| Sl. No. | Item Description |
| 1 | Civil work - Earth work in excavation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per the direction of the Engineer in Charge. |
| 2 | Earth work in excavation in all kinds of soil extra lift for 1.5m lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per the direction of the Engineer in Charge. |
| 3 | Cutting in disintegrated rock not requiring blasting to be removed by pick axes and crow bars and depositing materials within 50m initial lead and 1.5m initial lift including rough dressing as per direction and specification of the department including stacking the useful materials separately as ordered. |
| 4 | Filling the Foundation and Plinth, Sides of Foundation, etc. with excavated materials (excluding rock), in layers not exceeding 0.225 m in depth including cost of watering, ramming, dressing and levelling the top to proper level & gradient, cost of labour, conveyance, loading, unloading, T&P, etc, all complete as per the direction of Engineer-in-Charge. |
| 5 | Carriage of surplus earth by mechanical means upto 5km lead including cost of all labour for loading and unloading charges, transportation and spreading in layers at the dumping area etc complete as per specification and direction of Engineer in charge |
| 6 | Supplying, diluting and preparing chemical emulsion like Imidacloprid 30.5 % SC or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as Pre-Constructional Anti-termite Treatment confirming to IS 6313 (Part-II) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. at the rate of 7.5 liters per sqm on vertical surface and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center (or as directed by the manufacturer) including the cost of all materials, cost of all labour, conveyance, loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge. |
| 7 | Filling foundation with good quality river sand including watering, levellling, curing with cost, conveyance, royalty, taxes of all materials, labour with T&P required for the work etc complete as per specification and direction of the Engineer-in-charge |
| 8 | Cement concrete (1:3:6) in foundation and plinth using 4cmsize hard crusher broken granite stone metal of approved quality and from approved quarry including lowering, laying concrete watering, curing etc, complete to required levels laid in layers to required thickness including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge |
| 9 | RCC WORK - Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-25 Including the cost of Centering and Shuttering (minimum cement content not less than 403 Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance,loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of steel reinforcement.In Foundation & Column base |
| 10 | R.C.C. Plinth Beam |
| 11 | Pedestal &Column Super Structure GF |
| 12 | First Floor |
| 13 | Head Room |
| 14 | Roof Beam GF |
| 15 | First Floor |
| 16 | Head Room |
| 17 | R.C.C. Lintel GF |
| 18 | First Floor |
| 19 | Head Room |
| 20 | R.C.C. Chaja GF |
| 21 | First Floor |
| 22 | Head Room |
| 23 | R.C.C. staircase GF |
| 24 | First Floor |
| 25 | R.C.C. Roof Slab GF |
| 26 | First Floor |
| 27 | Head Room |
| 28 | Drain cover slab |
| 29 | Providing & fixing TOR Fe-500 HYSD Reinforcement bars of required diameter and approved quality for Reinforced Cement Concrete work including straightening, cutting, bending, binding, welding(if approved) , joining (if necessary), tying the grills, hoisting, lowering and placing in position as per the approved design & drawings (BBS) with provision of standard fan hooks including the cost of all materials, cost of all labour, conveyance, loading, unloading, cost of binding wires of 18 to 20 gauge, T&P, etc, all complete as per the direction of Engineer-in-Charge.Note: (Linear measurements will be taken & quantity will be calculated on standard weight. Lap length of bars & Weight of binding wire will not be considered for measurement and payment). GF |
| 30 | First Floor |
| 31 | Head Room |
| 32 | Providing and laying Brick Masonry work in Foundation & Plinth using Fly ash bricks of 25 Cm. x 12 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % confirming to IS 12894 and IS 2212 in cement mortar (1:6) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. |
| 33 | Providing Fly-Ash Brick masonry work in Superstructure using Fly-Ash Bricks of size 250mm x 120mm x80mm having crushing strength not less than 75Kg/Sqcm in cement mortar (1:4) with provision for two no.s of 6 mm dia after each 4th layer. including the cost of all materials, cost of labour, conveyance, taxes, loading, unloading, royalties, labour cess, scaffolding, curing for required period, T&P, etc. all complete as per the direction of the engineer-in-charge. GF |
| 34 | First Floor |
| 35 | Head Room |
| 36 | Providing and laying of Full Brick Masonry work in Superstructure using Fly ash bricks of 25 Cm. x 12 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % confirming to IS 12894 and IS 2212 in cement mortar (1:6) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. GF |
| 37 | First Floor |
| 38 | Providing 6 mm thick Cement Plaster in Cement Mortar of (1:4) to Ceilings of Roof Slabs, Stairs, Landings, Chajja, Shelves, Columns, Beams and Lofts etc. including roughening, scraping and cleaning and finishing the plastered surface smooth using wooden floats only to proper plumbs and level, making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading and royalties, all labour, scaffolding, watering and curing , sundries, T&P etc. complete as per direction of the Engineer-in-charge. GF |
| 39 | First Floor |
| 40 | Head Room |
| 41 | Providing 16mm thick Cement Plaster to the Surface of Brick Masonry Wall in Cement Mortar (1:6) including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc. complete as per direction of the Engineer-in-charge. GF |
| 42 | First Floor |
| 43 | Head Room |
| 44 | Providing 18 mm thick cement plaster in cement mortar (1:6) including racking out joints, scraping and cleaning the surface and finishing the plastered surface smooth using wooden floats with proper plumbs and level including the cost of all materials, labour, conveyance, taxes, loading and unloading, labour cess, royalties, scaffolding, watering and curing, T&P etc. complete as per direction of the engineer-in-charge. |
| 45 | First Floor |
| 46 | Head Room |
| 47 | Providing 2.5cm thick grading concrete of prop.(1:2:2) using 6mm size H.G. chips of approved quality & from approved quarry including watering, curing with cost, conveyances, taxes of all materials, cost of all labour, T&P required for the work etc. complete as per direction of Engineer-in-charge . First floor |
| 48 | Head Room |
| 49 | Providing and fixing of UPVC sliding windows 2 track sliding-60 series/Top hung ventilator of any approved make ,duly manufactured using upvc reinforced profiles of 62mm x 60mm x 2.25mm for outer frame, 66mm x 38mm x 2.25mm for sliding shutter frames capable of mounting single glazing system,structurally reinforced with hot dip galvanised upto 50 microns of minimum thickness of 1.2 mm prefabricated and welded through fusion welding & the window sash shall be fitted with 5 mm thick clear float glass of reputed make duly fixed with EPDM weathering seal including the cost of all materials,necessary locking arrangements ,fittings,cost of labour,T&P ,etc complete as per direction of Engineer-in-charge. |
| 50 | Supplying, fitting and fixing of 35mm thick flush door shutter with frame with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete |
| 51 | Supplying, fitting & fixing in all floors of M.S.grills gate in doors and windows with top rails, steel windows, critical frames for windows balustrades of stair case and parapet railing made out of M.S.square bar/flat as per approved drawing and design including making holes in walls and RCC structure, wood work etc and making good to the damages to walls with cement concrete(1:2:4) with hard crusher broken granite stone chips of 12mm to 20mm size(20mm size not to exceed 25%) of approved quality with cost of all materials labour, cost of welding all T&P, sundreis etc complete in all respect as per specification and direction of Engineer in charge(screws and other hardware required materials to be used in the work shall be of approved quality and specification and shall have to be supplied by the contractor at his own cost |
| 52 | Finishing wall surface with cement based wall putty(water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges, conveyance, taxes of all materials and cost of all labour with TandP etc complete as per specification and direction of Engineer in charge |
| 53 | Providing and applying Cement Primer (oil bound) to the internal plastered surface of approved make and quality and finished smooth and even surface to receive the paint including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc, all complete as per the direction of Engineer-in-Charge. G.F |
| 54 | First Floor |
| 55 | Head Room |
| 56 | Distempering two coats over a coat of primer with any approved shade and quality with oil bound distemper in interior surface of walls up to any height & in all floors to give an even shade including cost, conveyance, taxes of all materials with labour, T&P required for the work complete in all respect as per direction of the Engineer-in-charge G.F |
| 57 | First Floor |
| 58 | Head Room |
| 59 | Priming one coat of Cement Primer (water bound) to the external plastered surface of approved make and quality and finished smooth and even surface to receive the paint including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc, all complete as per the direction of Engineer-in-Charge. G.F |
| 60 | First Floor |
| 61 | Head Room |
| 62 | Painting two coats with anti-fungal resistance Weather Seal Coat of approved shade over a coat of (water bound) wall primer upto any height by means of brush to outside surface of walls after cleaning the surface including watering, curring etc. complete in all floors including cost, conveyance, taxes of all materials, labours sundries T&P required for the work as per specification and direction of Engineer in charge . GF |
| 63 | First Floor |
| 64 | Head Room |
| 65 | Providing and applying Red oxide Primer to the iron work approved make and quality and finished smooth and even surface to receive the paint including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc, all complete as per the direction of Engineer-in-Charge. G.F |
| 66 | First Floor |
| 67 | Head Room |
| 68 | Painting two coats with a coat of approved synthetic enamel paint over a coat of primer to wood or iron work including sand papering, polishing the surface, cost, conveyances of materials and cost of all labour TandP etc complete as per specification and direction of Engineer in charge). GF |
| 69 | First Floor |
| 70 | Head Room |
| 71 | Supplying, fitting and fixing of Vitrified tile of size (600x600mm) coloured/printed series (Homogeneous in floors marbonite or equivalent make in all floors over 20mm thick bed of cement mortar(1:4) jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royalties of materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge GF |
| 72 | First Floor |
| 73 | Supplying, fitting and fixing of Vitrified tile of size (600x600mm) coloured/printed series (Homogeneous in dadoes, skirting and steps marbonite or equivalent make in all floors over 20mm thick bed of cement mortar(1:3) jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royalties of materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge GF |
| 74 | First Floor |
| 75 | Providing fitting and fixing of Chequered tiles in floors of approved make over 25mm thick bed of cement mortar(1:1) jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royalties of materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge GF |
| 76 | Providing fitting and fixing of Granite stone tiles in dadoos and skirting of approved make over 12mm thick bed of cement mortar(1:3) jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royalties of materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge |
| 77 | First Floor |
| 78 | Providing fitting and fixing of Granite stone tiles in floors of approved make of size (300x300)mm confirming to IS:4457 over 20mm thick bed of cement mortar(1:4) jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royalties of materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge GF |
| 79 | First Floor |
| 80 | Providing fitting and fixing of Kota tiles of minimum 16mm thick (above 0.1 sqm) in floors of over 20mm thick bed of cement mortar(1:4) jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royalties of materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge GF |
| 81 | First Floor |
| 82 | Providing fitting and fixing of Kota tiles of minimum16mm thick(above 0.1 sqm) in dadoes / skirting over 12mm thick bed of cement mortar(1:3) jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royalties of materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge GF |
| 83 | First Floor |
| 84 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90 mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour, T&P etc.as per the direction of Engineer-in-Charge |
| 85 | Waterproofing to the roof slab(a) Surface preparation : Cleaning the surface thoroughly by chipping the roof slabs using breakers, wire brush, mechanical grinder for making it free from all loose particles, dust etc. then total cleaning through air blower followed by water jetting and allowing the surface to dry.(b) Application :Supply and application of Nano Technology OrganoSilane based Zycosil + @ 1:20 (one part Zycosil + and 20 parts of clean water) to the saturation level on the entire flat surface and upto 300mm (1ft.) to the parapet walls and then allowing for drying 24 hrs., test the surface for hydrophobicity. Then application of 100% acrylic co-polymer Zycoprime+, cement and fine sand (100 mesh) mixed at a consistency of paste form and filling drainage pipes gaps. Then application of one coat of Zycoat mix of Zycoprime + and grey cement @ 1:1.5 ratio ( 1 part Zycoprime + and 1.5 part cement). 2ndcpat of Zycoat mix to be applied after the drying of first coat in the same procedure followed by sprinkling of sieved sand on the top of the slurry. Then allow it to dry followed by proper curing with water for at least two days.(c) Coving :Coving has to be done with Zycomix (a mortar prepared with Zycoprime+, cement and sand in the ratio of 1:5:15 and water as per workability to obtain a uniform paste). Finally cure with water to the entire treated roof and parapet wall for three days. |
| 86 | Providing 12mm thick Cement Plaster to the Surface of Brick Masonry Wall in Cement Mortar (1:6) including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc. complete as per direction of the Engineer-in-charge. GF |
| 87 | Providing and lying Plain Cement Concrete of proportion (1:4:8) in foundation & floor using 40 mm grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -charge. |
| 88 | Providing and lying Plain Cement Concrete of proportion (1:2:4) in foundation & floor using 12 mm grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -charge. |
| 89 | EI works - Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Make of Modular GI box - Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision)NB:All the electrical,Fire fighting,HVAC,ELV drawings,LUX Level design of the arena lighting, Technical Data Sheets & make will be approved by SE R& B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work. GROUP-A |
| 90 | GROUP-B |
| 91 | GROUP-C |
| 92 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 93 | Supply and fixing of ISI marked modular type 2nos 6Amp socket with switch on suitable size of metal box and modular cover in front on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/-Schneider(Zencelo)/PANASONIC(VISION) |
| 94 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover( falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 95 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 96 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 97 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 98 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 99 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5) |
| 100 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB) (4X6+2X4) |
| 101 | Supply, delivery, installation & testing of Modular G.I. box 18 SWG Sheet ISI marked with Modular base & cover for 2 moudle tv socket outlet.Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) |
| 102 | Supply, delivery, installation and testing of TV Antenna Wires RG6 in PVC Pipe and making good the damages caused complete as required and as per Direction of Engineer-In-Charge. |
| 103 | Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 year against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 104 | Supplying and fixing of following sizes of HMS PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/BEC/Precision/Norpak/Kinjal.(Only for data, telephone, CCTV)20 MM |
| 105 | 25 MM |
| 106 | Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers(Make- Havells/Crompton/Usha/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 107 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.(fan Regulator compatible) . |
| 108 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) |
| 109 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 110 | SITC of Sleek LED 10 watt mirror light fitting with decorative aluminium LED batten having extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) |
| 111 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 112 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 /ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.4 Way(8+(4x3)+(3x4)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years |
| 113 | Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 230 volts, MCB . Make- LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 year. |
| 114 | Supplying and fixing 63 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 year. |
| 115 | Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 2P, 415 volts, RCCB 30mA . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year |
| 116 | Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (with charcoal and salt) as required and as per direction of Engineer-in-charge. |
| 117 | Providing and fixing 6 swg GI wire on surface or in recess for loop earthing as required and as per direction of Engineer-in-charge.. |
| 118 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 119 | S/I/T&Commissioning of LT indoor floor mounted CPRI Tested cubical type Main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 20X10MM Separate Aluminium Earth bus bar should be installed.All the incomers shall have 40 kA 3P+N type 2 SPD with 63 A 4P MCB, C series, 10 kA..In commer--01 number of 125 Amps MCCB 25 KA , 01 number of 125 Amps 4P onload type Changeover with both source ON/OFF indication (Make-Siemens/Schneider/ABB/LEGRAND)Busbar- 04 numbers of 125Amps 50kA Aluinuium busbar duly sleeved by color coaded PVC sleeve & supported by suitable size DMC insulator. Out going- (ii) 05 nos 63A 4P MCB 10kA,C series , 03 nos 63A DP MCB 10kA,C series, 02 nos 32A DP MCB 10kA,C series LIGHT BDB AC IDU BDB/LIGHT BDB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200Instrument- (i) 3 numbers phase indicating lamp for R,Y,B inndication for both the source with 2A SP MCB,C,10KA. ( Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200)..(ii) 01 set of 3 ph digital type Voltmeter(Make-Siemens/Schneider/ABB/Legrand).(iii)01 set of 3 ph digital type Ammeter(0-200)A(Make-Siemens/Schneider/ABB/Legrand) with CTs 125/5A 3 nos class 1 type(Make-Siemens/Schneider/ABB/Legrand) |
| 120 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5core x 50 sq mm |
| 121 | Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 3.5 core x50 sq mm |
| 122 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 123 | Supply installation of 33kV 3mm thick Class-C Rubber Mat as per IS-15652 and complete as per direction of Eng-in-charge.(Size-10mx1m) |
| 124 | Danger Board. |
| 125 | Supply and fixing of shock treatement charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel room. |
| 126 | PH work- Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge.Ground Floor25mm dia PVC ASTM pipe (sch-80),(For 2nos qtr) |
| 127 | 32mm dia PVC ASTM pipe (sch-80) |
| 128 | First Floor 25mm dia PVC ASTM pipe (sch-80) |
| 129 | 32mm dia PVC ASTM pipe (sch-80) |
| 130 | Second Floor 40mm dia PVC ASTM pipe (sch-80) |
| 131 | 50mm dia PVC ASTM pipe (sch-80) |
| 132 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor CPVC pipes conforming to IS:15778 having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00. spacing. This includes Jointing of pipes & fittings with one step CPVC solvent cement and testing of Joints all complete as per specification and direction of the Engineer in charge.Ground Floor-20mm dia CPVC pipe. (For 2nos qtr) |
| 133 | 25mm dia CPVC pipe |
| 134 | First Floor 20mm dia CPVC pipe |
| 135 | 25mm dia CPVC pipe |
| 136 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.250mm thick wall Ground Floor (For 2nos qtr) |
| 137 | First Floor |
| 138 | Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing GI pipes / PVC pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof as per direction of the Engineer in charge.Ground Floor (For 2nos qtr) |
| 139 | First Floor |
| 140 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge.Ground Floor (For 2nos qtr) |
| 141 | First Floor |
| 142 | Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge. 15 mm dia 2 WAY BIB COCK WITH WALL FLANGE (FLR-CHR-5041N Jaquar Make) (For 2nos qtr) |
| 143 | 15mm dia CP Health Faucet (ALD-CHR- 577) |
| 144 | 15mm dia CP Long body bib cock(Jaquar)CON-CHR-107KN |
| 145 | 15mm dia CP ANGULAR STOP COCK WITH WALL FLANGE (FLR-MCH-5053N Jaquar Make ) |
| 146 | 20mm dia CP concealed stop cock(Jaquar)CON-CHR-087KN |
| 147 | 32mm dia CP Bottle trap (Jaquar make)-ALD -CHR-769L -300x190cm |
| 148 | 15 mm dia CP pillar cock (Jaquar)-PRS-CHR-031 |
| 149 | Sink Cock - Jaquar Make - CON-CHR-349KNM |
| 150 | CP soap Dish holder (Jaquar make)-AKP -ABR-35731P |
| 151 | Towel Ring Round - (As Per Jaquar,Cat no.:ACN-CHR-1121BN), Jaquar/Cera/hindware/equivalent Make |
| 152 | 600mm long CP towel rail(Jaquar)-ACN-IVY-1111NM |
| 153 | 25mm dia brass or gun metal fullway valve (Shakti Make) |
| 154 | 32mm dia brass or gun metal fullway valve (Shakti Make) |
| 155 | 50mm dia brass or gun metal fullway valve (Shakti Make) |
| 156 | 15mm dia CP flange |
| 157 | 15mm dia CP extension piece |
| 158 | Supplying all materials, labour, T&P and fitting and fixing CP shower with 15mm or 20mm inlet with CP shower arm including polishing all complete as per specification and direction of the Engineer in charge.15mm dia CP revolving shower With shower arm Jaquar/Cera/hindware/equivalent Make OHS-CHR-1985+SHA-CHR-477 |
| 159 | Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge 10 litres capacity pvc low level cistern with 32mm dia CP long flush bend Slimline white (Hindware / Parryware Make) (For 2nos qtr) |
| 160 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge In ground floor110mm dia U-PVC SWR pipe (Ashirbad /Sentinity/Supreeme) (For 2nos qtr) |
| 161 | 50mm dia U-PVC class-IV pipes (Ashirbad /Sentinity/Supreeme) (For 2nos qtr) |
| 162 | 110mm U-PVC door tee |
| 163 | 110mm U-PVC Plain tee |
| 164 | 110mm U-PVC door bend |
| 165 | 110mm U-PVC plain bend |
| 166 | 110mm dia U-PVC 'P' trap |
| 167 | 110mm dia U-PVC Plain Shoe Bend |
| 168 | 110mm dia U-PVC offset with out ear |
| 169 | 110mm dia U-PVC cowl |
| 170 | 125mm dia CP grating |
| 171 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge. 250mm to 375mm thick wall. (For 2nos qtr) |
| 172 | Supplying all materials, labour, T&P and cutting of R.C.C roof or cornice for taking H.C.I pipes and making good the damages etc all complete as per P.H. Specification and direction of the Engineer in charge. (For 2nos qtr) |
| 173 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x 30mm footrest, fixing 100mm dia HCI ‘P’ or ‘S’ trap (with/without 50mm dia horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc all complete as per specification and direction of the Engineer in charge 580mm size Orissa pan (Parryware/Hendware/Equivalent make ) |
| 174 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge. European water closet with ‘S’ trap plain with seat cover (Parryware/Hendware/Cera/Somany/Kerovit) (Hindware)No.20079 (For 2nos qtr) |
| 175 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps conforming to IS:2556-part-4-2004 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore(Plaza make), fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste(Plaza make), etc all complete as per specification and direction of the Engineer in chargeHalf pedestal Basin(Hindware)No.91049+91115 |
| 176 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the Engineer in charge. 550mmx440 mm size wash hand basin With porcelain pedestal (Parryware/Hindware/Cera) |
| 177 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge. Design mirror (Parryware make) (For 2nos qtr) |
| 178 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to wooden plugs with CP screws as per specification and direction of the Engineer in chargeGlass shelf 600mm long(ACN-CHR-1171N) |
| 179 | Supplying all materials, labour, T&P and fixing wash kitchen sink with cast iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge. 600x450x250 mm stainless steel kitchen sink-glossy-IS:13983 - 1994 (Jayna make) (For 2nos qtr) |
| 180 | Supplying all materials, labour, T&P and providing cement concrete (1:4:8) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. In ground floor |
| 181 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. (For 2nos qtr) Ground Floor |
| 182 | First floor |
| 183 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge (For 2nos qtr) Ground Floor |
| 184 | First floor |
| 185 | Supplying all materials, labour, T&P and providing ceramic tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. 60 cm. x 60 cm. Kajaria / Somany / Johnson to be pre |
| 186 | First floor |
| 187 | Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. Kajaria / Somany 600x 300 size. (For 2nos qtr) Ground Floor |
| 188 | First floor |
| 189 | Supplying all materials, labour, T&P and providing distempering 2 coats to walls with distemper of approved shade on new work to give an even shade etc all complete as per specification and direction of the Engineer in charge. (For 2nos qtr) Ground Floor |
| 190 | First Floor |
| 191 | Finishing wall surface of walls with Acrylic wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T&P etc complete. (For 2nos qtr) Ground Floor |
| 192 | First Floor |
| 193 | Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I (ISI marked) size 100mm are to be fitted on one side of shutter. (For 2nos qtr) |
| 194 | Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge. (For 2nos qtr) |
| 195 | Supply of all materials & laying the waterproofing material Pidifin 2K of Dr.Fixit on equivalent water proofing material after drying cleaning the concrete surface over the concrete floor/roof/ balcony/sunken and dado upto 1\\"6\\" in wall including cleaning,applying and mending as per specification including cost,conveyance,taxes,royalities of all materials to work site etc.all complete as per the direction of the Engineer-in-charge. (For 2nos qtr) First Floor |
| 196 | 12 mm thick cement plaster (1:4) over brick work with cement punning for skirting.First floor (For 2nos qtr) |
| 197 | Supplying all materials, labour, T&P and filling in sunken floor in toilets with cinter (light weight slag) well watered and rammed include conveyance of all materials to worksite payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. (For 2nos qtr) First Floor |
| 198 | Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation(G.I/P.V.C/M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore. Labour for Drilling of 200 mm dia bore 0mtr to 120mtr |
| 199 | Labour for Drilling of 150 mm dia bore 0mtr to 120mtr |
| 200 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. Lowering of 200 mm dia GI/P.V.C/MS casing pipes 0 mtr to 50 mtrs |
| 201 | Cost of 200 mm dia ASTM-D-1785/89 P.V.C schedule-80 pipe |
| 202 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge By DTH |
| 203 | Supplying all materials and labour,tools and plant and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5 mtrs below ground level(as per drawing)to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock the bottom to ensure sanitary sealing(excluding cost of cement which willbe supplied by the Department). Submerssible Pump Set 1 H.P three phase 3 stage head range 30 to 54 metres, discharge 155 to 6110 L.M.P with outlet dia of 32 mm. |
| 204 | DOL control panel |
| 205 | 2.50 sqmm cable |
| 206 | 32mm dia steel short piece |
| 207 | 32 mm dia HDPE Pipe |
| 208 | Bore Cap |
| 209 | C.I.Bracket |
| 210 | Rope Wire |
| 211 | Labour charges for lowering of submesible pumpset with pipes and cables etc. with testing and commissioning at site. |
| 212 | Supply all materials,labours,T&P and construction bore well protection chamber of the inside size 650x650x1000 height with cement concrete ( 1;3;6) using 40 mm size hard granite metal on foundation,1st class fly ash brickwork incement motar(1:3),with base cement concrete (1:2:4) useing 12 mm size h.g chips ,12 mm thick cement plaster (1:4) inside and out site ,R CC cover slab in (1:1.5:3) using 12 mm size h.g chips earthwork in excavation in all kinds of soil and refiling the cavity around the chamber including watering ,curing,convayance of all materials to worksite,payment of royalty,taxes etc all complete as per approved specification and direction of the engineer-in -charge. Bore well protection chamber. |
| 213 | EXTERNAL P.H. WORK Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. 110mm dia U-PVC Alround Concrete |
| 214 | 160mm dia U-PVC Alround Concrete |
| 215 | Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge.Inside size 250mmx250mm |
| 216 | Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mmx760mmx460mm . |
| 217 | ---- do --- addl depth of 0.15m upto 0.90m |
| 218 | R.C.P.C.Manhole Cover |
| 219 | Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 910mmx910mmx910mm |
| 220 | R.C.P.C.Manhole Cover |
| 221 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.1.40m dia x 2.00m deep soakway pit |
| 222 | Supplying all materials,labour,T&P and fixing 1000 ltr Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class K.B brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge,second floor |
| 223 | Construction 2 nos 20 users RCC Septic tank Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge. |
| 224 | - do - with addl. Depth of 1.5 m |
| 225 | Excavation of foundation in laterite rock or any hard rock (other than granite or disintegrated rock) removed by chiselling including dressing and levelling the bed not exceeding 1.50 mtr. in depth and depositing the soil within initial lead of 50 mtr. and as per specification approved by the Department. |
| 226 | Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge In ground floor |
| 227 | Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. In ground floor |
| 228 | Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 229 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge Roof Slab- |
| 230 | For RCC wall |
| 231 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 232 | Supplying all materials,labour,T&P and providing 6mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 233 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. |
| 234 | Supplying all materials, labour, T&P and fitting and fixing S.W.Tee of size 160mx160mx160m as per P.H.D.specification and direction of the E.I.C. |
| 235 | Supplying all materials, labour, T&P and constructing vent base as per P.H.D specification etc all complete. |
| 236 | Supplying all materials, labour, T&P and fitting and fixing UPVC SWR soil waste ventilating pipes and fittings to walls with nails, bobbins and wooden plugs or laying in trenches including earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. 110mm diameter U-PVC SWR pipe |
| 237 | 110mm dia U-PVC Plain shoe bend |
| 238 | 110mm dia U-PVC Cowl |
| 239 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge 1 x2 x(3.00+1.50) x 0.15 x 2.00 |
| 240 | CONSTRUCTION OF 10000 LTR RCC SUMP 1nos Earthwork in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to minimum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer in charge. Initial lift - |
| 241 | Earthwork in excavation of foundation in stonety earth mixed with gravel within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to minimum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer in charge. 1st Extra lift |
| 242 | Supplying all materials, labour, T&P and providing filling sand including watering, ramming and conveyance of all materials to site. |
| 243 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 40mm H.G metal including watering, curing and conveyance of all materials to site. |
| 244 | Supplying all materials, labour,T&P and providing cement concrete (1:1.5:3) for RCC work using 12mm HG chips including hoisting,laying,curring and conveyance of all materials to site etc complete. |
| 245 | Supplying all materials, labour, T&P and providing brick work with K.B bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:3) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 246 | Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage. |
| 247 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in ground floor. RCC walls |
| 248 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:3) including watering,curring and conveyance of all materials to site. |
| 249 | Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site. (1no) |
| 250 | Supplying all materials, labour, T&P and futting and fixing 20mm dia MS/CI step iron including supply of necessary C.C(1:2:4) for fixing etc complete as per P.H.D. specification. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail