including plasters and cornices etc and applying two coat of exterior emulsion (weather coat) over a coat of anti alkaline primer in different for camouflage and concealment of sigma II software design/ patterns approved by users complete all as specified and as directed. |
| 39 | Preparation of new surfaces of roof and applying two coat of exterior emulsion (weather coat) over a coat of anti alkaline primer in different for camouflage and concealment of sigma II software design/ patterns approved by users complete all as specified and as directed. |
| 40 | Taking down cement plaster on brick or concrete surfaces etc, including raking out joints, hacking for key, scrubbing down with water etc, and also including removal of rubbish off the premises, complete all as specified and directed. |
| 41 | M&L for rendering 15 mm thick in CM (1:4) on fair face of brick work or concrete surfaces finsihed even and fair (without using extra cement) mixed with water proofing compound as per manufacturer instructions, complete all as specified and as directed.Note:- WPC measured and paid separately. |
| 42 | Supply only integral water proofing compound, complete all as specified and as directed. |
| 43 | M&L for rendering 15 mm thick in cement mortar (1:6), on other than fair faces of brick work or concrete surfaces, finished even and fair without using extra cement, complete all as specified and directed. |
| 44 | M & L for preparing of new plastered surfaces of wall, etc and applying three coat of White wash etc complete all as specified and directed . |
| 45 | M & L for preparing of old plastered surface of wall by complete removal of existing treatment surface of wall applying two coat of White wash etc complete all as specified and directed . |
| 46 | Demolition of brick work or rubbled stone masonry including all quoins, arches , pillars etc built in cement mortar including disposing off the retrieved debris outside the premises, complete all as specified and as directed. |
| 47 | M&L for Brickwork with fly ash Bricks(old size), straight or curved on plan exc 6m mean radius ibuilt in Cement mortar (1:6), complete all as specified and directed |
| 48 | M&L for Preparation of new steel and iron surfaces of any description, over 10 cm in width or girth , not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and as directed |
| 49 | M&L for preparation of old painted surfaces of steel surface of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed |
| 50 | M & L for plain Cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in coping, filling and in mass concrete surface channels including necessary form work (straight or curved) weatheres slightly rounded or chamfrred angles and throating complete all as specified and directed. |
| 51 | Cutting chases pinning in for concealed conduit wiring and making goods of disturbed surface not exc 10 cm girth complete all as specified and directed. |
| 52 | S & F flame proof High bay light Wellglass 30W in CIMFR certified, die cast Aluminium housing with heat resistant toughened glass, recommended for Gas/Vapor group of IIA & IIB ands Zone 1 & 2 IP65 protected, pre wired and including connecting up copper conductor cable with SS flexible pipe 60cm long including taking down of old unserviceable complete all as specified and as directed. |
| 53 | S & F flame proof High bay light Wellglass 80W in CIMFR certified, die cast Aluminium housing with heat resistant toughened glass, recommended for Gas/Vapor group of IIA & IIB ands Zone 1 & 2 IP65 protected, pre wired and including connecting up copper conductor cable with SS flexible pipe 60cm long including taking down of old unserviceable complete all as specified and as directed. |
| 54 | S & F flame proof outdoor type MCB, DB, SPN 12 way with 200Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 55 | Material and labour for sub main wiring with 2 run of single core PVC insulated (unsheathed) multi stranded copper conductor FRLSH cable of size 1.5 sqmm and one single core PVC insulated (unsheathed) multi stranded copper conductor FRLSH cable of size 1.5 sqmm as in continuous earth wire drawn into and including concealed PVC conduit, medium grade of 20mm bore complete with fittings, PVC Junction Boxes, fixings accessories, also including cutting chases, pinning in, making good to facing and pointing in using cement mortar 1:3 and making good disturbed surfaces to match with the adjoining surfaces, including taking down existing sub main wiring complete all as specified and as directed.Note:- For payment purposes, 2 runs of main cable (each of 1RM) 1 run of earth continuity cable (1RM) and one run of conduit (1RM) all together shall be considered as \\"1RM\\". |
| 56 | S&F MCB, 'C' series SPN 32 Amps, breaking capacity 10KA fixed flush to wall and making good the disturbed surfaces in CM 1:3, complete all as specified and directed. |
| 57 | S&F MCB, 'C' series Single pole and neutral 2.5 to 6 Amps breaking capacity 10KA fixed flush to wall and making good the disturbed surfaces in CM 1:3, complete all as specified and directed. |
| 58 | Taking down of Aluminium/GI strip of any size and serviceable strip complete all as specified and as directed. |
| 59 | S & F Air termination single pointed Aluminum rod 16 mm dia, 1000mm long with thread size M16 including circular/horizontal aluminium air rod basethread size M16 and saddles with all fixing accessories complete all as directed and specified. |
| 60 | S & F Air termination single pointed Aluminum rod 16 mm dia, 1500mm long with thread size M16 including circular/horizontal aluminium air rod basethread size M16 and saddles with all fixing accessories complete all as directed and specified. |
| 61 | S & F Aluminium strip 25x3 mm with saddles fixing scrcub fixing etc for roof conductors down conductos above Ground complete all as directed and specified. |
| 62 | S & F G.I Strip 32x6mm burried in groundcomplete all as directed and specified. |
| 63 | M & l for cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as PCC cube of size 10cm x 10cm x 10cm, necessary fromwork (as/if required) complete all as specified and as directed. |
| 64 | M & L for horizontal boring under the road below 1 mtr from the road surface and dia of hole not exc 100mm without damaging the existing road out and disposal of soil to a distance not exceeding 50 M from the site of work complete all as directed and specified. |
| 65 | Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil, complete all as specified and as directed. |
| 66 | Returing filling in trenches including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and as directed |
| 67 | Removing excavated materials to a distance n exc 50 mtr and depositing where directed at a level n exc 1.5 mtr above the starting point complete all as specified and as directed |
| 68 | M & L for sand cushioning for protection of under ground cable consolidated and compacted with clean dry sand all as specified and directed. (compacted thickness shall only be measured and paid) complete all as specified and as directed |
| 69 | M & L for XLPE insulated GI wire/strip armoured electric power cable (heavy duty) with stranded aluminum conductor 1100 volts grade, cross sectional area 10 Sqmm 2core laid in trench/poles/on wall including taking down complete all as specified and directed. |
| 70 | M & L for brick protection cover of size 250x125x75 (old size) mm to FRLS cables with sub class 'B' over burnt brick, (locally available best quality) , laid dry and flat abutting each other with gaps n exc 10mm complete all as specified and directed. |
| 71 | S & F GI Tubes, 'light grade, 40mm dia for protection of cable on pole, under road crossing or across drain, along electric pole or floor/wall complete all as specified and directed. |
| 72 | S & F test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 Nos 8mm dia 25mm long hex head screw complete all as directed and specified. |
| 73 | S & F of DMC electrical insulator , for laying the Aluminium strip complete all as directed and specified. |
| 74 | M&L for Earthing complete with galvanized steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, connected to GI earth lead 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, PCC (1:3:6) type C-1 with 50 mm thick Pre-cast RCC (1:2:4) type B-1 cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (Medium grade), wire mesh, aluminium lugs, complete in all respect, GI earth strip protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 m and necessary testing on completion, including dismantling old unsv ones complete all as specified.Note: GI earth strip 25x4mm dia and 40mm bore protection pipe upto 7.5m from earth plate is deemed to be included in the rate quoted be contrator. |
| 75 | M&L for Earthing complete with galvanized steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, connected to copper strip 32x6mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, PCC (1:3:6) type C-1 with 50 mm thick Pre-cast RCC (1:2:4) type B-1 cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (Medium grade), wire mesh, aluminium lugs, complete in all respect, GI earth strip protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 m and necessary testing on completion, including dismantling old unsv ones complete all as specified .Note: GI earth strip 32x6mm dia and 40mm bore protection pipe upto 7.5m from earth plate is deemed to be included in the rate quoted be contrator. Please Enable Macros to View BoQ information |