| 1 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 2 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 3 | Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in :Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 4 | 12 mm cement plaster of mix : |
| 5 | 1:4 (1 cement: 4 fine sand) |
| 6 | Distempering with ist quality acrylic distemper (ready mixed) having VOC content less than 50 gram /litre of approved manufacture and of required shade and colour all complete to achieve even shade and colour to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gm/litre |
| 7 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including primingcoat of exterior primer applied @ 2.20 kg/10 sqm) |
| 8 | Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 9 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete |
| 11 | Providing and fixing M.S. grills of required pattern in frames of windows etc.with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete Fixed to openings /wooden frames with rawl plugs screws etc. |
| 12 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet andpolyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curvedsurfaces, excluding the cost of purlins, rafters and trusses and including cuttingto size and shape wherever required. |
| 13 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 14 | Earth work in excavation by mechanical means / manual means in foundation trenches(not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 15 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with metal clamps of approved make at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints, Including for all heights, necessary support, hanging works drilling holes at wall of all height and scaffolding charges etc complete as per direction of Engineer in Charge. External work- Exposed on Wall |
| 16 | 25 mm nominal dia Pipes |
| 17 | 20mm nominal dia Pipes |
| 18 | 15mm nominal dia Pipes |
| 19 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work 50 mm nominal dia Pipes |
| 20 | Providing and fixing Polyvinyl Chloride (PVC) pipes, including all fittings such as tee, jointing of pipes fitting, elbow with door if needed etc including for all heights, necessary support, hanging works drilling holes at wall of all height and solvent cement and testing of joints scaffolding charges etc with one step PVC one step complete as per direction of Engineer in Charge. External work- Exposed on Wall |
| 21 | 75 mm nominal dia Pipes |
| 22 | Providing and fixing 50mm ball valve (brass) of approved quality, High or low pressure, with plastic floats complete as per direction of Engineer-in-Charge |
| 23 | Providing and fixing 75mm ptrap of approved quality, High or low pressure, Including necessary fittings as per direction of Engineer-in-Charge |
| 24 | Providing and fixing 25mm ball valve (brass) of approved quality, High or low pressure, with plastic floats complete as per direction of Engineer-in-Charge |
| 25 | Providing and fixing 25 mm PTMT Ball cock (brass) of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. |
| 26 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink without drain board 610x460 mm bowl depth 200 mm. |
| 27 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C.waste fittings complete. Semi rigid pipe 32 mm dia |
| 28 | Providing and fixing C.P. brass bib cock of approved quality conforming toNIS:8931 : 15 mm nominal bore |
| 29 | Providing and placing on terrace (at all floor levels) polyethylene Anti bacterial water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 30 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking ofserviceable material within 50 metre lead as per direction of Engineer-in-Charge |
| 31 | Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. allcomplete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost). |
| 32 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade Please Enable Macros to View BoQ information |